• Title/Summary/Keyword: Cylindrical chamber

Search Result 159, Processing Time 0.026 seconds

The Characteristics of Field & Mode Distributions in a Cylindrical Reverberation Chamber (원통형 구조 전자파 잔향실 내 모드 및 필드 분포 특성)

  • 김정훈;이중근
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.5
    • /
    • pp.431-436
    • /
    • 2003
  • In this paper, simulation results of an electromagnetic field and mode distributions in a cylindrical reverberation chamber were presented. Reverberation chamber is an alternative test facility for a semi anechoic chamber, which is widely used for the analysis and measurement of electromagnetic interference and immunity tests. The method of computing the number of modes in a cylindrical reverberation chamber was presented and the number of modes in a cylindrical reverberation chamber with the same volume was compared with the different ratio of radius to height. The FDTD method was used to produce field characteristics inside of rectangular, right-angled isosceles triangular, and cylinder type reverberation chambers with the same test volume.

The Characteristics of Electric Field Distributions in a Reverberation Chamber using Cylindrical Diffuser (원통형 확산기를 사용한 전자파 잔향실내의 전기장 분포특성)

  • Lee, Yong;Rhee, Joong-Geun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.8
    • /
    • pp.121-127
    • /
    • 2008
  • This paper presents an electric field distribution in a reverberation chamber using cylindrical diffuser. The characteristics of electric field distributions are compared with QRD(Quadratic Residue Diffuser) and cylindrical diffuser for $1{\sim}3$ GHz frequency band. The FDTD(Finite-Difference Time-Domain) method is used to analyze the field characteristics, and the field uniformity. At 2 GHz, the standard deviation and the tolerance of test volume in the reverberation chamber are improved by 0.11 dB, 0.43 dB for the case of cylindrical diffuser. The field strength is increased by 43.2 dBmV/m vs QRD's of 36.6 dBmV/m. Comparing with QRD's, the characteristic of polarization is also improved. These results show that reverberation chamber using cylindrical diffuser can be used alternative facility for measurement of electromagnetic interference and immunity.

The Experimental Study of the Effective Point of Measurement for Cylindrical Ion Chamber -For Medical Electron Beams- (원통형 전리함의 유효 측정점에 관한 실험적 연구 -의료용 전자선을 중심으로-)

  • 이병용;최은경;장혜숙;홍석민;이명자;전하정
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.155-160
    • /
    • 1991
  • We have studied the effective point of measurement for cylindrical ion chamber in water phantom for medical electron beams. Markus parallel plate chamber water phantom are used for the measurement of depth dose to determine the depth of the effective point of measurement for various energies(for electron 6MeV, 9MeV, 12MeV, 16MeV, and 20MeV; Co-60; for photon 6MV, 15MV). Cylindrical ion chambes(PTW233643 with r=2.75mm, PR-05P with r=2mm, and PM30 wiht r=15mm are used for the measurement of depth dose by same mtethod and the values of d$\_$50/ and R$\_$p/ obtained by three cylindrical chambers were compared with those of a flat chamber. From this we could evaluate the effective measuring points of cylindrical ion chamber. The effective point of measurement was estimated as 0.4~0.6r shifted toward surface from the center of the chamber for electron beam, 0.3~0.7r for $\^$60/Co X-ray.

  • PDF

Optimization Design of Compact Diffuser (소형 디퓨저의 최적화 설계)

  • Lee, Young Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.4
    • /
    • pp.163-167
    • /
    • 2022
  • In this paper, an optimization design method of a diffuser using Bernoulli's theorem was reviewed. The aspect ratio of the cylindrical diffuser chamber and the diameter ratio of the air inlet and outlet were used as design parameters. For the optimal design of the cylindrical diffuser chamber, the air flow inside the chamber was simulated using ANSYS while changing the aspect ratio of the chamber. In order to confirm the simulation results, the diffuser manufactured using the laser processing machine was measured. Through ANSYS simulation and measurement, it was found that the optimal design condition was when the aspect ratio (chamber height/radius) of the diffuser chamber was 1/2 and the diameter ratio of the air inlet and outlet was also 1/2.

Evaluation of turbulent SGS model for large eddy simulation of turbulent flow inside a sudden expansion cylindrical chamber (급 확대부를 갖는 실린더 챔버 내부 유동에 관한 LES 난류모델의 평가)

  • 최창용;고상철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.3
    • /
    • pp.423-433
    • /
    • 2004
  • A large eddy simulation (LES) is performed for turbulent flow in a combustion device. The combustion device is simplified as a cylindrical chamber with sudden expansion. A flame holder is attached inside a cylindrical chamber in order to promote turbulent mixing and to accommodate flame stability. The turbulent sub-grid scale models are applied and validated. Emphasis is placed on the evaluation of turbulent model for the LES of complex geometry. The simulation code is constructed by using a general coordinate system based on the physical contravariant velocity components. The calculated Reynolds number is 5000 based on the bulk velocity and the diameter of inlet pipe. The predicted turbulent statistics are evaluated by comparing with the LDV measurement data. The Smagorinsky model coefficients are estimated and the utility of dynamic SGS models are confirmed in the LES of complex geometry.

