• 제목/요약/키워드: DC Trends

검색결과 46건 처리시간 0.022초

전자식 및 자기식 안정기 동시 호환 가능한 LED 구동회로 (LED Driver Compatible with Both Electronic and Magnetic Ballasts)

  • 구현수;최윤;강정일;한상규
    • 전력전자학회논문지
    • /
    • 제21권1호
    • /
    • pp.42-48
    • /
    • 2016
  • Light-emitting diode (LED) drivers are recently replacing fluorescent lamps; these drivers can operate adaptively with various ballasts without modifying and removing such ballasts. To satisfy these trends, a LED driver that is compatible with both electronic and magnetic ballasts is proposed in this study. Unlike conventional LED drivers, the proposed driver has a ballast recognition circuit and a mode selection circuit to operate ballasts at optimal conditions. Therefore, it features low voltage stress, high efficiency, and good compatibility with both electronic and magnetic ballasts. Moreover, it can be compatible with a wide selection of ballasts from various manufacturers. To confirm the validity of the proposed LED driver, results of the theoretical analysis and experimental verification performed on a 15 W-rated prototype are presented.

관절가동범위 측정 기능을 갖는 연속수동운동 의료기기 시스템 설계 (Design of Continuous Passive Motion Medical Device System with Range of Motion Measurement Function)

  • 이강원;박민수;유도우;양오;이창호
    • 반도체디스플레이기술학회지
    • /
    • 제22권4호
    • /
    • pp.87-92
    • /
    • 2023
  • As the elderly population increases, the number of patients with various joint diseases, including degenerative arthritis, is steadily increasing. CPM medical devices are needed to effectively treat degenerative arthritis that is common in the elderly population. Domestic CPM medical devices have limited functions and are highly dependent on imports for expensive imported medical devices. To solve this problem, we designed a ROM measurement function using a current sensor that is not present in existing composite joint CPM medical devices. The algorithm was designed using the fact that the force caused by joint stiffness greatly increases the current flowing through the DC motor. In addition, the need for digital healthcare in the medical field is gradually expanding as the proportion of chronically ill patients increases due to the spread of the non-face-to-face economy due to COVID-19 and the aging population. Therefore, this paper aims to improve the performance of CPM medical devices by allowing real-time confirmation of rehabilitation exercise information and operation range measurement results in accordance with digital healthcare trends through a Bluetooth application developed as an Android studio.

  • PDF

CM산업 수주실적 분석을 통한 CM기업의 발전 방안 - 1997년 ~ 2014년 실적자료 기반 - (CM Prospects and Strategies Based on Contract Statistics : 1997 through 2014)

  • 하지원;정영수
    • 한국건설관리학회논문집
    • /
    • 제17권5호
    • /
    • pp.97-107
    • /
    • 2016
  • 지난 18년간 우리나라 CM산업은 많은 발전을 이루어 왔으며, 최근 국내 건설투자가 감소하는 환경변화 속에서도 CM사업 고도화 및 해외시장에서의 기술과 경쟁우위를 통한 수주 확대를 위한 활발한 노력이 이루어지고 있다. 이에 본 연구는, 1997년부터 2014년까지의 3,453건의 CM사업 수주실적 통계자료를 수주지역, 계약규모, 발주자유형, 공종유형의 4가지 분석변수를 통해 연도별 시간별 시계열 분석을 하였다. 분석결과, 우리나라 CM산업의 시장규모는 최근 2005년 대비 2010년 2.5배 증가하였으며, 국내 CM사업의 수주비중이 87.5%, 공종별로는 건축분야가 88.4%, 계약규모별로는 10억미만의 CM사업이 75%로 CM수주 집중도가 높았다. 그러나 최근 국내 CM기업의 향상된 기술 및 수주경쟁력으로 인해, 2010~2014년 해외 CM사업 비중이 20%까지 크게 증가하였으며, 포괄적이며 기술적인 사업관리업무를 요구하는 민간발주자에 의한 CM사업도 3배나 증가하였다. 이와 같은, CM산업환경 및 사업유형의 변화는 향후 해외민간(IC5) CM사업 수주확대로의 발전경로(Jung et al. 2014)에 놓인 DP3와 DC2의 정량적 분석을 통해서도, 공공사업 부분용역형 CM사업 중심에서 생애주기를 고려한 종합관리형 민간사업 형태로 발전되고 있는 것으로 분석되었다.

