• Title/Summary/Keyword: Cycle change-over

Search Result 206, Processing Time 0.022 seconds

Fiber Optic AC Voltage Sensor Using Fringe Counting (간섭무늬의 변화갯수 측정을 이용한 광섬유 교류전압센서)

  • 김봉규;김병윤;김만식
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.158-165
    • /
    • 1994
  • A fiber optic voltage sensor is demonstrated with a new signal processing scheme that displays the magnitude and the waveform of applied voltage with immunity from the signal frequency change. The sensor is based on a Mach-Zehnder interferometer with a PZT phase modulator as a sensing element. We observed a linear relationship between applied voltage and the number of fringe shift during a half cycle of the ac signal. The temperature dependence of the sensor output is experimentally evaluated over the temperature range from $-20^{\circ}C to 80^{\circ}C$. It is demonstrated that the detrimental polarization modulation effect can be overcome by using polarization maintaining fibers or a half-wave plate. plate.

  • PDF

An Experimental Study on the Performance and the Exhaust Emissions of Gasoline Engine Using Water-Gashol Blends as a Fuel (물-가스홀 혼합물을 연료로 사용한 가솔린기관의 성능 및 배기성분에 관한 실험적 연구)

  • 노상순;배명환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.25-38
    • /
    • 1984
  • Since the energy shock in 1973, there have been wide studies for the developments of the alternative energy source, the rationalization of the energy utilization and the energy economy because of the recognition of the limitation of energy source all over the world. This study is experimentally examined in and compared with the engine performance of output, torque and fuel consumption rate, and the exhaust emissions with the change of engine rmp in the cases of using water-gashol blends, gashol and gasoline as a fuel in a conventional 4 cycle 4 cylinder gasoline engine. In the case of using water-gashol blends, it is installed by the exhaust manifold pipe into the intake manifold, and water is injected from nozzle fitted up the air horn of the carburetor. The results are obtained as follows; 1. In the case of an addition with water, the engine output and the torque are little difference with the case of gasoline. 2. The fuel consumption rate is decreased as compared with the case of gasoline. Especially, the decrease in quantity is remarkable at the low rpm. 3. The exhaust emissions are remarkably decreased as compared with the case of gasoline. Especially, decreases of CO and HC in quantity are remarkable at the low rpm, and a decrease of No/sub x/ in quantity is remarkable at the high rpm. 4. There is a moderate condition of operation because the producing factors of NO/sub x/ and CO, HC are contrary to each other.

  • PDF

A Synoptic and Climatological Comparison of Record-breaking Heat Waves in Korea and Europe (한반도와 유럽에서 발생한 폭염의 종관기후학적 특성 비교)

  • Kim, Jiyoung;Lee, Dae-Geun;Kysely, Jan
    • Atmosphere
    • /
    • v.18 no.4
    • /
    • pp.355-365
    • /
    • 2008
  • Synoptic and climatological characteristics of heat waves over Korea and Europe as well as their biometeorological impacts were compared. In July of 1994, excess deaths of about 2,388 in the population of South Korea are estimated by the modified excess death calculation algorithm ofKysely (2004). The excess deaths correspond to the net mortality increase of 12.5% in July of 1994 if we compare the estimated value to the expected number of deaths in this month (i.e., about 19,171). The comparative study of heat waves in Korea and Europe shows that the record-breaking heat waves in both regions are closely associated with prolonged droughts. In particular, reduction of soil moisture, precipitation and cloud cover and enhancement of insolation during the drought periods are very likely to be related to the increase in the intensity and the duration ofheat waves. Climate models predict that the frequency, intensity, and duration of heat waves in the 21 st century will be greatly enhanced in both areas. In order to reduce the biometeorological and socioeconomic impacts due to heat waves, not only the development of heat-related mortality prediction model that can be widely applied to many climate regimes, but also studies on the climatological association between extreme temperatures and abnormal hydrological cycle are needed.

