• 제목/요약/키워드: Cyclic Moment

검색결과 357건 처리시간 0.022초

천장 브래킷형 모듈러 시스템의 접합부 내진 성능과 설계 프로세스 (Seismic Performance and Design Process of a Ceiling Bracket-Typed Modular Connection)

  • 이승재;강창훈;박재성;곽의신;손수덕
    • 한국공간구조학회논문집
    • /
    • 제20권3호
    • /
    • pp.27-34
    • /
    • 2020
  • This paper examines the seismic performance and structural design of the ceiling bracket-type modular connection. The bracket-type system reduces the cross-sectional area loss of members and combines units using fitting steel plate, and it has been developed to be fit for medium-story and higher-story buildings. In particular, this study conducted the cyclic loading test for the performance of the C-type and L-type brackets, and compared the results. The test results were also compared with the commercial FEA program. In addition, the structural design process for the bracket-type modular connection was presented. The two connections, proposed as a result of the test results, were all found to secure the seismic performance level of the special moment steel frame. In the case of initial stiffness, the L-type bracket connection was found to be great, but in the case of the maximum moment or fully plastic moment, it was different depending on the loading direction.

Analytical investigation on moment-rotation relationship of through-tenon joints with looseness in ancient timber buildings

  • Xue, Jianyang;Qi, Liangjie;Dong, Jinshuang;Xu, Dan
    • Earthquakes and Structures
    • /
    • 제14권3호
    • /
    • pp.241-248
    • /
    • 2018
  • To study the mechanical properties of joints in ancient timber buildings in depth, the force mechanism of the through-tenon joints was analyzed, also the theoretical formulas of the moment-rotation angles of the joints with different loosening degrees were deduced. To validate the rationality of the theoretical calculation formulas, six joint models with 1/3.2 scale ratio, including one intact joint and five loosening joints, were fabricated and tested under cyclic loading. The specimens underwent the elastic stage, the plastic stage and the destructive stage, respectively. At the same time, the moment-rotation backbone curves of the tenon joints with different looseness were obtained, and the theoretical calculation results were validated when compared with the experimental results. The results show that the rotational moment and the initial rotational stiffness of the tenon joints increase gradually with the increase of the friction coefficient. The increase of the tenon section height can effectively improve the bearing capacity of the through-tenon joints. As the friction coefficient of the wood and the insertion length of the tension increase, the embedment length goes up, whereas it decreases with the increase of section height. With the increase of the looseness, the bearing capacity of the joint is reduced gradually.

3D finite element modelling of composite connection of RCS frame subjected to cyclic loading

  • Asl, Mohammad Hossein Habashizadeh;Chenaglou, Mohammad Reza;Abedi, Karim;Afshin, Hassan
    • Steel and Composite Structures
    • /
    • 제15권3호
    • /
    • pp.281-298
    • /
    • 2013
  • Composite special moment frame is one of the systems that are utilized in areas with low to high seismicity to deal with earthquake forces. Composite moment frames are composed of reinforced concrete columns (RC) and steel beams (S); therefore, the connection region is a combination of steel and concrete materials. In current study, a three dimensional finite element model of composite connections is developed. These connections are used in special composite moment frame, between reinforced concrete columns and steel beams (RCS). Finite element model is discussed as a most reliable and low cost method versus experimental procedures. Based on a tested connection model by Cheng and Chen (2005), the finite element model has been developed under cyclic loading and is verified with experimental results. A good agreement between finite element model and experimental results was observed. The connection configuration contains Face Bearing Plates (FBPs), Steel Band Plates (SBPs) enveloping around the RC column just above and below the steel beam. Longitudinal column bars pass through the connection with square ties around them. The finite element model represented a stable response up to the first cycles equal to 4.0% drift, with moderately pinched hysteresis loops and then showed a significant buckling in upper flange of beam, as the in test model.

유한요소 해석을 이용한 WUF-W 접합부 최적의 파단 예측 반응지표 선정 (Appropriate Response Index for Predicting Rupture in WUF-W Connections using FEA)

  • 한상환;김영우;김태오
    • 한국지진공학회논문집
    • /
    • 제21권5호
    • /
    • pp.205-213
    • /
    • 2017
  • The WUF-W moment connection is a pre-qualified connection that can be used for special moment frames specified in current seismic design specifications. Since the stress distribution near the connection varies according to access hole configuration, the cyclic performance of WUF-W connections is strongly affected by the access hole configurations. To evaluate the connection performance according to various access hole configurations, it is expensive to conduct experiments with many connection specimens. Instead, finite element analyses (FEA) can be performed. Throughout the FEA, stress and strain distribution in the connection can be monitored at each loading step. The purpose of this study is to construct nonlinear 3-dimensional FE models for accurately predicting the cyclic behavior of WUF-W connections. For predicting connection fracture using FEA, an appropriate response index detecting the incidence of connection rupture is proposed.

