• 제목/요약/키워드: Cycle Society

검색결과 14,085건 처리시간 0.051초

담수화 공정과 이산화탄소 냉동 시스템의 복합사이클 해석 (Analysis of combined cycle for desalination process and $CO_2$ refrigeration system)

  • 신지영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권1호
    • /
    • pp.41-48
    • /
    • 2000
  • The characteristics of a combined cycle for the production of fresh water and air-conditioning was analyzed. The combined cycle consisted of an open water cycle and a $CO_2$ refrigeration cycle interlinked in the pre-heater of the water cycle, which is the condenser of the refrigeration cycle. The oprating conditions and criteria for the fresh water production and air-conditioning was described and their effects on the total system were evaluated. The results indicated an increase of desalinated water with the increase of hot water temperature, which resulted in the decrease of cooling capacity of the refrigeration system in this study. However, the energy saving correspond to the pre-heating of the water cycle by the condensing of the refrigeration system shows the avilable advantage of the proposed cycle as compared to other single purpose plants for desalination.

  • PDF

2상류이젝터를 이용하는 $CO_{2}$ 냉동사이클의 성능해석 (Performance analysis of $CO_{2}$ refrigeration cycle with two-phase ejector)

  • 이윤환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권8호
    • /
    • pp.946-952
    • /
    • 2005
  • The $CO_{2}$ refrigeration cycle is expected to reduce the compressor work and increase the COP by applying two-phase ejector as a device for the recovery of dissipated expansion energy. In this study, the performance of the cycle was simulated and effects of the ejector shapes on the performance of the $CO_{2}$ refrigeration cycle were investigated. The following results were obtained through the cycle simulation. The COP of the $CO_{2}$ refrigeration cycle with two-phase ejector flow which expansion is occured in the isentropic manner is increased by a maximum of 24 $\%$ than the basic cycle with expansion valve If the velocity nonequilibrium in the mixing process is assumed the COP of the cycle is increased with the increase of the length and the decrease of the section area of the mixing tube. The best cycle performance is obtained when the divergent angle of diffuser is 7.

RNA-sequencing Profiles of Cell Cycle-Related Genes Upregulated during the G2-Phase in Giardia lamblia

  • Kim, Juri;Shin, Mee Young;Park, Soon-Jung
    • Parasites, Hosts and Diseases
    • /
    • 제57권2호
    • /
    • pp.185-189
    • /
    • 2019
  • To identify the component(s) involved in cell cycle control in the protozoan Giardia lamblia, cells arrested at the G1/S- or G2-phase by treatment with nocodazole and aphidicolin were prepared from the synchronized cell cultures. RNA-sequencing analysis of the 2 stages of Giardia cell cycle identified several cell cycle genes that were up-regulated at the G2-phase. Transcriptome analysis of cells in 2 distinct cell cycle stages of G. lamblia confirmed previously reported components of cell cycle (PcnA, cyclin B, and CDK) and identified additional cell cycle components (NEKs, Mad2, spindle pole protein, and CDC14A). This result indicates that the cell cycle machinery operates in this protozoan, one of the earliest diverging eukaryotic lineages.

S-box 형태의 다 수열 발생기에 관한 연구 (On a Multiple-cycle Binary Sequence Genrator Based on S-box)

  • 이훈재
    • 한국정보처리학회논문지
    • /
    • 제7권5호
    • /
    • pp.1474-1481
    • /
    • 2000
  • The number of keystream cycle sequences has been proposed as a characteristic of binary sequence generator for cryptographic application, but in general the most of binary sequence generators have a single cycle. On the other hand, S-box has been used to block cipher for a highly nonlinear element and then we apply it to the stream cipher with a high crypto-degree. In this paper, we propose a multiple-cycle binary sequence generator based on S-box which has a high nonlinearity containing SAC property and analyze its period, linear complexity, randomness and the number of keystream cycle sequences.

