• Title/Summary/Keyword: Cyclotron

Search Result 420, Processing Time 0.027 seconds

A Study on the Method of Cost Estimation for the Decommissioning Plan by the Analysis of Domestic Cyclotron Dismantling Practices (국내 사이클로트론 해체 사례 분석을 통한 해체 계획 비용 산정 방법 연구)

  • Woo, Rina;Kim, Yongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.3
    • /
    • pp.97-103
    • /
    • 2014
  • Decommission of medical cyclotron give rise to a lot of low-level radioactive waste and costs. Decommissioning cost should be reasonably calculated according to the decommissioning activities and installed components of facilities. In this paper, we investigated the experience on the cyclotron relocation from SNUH(Seoul National University Hospital) to SKKU(Sungkyunkwan University) and analyzed radioactive waste management costs by applying the disposal scenarios. Also considerations for decommissioning cost estimation are reviewed. The results could be utilized as a basic data for establishment on the methodology of decommissioning cost estimation and evaluation.

Improved Performance and Suppressed Short-Channel Effects of Polycrystalline Silicon Thin Film Transistors with Electron Cyclotron Resonance $N_2$O-Plasma Gate Oxide (Electron Cyclotron Resonance $N_2$O-플라즈마 게이트 산화막을 사용한 다결정 실리콘 박막 트랜지스터의 성능 향상 및 단채널 효과 억제)

  • 이진우;이내인;한철희
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.12
    • /
    • pp.68-74
    • /
    • 1998
  • Improved performance and suppressed short-channel effects of polysilicon thin film transistors (poly-Si TFTs) with very thin electron cyclotron resonance (ECR) $N_2$O-plasma gate oxide have been investigated. Poly-Si TFTs with ECR $N_2$O-plasma oxide ($N_2$O-TFTs) show better performance as well as suppressed short-channel effects than those with conventional thermal oxide. The fabricated $N_2$O-TFTs do not show threshold voltage reduction until the gate length is reduced to 3 ${\mu}{\textrm}{m}$ for n-channel and 1 ${\mu}{\textrm}{m}$ for p-channel, respectively. The improvements are due to the smooth interface, passivation effects, and strong Si ≡ N bonds.

  • PDF

Electromagnetic Electron-Cyclotron Wave for Ring Distribution with Alternating Current (AC) Electric Field in Saturn Magnetosphere

  • Haridas, Annex Edappattu;Kanwar, Shefali;Pandey, Rama Shankar
    • Journal of Astronomy and Space Sciences
    • /
    • v.39 no.2
    • /
    • pp.35-42
    • /
    • 2022
  • During their respective missions, the spacecraft Voyager and Cassini measured several Saturn magnetosphere parameters at different radial distances. As a result of information gathered throughout the journey, Voyager 1 discovered hot and cold electron distribution components, number density, and energy in the 6-18 Rs range. Observations made by Voyager of intensity fluctuations in the 20-30 keV range show electrons are situated in the resonance spectrum's high energy tail. Plasma waves in the magnetosphere can be used to locate Saturn's inner magnetosphere's plasma clusters, which are controlled by Saturn's spin. Electromagnetic electron cyclotron (EMEC) wave ring distribution function has been investigated. Kinetic and linear approaches have been used to study electromagnetic cyclotron (EMEC) wave propagation. EMEC waves' stability can be assessed by analyzing the dispersion relation's effect on the ring distribution function. The primary goal of this study is to determine the impact of the magnetosphere parameters which is observed by Cassini. The magnetosphere of Saturn has also been observed. When the plasma parameters are increased as the distribution index, the growth/damping rate increases until the magnetic field model affects the magnetic field at equator, as can be seen in the graphs. We discuss the outputs of our model in the context of measurements made in situ by the Cassini spacecraft.

Nano Yttrium-90 and Rhenium-188 production through medium medical cyclotron and research reactor for therapeutic usages: A Simulation study

  • Abdollah Khorshidi
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1871-1877
    • /
    • 2023
  • The main goal of the coordinated project development of therapeutic radiopharmaceuticals of Y-90 and Re-188 is to exploit advancements in radionuclide production technology. Here, direct and indirect production methods with medium reactor and cyclotron are compared to evaluate derived neutron flux and production yield. First, nano-sized 186W and 89Y specimens are suspended in water in a quartz vial by FLUKA simulation. Then, the solution is irradiated for 4 days under 9E+14 n/cm2/s neutron flux of reactor. Also, a neutron activator including three layers-lead moderator, graphite reflector, and polyethylene absorbent- is simulated and tungsten target is irradiated by 60 MeV protons of cyclotron to generate induced neutrons for 188W and 90Sr production via neutron capture. As the neutron energy reduced, the flux gradually increased towards epithermal range to satisfy (n/2n,γ) reactions. The obtained specific activities at saturation were higher than the reported experimental values because the accumulated epithermal flux and nano-sized specimens influence the outcomes. The beta emitters, which are widely utilized in brachytherapy, appeal an alternative route to locally achieve a rational yield. Therefore, the proposed method via neutron activator may ascertain these broad requirements.

