• Title/Summary/Keyword: D2D Coverage

Search Result 237, Processing Time 0.032 seconds

Space-Frequency Block Coded Relay Transmission System for a Shadow Area (음영 지역을 위한 주파수 공간 블록 부호화 중계기 전송 시스템)

  • Won, Hui-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5776-5782
    • /
    • 2014
  • Relay-assisted wireless communication systems have been studied widely to cope with shadow areas and extend the cell coverage. This paper proposes a space-frequency (SF) block coded single carrier-frequency division multiple access (SC-FDMA) transmission system in a relaying multi-path shadow area and present the performance comparison of SC-FDMA systems based on the signal-to-noise power ratio (SNR) between a relay and a destination station. The performance of relaying SC-FDMA systems can be improved by applying SF block code to the recovered signals of relays before re-transmitting them. The simulation result showed that the SNR performance of the proposed SF block coded relaying SC-FDMA system was approximately 5 dB better than the SNR performance of the single-path relaying SC-FDMA system at a symbol error rate (SER) of $10^{-2}$.

The Rejection of the GPS Interference Mirror Image by using the Three-dimensional Array Antenna (3차원 구조 배열안테나를 적용한 GPS 간섭신호 미러 이미지 제거)

  • Kim, JunO;Lee, Sang Jeong
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.4
    • /
    • pp.295-301
    • /
    • 2018
  • Recently, GPS(Global Positioning System) array antenna technology is generally used and widely adopted as a national infrastructure structure and aero-vehicles for protection the GPS signal reception. Until now, the 2-dimensional planar array is universally used for its applications in the array antenna signal processing, however relatively higher altitude air vehicles such as UAV experiences additional null zones induced by low altitude GPS interferences which is located in a symmetry zone of antenna horizontal plane and this could make the receiving antenna pattern coverage reduction. In this paper, we improved 20% of the beam pattern receiving performance and 13 dB correlation value improvement by eliminating the interference mirror images.

A Comparison between Three Dimensional Radiation Therapy and Intensity Modulated Radiation Therapy on Prostate Cancer (전립샘암의 방사선 치료 시 입체조형치료법와 세기조절방사선 치료법의 비교)

  • Kim, YoungJae;Lee, JaeSub;Hong, Seongill;Ko, HyeJin
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.409-414
    • /
    • 2013
  • In this study, we evaluated to the superiority of treatment techniques on prostate cancer, apply to each other treatment techniques-3D conformal therapy versus IMRT-using dose distribution and dose coverages. Obtained 10 patients CT simulation, divided tumor volume and critical organs. Prescription dose was 80 Gy on tumor volume and Each of plans was set by two different plans. As a result, Dose coverage was superior to IMRT. The IMRT's tumor absorbed dose(100.2%) was close to prescription doses. Normal tissue(bladder, rectal, bowel Lt Rt fumoral head) absorbed dose rate was superior. In other words, the radiation therapy of prostate cancer with intensity modulated radiation therapy was better than conformal radiation therapy on dose.

Comparison of Beam Transfer Methods between Tomo Therapy and Proton Therapy for Prostate Cancer Radiation Therapy (전립선암 방사선 치료 시 토모치료와 양성자치료 빔 전달방식 비교)

  • Park, Jung Min;Ko, Eun Seo;Lee, Jin Hee;Kim, Jin Won;Yang, Jin Ho;Kwon, Kyung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.75-81
    • /
    • 2019
  • Purpose: Tomo therapy and Proton therapy treatment plans for the treatment of prostate cancer patients were established, and the characteristics of dose distribution according to beam delivery method using Tomo therapy IMRT method and Proton therapy PBS method to compare and analyze the treatment effect were sought. Materials and Methods: Tomo IMRT treatment plan and Proton PBS treatment plan were established using the Hi.art planning station 5.1.1.6 of Tomo therapy and Eclipse 13.7 of VARIAN for three prostate cancer patients who were treated with radiotherapy only for radical purposes without surgery. For the evaluation of two treatment plans, the average dose (Dmean) and maximum dose (Dmax) of PGTV were calculated from dose volume histogram (DVH) to confirm the coverage and calculate CI and HI. In OAR evaluation, the dose received from the rectal volume 25% and the dose received from the bladder were evaluated to compare the normal long-term protection effect. Results: The mean maximum doses of the three patients were 71.4Gy, 75.3Gy and the mean doses were 70.4Gy and 72.8Gy in the DVH of the Tomo IMRT and Proton PBS. The CI was 1.16 and 1.31, and the HI was 0.04 and 0.12 respectively, and the Tomo IMRT was superior to the Proton PBS in dose suitability. Conclusion: The mean dose of PGTV in prostate cancer patients was 3.4% higher in Proton PBS than in Tomo IMRT. This is because the Dose suitability of Tomo IMRT was better, but it is considered to be a small difference to be seen as a significant result. However, the results of the two methods were 51.2% in D 25% and 55.7% less in the average dose of bladder, which could reduce the side effects of patients in proton PBS.

