• 제목/요약/키워드: D2D Coverage

검색결과 237건 처리시간 0.028초

지반침하 피해도 분석을 위한 GIS 활용에 관한 연구 (A Study on the Application of GIS for Analysis of Subsidence Hazard)

  • 권광수;유명환;박형동
    • 자원환경지질
    • /
    • 제33권6호
    • /
    • pp.557-563
    • /
    • 2000
  • Subsidence hazard has never been considered seriously until recent yews in Korea, although its socioeconomic impact on Korea becomes more and more enormous. There have been a few studies for the application of GIS analysis technique to the prediction of subsidence hazard. For GIS analysis, several factors, which are represented by coverage, are considered and selected for building a GIS model. Numerical method was used to quantify the importance of each factor in GIS model and the result from numerical modeling using FLAC was compared with that from previous research based on empirical methods. Analysis in 3-D needs more computer resources (i.e. memory). Therefore that in 2.5-D was considered to overcome the problem. Not only maximum vertical subsidence but also maximum horizontal strain and maximum slope have been considered for the assessment of subsidence hazard. The model can be easily modified for the purpose of applications in any subsidence area, especially cavern or abandoned mines under thick soil layer.

  • PDF

3차원 토러스 구조를 갖는 멀티컴퓨터에서의 동적 작업 스케줄링 알고리즘 (Dynamic Task Scheduling for 3D Torus Multicomputer Systems)

  • 추현승;윤희용;박경린
    • 정보처리학회논문지A
    • /
    • 제8A권3호
    • /
    • pp.245-252
    • /
    • 2001
  • 멀티컴퓨터 시스템은 많은 연산 노드들을 이용함으로써 높은 성능을 얻는다. 다차원 매쉬(mash)는 단순함과 효율성 때문에 멀티컴퓨터 구조로 널리 이용되었다. 본 논문은 3차원 토러스(torus) 시스템을 위한 최초 적합(first-fit) 방법에 기반한 효율적인 프로세서 할당 알고리즘을 제안한다. 이 알고리즘은 CST(Coverage Status Table)을 이용하여 3차원 정보를 2차원 정보로 변형하므로써 프로세서 할당 시간을 최소화 한다. 종합적인 컴퓨터 시뮬레이션 결과는 제안한 방법이 최적 적합(best-fit)에 기반한 기존 방법들과 비교해서 프로세서 이용률은 비슷하면서, 프로세서 할당 시간이 항상 짧다는 것을 보여준다. 성능 차이는 입력 부하가 증가함에 따라 더욱 두드러진다. 다른 스케줄링 환경상에서 제안된 방법의 성능을 조사하기 위해서, 전형적인 FCFS 스케줄링 기법과 함께 non-FCFS 스케줄링 기법도 연구된다.

  • PDF

두경부암 세기변조방사선치료 계획 시 부분적 고에너지 광자선 사용에 따른 치료계획 평가 (The Effect of Partially Used High Energy Photon on Intensity-modulated Radiation Therapy Plan for Head and Neck Cancer)

