• Title/Summary/Keyword: DC Distribution

Search Result 596, Processing Time 0.023 seconds

An Algorithm for Even Distribution of Loss, Switching Frequency, Power of Model Predictive Control Based Cascaded H-bridge Multilevel Converter (모델 예측 제어 기반 Cascaded H-bridge 컨버터의 균일한 손실, 스위칭 주파수, 전력 분배를 위한 알고리즘)

  • Kim, I-Gim;Kwak, Sang-Shin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.5
    • /
    • pp.448-455
    • /
    • 2015
  • A model predictive control (MPC) method without individual PWM has been recently researched to simplify and improve the control flexibility of a multilevel inverter. However, the input power of each H-bridge cell and the switching frequency of switching devices are unbalanced because of the use of a restricted switching state in the MPC method. This paper proposes a control method for balancing the switching patterns and cell power supplied from each isolated dc source of a cascaded H-bridge inverter. The supplied dc power from isolated dc sources of each H-bridge cells is balanced with the proposed cell balancing method. In addition, the switching frequency of each switching device of the CHB inverter becomes equal. A simulation and experimental results are presented with nine-level and five-level three-phase CHB inverter to validate the proposed balancing method.

Development of Corona Cage Measurement System for Simulation on Electrical Environmental Characteristics of HVDC Overhead Transmission Line (HVDC 가공 송전선로 전기환경특성 모의시험용 코로나 케이지 계측시스템 개발)

  • Kil, Gyung-Suk;Yang, Kwang-Ho;Lee, Sung-Doo;Ju, Mun-No
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.5
    • /
    • pp.245-249
    • /
    • 2006
  • Corona characteristics of conductors are dependent on the electric field conditions in the immediate vicinity of the conductors. In case of DC transmission line, particularly, the space charge plays an important role in the electric field distribution. Therefore, DC corona cage simulation is necessary for long-term test in the same conditions. This paper presents the results of designing and constructing hardwares such as DC power supply, measurement system and DAS to carry out the simulation. The corona cage longitudinally is divided into five equal length sections and three inner sections of those are isolated from the ground of outer cage. The measurement items are radio noise, corona current, television noise, audible noise and meteorological conditions. In the next step, various simulations about the type and configuration of two or three candidate conductors will be conducted. And then finally an environmentally-friendly conductor for HVDC overhead transmission line will be decided.

Preparation of Honeycomb-patterned Polyaniline-MWCNT/Polystyrene Composite Film and Studies on DC Conductivity

  • Kim, Won-Jung;Huh, Do-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.7
    • /
    • pp.2345-2351
    • /
    • 2012
  • Conductive honeycomb-patterned polystyrene (PS) thin films were prepared by the formation of a polyaniline (PANI) thin layer on the surface of the patterned PS thin films using simple one-step chemical oxidative polymerization of aniline. The in situ chemical oxidation polymerization of aniline hydrochloride solution on the patterned structure of the PS films was conducted in the presence of multiwalled carbon nanotubes (MWCNT) to prepare the PANI-MWCNT/PS composite film. The concentration (wt %) of MWCNT was varied in the range of 1%-3% by weight. The dependence of surface morphology of the PANI/PS and PANI-MWCNT/PS composite film to the polymerization time was observed by scanning electron microscopy. The room temperature DC conductivity was obtained by the four-probe technique. The conductivity of the PANI-MWCNT/PS composite film was affected both by the MWCNT concentration and polymerization time. In addition, DC electrical field was loaded during the oxidative polymerization to affect the distribution of the MWCNT included in the composite film, varying the loading voltage in the range of 0.1-3.0 V. The conductivity of the PANI-MWCNT/PS composite film was increased as loading voltage rose. However, this increase stops at a voltage higher than the critical value.

