• 제목/요약/키워드: DC bus

검색결과 271건 처리시간 0.022초

Improved Charge Pump Power Factor Correction Electronic Ballast Based on Class DE Inverter

  • Thongkullaphat, Sarayoot
    • International journal of advanced smart convergence
    • /
    • 제4권1호
    • /
    • pp.64-70
    • /
    • 2015
  • This paper proposes fluorescent electronic ballast with high power factor and low line input current harmonics. The system performance can be improved by a charged pump circuit. Details of design and circuit operation are described. The proposed electronic ballast is modified from single-stage half bridge class D electronic ballast by adding capacitor parallel with each power switch and setting the circuit parameter to operate under class DE inverter condition. By using this proposed method the DC bus voltage can be reduced around by 50% compare with conventional class D inverter circuit. Because the power switches are operated at zero voltage switching condition and low dv/dt of class DE switching. The experimental results show that the proper frequency of the prototype is around 50 kHz with input power factor of 0.982, $THD_i$ 10.2% at full load and efficiency of more than 90%.

MCFC 백업용 EBOP 요소기술 개발 (Development of EBOP element technologies for MCFC backup system)

  • 유성래;오은태;정자훈;황정태;차인호;곽철훈
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.92-92
    • /
    • 2010
  • 여수 국가산업단지, 삼성전자 정전사례에서 볼 수 있듯이 대규모 정전사고는 수백억 이상의 경제적 손실이 뒤따른다. 공장 내에 자체 발전소가 있지만 매번 이런 사고가 재연되어 근본적인 해결책이 필요한 상황이다. UPS 및 디젤발전기를 사용하는 경우, 정전사고로 시 UPS DC bus전압이 일정 수준 이하로 떨어지면 발전기가 기동하여 에너지를 공급하는데 발전기의 특성에 따라 전압의 변동이 심하고 초기기동실패 사례가 종종 보고되고 있다. 본 연구는 연료전지와 전력저장장치의 연계를 통해 산업설비에 안정적으로 전원을 공급하고자 하는 방법에 관한 것으로 연계 제어 로직개발과 Load Leveler, Compensator, STS 등 구성요소 개발을 주요 연구 내용으로 하고 있다. 고온형 연료전지의 열적 안정성을 유지하면서 독립전원의 부하 변동에 대응하기 위한 부가 설비가 기존 제품에 추가 장착되어야 하며, 연계 제어 알고리즘의 확보를 위하여 연료전지 모델링 및 통합시스템 시뮬레이션을 수행하였다. 본 연구에서는 이상과 같은 시뮬레이션 및 백업 모듈 설계 결과를 제시하고자 한다.

  • PDF

A Three-Phase Four-Wire DSTATCOM for Power Quality Improvement

  • Singh, Bhim;Jayaprakash, P.;Kothari, D.P.
    • Journal of Power Electronics
    • /
    • 제8권3호
    • /
    • pp.259-267
    • /
    • 2008
  • Power quality improvement in a three-phase four-wire system is achieved using a new topology of DSTATCOM (distribution static compensator) consisting of a star/delta transformer with a tertiary winding and a three-leg VSC (voltage source converter). This new topology of DSTATCOM is proposed for power factor correction or voltage regulation along with harmonic elimination, load balancing and neutral current compensation. A tertiary winding is introduced in each phase for a delta connected secondary in addition to the star-star windings and this delta connected winding is responsible for neutral current compensation. The dynamic performance of the proposed DSTATCOM system is demonstrated using MATLAB with its Simulink and Power System Blockset (PSB) toolboxes under varying loads. The capacitor supported DC bus of the DSTATCOM is regulated to the reference voltage under varying loads.

전압형 Dual PWM 컨버터의 변조각 지연에 따른 보상법 및 순시전류 제어기 구성 (The Compensation Method of the Modulation-delay for the Voltage type Dual PWM Converter and Composition of the Instantaneous Current Controller)

  • 정연택;김원철;이사영;전지용;김현봉;이근홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.369-372
    • /
    • 1994
  • In this paper, a voltage type dual PWM converter which achives the bidirectional power flow between a AC supply and a DC bus voltage is described. In PWM modulator, there exist a time difference between the sampling time and carrier wave, it achieves stable modulation even the disturbance in the synchronous AC source voltage. And this paper proposes the compensation method and the control method related a disturbance of synchronous signal using the low pass filter and phase shifter for the stable modulation. As a result the voltage type dual PWM converter makes the imput current wave as sinusoid, and performs the high power factor driving.