  • 장남준;석진용;원희수;홍주완;최지훈;박진홍
    • 대한방사선치료학회지
    • /
    • 제25권1호
    • /
    • pp.1-8
    • /
    • 2013
  • 목 적: 체내에서 광자선은 에너지에 따라 다른 선량분포 특성을 보이기 때문에 치료계획 시 적절한 에너지 선택이 중요하다. 두경부암 세기변조방사선치료(intensity modulated radiation therapy, IMRT)는 주로 저에너지 광자선을 사용하는데, 본 연구에서는 후사방향 조사면에 부분적으로 고에너지 광자선을 사용하였을 때 치료계획에 미치는 영향을 알아보고자 한다. 대상 및 방법: 본원에서 두경부암 세기변조방사선치료를 시행한 10명(nasopharyngeal carcinoma 5, tonsilar carcinoma 5)의 환자를 대상으로 하였다. 동일한 조건하에 환자의 CT영상을 3 mm 두께로 획득하고 치료계획시스템은 Eclipse (Ver 7.1, Varian, Palo Alto, USA)를 사용하였다. 환자마다 8개 조사면으로 6 MV 에너지를 사용한 치료계획(low energy plan, LEP)과 상대적으로 투과 깊이가 깊은 후사방향의 2개 조사면에서 15 MV 에너지를 사용한 치료계획(partially used high energy plan, PHEP)을 각각 수립하였으며, 다른 치료계획조건들과 plan normalization은 동일하게 적용하였다. 수립된 치료계획을 평가하기 위해서 계획표적체적(planning target volume, PTV)의 coverage, conformity index (CI), homogeneity index (HI)를 비교하였고 양측 이하선의 $D_{mean}$, $D_{50%}$와 뇌척수의 $D_{max}$, $D_{1%}$ 그리고 integral dose (ID)를 비교하였다. 특히, 후경부의 정상조직선량을 비교하기 위해 posterior-normal tissue volume (P-NTV)을 설정하고 dose volume histogram (DVH)을 통해서 $D_{mean}$, $V_{20Gy}$, $V_{25Gy}$를 평가하였으며, 또한 총 monitor unit (MU)의 변화를 비교하였다. 결 과: LEP와 PHEP 사이에서 PTV의 coverage 그리고 CI의 차이는 크지 않았고, HI는 변화없이 전체적으로 동일하게 나타났다. 뇌척수의 선량변화는 크지 않았지만 양측 이하선의 $D_{mean}$, $D_{50%}$ 그리고 ID는 PHEP에서 각각 0.6%, 0.7%, 1.1% 감소하였다. P-NTV의 $D_{mean}$, $V_{20Gy}$, $V_{25Gy}$는 PHEP에서 각각 1.6%, 1.8%, 2.9% 감소하였고, 총 MU도 평균 1.8% 감소하였다. 결 론: 본 연구결과 후사방향에서 부분적으로 고에너지를 사용한 치료계획에서 일부 결정장기(organ at risk, OAR)와 정상조직의 선량, 그리고 총 MU를 감소시키는 효과가 있었다. 이런 효과가 환자에게 임상적으로 얼마나 이로운지는 명확하지 않지만, 두경부암 세기변조방사선치료 계획 시 부분적으로 고에너지 광자선을 사용하는 것은 치료계획의 전반적인 질을 개선하는 데 유용 할 것으로 본다.

  • PDF

소형셀 네트워크 성능 분석을 위한 새로운 평가 방법 (A Novel Performance Evaluation Methodology for Small Cell Networks)

  • 임연근;채찬병
    • 한국통신학회논문지
    • /
    • 제38A권12호
    • /
    • pp.1110-1116
    • /
    • 2013
  • 3D-ray tracing tool은 신호의 반사, 투과, 그리고 회절까지 고려하여 3차원 공간에서 더욱 정확한 네트워크 성능을 분석하기 위한 소프트웨어이다. 통신표준에서는 통신 자원을 효율적으로 제공하기 위해 소형셀을 포함한 Heterogeneous Networks (HetNets)을 도입하고 있다. 매크로셀에 비해 좁아진 커버리지를 사용하는 소형셀 환경에서는 3D 공간에서 성능분석이 중요해 졌다. 또한 지형구조와 건물의 배치 그리고 3D 빔포밍(beamforming) 기술 등의 사용으로 인해 네트워크 환경이 복잡해지기 때문에 기존의 2차원 수학적 모델들을 이용하여 성능을 분석하기에는 어려움이 따른다. 본 논문에서는 소형셀 네트워크 성능을 더욱 효율적으로 분석하기 위한 3D-ray tracing tool을 활용한 성능평가 방법을 소개한다. 성능평가 결과 기존의 방법보다 3D-ray tracing tool을 활용한 성능평가 방법이 소형셀 환경에서 더욱 적합하다는 결론을 내렸다.