Cyclic Behavior of Timber Column Concealed Base Joint

  • Humbert, Jerome;Lee, Sang-Joon;Park, Joo-Saeng;Park, Moon-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권2호
    • /
    • pp.123-133
    • /
    • 2013
  • This paper presents experimental and numerical tests on a recently developed timber column concealed base joint. This joint was designed to replace the wood-wood connection found in the post-and-beam structure of Hanok, the traditional Korean timber house. The use of metallic connectors provides an increased ductility and energy dissipation for a better performance under reversed loading, especially seismic. In this study, we investigate the performance of the joint under pseudo-static reversed cyclic moment loading through the study of its ductility and energy dissipation. We first perform experimental tests. Results show that the failure occurs in the metallic connector itself because of stress concentrations, while no brittle fracture of wood occur. Subsequent numerical simulations using a refined finite element model confirm these conclusions. Then, using a practical modification of the joint configuration with limited visual impact, we improve the ductility and energy dissipation of the joint while retaining a same level of rotational strength as the originally designed configuration. We conclude that the joint has a satisfying behavior under reversed moment loading for use in earthquake resistant timber structure in low to moderate seismicity areas like Korea.

Endochronic simulation for the response of 1020 carbon steel tubes under symmetric and unsymmetric cyclic bending with or without external pressure

  • Lee, Kuo-Long;Hsu, Chien-Min;Hung, Chao-Yu
    • Steel and Composite Structures
    • /
    • 제8권2호
    • /
    • pp.99-114
    • /
    • 2008
  • This paper presents the theoretical simulation of the response of 1020 carbon steel tubes subjected to symmetric and unsymmetric cyclic bending with or without external pressure by using the endochronic theory. Experimental data of 1020 carbon steel tubes tested by Corona and Kyriakides (1991) were used for evaluating the theoretical simulation. Several cases were considered in this study, they were symmetric bending without external pressure, symmetric bending with external pressure, unsymmetric bending without external pressure, and unsymmetric bending with external pressure. The responses of the moment-curvature, ovalization-curvature and ovalization-number of cycles with or without external pressure were discussed. It has been shown that the theoretical simulations of the responses correlate well with the experimental data.

수평반복하중 실험을 이용한 근입된 얕은 기초의 회전거동 메커니즘 평가 (Evaluation of Rocking Mechanism for Embedded Shallow Foundation via Horizontal Slow Cyclic Tests)

  • 고길완;하정곤;박헌준;김동수
    • 한국지반공학회논문집
    • /
    • 제32권8호
    • /
    • pp.47-59
    • /
    • 2016
  • 얕은 기초의 회전거동은 지진 시 상부 구조물의 지진하중을 줄이는 효과적인 방법으로 대두되고 있다. 그러나 회전거동의 메커니즘에 대한 이해부족과 항복거동으로 인한 지반변형 때문에 시공에 적용되지 못하고 있다. 본 연구에서는 원심모형실험을 이용한 수평반복하중 실험을 통해 세장비가 다른 시스템의 근입된 얕은 기초의 회전거동 특성을 평가하였다. 실험결과를 통해 기초의 회전거동으로 인한 하부지반면의 원형현상을 관찰하였으며, 이로 인해 기초의 최대 전도모멘트가 기초의 극한 모멘트 지지력과 같아지는 것을 알 수 있었다. 기초 저면에서 관측된 토압변화를 통해 항복거동으로 인한 수평거동과 회전거동의 연결(coupling)과 분리(decoupling)현상을 볼 수 있었다. 또한 기초의 회전각이 증가할수록 지반의 비선형성과 에너지 감쇠가 커짐을 알 수 있었고, 근입된 기초의 극한 모멘트 지지력이 지표면에 놓인 기초의 극한 모멘트 지지력보다 더 커지는 것을 확인하였다. 본 연구를 통해 기초의 회전거동을 이용한 내진 설계 시 보다 정확하고 적절한 기초의 극한 모멘트 지지력을 제시할 수 있을 것이라 판단된다.

