• 제목/요약/키워드: Cycle Efficiency

검색결과 1,922건 처리시간 0.039초

EUTECTIC(LiCl-KCl) WASTE SALT TREATMENT BY SEQUENCIAL SEPARATION PROCESS

  • Cho, Yung-Zun;Lee, Tae-Kyo;Choi, Jung-Hun;Eun, Hee-Chul;Park, Hwan-Seo;Park, Geun-Il
    • Nuclear Engineering and Technology
    • /
    • 제45권5호
    • /
    • pp.675-682
    • /
    • 2013
  • The sequential separation process, composed of an oxygen sparging process for separating lanthanides and a zone freezing process for separating Group I and II fission products, was evaluated and tested with a surrogate eutectic waste salt generated from pyroprocessing of used metal nuclear fuel. During the oxygen sparging process, the used lanthanide chlorides (Y, Ce, Pr and Nd) were converted into their sat-insoluble precipitates, over 99.5% at $800^{\circ}C$; however, Group I (Cs) and II (Sr) chlorides were not converted but remained within the eutectic salt bed. In the next process, zone freezing, both precipitation of lanthanide precipitates and concentration of Group I/II elements were preformed. The separation efficiency of Cs and Sr increased with a decrease in the crucible moving speed, and there was little effect of crucible moving speed on the separation efficiency of Cs and Sr in the range of a 3.7 - 4.8 mm/hr. When assuming a 60% eutectic salt reuse rate, over 90% separation efficiency of Cs and Sr is possible, but when increasing the eutectic salt reuse rate to 80%, a separation efficiency of about 82 - 86 % for Cs and Sr was estimated.

직렬형 하이브리드 자동차에서의 폐열 회수에 대한 연구 (Study on the Heat Recovery System in Series Hybrid Electric Vehicle)

  • 정대봉;용진우;김민재;김형준;민경덕
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.95-95
    • /
    • 2010
  • In recent, there are tremendous requirements to improve the fuel economy of vehicle. For satisfaction of requirements, Hybrid Electric Vehicle or other technologies are suggested and implemented. However, it should be noted that almost 35% energy loss is occurred in the shape of exhaust gas as ever. For increase the efficiency of vehicle, it is certain that the exhaust gas energy should be recover, and generate energy. In previous studies, the technologies such as turbo-compound, thermoelectric and rankine cycle are suggested to recover the exhaust heat energy in vehicle. But, they focus on the conventional vehicle or parallel Hybrid Electric Vehicle. Series Hybrid Electric Vehicle has advantage that the engine and drive shaft are de-coupled. It means that the engine can be operated in high efficiency area regardless with vehicle states. Therefore, if rankine cycle is applied to series hybrid electric vehicle, operating condition of that becomes almost steady. So, in this study, theoretical analysis on the efficiency of rankine cycle applied to series hybrid electric city bus is carried and the energy recovered from exhaust gas during vehicle drive cycle is calculated.

  • PDF

An evaluation of power conversion systems for land-based nuclear microreactors: Can aeroderivative engines facilitate near-term deployment?

  • Guillen, D.P.;McDaniel, P.J.
    • Nuclear Engineering and Technology
    • /
    • 제54권4호
    • /
    • pp.1482-1494
    • /
    • 2022
  • Power conversion cycles (Subcritical Steam, Supercritical Steam, Open Air Brayton, Recuperated Air Brayton, Combined Cycle, Closed Brayton Supercritical CO2 (sCO2), and Stirling) are evaluated for land-based nuclear microreactors based on technical maturity, system efficiency, size, cost and maintainability, safety implications, and siting considerations. Based upon these criteria, Air Brayton systems were selected for further evaluation. A brief history of the development and applications of Brayton power systems is given, followed by a description of how these thermal-to-electrical energy conversion systems might be integrated with a nuclear microreactor. Modeling is performed for optimized cycles operating at 3 MW(e) with turbine inlet temperatures of 500 ℃, 650 ℃ and 850 ℃, corresponding to: a) sodium fast, b) molten salt or heat pipe, and c) helium or sodium thermal reactors, coupled with three types of Brayton power conversion units (PCUs): 1) simple open-cycle gas turbine, 2) recuperated open-cycle gas turbine, and 3) recuperated and intercooled open-cycle gas turbine. Aeroderivative turboshaft engines employing the simple Brayton cycle and two industrial gas turbine engines employing recuperated air Brayton cycles are also analyzed. These engines offer mature technology that can facilitate near-term deployment with a modest improvement in efficiency.