Electrical Properties of Low Density Polyethylene Film by Superstructure Change (고차구조 변화에 따른 저밀도폴리에틸렌 박막의 전기적 특성)

  • Shin, Jong-Yeol;Shin, Hyun-Taek;Lee, Soo-Won;Hong, Jin-Woong
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.4
    • /
    • pp.101-109
    • /
    • 2002
  • The electrical properties of polyethylene are changed by the superstructure. Such crystalline polymer as polyethylene or polypropylene changes crystallinity and products spherulite or trans-crystal when it is cooled slowly. In this study, after thermal treatment of LDPE at 100[${circ}C$], in silicone oil for an hour, we made specimens in order of slow cooling, water cooling, quenching according to cooling speed. Also, to study the influence of electrical properties due to the superstructure change, we analyzed physical properties and performed dielectric breakdown experiments using DC and impulse voltage Moreover we measured space charges in bulk using Laser Induced Pressure Pulse(LIPP) method. Trap level of specimen is 0.064[eV] at the low temperature region 0.31[eV] at the high temperature region in DC dielectric strength, 0.03[eV] at the low temperature region 0.0925[eV] at the high temperature region in impulse dielectric strength. As its result shows that the quantity of charges induced from the electrode surface increases with applied voltage time, and the distribution of space charges in samples increases the quantity of charges in proportion to applied voltage.

Space Charge Behavior of Oil-Impregnated Paper Insulation Aging at AC-DC Combined Voltages

  • Li, Jian;Wang, Yan;Bao, Lianwei
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.635-642
    • /
    • 2014
  • The space charge behaviors of oil-paper insulation affect the stability and security of oil-filled converter transformers of traditional and new energies. This paper presents the results of the electrical aging of oil-impregnated paper under AC-DC combined voltages by the pulsed electro-acoustic technique. Data mining and feature extractions were performed on the influence of electrical aging on charge dynamics based on the experiment results in the first stage. Characteristic parameters such as total charge injection and apparent charge mobility were calculated. The influences of electrical aging on the trap energy distribution of an oil-paper insulation system were analyzed and discussed. Longer electrical aging time would increase the depth and energy density of charge trap, which decelerates the apparent charge mobility and increases the probability of hot electron formation. This mechanism would accelerate damage to the cellulose and the formation of discharge channels, enhance the acceleration of the electric field distortion, and shorten insulation lifetime under AC-DC combined voltages.

Effects of electrode configurations on uniformity of copper films on flexible polymer substrate prepared by ECR-MOCVD (ECR-MOCVD에 의해 연성 고분자 기판에 제조된 구리막의 균일도에 전극의 형태가 미치는 영향)

  • 전법주;이중기
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.34-46
    • /
    • 2004
  • Copper films were prepared by using ECR-MOCVD(Electron Cyclotron Resonance Metal Organic Chemical Vapor Deposition) coupled with a DC bias system. The DC bias is connected to the electrode which placed 1∼3cm above the polymer substrate. The pulse electrical field around the electrode attracts the positive charged copper ions generated from the dissociation of copper precursor, $Cu(hfac)_2$, under ECR plasma. Condensation of supersaturated copper ions in the space between the electrode and substrate, makes it possible to deposit copper film on the polymer substrate even at room temperature. In this study, optimization of the electrode configuration was carried out in order to obtain the uniform films. The uniformity of the deposited films were closely related to the parameters of electrode geometry such as electrode shape, thickness, grid size and the spacing between electrodes. The most uniform copper film was observed with the electrode that enabled uniform electrical field distribution across the whole dimension of electrode.

A Broad-band Rectenna Using Stub Filter (스터브 필터를 이용한 광대역 렉테나 설계)

  • Oh, Kyoung-Min;Lee, Hyun-Wook;Nam, Hee;Yoon, Ki-Cheol;Hong, Tae-Ui;Lee, Dae-Sung;Hwang, Hak-In;Lee, Jong-Chul
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.4
    • /
    • pp.86-96
    • /
    • 2008
  • In this paper, a new broadband rectenna is presented for the wireless transmission of microwave power. The new broadband rectenna element is based on a new printed monopole broadband antenna with size reduction using surface current distribution and a new broadband stub bandpass filter with suppression of second harmonics. A RF-to-DC conversion efficiency of 80% using a 270 ohm load resistor is obtain at 2.45 GHz. Also, a conversion efficiency of above 50 % is maintained from 1.8 GHz to 2.8 GHz.