Strength upgrading of steel storage rack frames in the down-aisle direction

  • El Kadi, Bassel;Cosgun, Cumhur;Mangir, Atakan;Kiymaz, Guven
    • Steel and Composite Structures
    • /
    • 제23권2호
    • /
    • pp.143-152
    • /
    • 2017
  • This paper focuses on the seismic performance of pallet-type steel storage rack structures in their down aisle direction. As evidenced by experimental research, the seismic response of storage racks in the down-aisle direction is strongly affected by the nonlinear moment-rotation response of the beam-to-column connections. In their down-aisle direction, rack structures are designed to resist lateral seismic loads with typical moment frames utilizing proprietary beam-to-column moment-resisting connections. These connections are mostly boltless hooked type connections and they exhibit significantly large rotations resulting in large lateral frame displacements when subjected to strong ground motions. In this paper, typical hooked boltless beam-to-column connections are studied experimentally to obtain their non-linear reversed cyclic moment-rotation response. Additionally, a compound type connection involving the standard hooks and additional bolts were also tested under similar conditions. The simple introduction of the additional bolts within the hooked connection is considered to be a practical way of structural upgrade in the connection. The experimentally evaluated characteristics of the connections are compared in terms of some important performance indicators such as maximum moment and rotation capacity, change in stiffness and accumulated energy levels within the cyclic loading protocol. Finally, the obtained characteristics were used to carry out seismic performance assessment of rack frames incorporating the tested beam-to-column connections. The assessment involves a displacement based approach that utilizes a simple analytical model that captures the seismic behavior of racks in their down-aisle direction. The results of the study indicate that the proposed method of upgrading appears to be a very practical and effective way of increasing the seismic performance of hooked connections and hence the rack frames in their down-aisle direction.

브래킷형 완전강접합 모듈러 시스템의 반복가력실험과 해석적 평가 (Cyclic Loading Test and an Analytical Evaluation of the Modular System with Bracket-typed Fully Restrained Moment Connections)

  • 박재성;강창훈;손수덕;이승재
    • 대한건축학회논문집:구조계
    • /
    • 제34권3호
    • /
    • pp.19-28
    • /
    • 2018
  • Key factors that ensure competitiveness of modular unit include consistent high quality and connection condition that ensures high structural performance while minimizing the overall scale of the on-site process. However, it is difficult to evaluate the structural performance of the connection of modular unit, and its structural analysis and design method can be different depending on the connection to its development, which affects the seismic performance of its final design. In particular, securing the seismic performance is the key to designing modular systems of mid-to-high-rise structure. In this paper, therefore, the seismic performance of the modular system with bracket-typed fully restrained moment connections according to stiffness and the shapes of various connection members was evaluated through experimental and analytical methods. To verify the seismic performance, a cyclic loading test of the connection joint of the proposed modular system was conducted. As a result of this study, theoretical values and experimental results were compared with the initial stiffness, hysteresis behavior and maximum bending moment of the modular system. Also, the connection joint was modeled, using the commercial program ANSYS, which was then followed by finite element analysis of the system. According to the results of the experiment, the maximum resisting force of the proposed connection exceeded the theoretical parameters, which indicated that a rigid joint structural performance could be secured. These results almost satisfied the criteria for connection bending strength of special moment frame listed on KBC2016.

모멘트 링크보의 이력 거동 (Cyclic Behavior of Moment Link Beams)

  • 김태영;김상섭;김영호;정회용;김규석
    • 한국강구조학회 논문집
    • /
    • 제15권3호
    • /
    • pp.261-269
    • /
    • 2003
  • 편심브레이스골조의 설계에서 가장 중요한 인자는 링크보의 길이이다. 링크보의 길이에 따라 편심브레이스골조의 거동과 파괴메카니즘이 결정된다. 링크보의 길이가 짧아져 전단력에 의해 소성화되면 중심브레이스골조와 대등한 수평방향강성과 모멘트 연성골조의 연성을 동시에 확보할 수 있다. 또한 링크보의 길이가 길어지게 되면 링크보는 모멘트에 의해 소성화 되어 연성적인 거동을 확보할 수 없게 된다. 근래에 이르러 건축계획적인 측면에서는 링크보의 길이가 길어지는 것이 입면 및 단면계획이 용이하며, 그 필요성이 증대되고 있지만, 모멘트 링크에 대한 기존의 연구가 많이 수행되어 있지 않으며, 이와 관련된 자료가 부족한 실정이다. 본 연구에서는 실험을 통해 다양한 접합디테일을 가진 모멘트링크보의 거동을 규명하고 모멘트링크보의 거동을 개선시킬 수 있는 접합디테일을 제시하고자 한다. 4개의 접합 디테일을 가진 총 16개의 실험체를 계획하여 이력거동 실험을 수행하였다.