• Title/Summary/Keyword: DC Voltage unbalance

Search Result 69, Processing Time 0.025 seconds

Novel Switching Strategy of 1MVar STATCON using Cascade Multilevel Voltage Source Inverter for FACTS Application (FACTS 적용을 위한 직렬형 멀티레벨 전압형 인버터를 사용한 1MVar STATCON의 새로운 스위칭기법)

  • Min, Wan-Gi;Min, Jun-Gi;Choe, Jae-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.12
    • /
    • pp.691-700
    • /
    • 1999
  • This paper proposes a novel switching strategy of 1Mvar STATCON using cascade multilevel H-bridge inverter(HBI) for FACTS application. To control the reactive power instantaneously, the d-q dynamic system model is described and analyzed. A single pulse pattern based on the SHEM(Selective Harmonic Elimination Method) technique is determined from the look-up table to reduce the line current harmonics and a rotating fundamental frequency switching scheme is presented to adjust the DC voltage of each inverter capacitor at the same value. So the voltage unbalance problem between separately DC bus voltage is improved by using the proposed switching scheme. As a result, the presented inverter configuration not only reduces the system complexity by eliminating the isolation at the AC input side transformer but also improves the dynamic response to the step change of reactive power.

  • PDF

The Improvement of Control Scheme for AC-DC-AC Converter Considering Input Voltage Unbalance (입력전원 불평형을 고려한 AC-DC-AC 컨버터 제어 특성 개선)

  • 현동석
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.335-338
    • /
    • 2000
  • 최근에는 기존의 인버터시스템 전원으로 사용되던 다이오드정류기 또는 위상제어정류기의 단점을 개선하고 고속운전에 따르는 제어전압의 부족을 해결하기 위해 3상 PWM 컨버터의 사용이 증가하고 있는 추세이나 3상 PWM 컨버터의 제어는 입력전원이 평형일 경우를 전제로 하고 있다. 그러나 불평형전원은 실제 산업현장에서 빈번히 일어나는 현상으로 입력전원이 불평형이 되면 역상분전압에 의해 THD가 증가하고 직류링크전압에 저차 고조차성분이 나타나게 되므로 인버터의 성능에 악영향을 준다. 따라서 본 연구에서는 입력전원의 불평형에 따른 AC-DC-AC 컨버터의 문제점을 해결할 수 있는 효율적인 제어기법을 제시하는 것을 목적으로 하고 있다.

  • PDF

The Implementation of Current Compensation Controller in Driving Voltage type Converter considering the Unbalance of Reactor at the Source Side (전원측 리액터 불평형을 고려한 전압형 컨버터의 전류 보상 제어기 구현)

  • Chun Ji-Yong;Cho Yu-Hwan;Lee Geun-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.5
    • /
    • pp.413-420
    • /
    • 2004
  • In this paper, the control algorithm of DC source device for inverter starting is proposed and the control method for compensating unbalance system source on operating time in the voltage type PWM converter with driving and regenerative faculty is suggested. The maintaining method of balancing condition for converter of AC source is used the compensating unbalanced status by current control loop. In order to solve the problem which the unbalanced system control is used to leakage transformer not equaled reactance by each phase in rectifier system. The proposed H/W and control algorithm of rectifier system is contributed to minimize of device and rising efficiency.

  • PDF

A Grid Current-Controlling Shunt Active Power Filter

  • Tumbelaka, Hanny H.;Borle, Lawrence J.;Nayar, Chemmangot V.;Lee, Seong-Ryong
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.365-376
    • /
    • 2009
  • In this paper, the implementation of a three-phase shunt active power filter is presented. The filter is essentially three independent single-phase current-controlled voltage source inverters (CC-VSI) with a common DC bus. The CC- VSI is operated to directly control the AC grid current to be sinusoidal and in phase with the grid voltage without detecting the load currents. The APF consists of a current control loop, which shapes the grid currents to be sinusoidal and a voltage control loop, which regulates the active power balance of the system. The experimental results indicate that the active filter is able to handle predominantly the harmonics, as well as the unbalance and reactive power, so that the grid currents are sinusoidal, in phase with the grid voltages and symmetrical.

Operating Method of 3 Phase Voltage type PWM Converter for Unbalanced Voltage with Leakage Transformer (누설변압기가 부착된 전원 불평형 3상 전압형 PWM 컨버터 운전법)

  • Chun, Ji-Yong;Kim, Young-Chun;Cho, Yu-Hwan;Lee, Keun-Hong
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.125-127
    • /
    • 2005
  • In this paper, the control algorithm of DC source device for inverter starting is proposed and the control method for compensating unbalance system source on operating time in the voltage type PWM converter with driving and regenerative faculty is suggested. The maintaining way of balancing condition for converter of AC source is used the compensating unbalanced status by current control loop. Because it is possible that the unbalanced System control is used to leakage transformer not equaled reactance by each phase in rectifier system, the proposed H/W and control algorithm of rectifier system is contributed to minimize of device and rising efficiency.