  • PDF

태양열과 재열기를 사용한 VI heat pump의 성능 특성에 관한 연구 (Heating Performance Characteristics of Heat Pump with VI cycle using Re-Heater and Solar-Assisted)

  • 이진국;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제35권6호
    • /
    • pp.25-33
    • /
    • 2015
  • In this study, heating performance of the air-cooled heat pump with vapor-injection (VI) cycles, re-heater and solar heat storage tank was investigated experimentally. Devices used in the experiment were comprised of a VI compressor, re-heater, economizer, variable evaporator, flat-plate solar collector for hot water, thermal storage tank, etc. As working fluid, refrigerant R410A for heat pump and propylene glycol (PG) for solar collector were used. In this experiment, heating performance was compared by three cycles, A, B and C. In case of Cycle B, heat exchange was conducted between VI suction refrigerant and inlet refrigerant of condenser by re-heater (Re-heater in Fig. 3, No. 3) (Cycle B), and Cycle A was not use re-heater on the same operating conditions. In case of Cycle C, outlet refrigerant from evaporator go to thermal storage tank for getting a thermal energy from solar thermal storage tank while re-heater also used. As a result, Cycle C reached the target temperature of water in a shorter time than Cycle B and Cycle A. In addition, it was founded that, as for the coefficient of heating performance($COP_h$), the performance in Cycle C was improved by 13.6% higher than the performance of Cycle B shown the average $COP_h$ of 3.0 and by 18.9% higher than the performance of Cycle A shown the average $COP_h$ of 2.86. From this results, It was confirmed that the performance of heat pump system with refrigerant re-heater and VI cycle can be improved by applying solar thermal energy as an auxiliary heat source.

내적가역 사이클의 최대출력 조건 (The Maximum Power Condition of the Endo-reversible Cycles)

  • 정평석;김수연;김중엽;류제욱
    • 대한기계학회논문집
    • /
    • 제17권1호
    • /
    • pp.172-181
    • /
    • 1993
  • 본 연구에서는 이 사이클 주위에 열전달이 추가된 열기관에 대하여 최대출력 조건 등을 구하고, 내부의 사이클이 각각 타노 사이클 및 브레이튼 사이클인 경우의 결과와 비교하여, 내적가역 최대출력 사이클들의 특성을 밝히고자 한다.

지체도 최소화를 위한 주기변동기반 동적신호시간 결정모헝 개발 (Development of a Cycle-free Based, Cooridinated Dynamic Signal Timing Model for Minimizing Delay (Using Genetic Algorithm))

  • 이영인;최완석;임재승
    • 대한교통학회지
    • /
    • 제19권1호
    • /
    • pp.115-129
    • /
    • 2001
  • 본 연구에서는 평균지체시간을 최소화하는 변동주기 (Cycle fee) 기반의 동적 신호시간 결정모형을 유전자 알고리즘을 이용하여 개발하였다. 본 모형은 실시간으로 변화하는 각 접근로의 차량 도착분포를 토대로 이동류별 지체시간을 산정하고, 교차로의 지체시간을 최소화하는 신호주기의 길이와 이동류별 녹색시간을 산출한다. 개발모형은 4개 교차로로 구성된 간선도로를 대상으로 적용하였으며, 교차로 교통상황의 변화에 따라 신호주기별로 변동하는 신호주기의 길이, 이동류별 녹색시간 그리고 교차로간 변동 연동값을 각각 산출하였다. 모형의 적용결과 산출된 변동 신호주기와 이동류별 녹색시간은 비포화상태와 포화상태 모두 TRANSYT-7F나 PASSER-II에 의하여 산출된 정주기식 신호시간보다 대기차량수, 통과교통량, 그리고 지체시간에서 있어서 더 좋은 결과를 나타내었다. 또한 본 모형은 기존모형과는 달리 연동값을 고정 값으로 설정하지 않고 각 주기가 종료되는 시점마다 교차로 지체시간을 최소화하는 주기 및 이동류별 녹색시간을 산정하므로 연동값도 신호주기별로 변동하였다. 시공도 분석결과, 본 모형에서는 모형의 결과를 산출되는 변동 연동값을 통하여 주방향 이동류의 연동효과를 나타내었다.

  • PDF