• Title/Summary/Keyword: DC Distribution System

Search Result 319, Processing Time 0.031 seconds

A Droop Control for the Autonomous Operation of DC Distribution System using Grid-tied Converter and Energy Storage (직류급전 시스템의 Autonomous Operation을 위한 교류연계장치와 에너지 저장의 Droop Control)

  • Lee, Ji-Heon;Cha, Min-Young;Han, Byung-Moon
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.32-33
    • /
    • 2010
  • This paper describes a droop control method for the autonomous operation of DC distribution system using distributed generations and energy storage. The method suppress the circulating current, and each unit could be controlled autonomously without communication system. Detailed model of wind power generation, photo-voltaic generation, fuel-cell generation and battery was implemented with the user-defined model of PSCAD/EMTDC software that is coded with C-language. The simulation and experimental results confirms that the proposed DC distribution system make it feasible to provide power to the load stably and verify effectiveness of the proposed method.

  • PDF

The design of adaptive Controller for the Voltage Bus Conditioner for the improvement of the Power Quality in the DC Power Distribution System (DC 배전시스템의 품질향상을 위한 VBC 적응제어)

  • Woo, Hyun-Min;Lee, Byung-Hun;Chang, Han-Sol;La, Jae-Du;Kim, Young-Seok
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2348-2356
    • /
    • 2011
  • In recent years, many researches for DC power distributed system (PDS) are being preformed and the importance of the DC PDS is more and more emphasized. Furthermore, in the railway system, the DC PDS is used in subway station lighting, facilities, etc. In the DC PDS, DC bus voltage instability may be occurred by the operation of multiple parallel loads such as pulsed power load, motor drive system, and constant power loads. Thus, good quality and high reliability for electric power are required and voltage bus conditioner (VBC) may be used the DC PDS. The VBC is a DC/DC converter for mitigation of the bus transients. In this paper, adaptive controller is designed. The simulation results by PSIM are presented for validating the proposed control algorithm.

  • PDF

A Study on the Development of a Variable Speed Diesel Generator for DC Distribution (직류배전용 가변속 디젤발전기 개발에 관한 연구)

  • Park, Kido;Kim, Jongsu
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.1
    • /
    • pp.117-121
    • /
    • 2019
  • In this study, research and a demonstration for applying DC distribution systems to ships as an environmental and energy conservation solution in domestic and foreign countries were actively carried out. In order to apply a generator to a DC distribution system, a variable speed engine was used. Both engine speed and fuel consumption were reduced. In this paper, a DC generator for DC distribution was constructed using a diesel generator, a generator controller, a governor, and an AVR. A system configuration method for a generator, power quality test, and the power characteristics of a variable speed generator were analyzed. The voltage (250 - 440 VAC) and frequency (34 - 60 Hz) of the variable speed generator were set to 60 - 100 % of the rated value, and the engine was set to operate from 1100 - 1800 rpm. It was confirmed that the voltage, current, and frequency of the generator output fluctuated in a stable manner according to the power amount when changing the engine speed of the generator according to the load variation.

Development of Fault Detector for Series Arc Fault in Low Voltage DC Distribution System using Wavelet Singular Value Decomposition and State Diagram

  • Oh, Yun-Sik;Han, Joon;Gwon, Gi-Hyeon;Kim, Doo-Ung;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.766-776
    • /
    • 2015
  • It is well known that series arc faults in Low Voltage DC (LVDC) distribution system occur at unintended points of discontinuity within an electrical circuit. These faults can make circuit breakers not respond timely due to low fault current. It, therefore, is needed to detect the series fault for protecting circuits from electrical fires. This paper proposes a novel scheme to detect the series arc fault using Wavelet Singular Value Decomposition (WSVD) and state diagram. In this paper, the fault detector developed is designed by using three criterion factors based on the RMS value of Singular value of Approximation (SA), Sum of the absolute value of Detail (SD), and state diagram. LVDC distribution system including AC/DC and DC/DC converter is modeled to verify the proposed scheme using ElectroMagnetic Transient Program (EMTP) software. EMTP/MODELS is also utilized to implement the series arc model and WSVD. Simulation results according to various conditions clearly show the effectiveness of the proposed scheme.

Analysis of Steady State and Transient State according to the Number of Pole in LVDC Distribution System (저압직류 배전계통의 극 수에 따른 정상상태 및 과도상태 특성 분석)

  • Song, Jong-Il;Noh, Chul-Ho;Kim, Doo-Ung;Gwon, Gi-Hyeon;Oh, Yun-Sik;Han, Joon;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.383-384
    • /
    • 2015
  • DC system is still unexploited in public distribution systems. As the weight of cost efficiency and reliability requirements of distribution networks are expected to increase in the future, with the utilization of distributed generation, there will be demand for novel distribution techniques. The utilization of the Low Voltage DC (LVDC) distribution system opens new possibilities for network development. This paper presents analysis of steady state and transient state according to the number of pole in LVDC distribution system.