A Study on lung dose of Intensity modulated and volumetric modulated arc therapy plans using restricted angle of Non-small cell lung cancer (비소세포 폐암의 제한된 각도를 이용한 세기변조와 용적변조회전 방사선치료계획의 폐 선량에 관한 연구)

  • Yeom, Misuk;Lee, Woosuk;Kim, Daesup;Back, Geummun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.21-28
    • /
    • 2014
  • Purpose : For non-small cell lung cancer, if the treatment volume is large or the total lung volume is small, and the tumor is located in midline of patient's body, total lung dose tends to increase due to tolerance dose of spinal cord. The purpose of this study is to compare and evaluate the total lung dose of three dimensional conformal radiotherapy(3D CRT), intensity modulated radiotherapy(IMRT) and volumetric modulated arc therapy(VMAT) using restricted angle for non-small cell lung cancer patients. Materials and Methods : The treatment plans for four patients, being treated on TrueBeam STx($Varian^{TM}$, USA) with 10 MV and prescribed dose of 60 Gy in 30 fractions, 3D CRT, restricted angle IMRT and VAMT radiotherapy plans were established. Planning target volume(PTV), dose to total lung and spinal cord were evaluated using the dose volume histogram(DVH). Conformity index(CI), homogeneity index(HI), Paddick's index(PCI) for the PTV, $V_{30}$, $V_{20}$, $V_{10}$, $V_5$, mean dose for total lung and maximum dose for spinal cord was assessed. Results : Average value of CI, HI and PCI for PTV was $0.944{\pm}0.009$, $1.106{\pm}0.027$, $1.084{\pm}0.016$ respectively. $V_{20}$ values from 3D CRT, IMRT and VMAT plans were 30.7%, 20.2% and 21.2% for the first patient, 33.0%, 29.2% and 31.5% for second patient, 51.3%, 34.3% and 36.9% for third patient, finally 56.9%, 33.7% and 40.0% for the last patient. It was noticed that the $V_{20}$ was lowest in the IMRT plan using restricted angle. Maximum dose for spinal cord was evaluated to lower than the tolerance dose. Conclusion : For non-small cell lung cancer, IMRT with restricted angle or VMAT could minimize the lung dose and lower the dose to spinal cord below the tolerance level. Considering PTV coverage and tolerance dose to spinal cord, it was possible to obtain IMRT plan with smaller angle and this could result in lower dose to lung when compared to VMAT.

Temperature Fluctuations Over the Past 2000 Years in Western Mongolia

  • Pederson, Neil;Jacoby, Gordon C.;D′Arrigo, Rosanne.;Frank, David;Buckley, Brendan;Nachin, Baatarbileg;Chultem, Dugarjav;Renchin, Mijiddorj
    • The Korean Journal of Quaternary Research
    • /
    • v.17 no.2
    • /
    • pp.157-159
    • /
    • 2003
  • Much of northern Asia is lacking in high-resolution palaeoclimatic data coverage. This vast region thus represents a sizeable gap in data sets used to reconstruct hemispheric-scale temperature trends for the past millennium. To improve coverage, we present a regional-scale composite of four tree-ring width records of Siberian pine and Siberian larch from temperature-sensitive alpine timber-line sites in Mongolia. The chronologies load closely in principal components analysis (PCA) with the first eigenvector accounting for over 53% of the variance from ad 1450 to 1998. The 20-year interval from 1974 to 1993 is the highest such growth period in this composite record, and 17 of the 20 highest growth years have occurred since 1946. Thus these trees, unlike those recently described at some northern sites, do not appear to have lost their temperature sensitivity, and suggest that recent decades have been some of the warmest in the past 500 years for this region. There are, however, comparable periods of inferred, local warmth for individual sites, e.g., in 1520-1580 and 1760-1790. The percent common variance between chronologies has increased through time and is highest (66.1%) in the present century. Although there are obvious differences among the individual chronologies, this result suggests a coherent signal which we consider to be related to temperature. The PCA scores show trends which strongly resemble those seen in recent temperature reconstructions for the Northern Hemisphere, very few of which included representation from Eurasia east of the Ural Mountains. The Mongolia series therefore provides independent corroboration for these reconstructions and their indications of unusual wanning during the twentieth century.

