• Title/Summary/Keyword: DC GIL

Search Result 126, Processing Time 0.035 seconds

A Study on Charging Efficiency Variability by Utilizing Remaining Capacity of EV DC Charging Facility Batteries of Railway Electric Power Grids (철도전력망을 이용한 EV DC 충전설비 배터리 잔존용량에 따른 충전효율 가변성 연구)

  • Kim, Ki-Suk;Jung, Ho-Sung;Park, Young;Park, Chan-Bae;Park, Chul-Min;Jang, Gil-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2171-2172
    • /
    • 2011
  • Recently, while interests on supply of electric vehicles have increased there still are insufficient charging facilities. As a solution to this matter, using electric power grids that constantly retain about 30~50[%] residual power is being considered. Therefore proposed in this paper railway, is a method to establish a charging infrastructure to utilize railway DC power grids. In addition we designed a high-speed DC charging system, and simulated improvements of the charging structure's charging efficiency according to remaining capacity of batteries.

  • PDF

A study on the application of urban railway DC electric power for electric car charging system (전기차 충전시스템을 위한 도시철도 DC 전력의 활용방안 연구)

  • Kang, Hyun-Il;Kin, Youn-Sik;Sim, Jae-Suk;Im, Hyeong-Gil;Ryu, Ki-Seon;Lee, Gi-Seung
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1855-1860
    • /
    • 2010
  • Electric vehicles have reached a new level of development with introductions by Chrysler, Ford, Honda and Toyota. Today's charging technology includes conductive and inductive charging systems. There are three standardized charging levels: Level 1: charging can be done from a standard, grounded AC 120V, 3-prong outlet available in all homes; Level 2: charging is at AC 240V, 40 amp charging station with special consumer features to make it easy and convenient to plug in and charge EVs at home or at an EV charging station; Level 3: a high-powered charging "fast charge" technology currently under development that will provide a charge in less than 15 minutes. The incoming AC power is converted to DC and stored in the vehicle's batteries. In this paper, we investigated the application of urban railway DC electric power for electric car charging system.

  • PDF

A Study on Current Driven Synchronous Rectifier of LLC Resonant Half-bridge dc-dc Coverter (LLC 공진형 하프브릿지 dc-dc 컨버터의 전류구동형 동기정류기에 관한 연구)

  • Jin, Gi-Seok;Yu, Gyeong-Bu;Gil, Yong-Man;Ahn, Tae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1010-1011
    • /
    • 2015
  • 최근 고효율 전력변환을 위해 LLC 공진형 하프브릿지 컨버터의 동기정류기에 대한 연구가 활발히 진행되고 있다. 기존 일반적인 다이오드 정류기를 사용하는 경우 출력전류에 비례하는 전력손실이 커서 대전력용으로 사용하기에는 적합하지 않다. 따라서 스위치를 이용한 동기정류기가 검토되고 있는데 동기정류기의 스위치를 구동시키기 위해서는 스위치를 구동시킬 수 있는 구동용 IC가 이용되고 있다. 동기정류기 구동 IC의 단점으로는 약 50%의 중부하 이하에서는 동작되지 않는 단점이 있어 이를 보완하기 위하여 변압기 1차측 전류를 검출하여 게이트 전압을 만들어 스위치를 구동시키는 회로를 제안하였다. 본 논문의 실험 결과 저전력 지점에서 동기정류기가 구동되었고 따라서 전력변환 효율은 기존의 다이오드 정류기에 비해 우수하며 효율개선효과가 있다는 것을 실험으로 보였다.

  • PDF

A Study on the DC Leakage Current Test for Power Cable of Private Electrical Facilities considering Lightning Arrester (피뢰기를 고려한 자가용 전기설비 인입선로의 직류누설전류시험에 관한 연구)

  • Jeong, Ki-Seok;Gil, Hyoung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.142-147
    • /
    • 2018
  • Private electrical facilities are judged whether it is suitable for the insulation aging condition of their incoming underground cables using DC leakage current test method. In the case where the service point of utility is the secondary side of cut out switch installed in the electric pole, there is a problem that it is difficult to separate the lightning arresters(LA) because of their high position of the pole. Therefore, the field test voltage is applied at value lower than DC 30 kV, which are stated in the inspection guideline. However, this test could reduced the insulation performance of the LA by accelerating the electrical stress of the metal oxide varistor element in the pre-breakdown region. In this study, we analyzed the relationship between the DC test voltage and the leakage current using the non-destructive DC high voltage equipment with leakage current measurement function. The results show that the leakage current increases sharply above the specified test voltage. As a consequence, it could be contributed to improve insulation aging inspection method by selecting the possible test area on the VI characteristic curve of the pre-breakdown area of the LA.