  • PDF

Demonstration of Operating Algorithm for Stabilizing Multi-LVDC Power Grid (다회로 LVDC 전력망 안정화를 위한 운영 알고리즘 실증)

  • Yu-Kyeong Lee;Byung-Woo Park;Chun-Sung Kim;Sung-Jun Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_3
    • /
    • pp.1259-1267
    • /
    • 2023
  • In recent years, as the demand for distributed power has increased, the need for microgrids connected to grid power and renewable power generation sources has emerged. In the case of DC microgrids, reactive power does not occur, and power conversion losses are reduced compared to AC when connecting to the load and power grid[2]. With the revitalization of the DC distribution network industry, various studies and demonstrations of DC microgrids have been carried out. In the case of the recent unit distribution, its stability and effectiveness have been verified through empirical and research analysis. However, there is a lack of empirical tests to prevent chain accidents for the protection of the power grid circuits and the misoperation of the distributed power system caused by individual accidents when connecting various distributed power sources and power grids. In this paper, the operation plan of a stable multi-circuit DC distribution connection for the demonstration site was verified through the protection cooperation and operation algorithm for the stable linkage management of the DC distribution network composed of such a multi-circuit.

A Model Predictive Control Method of a Cascaded Flying Capacitor Multi-level Rectifier for Solid State Transformer for DC Distribution System (DC 배전용 반도체 변압기를 위한 직렬 연결된 플라잉 커패시터 멀티-레벨 정류기의 모델 예측 제어 방법)

  • Kim, Si-Hwan;Jang, Yeong-Hyeok;Kim, June-Sung;Kim, Rae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.5
    • /
    • pp.359-365
    • /
    • 2018
  • This study introduces a model predictive control method for controlling a cascaded flying capacitor multilevel rectifier used as an AC-DC rectifier of a solid-state transformer for DC distribution systems. The proposed method reduces the number of states that need to be considered in model predictive control by separately controlling input current, output DC link voltage, and flying capacitor voltage. Thus, calculation time is shortened to facilitate the level expansion of the cascaded flying capacitor multilevel rectifier. The selection of weighting factors did not present difficulties because the weighting factors in the cost function of the conventional model predictive control are not used. The effectiveness of the proposed method is verified through computer simulation using powersim and experiment.

Robust Safety Circuits for DC Powered Home Appliances in Transient State

  • Ahn, Jung-Hoon;Kim, Yun-Sung;Lee, Byoung-Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1967-1977
    • /
    • 2014
  • In this paper, for the development of a safe and reliable DC home appliance suitable for DC home power supply system, we classified a number of inherent problems with help of the comparative analysis of existing AC and new DC home appliance. Several new technical problems of DC home appliances are mainly linked to the DC transient state. Among them, this paper concentrates on start-up inrush current problem, uni-polarity problem, and heavy DC load control problem. And to address these problems, we herein present an implementation of robust safety circuits for DC home appliances. Specifically, we investigate several multi-circuit countermeasures and select the best among them through comparative evaluation, based on theoretical, simulational, and experimental results.

A Study on the Hybrid Arc Extinguishing Mechanism of the DC Circuit Breaker (DC 차단기의 하이브리드 아크 소호 기법에 관한 연구)

  • Joo, Nam-Kyu;Kim, Nam-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.3
    • /
    • pp.250-256
    • /
    • 2015
  • Digital load is increasing suddenly for various reasons, such as easy control and management. Accordingly, a consumption pattern of load is becoming DC. However, the power supply is supplied by AC power. The load power supply substantially needs DC power. AC power has to be converted to DC power. Renewable energy sources like solar, wind and fuel cells are DC power generation, but the transfer needs to through by AC power, thus DC power has to be converted to AC power. Resultantly, a multi-stage conversion loss is constantly increasing. The power distribution system of DC-based is required for effective use of these energy sources. This requires a DC load, as well as is necessary to develop DC breaker. This study is expect for system and equipment for reliable DC power distribution through the study of the arc extinguish technology for direct current a hybrid arc extinguishing technology with permanent magnets technology.

The Measurement System of Space Charge Distribution in Polymer Dielectric Materials by the PEA Method (펄스정전응력법(PEA)을 이용한 고분자 유전체 내의 공간전하분포 측정시스템)

  • Hwang, Bo-Seung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.6
    • /
    • pp.1403-1411
    • /
    • 2012
  • In this paper, we have evaluated theoretically the PEA method which is the most popular methods for the non-destructive measurement of space charge distribution in polymer dielectric materials and is recently one of big issues in DC high voltage cables. On the basis of theoretical evaluation, we have developed the space charge measurement system in polymer dielectrics under DC appled voltage and improved the accuracy of space charge distribution by applying the deconvolution process for distorted signals.