A Study of Targetry Activation and Dose Analysis of PET Cyclotron Using Monte Carlo Simulation (몬테카를로 모의 모사를 이용한 의료용 사이클로트론의 Targetry 방사화 및 피폭선량 분석)

  • Jang, Donggun;Kim, Dong hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.565-573
    • /
    • 2018
  • Cyclotron for medical purposes generates nuclear reaction by accelerating protons in high speed, in order to produce radiopharmaceuticals, and unnecessary neutrons are generated through such nuclear reaction. Neutrons cause activation in the parts of cyclotron which then cause exposure to radiation for people working in the field. This study, in that regard, aims to analyze exposure level by finding out the degree of activation of aluminum body, silver body, and havar foil which are the parts of Targetry where the nuclear reaction takes place. The results of the experiment showed that aluminum body and silver body had no problems re-using them as the energy and half-life of activated nuclides were small and short, making the affect on the people working in the field extremely low. However for havar foil, its activated nuclides had a high level of energy which resulted in high level of affect to the people working in the field. The activation factors of the cyclotron were analyzed, and the results showed that the Havar foil was activated the most among the targetry parts, and greatly exposed workers due to regular replacement, and needed special management as radioactive waste.

Optical and Electrical Properties of Fluorine-Doped Tin Oxide Prepared by Chemical Vapor Deposition at Low Temperature (저온 증착된 불소도핑 주석 산화 박막의 광학적·전기적 특성)

  • Park, Ji Hun;Jeon, Bup Ju
    • Korean Journal of Materials Research
    • /
    • v.23 no.9
    • /
    • pp.517-524
    • /
    • 2013
  • The electrical and optical properties of fluorine-doped tin oxide films grown on polyethylene terephthalate film with a hardness of 3 using electron cyclotron resonance plasma with linear microwave of 2.45 GHz of high ionization energy were investigated. Fluorine-doped tin oxide films with a magnetic field of 875 Gauss and the highest resistance uniformity were obtained. In particular, the magnetic field could be controlled by varying the distribution in electron cyclotron deposition positions. The films were deposited at various gas flow rates of hydrogen and carrier gas of an organometallic source. The surface morphology, electrical resistivity, transmittance, and color in the visible range of the deposited film were examined using SEM, a four-point probe instrument, and a spectrophotometer. The electromagnetic field for electron cyclotron resonance condition was uniformly formed in at a position 16 cm from the center along the Z-axis. The plasma spatial distribution of magnetic current on the roll substrate surface in the film was considerably affected by the electron cyclotron systems. The relative resistance uniformity of electrical properties was obtained in film prepared with a magnetic field in the current range of 180~200A. SEM images showing the surface morphologies of a film deposited on PET with a width of 50 cm revealed that the grains were uniformly distributed with sizes in the range of 2~7 nm. In our experimental range, the electrical resistivity of film was able to observe from $1.0{\times}10^{-2}$ to $1.0{\times}10^{-1}{\Omega}cm$ where optical transmittance at 550 nm was 87~89 %. These properties were depended on the flow rate of the gas, hydrogen and carrier gas of the organometallic source, respectively.

The Development of Automatic Chemical Processing System for $^{67}Ga$ Production ($^{67}Ga$ 생산용 화학처리 자동화 장치 개발)

  • Lee, Dong-Hoon;Kim, Yoon-Jong;Suh, Yong-Sup;Yang, Seung-Dae;Chun, Kwon-Soo;Hur, Min-Goo;Yun, Yong-Ki;Hong, Seung-Hong
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.1
    • /
    • pp.25-33
    • /
    • 2003
  • The automatic system for $^{67}Ga$ production using for the diagnosis of malignant tumor has been developed. A solvent extraction and an ion exchange chromatography were used for the separation $^{67}Ga$ from the irradiated enriched $^{68}Zn$. This system consisted of a solvent separation unit which was composed of micro conductivity cells, air supply tubes, solvent transfer tubes, solenoid valves and glasses, a PLC based controller and a PMU user interface unit for automation. The radiation exposure to the workers and the production time can both be reduced by employing this system during the $^{67}Ga$ production phase. After all, the mass production of $^{67}Ga$ with high efficiency was possible.

