• 제목/요약/키워드: Cut-Set

Search Result 431, Processing Time 0.024 seconds

Knee extension test for assessing hamstring flexibility (넓적다리뒤근육의 유연성 측정을 위한 무릎폄 검사)

  • Wootaek Lim
    • Journal of Korean Physical Therapy Science
    • /
    • v.30 no.1
    • /
    • pp.31-40
    • /
    • 2023
  • Hamstring flexibility is an important factor that affects muscle performance of the lower extremities and is closely associated with sports injuries. Therefore, evaluation of flexibility is important in clinical practice. Results of evaluation are determined by types of tests and cut-off values used; therefore, accurate and detailed understanding of these is necessary before examination. Although the straight leg raise and sit and reach tests are used to evaluate hamstring extensibility, structures including the nerves, fascia, and other muscles can significantly confound the results of these tests. The knee extension test is performed at 90° of hip flexion to minimize the posterior pelvic tilt that occurs during the straight leg test. The knee extension test is most recommended for selective evaluation of hamstring flexibility. The knee extension test is classified into active and passive tests. The cut-off value is usually set at 20° for the active and at 10° for the passive knee extension test. Although a strong association is observed between the two tests, the active knee extension test is preferred in clinical practice because it can be performed by a single examiner, which serves as an advantage. Age, sex, and warm-up exercise tend to affect flexibility; therefore, results should be interpreted with caution. Detailed understanding of each flexibility test is important for reliable evaluation.

Analysis on Characteristics of Behavior of Thermal Flow According to Operation Conditions of Small-sized Shell and Tube-type Heat Exchanger (소형 쉘앤튜브형 열교환기의 운전 조건에 따른 열유동 거동 특성 해석)

  • Young-Joon Yang
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_2
    • /
    • pp.1109-1115
    • /
    • 2023
  • The shell and tube-type heat exchanger was the most utilized in industrial field because of its simple structure and wide operation conditions and so on. This study was performed to investigate the characteristics of behavior of thermal flow according to operation condition of small-sized shell and tube-type heat exchanger. The operation conditions, here, were set up to flow rate of hot air with temperature of 100℃, number of baffle and cut rate of baffle(BCR) using numerical analysis. As the results, both mean relative pressure and relative pressure drop was increased with quadratic curve in case of less than BCR 25%, however, decreased linearly in case of more than BCR 25%. The collision with first baffle by flow velocity and temperature, of hot air, respectively, was depended on BCR. Further it showed that the behaviors between flow velocity and temperature were almost similar.

Korean Groal Potential Habitat Suitability Model at Soraksan National Park Using Fuzzy Set and Multi-Criteria Evaluation (설악산국립공원내 산양(Nemorhaedus Caudatus Raddeanus)의 잠재 서식지 적합성 모형; 다기준평가기법(MCE)과 퍼지집합(Fuzzy Set)의 도입을 통하여)

  • Choi Tae-Young;Park Chong-Hwa
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.32 no.4
    • /
    • pp.28-38
    • /
    • 2004
  • Korean goral (Nemorhaedus caudatus raddeanus) is one of the endangered species in Korea, and the rugged terrain of the Soraksan National Park (373㎢) is a critical habitat for the species. But the goral population is threatened by habitat fragmentation caused by roads and hiking trails. The objective of this study was to develop a potential habitat suitability model for Korean goral in the park, and the model was based on the concepts of fuzzy set theory and multi-criteria evaluation. The process of the suitability modeling could be divided into three steps. First, data for the modeling was collected by using field work and a literature survey. Collected data included 204 points of GPS data obtained through a goral trace survey and through the number of daily visitors to each hiking trail during the peak season of the park. Second, fuzzy set theory was employed for building a GIS data base related to environmental factors affecting the suitability of the goral habitat. Finally, a multiple-criteria evaluation was performed as the final step towards a goral habitat suitability model. The results of the study were as follows. First, characteristics of suitable habitats were the proximity to rock cliffs, scattered pine (Pinus densiflora) patches, ridges, the elevation of 700∼800m, and the aspect of south and southeast. Second, the habitat suitability model had a high classification accuracy of 93.9% for the analysis site, and 95.7% for the validation site at a cut off value of 0.5. Finally, 11.7% of habitatwith more than 0.5 of habitat suitability index was affected by roads and hiking trails in the park.

Reevaluation of the Neonatal Screening Test for Congenital Hypothyroidism (선천성 갑상선기능저하증에 대한 신생아 선별검사의 재평가)

