• Title/Summary/Keyword: DC Discharge

Search Result 375, Processing Time 0.025 seconds

The Analysis of Light Emissions on Ar DC Glow Discharge under the Atmosphere Pressure (대기압 Ar 직류 글로우 방전에서 인가전압의 파형특성에 따른 광원효율 분석)

  • SO, Soon-Youl
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.865-872
    • /
    • 2019
  • We developed a one-dimensional Ar fluid model running in DC-type applied voltage with a sine and a pulse waveform at the atmosphere pressure. We investigated the light emissions and efficiencies of ${\lambda}_{128nm}$, ${\lambda}_{727nm}$, ${\lambda}_{912nm}$ and ${\lambda}_{966nm}$ from the Ar excited particles. From the results, the light emission of ${\lambda}_{128nm}$ and ${\lambda}_{727nm}$ in the applied voltage with a sine waveform were almost two times as in DC voltage type. The shorter the switching time of applied voltage was, the more the light emissions of ${\lambda}_{128nm}$ and ${\lambda}_{727nm}$ were. We discussed the power consumption and Joule heating by charged particles.

DC Traction Regenerative Energy Storage Devices using Super-capacitor (슈퍼 커패시터를 이용한 직류철도 회생에너지 저장장치)

  • Kim, Jong-Yoon;Jung, Doo-Yong;Jang, Su-Jin;Lee, Byoung-Kuk;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.247-256
    • /
    • 2008
  • Regenerative energy generated by regenerative braking of DC traction can cause the system malfunction or damage to the rectifier, or malfunction of the power conversion device in power supply system by DC Line voltage rise in feeder line. Regenerative energy storage system using super capacitor is one of the ways to stabilize DC line voltage. In this paper, energy storage system of DC traction system using super-capacitor bank is implemented and using the field measurement data of the station N and the station S on the Line 2, the operation characteristics of line voltage caused by regenerative energy of electric trains are verified. Also, charge/discharge characteristics of super capacitor are verified as well. Thus, we can verify the operation characteristics of super-capacitor bank for regenerative energy storage system installed in DC Traction. And if we can use field measurement data of DC line voltage, we have obtained cost reduction. The stabilization of the system will be improved by measuring the operation characteristics of regenerative energy storage system in certain section operated by DC traction and predicting the capacity and lifetime of super-capacitor.

Effects of Nitrogen Gas Ratio on Nitride Layer and Microhardness of Tool Steel(SKH51) in Plasma Nitriding (플라즈마질화시 방전가스중 질소가스의 비율이 공구강(SKH51)의 질화층 및 미소경도에 미치는 영향)

  • Kim, Deok-Jae;Lee, Hae-Ryong;Gwak, Jong-Gu;Jeong, U-Chang;Jo, Yeong-Rae
    • Korean Journal of Materials Research
    • /
    • v.12 no.6
    • /
    • pp.447-451
    • /
    • 2002
  • Pulsed DC-plasma nitriding has been applied to form nitride layer having only a diffusion layer. The discharge current with the variation of discharge gases is proportional to the intensity of $N_2^+$ peak in optical emission spectroscopy during the plasma nitriding. The discharge current, microhardness in surface of substrate and depth of nitride layer increased with the ratio of $N_2\;to\;H_2$ gas in discharge gases. When the ratio of $N_2\;to\;H_2$ is lower than 60% in the discharge gases, high microhardness value of 1100Hv nitride layer which contains no compound layer has been formed.

Formation of Nanoparticles by Spark Discharge in Liquid (용액 내 스파크 방전을 이용한 나노입자 제조 및 특성 평가)

  • Choi, Hoomi;Kim, Jangah;Jung, Seungkyo;Yoon, Juho;Kim, Taesung
    • Particle and aerosol research
    • /
    • v.8 no.1
    • /
    • pp.37-43
    • /
    • 2012
  • In this study, we designed a 'spark in liquid' system. The spark discharge between two electrodes were used to generate particles by using sufficient temperature to evaporate a part of electrodes. The power supply system provides a continuous spark discharge by discharging of the capacitor to ionize the electrodes in liquid. The DC spark discharge system operates with 1-10 kV voltage. Processed copper and graphite rods were used to both electrodes with 1-3 mm diameter. There are several variables which can control the particle size and concentration such as gap distance between electrodes, applied voltage, operating liquid temperature, electrode type and liquid type. So we controlled these variables to confirm the change of particle size distribution and concentration of particles contained in liquid as wt%. 'spark in liquid' system is expected to apply nanoink by control of concentration with analysis of characteristics.