냉각공기 예냉각과 연료예열에 의한 복합발전 시스템의 성능변화 (Performance Variation of a Combined Cycle Power Plant by Coolant Pre-cooling and Fuel Pre-heating)

  • 권익환;강도원;김동섭;김재환
    • 한국유체기계학회 논문집
    • /
    • 제15권3호
    • /
    • pp.57-63
    • /
    • 2012
  • Effects of coolant pre-cooling and fuel pre-heating on the performance of a combined cycle using a F-class gas turbine were investigated. Coolant pre-cooling results in an increase of power output but a decrease in efficiency. Performance variation due to the fuel pre-heating depends on the location of the heat source for the pre-heating in the bottoming cycle (heat recovery steam generator). It was demonstrated that a careful selection of the heat source location would enhance efficiency with a minimal power penalty. The effect of combining the coolant pre-cooling and fuel pre-heating was also investigated. It was found that a favorable combination would yield power augmentation, while efficiency remains close to the reference value.

LIVC 적용 밀러사이클 스파크점화기관의 유동특성 연구 (A Study on Flow Characteristics of Spark-Ignited Engine with Variable Intake Valve Closing Timing for Miller Cycle)

  • 정진호;강선제;김진수;정석철;이진욱
    • 한국분무공학회지
    • /
    • 제21권1호
    • /
    • pp.7-12
    • /
    • 2016
  • In this study, to research in-cylinder flow characteristics of spark-ignited engine with intake valve closing timing change for Miller cycle. 3D simulation study were used 6 different intake valve profile with $CAD10^{\circ}$ gap for retard intake valve closing timing. Comparison of In-cylinder flow pattern characteristic were accompanied between Base and LIVC. And the efficiency of volume and the work of compression were analyzed with simulation study. When intake valve closing angle was retarded in $CAD50^{\circ}$, the pressure in cylinder was decreased about 12~13 bar and volume efficiency was reduced about 16%. The efficiency of volume and the work of compression were reduced on LIVC.

공기사이클 냉동시스템의 성능해석 (Performance Analysis of an Air-Cycle Refrigeration System)

  • 원성필
    • 설비공학논문집
    • /
    • 제24권9호
    • /
    • pp.671-678
    • /
    • 2012
  • The objective of this study is to analyze theoretically the performance of an open air-cycle refrigeration system in which environmental concerns increase. The pressure ratio of the external compressor and efficiencies of the components that compose of the system are selected as important parameters. As the pressure ratio of the external compressor increases, the pressure ratio of the ACM compressor is determined high, the refrigerating temperature and capacity increase, the COP decreases, and the total entropy production rate increases. The effect of heat exchanger effectiveness and turbine efficiency on the performance are greater than that of the ACM compressor efficiency. Also the performance of the air-cycle refrigeration system with two heat exchangers has been enhanced like high COP and low total entropy production rate, compared to the system with one heat exchanger.

Duty Cycle Research for Energy Consumption Efficiency under the IoT Wireless Environment

  • Woo, Eun-Ju;Moon, Yu-Sung;Choi, Ung-Se;Kim, Jung-Won
    • 전기전자학회논문지
    • /
    • 제22권4호
    • /
    • pp.1210-1213
    • /
    • 2018
  • In this paper, we propose a method to reduce the amount of current through the Timing Control of the duty cycle and the Report Attribute Control at the MAC Layer in consideration of the Sleep Mode under the IoT wireless environment. The use of a duty cycle is an effective way to reduce energy consumption on wireless sensor networks where the node is placed in sleep mode periodically. In particular, we studied how to control power efficiency through duty rate in Short Transition Time and ACK Time processing while satisfying radio channel limitation criterion. When comparing before and after the improvement considering the delay time constraint, we validated the correlation of the electrical current reduction.

