• Title/Summary/Keyword: CyberKnife Radiosurgery

Search Result 29, Processing Time 0.02 seconds

Clinical Outcomes of Intracranial Nonvestibular Schwannomas Treated with Linac-Based Stereotactic Radiosurgery and Radiotherapy

  • Puataweepong, Putipun;Dhanachai, Mantana;Hansasuta, Ake;Saetia, Kriangsak;Dangprasert, Somjai;Sitathanee, Chomporn;Yongvithisatid, Pornpan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3271-3276
    • /
    • 2016
  • Background: Intracranial nonvestibular schwannomas arising from various cranial nerves excluding CN VIII are uncommon. Recently, stereotactic radiosurgery (SRS) and fractionated stereotactic radiotherapy (SRT) have been widely reported as effective treatment modalities for nonvestibular schwannomas. The purpose of this study was to study the long term clinical outcome for nonvestibular schwannomas treated with both X-Knife and CyberKnife (CK) radiosurgery at one institution. Materials and Methods: From 2004 to 2013, fifty-two nonvestibular schwannoma patients were included in this study, 33 patients (63%) were treated with CK, and 19 (37%) were treated with X-Knife. The majority of the tumors were jugular foramen schwannomas (38%) and trigeminal schwannomas (27%). HSRT was given for 45 patients (86%), whereas CSRT was for 6 (12%) and SRS for 1 (2%). Results: The median pretreatment volume was $9.4cm^3$ (range, $0.57-52cm^3$). With the median follow up time of 36 months (range, 3-135), the 3 and 5 year progression free survival was 94 % and 88%, respectively. Tumor size was decreased in 13 (25%), stable in 29 (56%), and increased in 10 (19%). Among the latter, 3 (30%) required additional treatment because of neurologic deterioration. No patient was found to develop any new cranial nerve deficit after SRS/SRT. Conclusions: These data confirmed that SRS/SRT provide high tumor control rates with low complications. Large volume tumors and cystic expansion after radiation should be carefully followed up with neurological examination and MRI, because it may frequently cause neurological deterioration requiring further surgery.

Accuracy Evaluation of CyberKnife $Synchrony^{TM}$ Respiratory Tracking System Using Phantom (Phantom을 이용한 사이버나이프 $Synchrony^{TM}$ 호흡 추적장치의 정확성 평가)

  • Kim, Gha-Jung;Bae, Seok-Hwan;Lim, Chang-Seon;Kim, Chong-Yeal
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.3
    • /
    • pp.137-143
    • /
    • 2009
  • This study was conducted to evaluate the accuracy of CyberKnife $Synchrony^{TM}$ respiratory tracking system which was applied to Stereotactic Radiosurgery (SRS) for moving tumors in chest and abdomen with breathing motion. For accurate evaluation, gold fiducial marks were implanted into a moving phantom. The moving phantom was a cube imbedding an acryl ball as a target. The acryl ball was prescribed to 20 Gy at 70% of isodose curve in a virtual treatment and radiochromic films were inserted into the acryl ball for dose verification and tracking accuracy evaluation. The evaluation of position tracking consists of two parts: fiducial mark tracking in a stationary phantom and $Synchrony^{TM}$ respiratory tracking in a moving phantom. Each measurement was done in three directions and was repeated to 5 times. Range of position error was 0.1957 mm to 0.6520 mm in the stationary phantom and 0.4405 mm to 0.7665 mm in the moving phantom. Average position error was 0.3926 mm and 0.5673 mm in the stationary phantom and the moving phantom respectively. This study evaluates the accuracy of CyberKnife $Synchrony^{TM}$ Respiratory tracking system, and confirms the usefulness when it's used for Stereotactic Radiosurgery of body organs.

Verification of X-sight Lung Tracking System in the CyberKnife (사이버나이프에서 폐종양 추적 시스템의 정확도 분석)

  • Huh, Hyun-Do;Choi, Sang-Hyoun;Kim, Woo-Chul;Kim, Hun-Jeong;Kim, Seong-Hoon;Cho, Sam-Ju;Min, Chul-Ki;Cho, Kwang-Hwan;Lee, Sang-Hoon;Choi, Jin-Ho;Lim, Sang-Wook;Shin, Dong-Oh
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.174-179
    • /
    • 2009
  • To track moving tumor in real time, CyberKnife system imports a technique of the synchrony respiratory tracking system. The fiducial marker which are detectable in X-ray images were demand in CyberKnife Robotic radiosurgery system. It issued as reference markers to locate and track tumor location during patient alignment and treatment delivery. Fiducial marker implantation is an invasive surgical operation that carries a relatively high risk of pneumothorax. Most recently, it was developed a direct lung tumor registration method that does not require the use of fiducials. The purpose of this study is to measure the accuracy of target applying X-sight lung tracking using the Gafchromic film in dynamic moving thorax phantom. The X-sight Lung Tracking quality assurance motion phantom simulates simple respiratory motion of a lung tumor and provides Gafchromic dosimetry film-based test capability at locations inside the phantom corresponding to a typical lung tumor. The total average error for the X-sight Lung Tracking System with a moving target was $0.85{\pm}0.22$ mm. The results were considered reliable and applicable for lung tumor treatment in CyberKnife radiosurgery system. Clinically, breathing patterns of patients may vary during radiation therapy. Therefore, additional studies with a set real patient data are necessary to evaluate the target accuracy for the X-sight Lung Tracking system.