Multi-Functional Finish of Polyester and P/C blend Fabrics by Corona Discharge(I) -Flame-Retardant and Sanitary Finish- (코로나 방전처리에 의한 폴리에스테르 및 P/C 혼방직물의 복합기능화 가공(I) -난연 및 위생가공-)

  • Lee, Bang One;Pak, Pyong Ki;Lee, Hyun Ja;Lee, Hwa Sun
    • Textile Coloration and Finishing
    • /
    • v.9 no.2
    • /
    • pp.1-9
    • /
    • 1997
  • This paper was carried out to introduce flame retardant and antibiotic properties to polyester(PET) and polyester/cotton(P/C) blend fabrics. PET and P/C blend fabrics were treated by a paddry-cure method in the aqueous solutions of the finishing agents(JA 6034, JA 6050, DC-5700). The corona discharge technique was applied to increase the polar group of the polymer surface. The characteristics of the treated fabric were investigated by means of scanning electron microscope (SEM) and electron spectroscopy for chemical analysis(ESCA), and water penetration time, limiting Oxygen index(LOI), and K/S value were also measured. Wettability of the fabrics was increased considerably with the corona discharge treatment. ESCA was used to elucidate the surface chemical composition of the fabrics treated with the corona discharge. Relative Ols intensity increased and oxygen was incorporated in the form of -C-O-, -C=O, and O=C-O on the polymer surface. The current study indicated that corona discharge treatment was effective for modifying the polymer surface.

  • PDF

Thrust Performances of a Very Low-Power Micro-Arcjet

  • Hotaka Ashiya;Tsuyoshi Noda;Hideyuki Horisawa;Kim, Itsuro ura
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.611-616
    • /
    • 2004
  • In this study, microfabrication of a micro-arcjet nozzle with Fifth-harmonic generation Nd:YAG pulses (wavelength 213 nm) and its thrust performance tests were conducted. A micro-arcjet nozzle was machined in a 1.2 mm thick quartz plate. Sizes of the nozzle were 0.44 mm in width of the nozzle exit and constrictor diameter of 0.1 mm. For an anode, a thin film of Au (~100 nm thick) was deposited by DC discharge PVD in vacuum on divergent part of the nozzle. As for a cathode, an Au film was also coated on inner wall surface. In operational tests, a stable discharge was observed for mass flow of 1.0mg/sec, discharge current of 6 ㎃, discharge voltage of 600 V, or 3.6 W input power (specific power of 3.6 MW/kg). In this case, plenum pressure of the discharge chamber was 80 ㎪. With 3.6 W input power, thrust obtained was 1.4 mN giving specific impulse of 138 sec with thrust efficiency of 24 %.

  • PDF

Glow discharge cleaning 법에 의한 stainless steel의 outgassing rate 감소

  • 임종연;이상균;서인용;최상철;홍승수;신용현;정광화
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.40-40
    • /
    • 1999
  • 가속기나 토카막과 같은 거대한 진공 장치의 용기 내벽을 청정화 하기 위해서는 용기 전체의 열처리(굽기, Baking)와 글로우 방전(Glow discharge) 법을 병행하여 사용한다. Baking은 일반 기체(N2, O2, 그리고 CO2)와 물(H2O)의 탈착에 효과적이고, Glow discharge cleaning은 탄소(Carbon-based)와 산소(Oxygen-based) 화합물의 탈착에 효과적이다. 특히 Glow discharge cleaning의 경우에는 전극의 모양, 진공 용기의 재질과 모양, 전극간의 거리, 사용되는 반응 기체의 압력 등에 따라 그 효과에 큰 차이가 있으므로 다각적인 연구가 필요하다. 본 연구에서는 그림 1과 같이 시험용 스테인레스(AISI 304와 AISI 316LN) 진공 용기를 설치하고, 시험 용기의 한쪽은 배기 용기와 oriffice로, 다른 편은 불순물의 정성.정량 분석을 위해 RGA(Residual gas analyser) 용기와 oriffice로 연결하였다. 전체 시스템 중에서 배기 부분과 분석 부분은 15$0^{\circ}C$에서 24시간 가열하여 전체의 기저 진공도를 1$\times$10-8Torr로 하였다. 기저 진공도의 용기에 고순도의 반응기체 (He, Ar, Ar+He, Ar+H2, Ar+N2 등)를 주입한후, DC 전압(0.8~1.5kV)을 변화하며 글로우 방전의 최적조건을 찾았다. 방전 동안 시험용 용기에서 방출되는 반응 기체 이외의 기체를 RGA로 측정하였고 외부에 Thermocouple을 여러곳에 장착하여 온도 변화를 측정하였다. 이상의 결과로부터 진공 용기 표면적으로부터의 불순물 탈착(desorption)과 불순물 분석, 플라즈마와 내벽의 상호작용등에 대한 결론을 얻을 수 있었다. 또한 Baking과 Glow discharge cleaning을 동시에 수행하여 Baking 온도의 낮춤에 따른 영향 평가도 수행하였다.

