• Title/Summary/Keyword: D(X)

Search Result 6,323, Processing Time 0.038 seconds

Kinetics and Mechanism of the Anilinolysis of Dicyclohexyl Phosphinic Chloride in Acetonitrile

  • Hoque, Md. Ehtesham Ul;Lee, Hai-Whang
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.6
    • /
    • pp.1997-2002
    • /
    • 2011
  • The nucleophilic substitution reactions of dicyclohexyl phosphinic chloride [3; $cHex_2$P(=O)Cl] with substituted anilines ($XC_6H_4NH_2$) and deuterated anilines ($XC_6H_4ND_2$) are investigated kinetically in acetonitrile at 60.0 $^{\circ}C$. The anilinolysis rate is too slow to be rationalized by the stereoelectronic effects. The rate is contrary to expectations for the electronic influence of the two ligands and exhibits exceptionally great negative deviation from the Taft's eq. The deuterium kinetic isotope effects (DKIEs) involving deuterated anilines invariably change from primary normal ($k_H/k_D$ > 1; max $k_H/k_D$ = 1.10 with X = 4-MeO) with the strongly basic anilines (X = 4-MeO, 4-Me, 3-Me) to secondary inverse ($k_H/k_D$ < 1; min $k_H/k_D$ = 0.673 with X = 3-Cl) with the weakly basic anilines (X = H, 4-F, 4-Cl, 3-Cl). A concerted $S_N2$ mechanism is proposed on the basis of both secondary inverse and primary normal DKIEs. The obtained DKIEs imply that the fraction of a frontside attack increases as the aniline becomes more basic. A hydrogen-bonded, four-center-type transition state is suggested for a frontside attack, while the trigonal bipyramidal pentacoordinate transition state is suggested for a backside attack.

An Underwater Simulator Using X3D and a Motion Chair in a Multi-channel Display Room (다채널 디스플레이에서 X3D와 모션체어를 이용한 수중운동체 시뮬레이터)

  • Hur, Pil-Won;Yang, Jeong-Sam;Han, Soon-Hung
    • Korean Journal of Computational Design and Engineering
    • /
    • v.13 no.1
    • /
    • pp.45-57
    • /
    • 2008
  • A submarine good military weapon because of its confidentiality and intimidating power. Therefore, training warfighters how to maneuver submarine is very important. Because submarine is very expensive and has regional and temporal limitations, M&S(Modeling and Simulation) can be a good alternative. However, as the existing M&S systems of submarine generally use expensive commercial software and dedicated hardware, which cause the warfighters to take troubles to visit the secured places, and then to train themselves during limited time slots. Also, many M&S systems have only one-channel display system which reduces the sense of immersiveness. Another problem is that many heterogeneous simulators can hardly be used as an integrated system. To solve these problems, X3D, a platform-independent and open standard graphic file format, is used with the general-purpose PCs. To increase immersiveness, multi-channel display system and a motion chair are used. Finally, HLA/RTI is used to integrate individual components of the simulator. All of these are verified through experiments.

NOTE ON GOOD IDEALS IN GORENSTEIN LOCAL RINGS

  • Kim, Mee-Kyoung
    • Bulletin of the Korean Mathematical Society
    • /
    • v.39 no.3
    • /
    • pp.479-484
    • /
    • 2002
  • Let I be an ideal in a Gorenstein local ring A with the maximal ideal m and d = dim A. Then we say that I is a good ideal in A, if I contains a reduction $Q=(a_1,a_2,...,a_d)$ generated by d elements in A and $G(I)=\bigoplus_{n\geq0}I^n/I^{n+1}$ of I is a Gorenstein ring with a(G(I)) = 1-d, where a(G(I)) denotes the a-invariant of G(I). Let S = A[Q/a$_1$] and P = mS. In this paper, we show that the following conditions are equivalent. (1) $I^2$ = QI and I = Q:I. (2) $I^2S$ = $a_1$IS and IS = $a_1$S:sIS. (3) $I^2$Sp = $a_1$ISp and ISp = $a_1$Sp :sp ISp. We denote by $X_A(Q)$ the set of good ideals I in $X_A(Q)$ such that I contains Q as a reduction. As a Corollary of this result, we show that $I\inX_A(Q)\Leftrightarrow\IS_P\inX_{SP}(Qp)$.