Calibration of $^{192}Ir$ HDR Brachytherapy Source in Air and in a Cylindrical Phantom

  • Djarwani S. Soejoko;I, Arief-Riva'
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.23-27
    • /
    • 2002
  • Two $^{192}$ Ir HDR brachytherapy sources were calibrated with a Farmer ionization chamber in air method and in a PMMA cylindrical phantom. The calibration air method used ionization chamber with buildup cap, and 8 variation distances for center-to-center of the source to chamber. In the optimum distance the measured activity, especially for the high activity source, deviation was 0.3% from the activity provided by manufacturer. Calibration with a PMMA cylindrical phantom was less sensitive, and suitable for quick check method with accuracy less than 10%.

  • PDF

Ultrasound Backscattering from Erythrocyte Aggregation of Human, Horse and Rat Blood under Rotational Flow in a Cylindrical Chamber

  • Nam, Kweon-Ho;Paeng, Dong-Guk;Choi, Min-Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.4E
    • /
    • pp.159-165
    • /
    • 2006
  • Human, horse and rat bloods in a cylindrical chamber where flow was controlled by a stirring magnet were used for studying red blood cell aggregation. Ultrasound backscattered powers from blood were obtained from the backscattered signals measured by a 5 MHz focused transducer in a pulse-echo setup. The experimental results showed the differences in red blood cell (RBC) aggregation tendency among the three mammalian species with an order of horse > human > rat. The ultrasound backscattered power decreased with stirring speed in human and horse blood, but no variations were observed in rat blood. Sudden flow stoppage led to the slow increase of the backscattered power for human and horse blood. There was no self-aggregation tendency in rat blood. The enveloped echo images showed the spatial and temporal variations of RBC aggregations in the cylindrical chamber. These observations from the different mammalian species may give a better understanding of the mechanism of RBC aggregation.

Use of Cylindrical Chambers as Substitutes for Parallel-Plate Chambers in Low-Energy Electron Dosimetry

  • Chun, Minsoo;An, Hyun Joon;Kang, Seong-Hee;Cho, Jin Dong;Park, Jong Min;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.29 no.1
    • /
    • pp.16-22
    • /
    • 2018
  • Current dosimetry protocols recommend the use of parallel-plate chambers in electron dosimetry because the electron fluence perturbation can be effectively minimized. However, substitutable methods to calibrate and measure the electron output and energy with the widely used cylindrical chamber should be developed in case a parallel-plate chamber is unavailable. In this study, we measured the correction factors and absolute dose-to-water of electrons with energies of 4, 6, 9, 12, 16, and 20 MeV using Farmer-type and Roos chambers by varying the dose rates according to the AAPM TG-51 protocol. The ion recombination factor and absolute dose were found to be varied across the chamber types, energy, and dose rate, and these phenomena were remarkable at a low energy (4 MeV), which was in good agreement with literature. While the ion recombination factor showed a difference across chamber types of less than 0.4%, the absolute dose differences between them were largest at 4 MeV at approximately 1.5%. We therefore found that the absolute dose with respect to the dose rate was strongly influenced by ion-collection efficiency. Although more rigorous validation with other types of chambers and protocols should be performed, the outcome of the study shows the feasibility of replacing the parallel-plate chamber with the cylindrical chamber in electron dosimetry.

Numerical Visualization of Fluid Flow and Filtration Efficiency in Centrifugal Oil Purifier

  • Jung, Ho-Yun;Choi, Yoon-Hwan;Lee, Yeon-Won;Doh, Deog-Hee
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.1
    • /
    • pp.84-91
    • /
    • 2010
  • The centrifugal oil purifier is used in ships for purifying the engine lubrication oil. The momentum needed for the rotation of the cylindrical chamber is obtained by jet injections. The dust particles in the oil are separated by the centrifugal forces moving to the inner wall of the rotating cylindrical chamber body. The dust particles are eliminated when the particles are adsorbed onto the surface of the inner wall of the chamber body. The flow characteristics and the physical behaviours of particles in this centrifugal oil purifier have been investigated numerically and the filtration efficiencies have been evaluated. For the calculations, a commercial code has been used and the SST k-${\omega}$ turbulence model has been adopted. The MRF (Multiple Reference Frame) method has been introduced to consider the rotating effect of the flows. Under various variables, such as particle size, particle density and rotating speed, the filtration efficiencies have been evaluated. It has been verified that the filtration efficiency is increased with the increments of the particle size, the particle density and the rotating speed of the cylindrical chamber.

Separation characteristics of particles in a self-rotating type centrifugal oil purifier

  • Pyo, Young-Seok;Jung, Ho-Yun;Choi, Yoon-Hwan;Doh, Deog-Hee;Lee, Yeon-Won
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.2
    • /
    • pp.147-153
    • /
    • 2014
  • The centrifugal oil purifier is used in an engine for lubrication and to remove impurities. The momentum needed for the rotation of the cylindrical chamber is obtained by jet injections. An impure particle in the oil is separated by the centrifugal forces moving to the inner wall of the rotating cylindrical chamber body. The dust particles are eliminated when the particles are absorbed onto the surface of the inner wall of the chamber body. The flow characteristics and the physical behaviors of particles in this centrifugal oil purifier were investigated numerically and the filtration efficiencies was evaluated. For calculations, a commercial code is used and the SST (Shear Stress Transport) turbulence model has been adopted. The MFR (Multi Frames of Reference) method is introduced to consider the rotating effect of the flows. Under various variables, such as particle size, particle density and rotating speed, the filtration efficiencies are evaluated. It has been verified that the filtration efficiency is increased with the increments in the particle size, the particle density and the rotating speed of the cylindrical chamber.