  • PDF

Neutral-point Potential Balancing Method for Switched-Inductor Z-Source Three-level Inverter

  • Wang, Xiaogang;Zhang, Jie
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1203-1210
    • /
    • 2017
  • Switched-inductor (SL) Z-source three-level inverter is a novel high power topology. The SL based impedance network can boost the input dc voltage to a higher value than the single LC impedance network. However, as all the neutral-point-clamped (NPC) inverters, the SL Z-source three-level inverter has to balance the neutral-point (NP) potential too. The principle of the inverter is introduced and then the effects of NP potential unbalance are analyzed. A NP balancing method is proposed. Other than the methods for conventional NPC inverter without Z-source impedance network, the upper and lower shoot-through durations are corrected by the feedforward compensation factors. With the proposed method, the NP potential is balanced and the voltage boosting ability of the Z-source network is not affected obviously. Simulations are conducted to verify the proposed method.

Algorithm on the power Cell AVR(Auto Voltage Regulation) of H-Bridge Multi-level Inverter (H-bridge 멀티-레벨 인버터의 파워Cell AVR에 관한 알고리즘)

  • Jeon, J.H.;Yun, H.M.;Kim, M.K.;Lee, J.P.;Jang, D.J.;Na, S.H.;Kwon, B.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.317-320
    • /
    • 2005
  • 본 논문은 멀티-레벨 H-bridge 인버터에서 입력전압 변동에 따른 AVR(Auto Voltage Regulation)기능을 적용 그 타당성을 제안하였다. 기존의 범용 인버터에서 (V/F)로 구동되는 전동기 시스템에 있어서 인버터에 공급되는 입력 전압은 출력 주파수에 따라 출력 전압 비율을 일정하게 하고 기동에 필요한 전압을 더하여 출력하는 방식이다. 집중 제어 방식의 멀티-레벨 H-bridge 인버터에서는 Cell의 DC-Link 전압을 Master에서 받아들여서 각각의 Cell에 기준 전압값을 지령하게 된다. 그러므로 입력 전압 변동에 따른 DC-Link 전압의 변동이 발생하게 되면 상전압 Unbalance 가 발생하게 되어 부하가 원하는 출력 전압을 낼 수가 없게 된다. 또한 각각의 Cell을 제어하는 Master 제어기가 가지고 있는 문제점을 보완하여 각각의 Cell 제어기 스스로가 AVR을 수행하는 좀더 나은 방법을 제안하였다.

  • PDF

Study on PWM Converter Control under Unbalanced Network Condition

  • Sastrowijoyo, Fajar;Choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.524-526
    • /
    • 2011
  • This paper focuses on study on PWM converter control under unbalanced network condition. Voltage unbalance in a three-phase system causes the performance deterioration by producing 120 Hz voltage ripples in the DC link and 120 Hz ripple in reactive power. To eliminate the ripples, both positive and negative sequence currents should be controlled simultaneously. In this paper four PI controllers on synchronous reference frame is implemented to control D and Q currents in both positive and negative sequence. Positive and negative sequence signal extraction is done using delay signal cancellation method. Simulation results show satisfactory performance in suppressing 120 Hz ripples.

  • PDF

Improving the Dynamic Performance of Distribution Electronic Power Transformers Using Sliding Mode Control

  • Hooshmand, Rahmat-Allah;Ataei, Mohammad;Rezaei, Mohammad Hosein
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.145-156
    • /
    • 2012
  • These days, the application of electronic power transformers (EPTs) is expanding in place of ordinary power transformers. These transformers can transmit power via three or four wire converters. Their dynamic performance is extremely important, due to their complex structure. In this paper, a new method is proposed for improving the dynamic performance of distribution electronic power transformers (DEPT) by using sliding mode control (SMC). Hence, to express the dynamic characteristics of a system, different factors such as the voltage unbalance, voltage sag, voltage harmonics and voltage flicker in the system primary side are considered. The four controlling aims of the improvement in dynamic performance include: 1) maintaining the input currents so that they are in sinusoidal form and in phase with the input voltages so they have a unity power factor, 2) keeping the dc-link voltage within the reference amount, 3) keeping the output voltages at a fixed amount and 4) keeping the output voltages in sinusoidal and symmetrical forms. Simulation results indicate the potential and capability of the proposed method in improving DEPT behavior.

The Gyro High Voltage Power Supply Design for Attitude Control in the Satellite (저궤도 위성 자세제어용 자이로 고전압 발생기 설계)

  • Kim, Eui-Chan;Lee, Heung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.3
    • /
    • pp.403-408
    • /
    • 2008
  • The gyroscope is the sensor for detecting the rotation in inertial reference frame and constitute the navigation system together an accelerometer. As the inertial reference equipment for attitude determination and control in the satellite, the mechanical gyroscope has been used but it bring the disturbance for mass unbalance so the disturbance give a bad influence to the observation satellite mission because the mechanical gyroscope has the rotation parts. During the launch. The mechanical gyroscope is weak in vibration, shock and has the defect of narrow operating temperature range so it need the special design in integration. Recently the low orbit observation satellite for seeking the high pointing accuracy of image camera payload accept the FOG(Fiber Optic Gyro) or RLG(Ring Laser Gyro) for the attitude determination and control. The Ring Laser Gyro makes use of the Sanac effect within a resonant ring cavity of a He-Ne laser and has more accuracy than the other gyros. It need the 1000V DC to create the He-Ne plasma in discharge tube. In this paper, the design process of the High Voltage Power Supply for RLG(Ring Laser Gyroscope) is described. The specification for High Voltage Power Supply (HVPS) is proposed. Also, The analysis of flyback converter topology is explained. The Design for the HVPS is composed of the inverter circuit, feedback control circuit, high frequency switching transformer design and voltage doubler circuit.