A Very Low Phase Noise Oscillator with Double H-Shape Metamaterial Resonator (이중 H자 메타 전자파구조를 이용한 저위상잡음 발진기)

  • Lee, Chong-Min;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.2
    • /
    • pp.62-66
    • /
    • 2010
  • In this article, a oscillator at X-band with a double H-shape metamaterial resonator (DHMR) based on high-Q is proposed with metamaterial structure to improve Ihe phase noise and output power. The proposed oscillator is required low phase noise and high output power for the high performance frequency synthesizer. DHMR is designed to be high-Q at resonance frequency through strong coupling of E-field. This character makes phase noise excellent. The oscillator using DHMR is oscillated in X-band so as to apply frequency synthesizer of radar systems. The output power is 4.33 dBm and the phase noise is -108 dBc/Hz at 100 kHz offset of carrier frequency.

Slotted array in-motion antenna for receiving both RHCP and LHCP using a single layer film (좌선회, 우선회 원편파 모두 수신 가능한 차량용 도파관 슬롯 배열 안테나)

  • Son, Kwang-Seop;Park, Chan-Gu
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.2
    • /
    • pp.126-133
    • /
    • 2009
  • In this paper, The planar waveguide slotted antenna is presented for a satellite communication of vehicles. In stead of the microstrip patch array antenna having a dielectric loss and a feeding loss, the proposed antenna has the 3-layered waveguide feeding network structure for assembling easily. Also this antenna can receive mechanically both RHCP and LHCP transmitted from a satellite using a polarizer made from a thin single layer film. The Gain of the proposed 4X8 array antenna is 27.5dB and the gain of 8X16 array antenna is 32dB.

A Novel Varactor Diodeless Push-Push VCO with Wide Tuning Range (바렉터 다이오드를 이용하지 않은 광대역 Push-Push 전압제어 발진기)

  • Lee Moon-Que;Moon Seong-Mo;Min Sangbo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.4 s.95
    • /
    • pp.345-350
    • /
    • 2005
  • An X-band push-push VCO for low cost applications is proposed. The designed push-push oscillator achieves a wide tuning range in the X-band by the collector bias tuning instead of extra varactor diodes. The measurement shows a wide tuning bandwidth of $900\;\cal{MHz}\;from\;10.9\;\cal{GHz}\;to\;11.8\;\cal{GHz}$ with a drain bias voltage varying from 4 to 9 V, excellent fudamental suppression of $-30\;\cal{dBc}$ and good phase noise of $-115\;\cal{dBc/Hz}\;@\;1\;\cal{MHz}$ offset.

Design of Voltage Controlled Oscillator for X-band Radar Using CSRR loaded microstrip line (마이크로스트립 종단형 CSRR구조를 이용한 X-band 레이다용 전압제어발진기의 설계)

  • Kim, Gue-Chol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.9
    • /
    • pp.1277-1283
    • /
    • 2013
  • In this paper, a novel voltage controlled oscillator(VCO) using CSRR loaded microstrip line for X-band RADAR is proposed. Using the microstrip line loaded CSRR inserted between the oscillator and buffer to the filter, the harmonic suppression has been improved. The measured results of the fabricated oscillator shows that its oscillation frequencies are from 9.28 to 9.39GHz according to the tuning voltage 0~10V, its output power level are about 16.6dBm at 9.35GHz. Compared with VCO using the conventional VCO, VCO using CSRR loaded microstirp, the harmonic suppression characteristic has been improved in 10.4dB

Development and Performance Evaluation of an Ultra-Compact CT with Auto Calibration of Detector Center Axis (검출기 중심축을 자동 보정하는 초소형 CT 개발 및 성능평가)

  • Byeong-Woo Kwak;Keun-Ho Rew
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.651-662
    • /
    • 2023
  • In this study, we designed and fabricated an ultra-compact CT that automatically calibrates the detector's center axis and verified its performance. The three-dimensional reconstruction performance was evaluated using 3D CAD data and X-ray data acquired by manually calibrating the center axis of the CT detector. The results showed that tilting the center axis by more than 0.25° causes circle break phenomenon, which rapidly degrades the quality of the 3D reconstructed image. By applying the automatic calibration device of a detector center axis, the 3D reconstruction performance was enhanced by calibrating the detector center axis to match the specimen rotation axis.