  • PDF

A Protection Circuit for the Power Supply of a Gas Discharge Lamp

  • Kim, Ho-Sung;Kim, Jong-Hyun;Baek, Ju-Won;Yoo, Dong-Wook;Jung, Hye-Man;Kim, Hee-Je
    • Journal of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.777-783
    • /
    • 2010
  • In order to drive gas discharge lamps, DC-AC converters with a LCC resonant tank, whose output voltage is adjusted by a variable frequency control are frequently used. However, when they are activated by varying the operating frequency, converters are frequently damaged by unstable operation, due to the rising and falling of the operating frequency near the resonant frequency. To solve this problem, a simple protection circuit for the power supply of a gas discharge lamp is proposed in this paper. This circuit senses the primary current of the main transformer. Using this protection circuit, the operating frequency of the lamp driving inverter system is kept close to and on the right side of the resonant frequency and the inverter is always operated in the ZVS condition. The resulting stable variable frequency operation allows various gas discharge lamps to be tested without the risk of damaging the main switches, because the protection circuit can protect the power MOSFETs of bridge converters from abnormal conditions. The validity and effectiveness of the proposed protection circuit are verified through the experimental results.

Comparison of UV images and Measurement of the Corona Discharge from Insulators using the UV Sensor (UV 센서를 이용한 절연애자의 코로나 방전 측정 및 자외선 이미지의 비교)

  • Kim, Young-Seok;Choi, Myeong-Il;Kim, Chong-Min;Bang, Sun-Bae;Shong, Kil-Mok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.899-904
    • /
    • 2011
  • Inspections and diagnoses of corona discharge are important in order to prevent electrical faults of external insulation in power systems. This paper studies a measurement of ultra-violet rays(UV) strength of corona discharges on insulators using a UV sensor with an optic lens. The data has been compared with the images of a UV camera. The UV sensor estimated that DC voltage needed to be set at 700V for accurate data analysis of the properties of UV detected during corona discharge. UV was generated at 60kV when the corona discharge occurred. UV strength and images of UV increased at a high voltage. The image area of the UV using a UV camera and the detection of UV using a UV sensor have shown, that the polymer insulator mounted on a live part must be checked when the applied voltage on the good polymer insulator is greater than 37.5% of its breakdown voltage.

A New Ac-to-Dc Power Converter for a Load with Frequent Short Circuits (부하단락이 빈번히 발생하는 경우에 적합한 교류-직류 전력변환기)

  • No, Ui-Cheol;Kim, In-Dong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.7
    • /
    • pp.384-390
    • /
    • 1999
  • This paper describes a new ac-to-dc power converter using a multilevel converter. A conventional multilevel ac-to-dc converter has large output dc filter capacitors. When a short circuit happens in a load, the stored energy in the capacitors should be discharged through the load with a high short circuit current. The high current may cause considerable damage to the capacitors and the load. The output dc capacitors of the proposed converter do not discharge even under load short circuit condition. In the case of a load short circuit, the capacitors become a floating state immediately and remain in the state. Then the stored capacitor energy is supplied to the load again as soon as the short circuit has been cleared. Therefore, the rising time of the load voltage can be significantly reduced. This feature satisfies the requirement of a power supply for a load with frequent short circuits. The proposed converter has the characteristics of a simplified structure, a reduced cost, weight, and volume compared with conventional power supplies with frequent output short circuits. Experimental results are presented to verify the usefulness of the proposed converter.

  • PDF