Investigation of Cooling Effect of Flow Velocity and Cooler Location in Thermal Nanoimprint Lithography

  • Lee, Woo-Young;Lee, Ki Yeon;Kim, Kug Weon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.4
    • /
    • pp.37-42
    • /
    • 2012
  • Nanoimprint lithography (NIL) has attracted broad interest as a low cost method to define nanometer scale patterns in recent years. A major disadvantage of thermal NIL is the thermal cycle, that is, heating over glass transition temperature and then cooling below it, which requires a significant amount of processing time and limits the throughput. One of the methods to overcome this disadvantage is to improve the cooling performance in NIL process. In this paper, the performance of the cooling system of thermal NIL is numerically investigated by SolidWorks Flow Simulation program. The calculated temperatures of nanoimprint device were verified by the measurements. By using the analysis model, the effects of the change of flow velocity and cooler location on the cooling performance are investigated. For the 6 cases (0.1 m/s, 0.5 m/s, 1 m/s, 3 m/s, 5 m/s, 10 m/s) of flow velocity and for the 6 cases of distances (50 mm, 40 mm, 30 mm, 20 mm, 10 mm, 1 mm) of cooler location, the heat conjugated flow analyses are performed and discussed.

Evaluation of the Total Column Ozone in the Reanalysis Datasets over East Asia (동아시아 지역 오존 전량 재분석 자료의 검증)

  • Han, Bo-Reum;Oh, Jiyoung;Park, Sunmin;Son, Seok-Woo
    • Atmosphere
    • /
    • v.29 no.5
    • /
    • pp.659-669
    • /
    • 2019
  • This study assesses the quality of the total column ozone (TCO) data from five reanalysis datasets against nine independent observation in East Asia. The assessed datasets are the ECMWF Interim reanalysis (ERAI), Monitoring Atmosphere Composition and Climate reanalysis (MACC), Copernicus Atmosphere Monitoring Service reanalysis (CAMS), the NASA Modern-Era Retrospective analysis for Research and Applications, Version2 (MERRA2), and NCEP Climate Forecast System Reanalysis (CFSR). All datasets reasonably well capture the spatial distribution, annual cycle and interannual variability of TCO in East Asia. In particular, characteristics of TCO according to the latitude difference were similar at all points with a maximum bias of less than about 4%. Among them, CAMS and CFSR show the smallest mean bias and root-mean square error across all nine ground-based observations. This result indicates that while TCO data in modern reanalyses are reasonably good, CAMS and CFSR TCO data are the best for analysing the spatio-temporal variability and change of TCO in East Asia.

Firm's Economic Efficiency and Critical Weather Information in Distribution Industry by Climate Change (기후변화에 따른 유통산업의 핵심 기상요인과 기업의 경제적 효율성)

  • Lee, Joong-Woo;Ko, Kwang-Kun;Jeon, Jin-Hwan
    • Journal of Environmental Science International
    • /
    • v.19 no.6
    • /
    • pp.787-797
    • /
    • 2010
  • Nowadays meteorological information is systemized as a useful knowledge which has a significant effect on the overall industrial domains over the simple data. The distribution industry, which has the short life cycle, depends on the meteorological information at the strategic level. However, it is necessary to pay attention to the continuous investment in meteorological information because there is a hostility to paying for a service, particularly it does not provide accurate and reliable information. Therefore, the purpose of this study is to increase the usefulness of meteorological information in the distribution industry for its economic effectiveness from the core meteorological factors. We found significant meteorological factors (temperature, precipitation, disaster) that have a critical influence on the distribution industry through the hierarchical analysis process, and their importance according to the type of distribution channels, such as department store, large-scale discount store, convenience store, and home shopping. We performed the AHP analysis with 103 survey samples by middle managers from the various distribution channels. We found that precipitation is the critical meteorological factor across the distribution industry. Based on this result, we stress the difference in the level of the meteorological information in order for the effectiveness of each type of distribution channels.

Fuzzy Droop Control considering SOC Balancing of BESSs (다수 BESS의 SOC Balancing을 고려한 퍼지 드룹 제어)

  • Han, Seong-Geun;Yoo, Hyeong-Jun;Kim, Hak-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.4
    • /
    • pp.616-622
    • /
    • 2015
  • A microgrid which is composed of distributed generation systems, energy storage systems and loads is operated in the grid-connected mode and in the islanded mode. Especially, in the islanded mode, a microgrid should maintain frequency in the allowed range. The frequency is decided by a balance between power supply and power demand. In general, the frequency is controlled by using battery energy storage systems (BESSs) in the microgrid. Especially, droop control is applied to controlling BESSs in the microgrid. Meanwhile, over-charging and deep-discharging of BESS in operation and control cause life-shortening of batteries. In this paper, a fuzzy droop control is proposed to change droop gains adaptively by considering state of charge (SOC) of BESSs to improve the life cycle of the battery. The proposed fuzzy droop control adjusts droop gains based on SOC of BESSs in real time. In other to show the performance of the proposed fuzzy droop control, simulation based on Matlab/Simulink is performed. In addition, comparison of the convention droop control and the proposed fuzzy droop control is also performed.