2차원 및 3차원 수중 센서 네트워크에서 에너지 효율적인 데이터전송 알고리즘 (Energy Efficient Data Transmission Algorithms in 2D and 3D Underwater Wireless Sensor Networks)

  • 김성운;박선영;천현수;김근호
    • 한국멀티미디어학회논문지
    • /
    • 제13권11호
    • /
    • pp.1657-1666
    • /
    • 2010
  • 수중 센서 네트워크(UWSN: Underwater Wireless Sensor Networks)는 수중 센서 노드들의 에너지 자원의 제약이 심하고, 제한된 통신 대역폭과 다양한 전파지연 등의 환경적인 특성 때문에 효율적이고 안정적인 데이터전송 방법이 요구된다. 본 논문에서는 수중 센서 네트워크의 센서 노드들이 해양 바닥에 고정된 2차원 구조(2D: two-dimensional underwater wireless sensor network model)에서 이상적인 셀 크기의 육각 모자이크 구조를 이용한 향상된 하이브리드 전송 방법을 설명하고, 또한 센서 노드를 해양 바닥의 닻에 매달아 움직임이 가능한 3차원 구조(3D: three-dimensional underwater wireless sensor network model)에서 효과적인 데이터전송을 위한 에너지 효율적인 인식 및 통신범위를 확장하는 방법을 제안한다. 2D 및 3D 구조에서 제안된 방법들은 시뮬레이션 결과에 의해 기존의 전송 방법보다 높은 에너지 효율성을 가지는 것이 확인되었다.

X-Band 6-Bit Phase Shifter with Low RMS Phase and Amplitude Errors in 0.13-㎛ CMOS Technology

  • Han, Jang-Hoon;Kim, Jeong-Geun;Baek, Donghyun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권4호
    • /
    • pp.511-519
    • /
    • 2016
  • This paper proposes a CMOS 6-bit phase shifter with low RMS phase and amplitude errors for an X-band phased array antenna. The phase shifter combines a switched-path topology for coarse phase states and a switch-filter topology for fine phase states. The coarse phase shifter is composed of phase shifting elements, single-pole double-throw (SPDT), and double-pole double-throw (DPDT) switches. The fine phase shifter uses a switched LC filter. The phase coverage is $354.35^{\circ}$ with an LSB of $5.625^{\circ}$. The RMS phase error is < $6^{\circ}$ and the RMS amplitude error is < 0.45 dB at 8-12 GHz. The measured insertion loss is < 15 dB, and the return losses for input and output are > 13 dB at 8-12 GHz. The input P1dB of the phase shifter achieves > 11 dBm at 8-12 GHz. The current consumption is zero with a 1.2-V supply voltage. The chip size is $1.46{\times}0.83mm^2$, including pads.

Application of 3D magnetotelluric investigation for geothermal exploration - Examples in Japan and Korea

  • Uchida Toshihiro;Song Yoonho;Mitsuhata Yuji;Lee Seong Kon
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.390-397
    • /
    • 2003
  • A three-dimensional (3D) inversion technique has been developed for interpretation of magnetotelluric (MT) data. The inversion method is based on the linearized least-squares (Gauss-Newton) method with smoothness regularization. In addition to the underground 3D resistivity distribution, static shifts are also treated as unknown parameters in the inversion. The forward modeling is by the staggered-grid finite difference method. A Bayesian criterion ABle is applied to search the optimum trade-off among the minimization of the data misfit, model roughness and static shifts. The method has been applied to several MT datasets obtained at geothermal fields in Japan and other Asian countries. In this paper, two examples will be discussed: one is the data at the Ogiri geothermal area, southwestern Japan, and the other is at the Pohang low-enthalpy geothermal field, southeastern Korea. The inversion of the Ogiri data has been performed stably, resulting in a good fitting between the observed and computed apparent resistivities and phases. The recovered 3D resistivity structure is generally similar to the two-dimensional (2D) inversion models, although the deeper portion of the 3D model seems to be more realistic than that of the 2D model. The 3D model is also in a good agreement with the geological model of the geothermal reservoirs. 3D interpretation of the Pohang MT data is still preliminary. Although the fitting to the observed data is very good, the preliminary 3D model is not reliable enough because the station coverage is not sufficient for a 3D inversion.

