• 제목/요약/키워드: DC link current

검색결과 511건 처리시간 0.024초

Optimal Design for Hybrid Active Power Filter Using Particle Swarm Optimization

  • Alloui, Nada;Fetha, Cherif
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권3호
    • /
    • pp.129-135
    • /
    • 2017
  • This paper introduces a design and a simulation of a hybrid active power filter (HAPF) for harmonics reduction given an ideal supply source. The synchronous reference frame method has been used here to identify the reference currents. The proposed HAPF uses a new artificial- intelligence technique called Particle Swarm Optimization (PSO) for tuning the parameters of a proportional and integral controller called PI-PSO. The PI-PSO controller is used to archive optimality for the DC-link voltage of the HAPF-inverter. The hysteresis non-linear current control method is used in this approach to compare the extracted reference and the actual currents in order to generate the pulse gate required for the HAPF. Results obtained by simulations with Matlab/Simuling show that the proposed approach is very flexible and effective for eliminating harmonic currents generated by the non-linear load with the HAPF based PSO tuning.

노트북 컴퓨터 어댑터용 LLC 하프 브리지 공진형 컨버터 최적설계 (Optimal Design of the LLC HB Resonant Converter for Notebook Computer Adapter)

  • 유병선;김창선
    • 전기학회논문지
    • /
    • 제56권8호
    • /
    • pp.1418-1423
    • /
    • 2007
  • The topology of LLC half bridge resonant converter provides ZVS characteristic. The voltage stress and current stress are smaller than that of the general resonant converters. So the LLC HB resonant converter can be considered as a optimal circuit for the notebook computer adapter. In the adapter design, we should consider the weight, the size and the overheat of the adapter. Thus the higher efficiency is an essential particular. First of all, the optimal design of transformer is the most important facts. Some parameters should be considered in order to get the highest efficiency. The adapter is designed through the considering of these parameters including the PFC circuit as the pre-regulator. It converts AC line input into about DC 390V link voltage of the LLC HB converter input and the converter has 16V/90W ratings. The efficiency measured is about up to 93%.

45kVA UPQC 제어 알고리즘 설계 (A Control Algorithm Design for 45kVA UPQC Prototype)

  • 전진홍;김태진;류홍제;안종보
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1483-1485
    • /
    • 2005
  • In recent years, customers and power supplies are interested in power quality. Demands of customers are change from standard quality of distribution power system to various high quality of distribution power system. so, it is necessary to apply power quality compensator. in our project, we develop the UPQC(Unfied Power Quality Compensator of 45kVA which compensates power factor and voltage sag, interruption. it is very frequently occurred power quality problems. As a series and shunt compensator, UPQC consists of two inverters with common dc link capacitor bank. It compensates the current quality in the shunt part and the voltage quality in the series part. In this paper, we present simulation and test result of developed UPQC system. Test for UPQC are performed at voltage sag, flickers and non-linear load conditions. For voltage sag and ficker generation, we use RTDS(Real Time Digital Simulator) and power amplifier system.

  • PDF

A Fault Tolerant Strategy Based on Model Predictive Control for Full Bidirectional Switches Indirect Matrix Converter

  • Le, Van-Tien;Lee, Hong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.74-76
    • /
    • 2019
  • This paper proposes an open-switch fault tolerant strategy based on the model predictive control for a full bidirectional switches indirect matrix converter (FBS-IMC). Compared to the conventional Indirect Matrix Converter (IMC), the FBS-IMC can provide healthy current path when open-switch fault is occurred. To keep the continuous operation, the fault tolerant strategy is developed by means of reversing the DC-link voltage polarity regardless of the faulty switch location in the rectifier or inverter stage. Therefore, the proposed control strategy can maintain the same input and output performances during the faulty condition as the normal condition. The simulation results are given to verify the effectiveness of the proposed strategy.