Performance of the RI Exhaust Filter at Chosun University Cyclotron Facility and 18F Emission Reduction (조선대학교 사이클로트론 시설의 RI 배기필터 성능평가 및 18F 배출저감 연구)

  • Jeong, Cheol-Ki;Jang, Han;Lee, Goung-Jin
    • Journal of Radiation Industry
    • /
    • v.11 no.1
    • /
    • pp.13-18
    • /
    • 2017
  • Recently, the number of PET cyclotrons has increased in Korea. A cyclotron mainly produces $^{18}F$, which is used for the production of [$^{18}F$]FDG, a cancer diagnostic radiopharmaceutical. For radiation protection, the discharge control standard under the Nuclear Safety Act limits the radioactive concentration of $^{18}F$ in the exhaust discharged from a nuclear power utilization facility to below $2,000Bq\;m^{-3}$. However, the radioactive concentration of $^{18}F$ discharged during [$^{18}F$]FDG production at the cyclotron facility at Chosun University is maintained at about $1,500Bq\;m^{-3}$ on average, which is 75% of the concentration limit of the discharge control standard, and temporarily exceeds the standard as per the real-time monitoring results. This study evaluated the performance of the exhaust filter unit of the cyclotron facility at Chosun University by assessing the concentration of $^{18}F$ in the exhaust, and an experiment was conducted on the discharge reduction, where $^{18}F$ is discharged without reacting with the FDG precursors during [$^{18}F$]FDG synthesis and is immediately captured by the [$^{18}F$]FDG automatic synthesis unit. Based on the performance evaluation results of the exhaust filter at the cyclotron facility of Chosun University, the measured capture efficiency before and after the filter was found to be 92%. Furthermore, the results of the discharge reduction experiment, where the exhaust $^{18}F$ was immediately captured by the [$^{18}F$]FDG synthesizer, showed a very satisfactory 94.3% reduction in the concentration of discharge compared to the existing discharge concentration.

Activation Evaluation of Radiation Shield Wall (Concrete) in Cyclotron room using the Portable Nclide Analyzer Running Title: Activation Evaluation of Concrete in Cyclotron room (휴대용 핵종분석기를 활용한 사이클로트론실 내 차폐벽 방사화 평가)

  • Kim, Seongcheol;Gwon, Da Yeong;Jeon, Yeoryeong;Han, Jiyoung;Kim, Yongmin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.41-47
    • /
    • 2021
  • Purpose There are many cyclotrons compared to the land area of the Republic of Korea. Because GMP certification is required and the nuclear medicine test does not apply for insurance, the number of examinations for nuclear medicine is decreasing. Therefore, there is a high probability of early decommissioning of the cyclotron. However, we do not unusually perform the radioactivation evaluation on concrete that can be classified as radioactive waste during the decommissioning of the cyclotron. In this study, we aim to confirm the radioactivation in the concrete surface using Handheld Radionuclide Identification Devices (RIDs). Materials and Methods Because there is no cyclotron being decommissioning in the Republic of Korea, it was impossible to perform the coring of concrete for radioactivation analysis. In this study, we used the KIRAMS-13 and analyzed the concrete surface in the target direction in the cyclotron room. After setting the target direction as the center, radionuclides were measured for about five months at thirty points with vertical and horizontal intervals of 30 cm. We used the RIIDEye(Detector: NaI(Tl) detector, manufacturer: Thermo) in this study and set the measurement time per point to one day (24 hours). Results Co-60 and Cs-137 were detected in some measurement points, and we confirmed the radioactivity of Co-60 detected at the most points. As a result, we found that the radioactivity of Co-60 was high in the diagonal direction (from the lower-left direction to the upper right direction) based on the center of the target. However, we think it is impossible to apply the corresponding results to all cyclotrons because we performed the study using only one cyclotron. Conclusion In thirty measurement points, we could confirm the radioactive nuclides and the relative radioactivity using the results of portable nuclides analyzer. Therefore, we expect that we can use the portable nuclides analyzer to select the coring position of concrete during the decommissioning of the cyclotron. Also, if we secure the radioactivation data for several years, we expect to make a more accurate estimate of radioactive waste during the preparation period of decommissioning of the cyclotron.

Study on the Etching Characteristics of Fine Ta patterns by Actinometry Method (Actinometry를 이용한 Ta 미세 패턴 식각 특성에 관한 연구)

  • 김상훈;안진호
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.7 no.4
    • /
    • pp.43-47
    • /
    • 2000
  • The etching characteristic of a tantalum thin film with pure chlorine plasma was studied using an electron cyclotron resonance etcher system. Optical emission actinometry (OEA) was used for the study of the etching mechanism of a tantalum thin film and optimum process condition was achieved by OEA study. Based on this mechanism, double step etching was performed and 0.15 $\mu\textrm{m}$ L & S was acquired successfully suppressing the microloading effect.

  • PDF