Analysis of Damage Patterns for Gas Turbine Combustion Liner according to Model Change (모델 변천에 따른 가스터빈 연소기 라이너의 부위별 손상유형 분석)

  • Kim, Moon-Young;Yang, Sung-Ho;Park, Sang-Yeol;Kim, Sang-Hoon;Park, Hye-Sook;Won, Jong-Beom
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2862-2867
    • /
    • 2008
  • High-temperature components of gas turbine operated for certain period of time can be reused by being repaired or rejuvenated. In case of the gas turbine combustion liners, the biggest and the most important one in the high-temperature components, come in a repair shop after operated for 8,000 or 12,000 hours according to the model and go through the repair and rejuvenation in order to be reused. A stated combustion liner is the first channel which has the combustion gas reached a nozzle from a fuel nozzle. Materials and coating properties of old and new model combustion liners were investigated. To repair these components after the visual inspection, the coatings of combustion liners were removed and then FPI(Fluorescent Penetrant Inspection), a kind of the NDI(Non-Destructive Inspection), was conducted. Damage patterns and the number of the damaged components were classified and analyzed based on data provided from the visual inspection over a long period of time. Focusing on the difference between old model and new model combustion liners, we analyzed the damage distribution and changes and consequently concluded that new model combustion liner would increase repair rate.

  • PDF

The Effects of Sulfite on the Greening of Etiolated Barley (Mordeum vuigare L.) Seedling (Sulfite가 보리(Hordeum vulgare L.) 유식물의 녹화에 미치는 영향)

  • 박강은;정화숙
    • Journal of Environmental Science International
    • /
    • v.7 no.2
    • /
    • pp.133-140
    • /
    • 1998
  • To investigate the effects of sulfite on the chloroplast development, etiolated barley seedlings were treated with 100 mM sulfite solution every 3 hour by spraying during 96 hours greening Period. The effects were determined by chlorophyll a, b and carotenoids contents, photosynthetic electron transport activity, chlorophyll fluorescence yield and fluorescence quenching parameters. The contents of chlorophyll a and carotenoids were decreased than that of control by treatment of salfite over 48 hours greening. PS II Is more sensitive to sulfite than PS I Is. And by the addition of DPC to the chloroplasts of the barley seedling treated with sulfite, the photoreduction of DCPIP was not recovered. In greening with suite treated barley leaves, Fo, Fv and Nlh ratio were decreased with little difference from that of control. But qP, qNP and qR were lowed in comparison with those of controls whereas qE was markedly higher than that of control. Especially, It is Interesting that qR was decreased markedly compared to that of control. The results in the change of PS I activity, Nf and qP suggest that the strate of Inhibition by suite Is carbon dioxide reduction cycle.

  • PDF

Analysis of a Change in the Water-Balance after Application of Decentralized Rainwater Management Facilities - Based on the Results of the Hydrologic Modeling using the CAT - (분산식 빗물관리시설 적용에 따른 물수지 변화 분석 연구 - CAT을 이용한 수문모델링 결과를 토대로 -)

  • Lee, Tae-Goo;Han, Young-Hae
    • KIEAE Journal
    • /
    • v.11 no.2
    • /
    • pp.59-65
    • /
    • 2011
  • To analyze changes in the water-balance before and after using decentralized rainwater management facilities, this study carried out hydrologic modeling based on data including roof planting, rainwater use, infiltration and detention facilities applied to the sites. The results of the analysis are as follows: First, the total runoff quantity after facility installation was about 24% less than before. In particular, it showed that the surface runoff declined significantly. Second, the analysis of the effects of different decentralized rainwater management facilities revealed that the rooftop planting contributed to about a 3.5 times increase in actual evaporation than before. Third, the analysis of the effect of decentralized management facilities by different rainfall events showed that it turned to have about a 30% decreasing effect after facility installation for a monthly rainfall over 500mm or so and about 50% declining effect for a monthly rainfall about 200mm. As discussed above, the study confirmed that it is important to implement decentralized rainwater management facilities to improve inevitable changes in water-balance arising from development as it would be a significant alternative for sustainable urban development.