Size-sorting of Micron-sized Particles using Two Gravitational SPLITT Fractionation (GSF) Connected in a Series (Tandem GSF)

  • Kwon, Min-Hyuk;Moon, Yoon-Jung;Jung, Euo-Chang;Lee, Kyou-Ho;Lee, Seung-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권2호
    • /
    • pp.681-686
    • /
    • 2011
  • SPLITT Fractionation (SF) provides separation of sample into two subpopulations. Separation into more than two subpopulations requires repeated SF operations. In this study, two Gravitation SF (GSF) channels were connected in a series (Tandem GSF) to obtain a separation into three subpopulations and to improve the fractionation efficiency (FE) of the fraction-b in the full-feed depletion (FFD) mode. In a single channel FFD-GSF operation, the fraction-a contained mostly the beads smaller than the cutoff diameter ($d_c$), while the fraction-b contained beads smaller than $d_c$ as well as those larger than dc, as expected. The measured FE's of the fraction-b are much lower than those of the fraction-a in all cases. The FE's of the fraction-a are higher than 84% with the average of about 91%, while those of the fraction-b are lower than 60% with the average of about 43%. No particular trends were found between FE and $d_c$, indicating the performance of FFD-GSF does not change with $d_c$ in the range where tested. Also no clear trends were observed between the FE and the sample-feeding flow rate, indicating higher sample-feeding rate can be used to increase the sample throughput without losing resolution. When two GSF channels were connected so that the flow stream emerging from the outlet-b of the channel-1 is fed directly into the channel-2, all three FE's measured for the fraction-1a were high with the average value of 99%, indicating it contains almost purely the beads smaller than $d_c$. The FE's measured for the fraction-2a are still good with the average value of 92%. The FE's measured for the fraction-2b are 64% in average, which is about 20% improvement from those obtained in a single channel FFD-GSF at the same conditions.

The surface kinetic properties between $BCl_3/Cl_2$/Ar plasma and $Al_2O_3$ thin film

  • Yang, Xue;Kim, Dong-Pyo;Um, Doo-Seung;Kim, Chang-Il
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.169-169
    • /
    • 2008
  • To keep pace with scaling trends of CMOS technologies, high-k metal oxides are to be introduced. Due to their high permittivity, high-k materials can achieve the required capacitance with stacks of higher physical thickness to reduce the leakage current through the scaled gate oxide, which make it become much more promising materials to instead of $SiO_2$. As further studying on high-k, an understanding of the relation between the etch characteristics of high-k dielectric materials and plasma properties is required for the low damaged removal process to match standard processing procedure. There are some reports on the dry etching of different high-k materials in ICP and ECR plasma with various plasma parameters, such as different gas combinations ($Cl_2$, $Cl_2/BCl_3$, $Cl_2$/Ar, $SF_6$/Ar, and $CH_4/H_2$/Ar etc). Understanding of the complex behavior of particles at surfaces requires detailed knowledge of both macroscopic and microscopic processes that take place; also certain processes depend critically on temperature and gas pressure. The choice of $BCl_3$ as the chemically active gas results from the fact that it is widely used for the etching o the materials covered by the native oxides due to the effective extraction of oxygen in the form of $BCl_xO_y$ compounds. In this study, the surface reactions and the etch rate of $Al_2O_3$ films in $BCl_3/Cl_2$/Ar plasma were investigated in an inductively coupled plasma(ICP) reactor in terms of the gas mixing ratio, RF power, DC bias and chamber pressure. The variations of relative volume densities for the particles were measured with optical emission spectroscopy (OES). The surface imagination was measured by AFM and SEM. The chemical states of film was investigated using X-ray photoelectron spectroscopy (XPS), which confirmed the existence of nonvolatile etch byproducts.

  • PDF

광조사 시간이 접착제의 표면 미중합층의 두께와 전단접착강도에 미치는 영향에 관한 연구 (Influence of the curing time for the adhesive on the oxygen-inhibited layer thickness and the shear bond strength to dentin)

  • 최용훈;배지현;손호현;이인복;백승호;엄정문;김오영;김창근;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제29권2호
    • /
    • pp.177-184
    • /
    • 2004
  • 본 연구는 광중합형 상아질 접착제에서 광조사 시간의 증가가 접착제 표면의 미중합층에 대한 영향과 그에 따른 전단접착강도에 대해 연구하고자 120개의 치아를 아크릴 몰드에 식립한 후 상아질이 노출되도록 연마하였다. 3종류의 접착제 〔All Bond2 (AB2), One-Step (OS) and Adper Prompt (AP)〕를 40개 치아에 제조사의 지시대로 도포한 후 각각 다른 광조사 시간 (10, 20, 30 and 60sec)동안 광조사 하고 복합레진을 접착한 24시간 후 전단접 착강도를 측정하였다. 미중합층의 두께와 중합률은 슬라이드 글라스와 FT-NIR을 이용하여 FT-NIR spectrum에서의 peak height를 비교 측정하여 다음과 같은 결론을 얻었다. 1. 전단접착강도에서 AB2는 20초 이후 감소하고, AP는 30초까지 증가하였으며,OS는 차이를 보이지 않았다. 2. 미중합층 두께는 3가지 접착제 모두 유의성 있는 차이를 보이지 않았다. 3. 중합률에서 OS는 10초와 나머지군 사이에 유의성 있는 차이를, AP는 60초에서 유의성 있게 증가되고, AB2의 경우 차이를 나타내지 않았다.