  • Kang, So Young;Chang, Young Pyo;Yu, Jeesuk
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.4
    • /
    • pp.387-394
    • /
    • 2005
  • Purpose : We performed this study to compare the TSH and free $T_4$ levels according to gestational age and birth weight, and to reevaluate the cut-off values in the neonatal screening test for congenital hypothyroidism. Methods : Total 2,133 neonates(1,749 healthy newborns and 384 sick neonates) were screened in Dankook University Hospital from May 2000 to January 2003. Neonates with abnormal TSH values (higher than $20{\mu}IU/mL$) or abnormal free $T_4$ levels(lower than 1 ng/dL) were recalled to recheck the thyroid function test. At that time, physical examinations and history-taking regarding perinatal problem, medication history, and mother's illness were undertaken. Results : Serum TSH and free $T_4$ values revealed no significant difference according to sex, delivery type, and Apgar score. The free $T_4$ levels showed statistically significant differences, with gestational age or birth weight(P<0.01). The recall rate of neonates due to abnormal screening test was 7.48 percent. Compared with original cut-off values, the recall rate of the new cut-off values setted to TSH higher than $20{\mu}IU/mL$ or free $T_4$ lower than 0.64 ng/dL decreased from 7.48 percent to 4.8 percent in the healthy group. But, it compromised sensitivity when applied to the sick group. Conclusion : In this study, neonatal free $T_4$ levels were significantly different according to birth weight, gestational age, and the presence of compromised condition. Although the recall rate by TSH > $20{\mu}IU/mL$ or free $T_4$ <1 ng/dL was relatively high, it was impossible to set up new cut-off values without compromising sensitivity. We think studies including a larger study population will be required to change the cut-off values.

Monitoring of Cut-Slope Behavior with Consideration of Rock Structure and Failure Mode (개착사면의 구조적 특성과 파괴양상을 고려한 계측 해석)

  • Cho, Tae-Chin;Park, So-Young;Lee, Sang-Bae;Lee, Geun-Ho;Won, Kyung-Sik
    • Tunnel and Underground Space
    • /
    • v.16 no.6 s.65
    • /
    • pp.451-466
    • /
    • 2006
  • Analysis of slope behavior concerning the structural characteristics of field rock mass can be processed by virtue of borehole information of joint orientation and position acquired from DOM drilled core. Anticipated sliding potential of pre-failed rock slope is analyzed and the regional slope instability is investigated by inspecting the hazardous joints and blocks the traces of which is projected on the cut-face. Cross section has been set at the center of rock slope and the traces of both joints and tetrahedral blocks, which potentially can induce the slope failure, are drawn to investigate the failure modes and the triggering mechanism. Automated monitoring system has been established to measure the slope movement and especially, inclinometer has been installed inside DOM borehole to analyze the slope movement by considering the internal rock structure. Algorithms for predicting the slope failure time have been reviewed and the significance of heavy rainfall on the slope behavior has been investigated.

Fiber orientation distribution of reinforced cemented Toyoura sand

  • Safdar, Muhammad;Newson, Tim;Waseem, Muhammad
    • Geomechanics and Engineering
    • /
    • v.30 no.1
    • /
    • pp.67-73
    • /
    • 2022
  • In this study, the fiber orientation distribution (FOD) is investigated using both micro-CT (computerized tomography) and image analysis of physically cut specimens prepared from Polyvinyl Alcohol (PVA) fiber reinforced cemented Toyoura sand. The micro-CT images of the fiber reinforced cemented sand specimens were visualized in horizontal and vertical sections. Scans were obtained using a frame rate of two frames and an exposure time of 500 milliseconds. The number of images was set to optimize and typically resulted in approximately 3000 images. Then, the angles of the fibers for horizontal sections and in vertical section were calculated using the VGStudio MAX software. The number of fibers intersecting horizontal and vertical sections are counted using these images. A similar approach was used for physically cut specimens. The variation of results of fiber orientation between micro-CT scans and visual count were approximately 4-8%. The micro-CT scans were able to precisely investigate the fiber orientation distribution of fibers in these samples. The results show that 85-90% of the PVA fibers are oriented between ±30° of horizontal, and approximately 95% of fibers have an orientation that lies within ±45° of the horizontal plane. Finally, a comparison of experimental results with the generalized fiber orientation distribution function 𝜌(θ) is presented for isotropic and anisotropic distribution in fiber reinforced cemented Toyoura sand specimens. Experimentally, it can be seen that the average ratio of the number of fibers intersecting the finite area on a vertical plane to number of fibers intersecting the finite area on a horizontal plane (NVtot/NHtot) cut through a sample varies from 2.08 to 2.12 (an average ratio of 2.10 is obtained in this study). Based up on the analytical predictions, it can be seen that the average NVtot/NHtot ratio varies from 2.13 to 2.17 for varying n values (an average ratio of 2.15).

Behavior of arch slab in the shallow tunnel constructed perpendicular to slope by semi-cut-and-cover method (편경사지에 굴착한 반개착식 천층터널에서 아치슬래브의 거동)

  • Yang, Jae-Won;Lee, Sang-Duk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.2
    • /
    • pp.157-164
    • /
    • 2010
  • Recently, the number of shallow tunnel construction increases to improve the structural safety and environment-friendliness. In semi-cut-and-cover Method, ground is excavated to the crown arch level and arch slab is set to backfill before the excavation of lower face. In this study, laboratory model tests was performed to clarify the behavior of the arch slab constructed perpendicular to the slope. Results show that Arch slab is affected by perpendicular to the slope and bedrocks. Negative moment at the upper part of the arch slab at hillside and positive moment at the upper part at the other side are generated as perpendicular to the slope increases. Reaction load at the hillside support was larger than that at the other side.