  • PDF

Evaluation on the Accuracy of Targeting Error Correction Through the Application of Target Locating System in Robotic CyberKnife (로봇 사이버나이프에서 위치인식시스템을 이용한 Targeting Error값 보정의 정확성 평가)

  • Jeong, Young-Joon;Jung, Jae-Hong;Lim, Kwang-Chae;Cho, Eun-Ju
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Purpose: The purpose is to evaluate the accuracy of correcting the targeting error through the Target Location System (TLS) for the location change error of the reference point which arises from the movement or motion of patient during the treatment using the CyberKnife. Materials and Methods: In this test, Gafchromic MD-55 film was inserted into the head and neck phantom to analyze the accuracy of the targeting, and then the 6 MV X-ray of CyberKnife (CyberKnife Robotic Radiosurgery System G4, Accuray, US) was irradiated. End to End (E2E) program was used to analyze the accuracy of targeting, which is provided by Accuray Corporation. To compute the error of the targeting, the test was carried out with the films that were irradiated 12 times by maintaining the distance within the rage of $0{\pm}0.2\;mm$ toward x, y, z from the reference point and maintaining the angle within the rage of $0{\pm}0.2^{\circ}$ toward roll, pitch, yaw, and then with the films which were irradiated 6 times by applying intentional movement. And the correlation in the average value of the reference film and the test film were analyzed through independent samples t-test. In addition, the consistency of dose distribution through gamma-index method (dose difference: 3%) was quantified, compared, and analyzed by varying the distance to agreement (DTA) to 1 mm, 1.5 mm, 2 mm, respectively. Results: E2E test result indicated that the average error of the reference film was 0.405 mm and the standard deviation was 0.069 mm. The average error of the test film was 0.413 mm with the standard deviation of 0.121 mm. The result of independent sampling t-test for both averages showed that the significant probability was P=0.836 (confidence level: 95%). Besides, by comparing the consistency of dose distribution of DTA through 1 mm, 1.5 mm, 2 mm, it was found that the average dose distribution of axial film was 95.04%, 97.56%, 98.13%, respectively in 3,314 locations of the reference film, consistent with the average dose distribution of sagittal film that was 95.47%, 97.68%, 98.47%, respectively. By comparing with the test film, it was found that the average dose distribution of axial film was 96.38%, 97.57%, 98.04%, respectively, at 3,323 locations, consistent with the average dose distribution of sagittal film which was 95.50%, 97.87%, 98.36%, respectively. Conclusion: Robotic CyberKnife traces and complements in real time the error in the location change of the reference point caused by the motion or movement of patient during the treatment and provides the accuracy with the consistency of over 95% dose distribution and the targeting error below 1 mm.

  • PDF

An Image-guided Radiosurgery for the Treatment of Metastatic Bone Tumors using the CyberKnife Robotic System

  • Cho, Chul-Koo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.13 no.1
    • /
    • pp.14-21
    • /
    • 2007
  • Bone is a common site for metastatic spread from many kinds of malignancies. The morbidity associated with this metastatic spread can be significant, including severe pain. When it comes to spinal metastasis, occupying nearly 40% of skeletal metastases, the risks of complications, such as vertebral body collapse, nerve root impingement, or spinal cord compression, are also significant. Because of the necessity of preserving the integrity of the spinal column and the proximity of critical structures, surgical treatment has limitations when durable local control is desired. Radiotherapy, therefore, is often used as an adjunct treatment or as a sole treatment. A considerable limitation of standard radiotherapy is the reported recurrence rate or ineffective palliation of pain, either clinically or symptomatically. This may be due to limited radiation doses to tumor itself because of the proximity of critical structures. CyberKnife is an image-guided robotic radiosurgical system. The image guidance system includes a kilovoltage X-ray imaging source and amorphous silica detectors. The radiation delivery device is a mobile X-band linear accelerator (6 MV) mounted on a robotic arm. Highly conformal fields and hypofractionated radiotherapy schedules are increasingly being used as a means to achieve biologic dose escalation for body tumors. Therefore, we can give much higher doses to the targeted tumor volume with minimizing doses to the surrounding critical structures, resulting in more effective local control and less severe side effects, compared to conventional fractionated radiotherapy. A description of this technology and a review of clinical applications to bone metastases are detailed herein.