  • PDF

Battery Energy Storage Based Voltage and Frequency Controller for Isolated Pico Hydro Systems

  • Singh, Bhim;Rajagopal, V.
    • Journal of Power Electronics
    • /
    • 제9권6호
    • /
    • pp.874-883
    • /
    • 2009
  • This paper deals with an integrated voltage and frequency (VF) controller for isolated asynchronous generators (IAG) driven by a constant power pico-hydro uncontrolled turbine feeding three-phase four-wire loads. The proposed VF controller is used to control the frequency and voltage of an IAG with load leveling. Such a VF controller is also known as an integrated electronic load controller (IELC) which is realized using an isolated star/polygon transformer with a voltage source converter (VSC) and a battery at its DC bus. The proposed generating system with a VFC is modeled and simulated in MATLAB along with Simulink and Simpower system (SPS) toolboxes. The simulated results are presented to demonstrate the performance of an isolated asynchronous generator feeding three-phase four-wire loads with neutral current compensation.

Fault Immune Pico-Hydro Powered Base Station of Remote Telecommunication Tower

  • Verma, Vishal;Pant, Peeyush;Singh, Bhim
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1612-1620
    • /
    • 2016
  • This paper presents the dynamic excitation control of a siphon-turbine coupled pico-hydro powered cage rotor induction generator and load matching for off-grid electricity generation. Through the proposed dual-role of the current-controlled voltage source converter (VSC), acting as static synchronous compensator and load controller, real and reactive power are dynamically controlled in a decoupled manner with a self supported DC-bus. The proposed scheme entails minimal computation for ensuring the rated (set) capacity of real power. The scheme also exhibits fault immunity for protection, thus enabling the effective handling of constant power electrical loads presented by base telecom station towers in remote locations. The performance of the system is evaluated under MATLAB/Simulink and is experimented through a developed hardware prototype. Simulation and experimental results show close conformity and validate the effectiveness of the proposed scheme.

인버터를 이용한 유도전동기 감속 성능 개선 (The Performance Improvement of stopping for Induction Motor Using AC Drive)

  • 박경훈;한경식
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.296-297
    • /
    • 2011
  • Many applications involving induction motors that are controlled using variable frequency drives require the ability to stop quickly. These applications include emergency stops, quick stopping of fans, centrifuges, presses, etc. The technique that is widely accepted in the industry for achieving quick stopping makes use of brake resistors in series with a power semiconductor switch. The switch-resistor combination (brake-unit) is applied across the dc bus. The fastest decelerating time achievable depends on the size of the resistors and the switch employed. In this paper, the authors propose a novel method of achieving quick stopping times without the use of any brake-unit. Experimental test results with and without this method on a large inertia motor-load combination show that the proposed stopping method is able to reduce the stopping time significantly compared to normal decelerated stop without the need for a braking unit.

  • PDF

출력 파형 왜율과 효율 개선을 위한 CRPWM의 전압 제어 방법 (A New Voltage Control Method in CRPWM for Improving Distortion and Efficiency at Load Side)

  • 안성찬;송종환;조규복;원종수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1104-1107
    • /
    • 1992
  • Voltage controlled current regulated PWM(pulse width modulation) of VSI (voltage source inverter) is proposed. Adopting one degree of freedom, the voltage, the current controller shows much more improvement than conventional ones not using this method. The voltage controller or this proposal needs load's parameters, torque value, rotational speed. This voltage controller is located at converter part which links AC source and DC bus. With this proposed method, duty ratio of the inverter's switching is nearly unity for all speed and torque range. Hence, this method gets many advantages such as reducing current ripple, thermal loss, and noises and improving control performances. Theoretical approach to this voltage-current controller is performed, and the results are presented.

  • PDF

A Simplified Modulation Strategy for Three-leg Voltage Source Inverter Fed Unsymmetrical Two-winding Induction Motor

  • Sinthusonthishat, Saliltip;Chuladaycha, Nontawat
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1337-1344
    • /
    • 2013
  • This paper presents a simplified modulation strategy for the three-leg VSI fed two-winding induction motor. The strategy provides independent unbalanced voltage control for the main and auxiliary windings. This make the motor can be reversed rotation through the range of motor speed operation without limitation of voltage boost of the auxiliary winding. To study the advantages of the proposed drive, the experimental results such as voltage stresses, hysteresis band of the currents in locus, and also acoustic noise levels of the three-leg VSI are compared with those of the conventional two-leg topology. The results obviously show that the proposed technique achieves superior performance compared with the traditional scheme in case of dramatic increase of DC bus utilization, effective reduction of harmonic voltages content, and also significant enhancement of motor efficiency.

램프 인식 기능을 가진 HID 전자식 안정기의 구현 (HID Electronic Ballast with Auto-Switching of MH and HPS Lamps)

  • 이치환;최남열
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.887-890
    • /
    • 2004
  • This paper presents a microprocessor controlled electronic ballast for HID lamps, which gives automatic switching between MH and HPS lamps. Lamp identification is carried out by checking variation of lamp impedance at warm-up phase. Direct spread spectrum is done by applying 1 kHz triangular wave for removing acoustic resonance. This frequency modulation of 1 kHz gives also low EMI level. The microprocessor controls the voltage of DC-bus, the voltage of ignition pulses, the power of output. A 250W electronic ballast is implemented with ATmega16 CPU.

  • PDF