Solar tower combined cycle plant with thermal storage: energy and exergy analyses

  • Mukhopadhyay, Soumitra;Ghosh, Sudip
    • Advances in Energy Research
    • /
    • 제4권1호
    • /
    • pp.29-45
    • /
    • 2016
  • There has been a growing interest in the recent time for the development of solar power tower plants, which are mainly used for utility scale power generation. Combined heat and power (CHP) is an efficient and clean approach to generate electric power and useful thermal energy from a single heat source. The waste heat from the topping Brayton cycle is utilized in the bottoming HRSG cycle for driving steam turbine and also to produce process steam so that efficiency of the cycle is increased. A thermal storage system is likely to add greater reliability to such plants, providing power even during non-peak sunshine hours. This paper presents a conceptual configuration of a solar power tower combined heat and power plant with a topping air Brayton cycle. A simple downstream Rankine cycle with a heat recovery steam generator (HRSG) and a process heater have been considered for integration with the solar Brayton cycle. The conventional GT combustion chamber is replaced with a solar receiver. The combined cycle has been analyzed using energy as well as exergy methods for a range of pressure ratio across the GT block. From the thermodynamic analysis, it is found that such an integrated system would give a maximum total power (2.37 MW) at a much lower pressure ratio (5) with an overall efficiency exceeding 27%. The solar receiver and heliostats are the main components responsible for exergy destruction. However, exergetic performance of the components is found to improve at higher pressure ratio of the GT block.

Optimization of double cycling in container ports

  • Song, Jang-Ho;Kwak, Kyu-Seok
    • 한국항해항만학회지
    • /
    • 제33권2호
    • /
    • pp.127-134
    • /
    • 2009
  • If the research on double cycle is revitalized, crane productivity will be rapidly improved bemuse double cycle is an operational technique that can maximize equipments efficiency (Quay crane, RMG/RTG, Yard tractor). Unfortunately, it is very difficult for terminal operators to find out the starting point of double cycle bemuse the loading & unloading pattern and conditions are various. Therefore, terminal operators are apt to fail to find out the optimal starting point of double cycle to maximize its frequency. Experiencing the same mistakes in the process we made efforts to find out the optimal starting point, finally we found out the formula for it. And we verified its precision is perfect through a lot of testing. This paper on double cycling focused on making the formula to find out optimal starting point of double cycle to maximize its frequency. And it can be applied to various ships' stowages in common.

Duty Cycle 기반의 WSN MAC을 위한 트래픽 환경에 따른 가변 Wakeup Period 기법 제안 (A Study of Variable Wakeup Period for Duty Cycled MAC protocol in WSN)

  • 이재호;엄두섭
    • 전자공학회논문지
    • /
    • 제49권12호
    • /
    • pp.45-55
    • /
    • 2012
  • 센서 네트워크는 센서가 설치된 지역에서 감지된 데이터를 무선으로 전달하는 기술로서, 기존 방식과 달리 에너지 효율이 매우 중요한 성능요소이다. 이러한 특성에 따라 많은 WSN MAC 프로토콜에서는 Wakeup과 Sleep을 반복하여 수행하는 Duty Cycle 기법을 활용하고 있지만, 고정적인 Wakeup 구간의 설정에 따라 획일화된 에너지 성능과 수신 성공률로 인하여 성능이 제한적이다. 본 논문에서는 이러한 Duty Cycle 기반의 MAC 프로토콜을 개선하기 위하여, 채널 환경에 따라 동적으로 Wakeup 구간을 가변화시키는 기법을 제안한다. 제안하는 방식은 트래픽이 높은 환경에서 Wakeup 구간을 증가시켜 수신 성공률을 높이고, 트래픽이 낮은 환경에서 Wakeup 구간을 줄여 에너지 성능을 향상시켰다. 또한 본 논문에서는 제안하는 방식의 성능에 대한 효율적인 평가를 위하여 기존 동기식 및 비동기식 MAC의 결과와 제안방식을 적용한 MAC의 결과를 비교하고 이를 분석하였다.