The Effect of Soil Warming on the Greenhouse Heating Load (지중가온이 온실의 난방부하에 미치는 영향)

  • Nam, Sang-Woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.5
    • /
    • pp.51-60
    • /
    • 2006
  • In order to examine the heat transfer characteristic of a soil warming system and effects of soil warming on the greenhouse heating load, control experiments were performed in two greenhouses covered with double polyethylene film. One treated the soil warming with an electric heat wire and the other treated a control. Inside and outside air temperature, soil temperature and heat flux, and heating energy consumption were measured under the set point of heating temperature of $5,\;10,\;15,\;and\;20^{\circ}C$, respectively. Soil temperatures in a soil warming treatment were observed $4.1\;to\;4.9^{\circ}C$ higher than a control. Heating energy consumptions decreased by 14.6 to 30.8% in a soil warming treatment. As the set point of heating temperature became lower, the rate of decrease in the heating energy consumptions increased. The percentage of soil heat flux in total heating load was -49.4 to 24.4% and as the set point of heating temperature became higher, the percentage increased. When the set point of heating temperature was low in a soil warming treatment, the soil heat flux load was minus value and it had an effect on reducing the heating load. Soil heat flux loads showed in proportion to the air temperature difference between the inside and outside of greenhouse but they showed big difference according to the soil warming treatment. So new model for estimation of the soil heat flux load should be introduced. Convective heat transfer coefficients were in proportion to the 1/3 power of temperature difference between the soil surface and the inside air. They were $3.41\;to\;12.42\;W/m^{2}^{\circ}C$ in their temperature difference of $0\;to\;10^{\circ}C$. Radiative heat loss from soil surface in greenhouse was about 66 to 130% of total heating load. To cut the radiation loss by the use of thermal curtains must be able to contribute for the energy saving in greenhouse.

The Analysis of the LCL Set-up Parameters for Satellite Power Distribution (위성전원분배를 위한 LCL 동작 파라미터 설정분석)

  • Lim, Seong-Bin;Jeon, Hyun-Jin;Kim, Kyung-Soo;Kim, Tae-Youn
    • Aerospace Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.56-64
    • /
    • 2011
  • In this paper, the characteristics of LCL set-up parameters for the satellite load distribution are analyzed under the electrical system environment, implemented the LCL circuits and evaluated the performance and its behaviour. Recently, it is implemented the load distribution circuit by latching current limiter(LCL) rather than conventional fuse and relay for the protection of the satellite power system from a fault load. The LCL circuit is composed of the electrical components, not mechanical parts with the fuse and relay. When detected the over current on a fault load, it is activated to maintain the trip-off level for set-up time and then cut-off the load power by the active control. It is more flexible and provided a chance to reuse of the load in case of temporarily event, but the fuse and relay can't be used again after activating due to the physical disconnection. However, for implementation of LCL circuit, it should be carefully considered the behavior of the LCL circuit under the worst electrical system environment and applied it to define the set-up parameters related with over-current inhibition.

On the Definition of Intuitionistic Fuzzy h-ideals of Hemirings

  • Rahman, Saifur;Saikia, Helen Kumari
    • Kyungpook Mathematical Journal
    • /
    • v.53 no.3
    • /
    • pp.435-457
    • /
    • 2013
  • Using the Lukasiewicz 3-valued implication operator, the notion of an (${\alpha},{\beta}$)-intuitionistic fuzzy left (right) $h$-ideal of a hemiring is introduced, where ${\alpha},{\beta}{\in}\{{\in},q,{\in}{\wedge}q,{\in}{\vee}q\}$. We define intuitionistic fuzzy left (right) $h$-ideal with thresholds ($s,t$) of a hemiring R and investigate their various properties. We characterize intuitionistic fuzzy left (right) $h$-ideal with thresholds ($s,t$) and (${\alpha},{\beta}$)-intuitionistic fuzzy left (right) $h$-ideal of a hemiring R by its level sets. We establish that an intuitionistic fuzzy set A of a hemiring R is a (${\in},{\in}$) (or (${\in},{\in}{\vee}q$) or (${\in}{\wedge}q,{\in}$)-intuitionistic fuzzy left (right) $h$-ideal of R if and only if A is an intuitionistic fuzzy left (right) $h$-ideal with thresholds (0, 1) (or (0, 0.5) or (0.5, 1)) of R respectively. It is also shown that A is a (${\in},{\in}$) (or (${\in},{\in}{\vee}q$) or (${\in}{\wedge}q,{\in}$))-intuitionistic fuzzy left (right) $h$-ideal if and only if for any $p{\in}$ (0, 1] (or $p{\in}$ (0, 0.5] or $p{\in}$ (0.5, 1] ), $A_p$ is a fuzzy left (right) $h$-ideal. Finally, we prove that an intuitionistic fuzzy set A of a hemiring R is an intuitionistic fuzzy left (right) $h$-ideal with thresholds ($s,t$) of R if and only if for any $p{\in}(s,t]$, the cut set $A_p$ is a fuzzy left (right) $h$-ideal of R.