• 제목/요약/키워드: Cyclone Dust Collector

검색결과 31건 처리시간 0.023초

멀티사이클론을 이용한 진공청소기의 최적설계에 관한 연구 (Optimal Design of Vacuum Cleaner with a Multi Cyclone)

  • 하건호;김응달;양병선;안영철
    • 설비공학논문집
    • /
    • 제23권2호
    • /
    • pp.126-131
    • /
    • 2011
  • Cyclone, a type of particle collector widely used in the field of ambient sampling and industrial particulate control, is the principal type of gas-solids separator that uses a centrifugal force. The goal of this study is to design and evaluate the cyclone that can be used for the household vacuum cleaners. A multi cyclone with a 1st cyclone and several 2nd cyclones is designed to improve dust collection efficiency. The dust collection efficiency and the suction power of 1st cyclone are evaluated. And the dust collection efficiency and the suction power of multi cyclone are evaluated according to various sizes of inlet and vortex finder. As a result, a cone shape porous filter has better dust collection efficiency than a cylinder shape porous filter. The dust collection efficiency of a multi cyclone is 3.5% greater than that of a single cyclone.

알루미늄 주조과정에서 배출되는 입자상물질의 물리·화학적 특성 (Physicochemical Characteristics of Particulate Matter Emitted from Aluminum Casting Process)

  • 서정민;박정호
    • 한국환경과학회지
    • /
    • 제33권5호
    • /
    • pp.297-304
    • /
    • 2024
  • PM (Particulate Matters) was collected from a bag filter dust collector at an aluminum foundries, and its physicochemical properties were investigated using particle size analyzer and scanning electron microscopy with energy dispersive X-ray spectrometer (SEM/EDS). The median volume diameter of the particles passing through the pretreatment dust collector of the cyclone was approximately 10 ㎛. The cyclone pretreatment dust collector was shown to significantly reduce the throughput of large particles with a particle size of 100 ㎛ or more. The chemical composition of the particles showed a high Al content, and trace amounts of Mg, Si, and Zn were detected.

사이클론-백 하이브리드형 집진장치에서 유동연결부 설계조건에 따른 유동균일성 전산해석 (CFD Analysis on the Flow in the Connection Duct of the Cyclone-Bag Hybrid Dust Collector)

  • 구성모;오원철;장혁상
    • 한국입자에어로졸학회지
    • /
    • 제12권4호
    • /
    • pp.115-126
    • /
    • 2016
  • Numerical analysis was done to evaluate the movement of the particles and the fluid inside of the cyclone-bag hybrid dust collector. Flow discharged from the cyclone in the hybrid particle collector has swirl pattern, and it results in the biased flow to the bag filters and deteriorates the collection performance of the bag filter. The current study is to evaluate the effect of the duct lengths and the baffle arrays in the connection duct by the computational methods. Main concerns of the analysis are how to improve the uniformity of the internal flow between the cyclone and the bag filter. Numerical analysis was done to check the particle removal efficiencies of the system with respect to the flow characteristics which is expressed in RMS values of the upward flow inside of the connection duct. The flow pattern inside of the connection duct is evaluated under different the duct lengths and the baffle arrays. In case of the reference geometry the RMS value of inside flow was 56.7%, and the value was decreased to 30.1% by controlling the lengths of duct. The effects of baffle was also evaluated, the RMS value of flow could be decreased 55.2% and so on. But the pressure drop across the baffles becomes high and the system efficiency becomes lower.

가시화기법을 이용한 다단형 하이드로 사이클론 어란 (魚卵) 집진장치의 개선에 관한 연구 (An advanced study of multi-stage type hydrocyclone dust collector for fish egg collecting using Visualization)

  • 최은희;편용범;이승헌;이경훈
    • 수산해양기술연구
    • /
    • 제53권4호
    • /
    • pp.404-412
    • /
    • 2017
  • A centrifugal cyclone dust collecting apparatus includes a hydro cyclone dust collecting apparatus for separating solid or liquid using liquid or suspension as a medium. In this study, the formation mechanism and improvement of air core and inner air layer were confirmed through Particle Image Velocimetry. These results showed that the modified experimental model was designed in the conventional method suitable for the separation of juvenile fish and eggs. The inlet speed of the multi-stage hydrocyclone dust collector, which can increase the inlet velocity and minimize floatage in the turbulence chamber, was increased from 0.15 to 0.30 m/s. As a result, the air core was stably formed, the inner air layer was increased with increasing speed. In addition, the dust collecting efficiency of egg and juvenile fish was 97.8% on average, It can infer that this system confirmed the ability to efficiently collect particles of $40{\mu}m$ or more.

디젤 엔진용 싸이클론 내부 수치 해석 (A Numerical Study on Axial Inlet Cyclone for Diesel Engine)

  • 김성광;손창석;김인관
    • 동력기계공학회지
    • /
    • 제10권2호
    • /
    • pp.16-21
    • /
    • 2006
  • On this study, numerical analysis was performed for the 3 dimensional flow field of gas and particle phase for axial inlet cyclone, a part of dust collector. We applied FVM to visualize the gas phase. The flow was solved using ${\kappa}-{\varepsilon}$ turbulence model. The major parameters considered in this study were helical guide vane, inner diameter, length. Particle trajectory calculations were performed for the particle sizes of $5{\mu}m{\sim}75{\mu}m$. The distribution curve of particle sizes was made of Rosin-Rammler function. The simulation results show various gas flows, particle trajectories on numerical models.