Evaluation of Perfusion and Image Quality Changes by Reconstruction Methods in 13N-Ammonia Myocardial Perfusion PET/CT (13N-암모니아 심근관류 PET/CT 검사 시 영상 재구성 방법에 따른 관류량 변화와 영상 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.69-75
    • /
    • 2014
  • Purpose: The aim of this study was to evaluate changes of quantitative and semi-quantitative myocardial perfusion indices and image quality by image reconstruction methods in $^{13}N$-ammonia ($^{13}N-NH_3$) myocardial perfusion PET/CT. Materials and Methods: Data of 14 (8 men, 6 women) patients underwent rest and adenosine stress $^{13}N-NH_3$ PET/CT (Biograph TruePoint 40 with TrueV, Siemens) were collected. Listmode scans were acquired for 10 minutes by injecting 370MBq of $^{13}N-NH_3$. Dynamic and static reconstruction was performed by use of FBP, iterative2D (2D), iterative3D (3D) and iterative TrueX (TrueX) algorithm. Coronary flow reserve (CFR) of dynamic reconstruction data, extent(%) and total perfusion deficit (TPD) (%) measured in sum of 4-10 minutes scan were evaluated by comparing with 2D method which was recommended by vendor. The image quality of each reconstructed data was compared and evaluated by five nuclear medicine physicians through a blind test. Results: CFR were lower in TrueX 18.68% (P=0.0002), FBP 4.35% (P=0.1243) and higher in 3D 7.91% (P<0.0001). As semi-quantitative values, extent and TPD of stress were higher in 3D 3.07%p (P=0.001), 2.36%p (P=0.0002), FBP 1.93%p (P=0.4275), 1.57%p (P=0.4595), TrueX 5.43%p (P=0.0003), 3.93%p (P<0.0001). Extent and TPD of rest were lower in FBP 0.86%p (P=0.1953), 0.57%p (P=0.2053) and higher in 3D 3.21%p (P=0.0006), 2.57%p (P=0.0001) and TrueX 5.36%p (P<0.0001), 4.36%p (P<0.0001). Based on the results of the blind test for image resolution and noise from the snapshot, 3D obtained the highest score, followed by 2D, TrueX and FBP. Conclusion: We found that quantitative and semi-quantitative myocardial perfusion values could be under- or over-estimated according to the reconstruction algorithm in $^{13}N-NH_3$ PET/CT. Therefore, proper dynamic and static reconstruction method should be established to provide accurate myocardial perfusion value.

  • PDF

A Study on Main Engine X-mode Vibration Phenomenon due to 2nd Node Torsional Vibration of the Marine Propulsion System (선박 추진축계의 2절 비틀림진동에 기인한 주기관 X-모드 진동 현상의 연구)

  • Lee, Donchool;Kim, Junseong;Kim, Jinhee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.9
    • /
    • pp.806-813
    • /
    • 2013
  • For the past years, higher power rating 2 stroke super long stroke diesel engines having more than 8 cylinders and larger cylinder bore are installed mainly on very large containerships to save on fuel consumption. However, these engines are prone to X-mode vibration due to 2nd node torsional vibration or the X-type moment, particularly because of the increase in total length and height. Recently, cases of excessive X-mode vibration often occurred on engine's major components. This vibration is manifested also as secondary vibration causing failure in engine-mount large structures. This study investigated the excitations caused by the 2nd node propulsion shafting torsional vibration that influence X-mode vibration of the main engine and practical countermeasures are proposed. An 8RT-flex82T 8 cylinder engine and 11S90ME-C 11 cylinder engine for a container ship was used as research model.