  • PDF

순차적 시뮬레이션을 위한 순차적인 Percentile 추정에 관한 연구 (Sequential Percentile Estimation for Sequential Steady-State Simulation)

  • 이종숙;정해덕
    • 정보처리학회논문지D
    • /
    • 제10D권6호
    • /
    • pp.1025-1032
    • /
    • 2003
  • 백분위수는 시뮬레이션 결과의 전체적인 성향을 파악하는데 아주 유용한 측정 기법 중의 하나이다. 그러나, 시뮬레이션으로 수집된 데이터들에 대한 평균이나 표준편차와는 달리 백분위수를 추정하기 위해서는 모든 관측된 데이터들을 저장해야 만 한다, 왜냐하면 백분위수의 추정을 위해서는 관측된 모든 데이를 분류하여 오른차순으로 정렬하는 등 여러 단계의 처리과정이 필요하기 때문이다. 따라서, 백분위수 추정을 위해서는 관측된 모든 데이터를 저장하기 위한 대용량의 저장장치와 정렬을 위한 계산시간 (O($nlog_{2}n$))이 요구된다. 이러한 문제점을 해결하기 위한 여러 백분위수 추정 기법들이 제안되었으나 고정된 샘플 크기의 시뮬레이선(fixed sample size simulation) 을 수행할 경우에만 적용 가능하다. [11, 12, 21]. 본 논문에서는 3가지 백분위수 추정 기법(linear PE, batching PE, spectral $P^2$ PE) 을 순차적인 안정상태 시뮬레이션(sequential steady-state simulation) 에 적용하여 연구하였다. 또한, 3가지의 백분위수 추정 기법들에 대해 coverage 분석을 수행한 결과를 제시하였다.

직장풍선을 삽입한 전립선암 환자의 수술 후 방사선 치료 시 용적변조와 세기변조방사선치료계획 비교 평가 (Comparison and evaluation of volumetric modulated arc therapy and intensity modulated radiation therapy plans for postoperative radiation therapy of prostate cancer patient using a rectal balloon)

  • 정해윤;석진용;홍주완;장남준;최병돈;박진홍
    • 대한방사선치료학회지
    • /
    • 제27권1호
    • /
    • pp.45-52
    • /
    • 2015
  • 목 적 : 전립선암의 방사선치료는 치료기법에 따라 주요장기와 정상조직의 선량분포에 차이가 나타난다. 본 연구에서는 전립선암 환자의 수술 후 방사선치료 시 직장풍선을 삽입한 환자에게 회전수를 달리한 용적변조회전치료(volumetric modulated arc therapy, VMAT)계획과 세기변조방사선치료(intensity modulated radiation therapy, IMRT)계획을 각각 수립하여 선량분포 특성을 비교하고 치료의 효율성을 평가하고자 한다. 대상 및 방법 : 본원에서 전립선암 수술 후 방사선 치료를 시행한 10명의 환자를 대상으로 하였다. 직장풍선을 삽입한 환자의 CT영상을 3 mm 두께로 획득하고 Eclipse (Ver 11.0, Varian, Palo Alto, USA)를 사용하여 HD120MLC가 장착된 Truebeam STx (Varian, Palo Alto, USA)의 10 MV 에너지를 적용하였다. 환자마다 1 Arc, 2 Arc VMAT계획과 7조사면의 IMRT계획을 수립하였으며 각 치료계획의 선량체적제한과 plan normalization 값은 동일하게 적용하였다. 수립된 세 가지 치료계획을 평가하기위해 PTV의 coverage, conformity index (CI), homogeneity index (HI)를 비교하였고, PTV주변 정상조직의 선량퍼짐정도를 알아보기 위해 50% 등선량체적과 PTV체적의 비($R_{50%}$)를 산출하였다. 결정장기 (organ at risk, OAR)에서는 직장의 $D_{25%}$와 방광의 $D_{mean}$을 비교하였고 치료의 효율성을 평가하기 위해서 총 MU와 조사시간을 측정하였으며, 각 평가항목별 결과는 환자 10명의 평균값으로 비교분석하였다. 추가적으로 선량전달 정확도를 검증하기 위해 EPID를 이용한 portal dosimetry를 진행하였다. 결 과 : 각 치료계획에서 나타난 PTV coverage와 HI의 차이는 크지 않았지만 CI는 1A-VMAT, 2A-VMAT, 7F-IMRT에서 각각 1.036, 1.035, 1.230으로 VMAT에 비해 7F-IMRT가 높았고(p=0.00), $R_{50%}$는 3.083, 3.054, 3.991로 2A-VMAT이 제일 낮았고 7F-IMRT에서 가장 높게 나타났다(p=0.00). 치료계획에 따른 직장의 $D_{25%}$는 VMAT에서 비슷했지만 7F-IMRT가 약 7% 높게 나타났고(p=0.02), 방광의 $D_{mean}$은 큰 차이가 없었다(P>0.05). 총 MU는 1A-VMAT, 2A-VMAT, 7F-IMRT에서 각각 494.7, 479.7, 757.9로 7F-IMRT가 가장 많았고(p=0.00), 조사시간은 65.2초, 133.1초, 145.5초로 1A-VMAT이 확연히 짧았다(p=0.00). portal dosimetry 검증에서는 모든 치료계획에서 99.5% 이상의 gamma pass rate(2 mm, 2%)을 보였다(P=0.00). 결 론 : 본 연구결과 직장풍선을 삽입한 전립선암 환자의 수술 후 방사선치료 시, 치료기법에 따른 PTV coverage의 차이는 크지 않았지만 1A, 2A-VMAT이 7F-IMRT에 비해 정상조직과 직장선량을 낮추는데 효과적이었다. VMAT중에서는 $R_{50%}$와 MU가 2A-VMAT에서 다소 낮았지만 조사시간이 짧은 1A-VMAT이 치료에 더 효율적이며 환자의 치료 중 움직임 또한 줄일 수 있을 것으로 사료된다.