  • PDF

IPMSM 드라이브에서 전류 기울기 정보를 이용한 데드타임 및 인버터 비선형성 효과의 간단한 제거 기법 (Simple On-line Elimination Strategy of Dead Time and Nonlinearity in Inverter-fed IPMSM Drive Using Current Slope Information)

  • 박동민;김명복;김경화
    • 전력전자학회논문지
    • /
    • 제17권5호
    • /
    • pp.401-408
    • /
    • 2012
  • A simple on-line elimination strategy of the dead time and inverter nonlinearity using the current slope information is presented for a PWM inverter-fed IPMSM (Interior Permanent Magnet Synchronous Motor) drive. In a PWM inverter-fed IPMSM drive, a dead time is inserted to prevent a breakdown of switching device. This distorts the inverter output voltage, resulting in a current distortion and torque ripple. In addition to the dead time, inverter nonlinearity exists in switching devices of the PWM inverter, which is generally dependent on operating conditions such as the temperature, DC link voltage, and current. The proposed scheme is based on the fact that the d-axis current ripple is mainly caused by the dead time and inverter nonlinearity. To eliminate such an influence, the current slope information is determined. The obtained current slope information is processed by the PI controller to estimate the disturbance caused by the dead time and inverter nonlinearity. The overall system is implemented using DSP TMS320F28335 and the validity of the proposed algorithm is verified through the simulation and experiments. Without requiring any additional hardware, the proposed scheme can effectively eliminate the dead time and inverter nonlinearity even in the presence of the parameter uncertainty.

고역율 PWM 매트릭스 컨버터의 개선된 순시추종 제어함수 (Improved instantaneous Following Control Function for High Power Factor PWM Matrix Converter)

  • 김광태
    • 조명전기설비학회논문지
    • /
    • 제19권3호
    • /
    • pp.35-43
    • /
    • 2005
  • 종래의 컨버터-인버터 전력변환 시스템에서 do-link를 제거하여 보다 효과적인 인버터를 만들기 위하여 매트릭스 컨버터에 관하여 연구를 하고자 한다. 따라서 매트릭스 컨버터는 에너지를 저장하는 능동소자를 갖지 않는 장점이 있으나 전원이 스위치를 통하여 직접 부하에 연결되므로 전원의 리플과 노이즈가 그대로 부하에 전달되는 결점을 갖는다. 매트릭스 컨버터는 전원을 부하에 대하여 정현적으로 스위칭해야 되며, 한편 이러한 노이즈를 제거 및 보상하는 특성과 함께 역율문제도 함께 해결해야 한다. 본 연구에서는 종래의 제시된 방법에 비하여 제어어시간을 단축시킨 제어함수를 제시한다. 제시된 제어함수는 전원에 포함된 리플과 노이즈를 스위칭하는 과정에서 자동으로 보상하며 역율 1이되게 스위칭한다. 시뮬레이션 결과와 실험결과를 함께 제시한다.

고속 엘리베이터에서 3상 유도전동기의 강건한 구동을 위한 DTIF 제어기의 구현 (Implemention of a DTIF Controller for Robust Drive of a 3 Phase Induction Motor in High-Speed Elevator)

  • 김동진;강창수;한완옥
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제9권3호
    • /
    • pp.88-96
    • /
    • 1995
  • 고속 엘리베이터는 높은 안정성과 제어성이 필요하므로 기동, 정지시에 영 속도를 포함한 정밀 구동이 필요하다. 유도전동기의 정밀 구동을 위하여 사용되어온 벡터 제어 기법은 슬립 주파수 제어에 의한 간접 벡터 제어와 계자편향에 의한 직접벡터 제어의 두가지 종류로 분류할 수 있으며, 직접벡터제어의 경우 전동기 제어 변수의 변화에 강건한 반면에 직접 벡터 제어의 경우 비교적 넓은 속도구간에서 제어가 가능하다는 장점을 가지고 있다. 본 논문에서 토크는 직접 벡터기반으로 제어하고, 지속은 간접 벡터 기반으로 제어함으로써 유도전동기의 과도상태 동작과 시동시 영 속도 부근 및 저속 영역에서의 동작이 보다 강건하도록 개선된 직접토크-간접자속(DTIF, Direct Torque Indirect Flux)제어기를 제시하였다. 3상 유도전동기의 구동을 위하여 제안된 시스템의 수행결과는 시뮬레이션과 실험을 통하여 입증하였으며, 영 속도부근과 저속에서 고속으로의 변환과정은 속도응답에 대한 상전압, 상전류 그리고 DC링크 전류를 비교 측정하여 안정하고 강건한 속도변화가 이루어짐을 확인 할 수 있었다.