  • PDF

30CMM급 태양기공 전기집진 설비의 실내분진 정화 능력에 관한 실험연구 (An Experimental Study of 30CMM Solar Transpired Collector and Cyclone(STCC) System on Indoor Air Dust Removal Performance)

  • 노지희;박상현;강은철;이의준
    • 한국태양에너지학회 논문집
    • /
    • 제25권3호
    • /
    • pp.37-45
    • /
    • 2005
  • Higher requirement of advanced building design code and the development of construction technique have resulted in more thermal and air tight buildings. This has caused the sick building syndrome in a indoor air quality has been relatively getting worse. A new concept with a solar fresh air heating and electrostatic precipitator or called as STCC(Solar Transpired Collector and Cyclone) has been proposed to solve this IAQ issue. This paper describes the assessment study of STCC system under different outdoor airflow rates. The experiment was carried out under real condition with 30CMM STCC system test facility. Incense smoke was used to study the particle concentration decay trends under outdoor airflow rates 0CMM, 10CMM, 20CMM, 30CMM, with applied voltages of 5kV and 15kV for collecting and discharging electrodes of an Electrostatic Precipitator. Result shows that the particle decay increases by increasing the outdoor airflow rates. The collection efficiency, dust cleaning effectiveness(P) and application area calculation result comparisons have also been studied. This factors could be used to estimate how a dust of indoor air quality(IAQ) and removed for a building space with a STCC system.

오일미스트용 사이클론 집진기에 관한 기초 설계 -오일미스트 및 슬러지 입자 융합연구- (Fundamental Design of Cyclone Collector for Oil Mist)

  • 장성철;안휘웅;이찬규
    • 한국생산제조학회지
    • /
    • 제22권2호
    • /
    • pp.223-227
    • /
    • 2013
  • Dust collecting performance of cyclone collector for oil mist was alalyzed in the study. The purposes of using cutting fluid during cutting have been colling, lubricating, chip washing and anti-corroding. However, the present manufactaring industry restricts the use of cutting fluid because cutting fluid confains poisonous substances which are harmful to the human body. Also, the optimum design oil-mist collector. The new oil mist collector was designed. In the near future, this device must be tested in the real machining center and CNC machine. Cutting using oil-mist showed better cutting characteristics than dry, air and fluid cutting with respect to by cutting force, tool wear and surface roughness. The model(A, B Type cyclone) of the set of fixture and alveolus are made by using a CAE software. Finally, we have obtained a model A Type solution by using orthogonal array. Therefore, it could be confirmed that as the model-A was increased and model-B was decreased, cut diameter was decreased.

사이클론 청소기 내부 유동에 관한 수치해석적 연구 (Numerical Study on the Internal Flow in the Cyclone Vacuum Cleaner)

  • 이찬현;장혁상
    • 청정기술
    • /
    • 제20권3호
    • /
    • pp.283-289
    • /
    • 2014
  • 가정용 진공청소기는 기본적으로 집진장치(dust collector), 프리 필터(pre filter), 모터(motor), 배기 필터(exhaust filter)의 구조를 가지며, 흡입된 먼지가 포함된 공기는 이러한 구조를 지나 깨끗한 공기가 되어 대기로 방출된다. 본 연구에서는 실생활에 사용되고 있는 구조가 다른 2개의 사이클론 청소기를 선정하여 사이클론 청소기 내 집진장치의 내부 공기 유동에 대해 전산유체역학을 적용하여 집진성능을 평가하고자 하였다. 사이클론 콘(cyclone cone) 영역에서 공기의 유선(streamline)을 해석한 결과, 사이클론 콘 영역에서 상당한 선회수를 가지는 것을 확인하였다. 특정 형상의 청소기에 대한 전산해석 결과에서 출구에서의 속도 분포가 매우 불균일한 결과를 나타내었고 이로 인해 집진성능에 악영향이 나타남이 파악되었다. 이 문제를 해결하기 위해 집진장치 형상에 추가적으로 배플을 설치하여, 달라진 속도 분포에 의한 속도 RMS (Root Mean Square) 값의 개선을 평가하였다.

사이클론 집진장치 내부의 압력강하에 대한 전산해석과 이론식의 결과 비교 (Theoretical and Computation Analysis on the Pressure Drop in the Cyclone Dust Collector)

  • 현대근;장혁상
    • 청정기술
    • /
    • 제20권3호
    • /
    • pp.263-268
    • /
    • 2014
  • 본 연구에서는 집진성능이 다른 6개의 서로 다른 형상의 사이클론 집진장치 내에서 이루어지는 압력강하에 대해 기존이론식과 CFD (computational fluid dynamics) 해석 결과를 비교하였다. 이론 계산에는 Shepherd와 Lapple (1939, 1940), First (1950), Alexander (1949), Stairmand (1949) 그리고 Barth (1956)의 식이 사용되었다. CFD 연구에서 난류 유동을 해석하기 위해 standard k-epsilon 모델을 사용하였고, 유체는 $25^{\circ}C$ 공기, 입구에서 유속은 10 m/s, 온도는 $25^{\circ}C$로 설정하였다. CFD 해석 결과 사이클론의 형상과 관계없이 압력분포는 일정한 형태를 나타내었다. 하지만 이론식에 의한 추정의 경우 형상에 따른 압력강하는 큰 차이를 보였으며, 오직 First (1950)의 식이 CFD 결과와 아주 유사한 결과를 나타내었다.