  • PDF

Radiation therapy for gastric mucosa-associated lymphoid tissue lymphoma: dose-volumetric analysis and its clinical implications

  • Lim, Hyeon Woo;Kim, Tae Hyun;Choi, Il Ju;Kim, Chan Gyoo;Lee, Jong Yeul;Cho, Soo Jeong;Eom, Hyeon Seok;Moon, Sung Ho;Kim, Dae Yong
    • Radiation Oncology Journal
    • /
    • 제34권3호
    • /
    • pp.193-201
    • /
    • 2016
  • Purpose: To assess the clinical outcomes of radiotherapy (RT) using two-dimensional (2D) and three-dimensional conformal RT (3D-CRT) for patients with gastric mucosa-associated lymphoid tissue (MALT) lymphoma to evaluate the effectiveness of involved field RT with moderate-dose and to evaluate the benefit of 3D-CRT comparing with 2D-RT. Materials and Methods: Between July 2003 and March 2015, 33 patients with stage IE and IIE gastric MALT lymphoma received RT were analyzed. Of 33 patients, 17 patients (51.5%) were Helicobacter pylori (HP) negative and 16 patients (48.5%) were HP positive but refractory to HP eradication (HPE). The 2D-RT (n = 14) and 3D-CRT (n = 19) were performed and total dose was 30.6 Gy/17 fractions. Of 11 patients who RT planning data were available, dose-volumetric parameters between 2D-RT and 3D-CRT plans was compared. Results: All patients reached complete remission (CR) eventually and median time to CR was 3 months (range, 1 to 15 months). No local relapse occurred and one patient died with second primary malignancy. Tumor response, survival, and toxicity were not significantly different between 2D-RT and 3D-CRT (p > 0.05, each). In analysis for dose-volumetric parameters, $D_{max}$ and CI for PTV were significantly lower in 3D-CRT plans than 2D-RT plans (p < 0.05, each) and $D_{mean}$ and V15 for right kidney and $D_{mean}$ for left kidney were significantly lower in 3D-CRT than 2D-RT (p < 0.05, each). Conclusion: Our data suggested that involved field RT with moderate-dose for gastric MALT lymphoma could be promising and 3D-CRT could be considered to improve the target coverage and reduce radiation dose to the both kidneys.