  • PDF

대전력 3상 유도전동기의 고정자권선을 이용한 전압원 인버터의 병렬운전 (Parallel Operation of Voltage Source Inverters by Using Stator Windings of High Power Three-Phase Induction Motors)

  • 김인동;노의철;전성즙
    • 한국정보통신학회논문지
    • /
    • 제8권4호
    • /
    • pp.815-820
    • /
    • 2004
  • 본 논문에서는 고압 대전력 3상 유도전동기의 고정자 권선을 이용한 전압원 인버터의 병렬운전 방식을 제안한다. 현재 사용되고 있는 대부분의 4극 이상 대전력 유도전동기는 각 상의 권선이 외부에서 접근이 가능하도록 외부단자가 설치되어 있으며, 이들 외부 단자를 이용하여 복수대의 전압원 인버터를 병렬운전 하여 대전력 유도전동기를 구동할 수 있다. 이와 같이 고압 대전력 유도전동기를 복수 개의 전압원 인버터를 병렬 운전하여 구동할 경우, 특정 인버터의 고장발생 시 비록 구동 토오크는 감소될지라도, 나머지 인버터로 시스템을 계속 구동할 수 있어 시스템의 고장대처능력을 향상시킬 수 있다. 또한 병렬 운전되고 있는 각 인버터의 스위칭 동작에 대해 서로 위상차를 갖게 함으로서, 등가 스위칭 주파수를 증가시켜 출력 토오크 리플 감소와 입력 전류 리플 감소, DC Link 커패시터의 크기 감소와 같은 좋은 특성을 얻을 수 있다. 또한 각 인버터로의 전력의 분산에 의해 시스템에서 발생하는 EMI영향을 감소시킬 수 있다. 본 논문에서는 제안한 방식을 컴퓨터 시뮬레이션을 통해 특성을 증명하였다.

영구자석 동기전동기 구동을 위한 전압원 인버터의 적응제어기법을 이용한 전압 왜곡 관측 및 보상 (Observation and Compensation of Voltage Distortion of PWM VSI for PMSM using Adaptive Control Method)

  • 김학원;윤명중;김현수;조관열
    • 전력전자학회논문지
    • /
    • 제10권1호
    • /
    • pp.52-60
    • /
    • 2005
  • 펄스 폭 변조 전압원 인버터에서는 전압 명령과 실제 전압 사이에 전압 차 또는 전압 왜곡이 존재한다. 이 전압 왜곡은 동작 온도, DC 링크 전압, 및 상전류 수준에 따라 달라진다. 또한 전압 왜곡은 전류 왜곡, 전동기 토크 맥동, 그리고 제어 성능에 영향을 미친다. 본 논문에서는 펄스 폭 변조 전압원 인버터의 전압 왜곡을 분석하고, 모델기준 적응 시스템(Model Reference Adaptive System)을 기반으로 하여 영구자석 동기 전동기의 파라미터 변화에 강인한 새로운 실시간 전압 왜곡 관측 기법을 제안한다. 그리고 제안된 전압 왜곡 관측 및 보상 기법에 대한 모의실험 및 실험을 통해서 그 효용성을 증명한다.

Sensorless vector control for super-high speed PMSM drive

  • Bae Bon-Ho;Sul Seung-Ki;Kwon Jeong-Hyeck;Shin Jong-Sub
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.773-778
    • /
    • 2001
  • This paper describes the implementation of the vector control schemes for a variable-speed 131kW PMSM (Permanent Magnet Synchronous Motor) in super-high speed application. The vector control with synchronous reference frame current regulator has been implemented with the challenging requirements such as the extremely low stator inductance$(28^{\mu}H)$, the high dc link voltage(600V) and the high excitation frequency(1.2kHz). Because the conventional position sensor is not reliable in super-high speed, a vector control scheme without any position sensor has been proposed. The proposed sensorless algorithm is implemented by processing the output voltage of the PI current regulator, and hence the structure is simple and the estimated speed is robust to the measurement noise. The experimental system has been built and the proposed control has been implemented and evaluated. The test result, up to the speed of 60,000 r/min, shows the validity of the proposed control.

  • PDF