  • PDF

The Film Property and Deposition Process of TSV Inside for 3D Interconnection (3D Interconnection을 위한 실리콘 관통 전극 내부의 절연막 증착 공정과 그 막의 특성에 관한 연구)

  • Seo, Sang-Woon;Kim, Gu-Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.15 no.3
    • /
    • pp.47-52
    • /
    • 2008
  • This investigation was performed in order to study the properties of deposition and layers by Silicon Dioxide, SiO2, as dielectric onto Via and Trench which have high Aspect Ratio (AR). Thus, in order to confirm these properties, three types of CVD, which were PECVD, PETEOS, and ALD, were selected. On the experiment each of the property sections was estimated that step overage of PECVD: <30%, PETEOS: 45%, ALD: 75% and the RSM of PECVD: 27.8 nm, PETEOS: 2.1 nm, ALD: <2.0 nm. As a result of this experiment for the property of electric film, ALD was valuated to be the most favorable outcome. However, ALD was valuated to have the least quality for the deposition rate. ALD deposition rate, $10\;\AA/min$ by $1\;\AA$/1cycle, was prominently lower than PETEOS, which had the deposition rate of $5000\;\AA$/min. Since electric film requires at least $1000\;\AA$ thicknesses, ALD was not suitable for the deposition rate. which is the most important component in a practical use. Therefore, in this particular study, PETEOS was evaluated to be the most suitable recipe.

  • PDF

Phased-Array Quadrature RF Coil for Magnetic Resonance Imaging (자기공명영상촬영을 위한 Phased-Array Quadrature RF 코일)

  • Kim, S.K.;Yang, Y.J.;Lee, D.R.;Ahn, C.B.;Lee, H.K.;Oh, C.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.227-229
    • /
    • 1997
  • A new phased-array quadrature RF coil for one or two RF acquisition channels is developed for spine MR imaging. Quadrature RF coils for MRI have been useful to improve the signal-to-noise ratio (SNR) by $"\sqrt{2}"$ using two orthogonal RF coils in combination [1]. More recently, the phased-array RF coil has been proposed for more improvement of SNR by using an array of RF coil elements with a reduced size and coverage for each element. Two new schemes are proposed for the new phased-array quadrature RF coil as follows : (1) Proper overlapping of two quadrature RF coils thus removing the mutual inductance and (2) Attaching preamplifiers right after the coil section and combining the signal with proper phase delays. The coil has been implemented for receive- only mode. It has been tested through phantom and volunteer imaging. The experimental results show the utility of the proposed RF coil.

  • PDF

Dosimetric Plan Comparison of Accelerated Partial Breast Irradiation (APBI) Using CyberKnife

  • Lee, Chang Yeol;Kim, Woo Chul;Kim, Hun Jeong;Lee, Jeongshim;Park, Seungwoo;Huh, Hyun Do
    • Progress in Medical Physics
    • /
    • v.29 no.2
    • /
    • pp.73-80
    • /
    • 2018
  • Accelerated partial breast irradiation (APBI) is a new treatment delivery technique that decreases overall treatment time by using higher fractional doses than conventional fractionation. Here, a quantitative analysis study of CyberKnife-based APBI was performed on 10 patients with left-sided breast cancer who had already finished conventional treatment at the Inha University Hospital. Dosimetric parameters for four kinds of treatment plans (3D-CRT, IMRT, VMAT, and CyberKnife) were analyzed and compared with constraints in the NSABP B39/RTOG 0413 protocol and a published CyberKnife-based APBI study. For the 10 patients recruited in this study, all the dosimetric parameters, including target coverage and doses to normal structures, met the NSABP B39/RTOG 0413 protocol. Compared with other treatment plans, a more conformal dose to the target and better dose sparing of critical structures were observed in CyberKnife plans. Accelerated partial breast irradiation via CyberKnife is a suitable treatment delivery technique for partial breast irradiation and offers improvements over external beam APBI techniques.

Impact of SAPHIR Data Assimilation in the KIAPS Global Numerical Weather Prediction System (KIAPS 전지구 수치예보모델 시스템에서 SAPHIR 자료동화 효과)

  • Lee, Sihye;Chun, Hyoung-Wook;Song, Hyo-Jong
    • Atmosphere
    • /
    • v.28 no.2
    • /
    • pp.141-151
    • /
    • 2018
  • The KIAPS global model and data assimilation system were extended to assimilate brightness temperature from the Sondeur $Atmosph{\acute{e}}rique$ du Profil $d^{\prime}Humidit{\acute{e}}$ Intertropicale par $Radiom{\acute{e}}trie$ (SAPHIR) passive microwave water vapor sounder on board the Megha-Tropiques satellite. Quality control procedures were developed to assess the SAPHIR data quality for assimilating clear-sky observations over the ocean, and to characterize observation biases and errors. In the global cycle, additional assimilation of SAPHIR observation shows globally significant benefits for 1.5% reduction of the humidity root-mean-square difference (RMSD) against European Centre for Medium-Range Weather Forecasts (ECMWF) Integrated Forecast System (IFS) analysis. The positive forecast impacts for the humidity and temperature in the experiment assimilating SAPHIR were predominant at later lead times between 96- and 168-hour. Even though its spatial coverage is confined to lower latitudes of $30^{\circ}S-30^{\circ}N$ and the observable variable is humidity, the assimilation of SAPHIR has a positive impact on the other variables over the mid-latitude domain. Verification showed a 3% reduction of the humidity RMSD with assimilating SAPHIR, and moreover temperature, zonal wind and surface pressure RMSDs were reduced up to 3%, 5% and 7% near the tropical and mid-latitude regions, respectively.