  • PDF

Clinical outcome of fiducial-less CyberKnife radiosurgery for stage I non-small cell lung cancer

  • Jung, In-Hye;Song, Si Yeol;Jung, Jinhong;Cho, Byungchul;Kwak, Jungwon;Je, Hyoung Uk;Choi, Wonsik;Jung, Nuri Hyun;Kim, Su Ssan;Choi, Eun Kyung
    • Radiation Oncology Journal
    • /
    • v.33 no.2
    • /
    • pp.89-97
    • /
    • 2015
  • Purpose: To evaluate the treatment results in early stage non-small cell lung cancer patients who have undergone fiducial-less CyberKnife radiosurgery (CKRS). Materials and Methods: From June 2011 to November 2013, 58 patients underwent CKRS at Asan Medical Center for stage I lung cancer. After excluding 14 patients, we retrospectively reviewed the records of the remaining 44 patients. All analyses were performed using SPSS ver. 21. Results: The median age at diagnosis was 75 years. Most patients had inoperable primary lung cancer with a poor pulmonary function test with comorbidity or old age. The clinical stage was IA in 30 patients (68.2%), IB in 14 (31.8%). The mean tumor size was 2.6 cm (range, 1.2 to 4.8 cm), and the tumor was smaller than 2 cm in 12 patients (27.3%). The radiation dose given was 48-60 Gy in 3-4 fractions. In a median follow-up of 23.1 months, local recurrence occurred in three patients (2-year local recurrence-free survival rate, 90.4%) and distant metastasis occurred in 13 patients. All patients tolerated the radiosurgery well, only two patients developing grade 3 dyspnea. The most common complications were radiation-induced fibrosis and pneumonitis. Eight patients died due to cancer progression. Conclusion: The results showed that fiducial-less CKRS shows comparable local tumor control and survival rates to those of LINAC-based SABR or CKRS with a fiducial marker. Thus, fiducial-less CKRS using Xsight lung tracking system can be effectively and safely performed for patients with medically inoperable stage I non-small cell lung cancer without any risk of procedure-related complication.

A New Tool to Predict Survival after Radiosurgery Alone for Newly Diagnosed Cerebral Metastases

  • Rades, Dirk;Huttenlocher, Stefan;Dziggel, Liesa;Blanck, Oliver;Hornung, Dagmar;Mai, Khoa Trong;Ngo, Trang Thuy;Pham, Thai Van;Schild, Steven
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.7
    • /
    • pp.2967-2970
    • /
    • 2015
  • Many patients with few cerebral metastases receive radiosurgery alone. The goal of this study was to create a tool to estimate the survival of such patients. To identify characteristics associated with survival, nine variables including radiosurgery dose, age, gender, Eastern cooperative oncology group performance score (ECOG-PS), primary tumor type, number/size of cerebral metastases, location of cerebral metastases, extra-cerebral metastases and time between cancer diagnosis and radiosurgery were analyzed in 214 patients. On multivariate analysis, age (p=0.03), ECOG-PS (p=0.02) and extra-cerebral metastases (p<0.01) had significant impacts on survival. Scoring points for each patient were obtained from 12-month survival rates (in %) related to the significant variables divided by 10. Addition of the scoring points of the three variables resulted in a patient's total predictive score. Two groups were designed, A (10-14 points) and B (16-17 points). Twelve-month survival rates were 33% and 77%, respectively (p<0.001). Median survival times were 8 and 20 months, respectively. Because most patients of group A died from extra-cerebral disease and/or new cerebral lesions, early systemic treatment and additional WBI should be considered. As cause of death in group B was mostly new cerebral metastases, additional WBI appears even more important for this group.

Differences in Target Volume Delineation Using Typical Radiosurgery Planning System (각각의 방사선수술 치료계획시스템에 따른 동일 병변의 체적 차이 비교)

  • Han, Su Chul;Lee, Dong Joon
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.265-270
    • /
    • 2013
  • Correct target volume delineation is an important part of radiosurgery treatment planning process. We designed head phantom and performed target delineation to evaluate the volume differences due to radiosurgery treatment planning systems and image acquisition system, CT/MR. Delineated mean target volume from CT scan images was $2.23{\pm}0.08cm^3$ on BrainSCAN (NOVALS), $2.13{\pm}0.07cm^3$ on Leksell gamma plan (Gamma Knife) and $2.24{\pm}0.10cm^3$ on Multi plan (Cyber Knife). For MR images, $2.08{\pm}0.06cm^3$ on BrainSCAN, $1.94{\pm}0.05cm^3$ on Leksell gamma plan and $2.15{\pm}0.06cm^3$ on Multi plan. As a result, Differences of delineated mean target volume due to radiotherapy planning system was 3% to 6%. And overall mean target volume from CT scan images was 6.36% larger than those of MR scan images.