  • PDF

Paradoxical Leadership and Proactive Work Behavior: The Role of Psychological Safety in the Hotel Industry

  • KIM, Ji Eun
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.5
    • /
    • pp.167-178
    • /
    • 2021
  • This study aims to identify the influence of paradoxical leadership on proactive work behavior mediated through psychological safety in the hotel industry. This study employs survey data of five-star deluxe hotels in South Korea using convenience sampling. The number of 270 cases was used for analysis and the hypotheses were analyzed with structural equation modeling and AMOS 20. Paradoxical leadership includes five sub-variables of self-centeredness with other-centeredness (SO) distance and closeness (DC), uniformly and individualization (UI), work requirements and flexibility (RF), and decision control and autonomy (CA). The results indicate that DC, UI, and CA positively influence psychological safety. Further, RF and CA make a positive impact on proactive work. Psychological safety fully mediates the effect of DC and UI on proactive work behavior and partially mediates the effect of CA on it. The findings of this study suggest that the impact of paradoxical leadership on proactive work behavior can be strengthened when this relationship is accompanied with psychological safety and other mediation variables for the relationship need to be further investigated. This study suggests how hotel managers enhance the level of proactive work behavior by training themselves to be paradoxical leaders and making psychologically safe environment.

Community Economic Evaluation and Sample Distribution of a State Park: The Case of the Belum Royal State Park, Malaysia

  • AWANG MARIKAN, Dayang Affizzah;RAMBELI, Norimah;AZMAN, Nur Ain;RAMDAN, Mohamad Rohieszan
    • Journal of Distribution Science
    • /
    • v.20 no.10
    • /
    • pp.19-29
    • /
    • 2022
  • Purpose: This study was conducted to gauge the economic evaluation and sample distribution of conserving the Belum Royal State Park (BRSP) in Perak, Malaysia and to identify factors influencing its use by the community. This study aims to examine community perception on the conservation of the Belum Royal State Park (BRSP) and maximum community's willingness to pay for park entry permits fees. Research design, data and methodology: A questionnaire survey was conducted involving a total of 280 respondents. The study adopted the Dichotomous Choice Contingent Valuation Approach (DC-CVM) and the Logistic Model, to estimate the maximum community's willingness to pay for park entry permits fees. Results: The results established that the factors of respondent's occupation, income, ecotourism influence on the BRSP and maximum entry price, significantly influenced visitors' decision on community's willingness to pay. The average community's willingness to pay was RM9.68 per person. Conclusions: In conclusion, surveillance and patrols in protected areas should be expanded. The extra expense for ensuring safety can be offset through income from ecotourism that should also benefit the local community on economic evaluation and equal distribution on the BRSP.

An Analysis of Insulating Reliability in Epoxy Composites for Molding Materials of PT

  • Yang, Jeong-Yun;Park, Geon-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.09a
    • /
    • pp.43-46
    • /
    • 2001
  • The DC dielectric breakdown of epoxy composites used for transformer was experimented and then its data were simulated by Weibull distribution equation in this study. The more hardener increased the stronger breakdown strength at low temperature because of cross-linked density by the virtue of ester radical, and the breakdown strength of specimens with filler was lower than it of non-filler specimens because it was believed that the adding filler formed interface, charges were accumulated in it, the molecular mobility was raised, the electric field was concentrated, electrons were accelerated and then electron avalanche was early accomplished. From the analysis of Wei bull distribution equation, it was confirmed that as the allowed breakdown probability was· given by 0.1[%], the value of 'applied field was needed to be under 17.20[kV/mm].

  • PDF