A Comparative Study on the Effect of Cupping Therapy Combined with Korean Medicine Treatment in Peripheral Facial Paralysis

  • Choi, Chul-Hoon;Kim, Deok-Hyun;Song, Ho-Sueb
    • Journal of Acupuncture Research
    • /
    • v.35 no.4
    • /
    • pp.187-192
    • /
    • 2018
  • Background: The aim of this study was to compare the effects of different cupping therapy methods combined with Korean medicine treatments for peripheral facial paralysis. Methods: 105 patients treated for peripheral facial paralysis with cupping therapy and other Korean medicine treatment at Gil Korean medicine hospital, Gachon University between May 19, 2014 and June 30, 2018 were selected and their medical charts retrospectively analyzed. 48 patients who met the inclusion criteria were divided into 2 groups: wet cupping (WC) therapy, or dry cupping (DC) therapy combined with Korean medicine treatment. The duration of treatment ranged from 2 weeks for inpatient treatment to 2 months for outpatient treatment. Both WC and DC therapy were performed on TE13, 3 times per week during the treatment period. The effect of cupping therapy was evaluated by using the Gross Grading System of the House-Brackmann (HB score) and the Yanagihara's Unweighted Grading System (Y score). Results: For both WC and DC treatment of symptoms related to peripheral facial paralysis, HB scores showed a significant decrease and Y scores showed a significant increase from baseline to end of treatment, indicating a beneficial improvement in patient symptoms for both WC and DC. Conclusion: In this study, both DC and WC treatment had significant improvements on peripheral facial paralysis symptoms, with WC having significantly greater beneficial effects than DC.

Secure Block Cipher Algorithm for DC and LC (DC와 LC에 안전한 SPN 구조 암호 알고리즘)

  • Choe, Eun-Hwa;Seo, Chang-Ho;Seong, Su-Hak;Ryu, Hui-Su;Jeon, Gil-Su
    • The KIPS Transactions:PartC
    • /
    • v.9C no.4
    • /
    • pp.445-452
    • /
    • 2002
  • In this paper, we suggest the design of 128bit block cipher which is provable security based on mathematics theory. We have derived the 16$\times$16 matrix(i.e.,linear transformation) which is numerous active S-box, and we proved for DC and LC which prove method about security of SPN structure cipher algorithm. Also, the minimum number of active S-box, the maximum differential probabilities and the maximum linear probabilities in round function of 128bit block cipher algorithm which has an effect to DC and LC are derived.

A Study on Utility Interactive Energy System using PWM Converter (PWM 컨버터를 이용한 계통연계 에너지시스템에 관한 연구)

  • Kim, Gil-Dong;Lee, Han-Min;Hong, Yong-Ki;Kim, Dea-Gyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.288-291
    • /
    • 2007
  • Since the residential load is an AC load and the output of solar cell is a DC power, the photovoltaic system needs the DC/AC converter to utilize solar cell. In case of driving to interact with utility line, in order to operate at unity power factor, converter must provide the sinusoidal wave current and voltage with same phase of utility line. Since output of solar cell is greatly fluctuated by insolation, it is necessary that the operation of solar cell output in the range of the vicinity of maximum power point. In this paper, DC/AC converter is three phase PWM converter with smoothing reactor. And then, feedforward control used to obtain a superior characteristic for current control and digital PLL circuit used to detect the phase of utility line.

  • PDF

Estimation of Upstream Ungauged Watershed Streamflow using Downstream Discharge Data (하류 유량자료를 이용한 상류유역의 미계측 유출량 추정)

  • Jung, Young Hun;Jung, Chung Gil;Jung, Sung Won;Park, Jong Yoon;Kim, Seong Joon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.6
    • /
    • pp.169-176
    • /
    • 2012
  • This study describes the estimation of upstream ungauged watershed streamflow using downstream discharge data. For downstream Dongchon (DC) and upstream Kumho (KH) water level stations in Kumho river basin ($2,087.9km^2$), three methods of Soil and Water Assessment Tool (SWAT) modeling, drainage-area ratio method and regional regression equation were evaluated. The SWAT was calibrated at DC with the determination coefficient ($R^2$) of 0.70 and validated at KH with $R^2$ of 0.60. The drainage-area ratio method showed $R^2$ of 0.93. For the regional regression, the watershed area, average slope, and stream length were used as variables. Using the derived equation at DC, the KH could estimate the flow with maximum 41.2 % error for the observed streamflow.

Verification of Hybrid Real Time HVDC Simulator in Cheju-Haenam HVDC System

  • Yang Byeong-Mo;Kim Chan-Ki;Jung Gil-Jo;Moon Young-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.23-27
    • /
    • 2006
  • In this paper a Hybrid Real Time HVDC Simulator fur both operator Training and Researching in the Cheju-Haenam HVDC System is proposed and its performance is studied by means of RTDS (Real Time Digital Simulator), EMTDC (Electro-Magnetic Transients system for DC), PSS/E (Power System Simulator for Engineering), and experienced scenarios. The objective of this paper is to represent the strategy in development for KEPCO's hybrid HVDC simulator for the Cheju-Haenam HVDC system. This simulator consists of two DC stations, DC cables, external digital/analog controllers, monitoring systems and control desk for education, and AC networks. Its suitability for operator's education is tested during startup/shutdown and normal state operations. Dynamic performances of it are also verified.