An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration (예측 불가능한 호흡 변화에 따른 사이버나이프 종양 추적 방사선 치료의 정확도 분석)

  • Seo, jung min;Lee, chang yeol;Huh, hyun do;Kim, wan sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.157-166
    • /
    • 2015
  • Purpose : Cyber-Knife tumor tracking system, based on the correlation relationship between the position of a tumor which moves in response to the real time respiratory cycle signal and respiration was obtained by the LED marker attached to the outside of the patient, the location of the tumor to predict in advance, the movement of the tumor in synchronization with the therapeutic device to track real-time tumor, is a system for treating. The purpose of this study, in the cyber knife tumor tracking radiation therapy, trying to evaluate the accuracy of tumor tracking radiation therapy system due to the change in the form of unpredictable sudden breathing due to cough and sleep. Materials and Methods : Breathing Log files that were used in the study, based on the Respiratory gating radiotherapy and Cyber-knife tracking radiosurgery breathing Log files of patients who received herein, measured using the Log files in the form of a Sinusoidal pattern and Sudden change pattern. it has been reconstituted as possible. Enter the reconstructed respiratory Log file cyber knife dynamic chest Phantom, so that it is possible to implement a motion due to respiration, add manufacturing the driving apparatus of the existing dynamic chest Phantom, Phantom the form of respiration we have developed a program that can be applied to. Movement of the phantom inside the target (Ball cube target) was driven by the displacement of three sizes of according to the size of the respiratory vertical (Superior-Inferior) direction to the 5 mm, 10 mm, 20 mm. Insert crosses two EBT3 films in phantom inside the target in response to changes in the target movement, the End-to-End (E2E) test provided in Cyber-Knife manufacturer depending on the form of the breathing five times each. It was determined by carrying. Accuracy of tumor tracking system is indicated by the target error by analyzing the inserted film, additional E2E test is analyzed by measuring the correlation error while being advanced. Results : If the target error is a sine curve breathing form, the size of the target of the movement is in response to the 5 mm, 10 mm, 20 mm, respectively, of the average $1.14{\pm}0.13mm$, $1.05{\pm}0.20mm$, with $2.37{\pm}0.17mm$, suddenly for it is variations in breathing, respective average $1.87{\pm}0.19mm$, $2.15{\pm}0.21mm$, and analyzed with $2.44{\pm}0.26mm$. If the correlation error can be defined by the length of the displacement vector in the target track is a sinusoidal breathing mode, the size of the target of the movement in response to 5 mm, 10 mm, 20 mm, respective average $0.84{\pm}0.01mm$, $0.70{\pm}0.13mm$, with $1.63{\pm}0.10mm$, if it is a variant of sudden breathing respective average $0.97{\pm}0.06mm$, $1.44{\pm}0.11mm$, and analyzed with $1.98{\pm}0.10mm$. The larger the correlation error values in both the both the respiratory form, the target error value is large. If the motion size of the target of the sine curve breathing form is greater than or equal to 20 mm, was measured at 1.5 mm or more is a recommendation value of both cyber knife manufacturer of both error value. Conclusion : There is a tendency that the correlation error value between about target error value magnitude of the target motion is large is increased, the error value becomes large in variation of rapid respiration than breathing the form of a sine curve. The more the shape of the breathing large movements regular shape of sine curves target accuracy of the tumor tracking system can be judged to be reduced. Using the algorithm of Cyber-Knife tumor tracking system, when there is a change in the sudden unpredictable respiratory due patient coughing during treatment enforcement is to stop the treatment, it is assumed to carry out the internal target validation process again, it is necessary to readjust the form of respiration. Patients under treatment is determined to be able to improve the treatment of accuracy to induce the observed form of regular breathing and put like to see the goggles monitor capable of the respiratory form of the person.

  • PDF

A case report of a patient with squamous cell carcinoma of the face irradiated using a stereotactic technique

  • Pontoriero, Antonio;Iati, Giuseppe;Pergolizzi, Stefano
    • Radiation Oncology Journal
    • /
    • v.33 no.3
    • /
    • pp.261-264
    • /
    • 2015
  • External beam radiotherapy can be used to treat cutaneous squamous cell carcinomas (SCC). Acute skin toxicity is the most common adverse event. In this case study we report on an elderly patient with nasal root cutaneous SCC treated with stereotactic technique using a dedicated linear accelerator (CyberKnife system). Grade 3 skin toxicity was observed but it was resolved after 6 weeks. The use of stereotactic radiotherapy permitted a clinical remission of SCC with good cosmetic results.