The Journal of Korean Society for Radiation Therapy
/
v.7
no.1
/
pp.92-96
/
1995
All patients who will Undergo irraidiation of the oral cavity cancer will need dental before and during Radiotherapy. The extent of the region and the presence of numerous critical normal tissues(mucosa, gingiva, teeth and the alveolar ridge, alveolar bony structure, etc) in the oral cavity area, injury to which could result in serious functional impairment. Therefore I evaluate the Usefulness of custom-made intraoral shielding device before and during Radiotherapy in oral cavity cancer. Materials and Methods(1) : Manufacture process of Custom-made intraoral shielding device Containing Cerroband. A. Acquisition of impression B. Matrix Constitution C. Separation by Separator D. Sprincle on method E. Trimming F. Spacing G. Fill with Cerroband Materials and Methods (2) A. Preannealing B. TLD Set up C. Annealing D. TLD Reading = Results = Therefore dosimetric characteristics in oral cavity by TLD Compared to isodose curve dose distribution Ipsilateral oral mucosa, Contralateral oral mucosa, alveolar ridge, tongue, dose was reduced by intraoral shielding device containning Cerroband technique Compard to isodose plan = Conclusions = The custom-made intra-oral shielding device containing Cerroband was useful in reducing the Contralateral oral mucosa dose and Volume irradiated.
Noise induced hearing loss (NIHS), the well-known occupational disease, is caused by continuous excessive noise. The prevention of NIHS is very important, because it is unrecoverable. There are some kinds of hearing protection device (HPD), and those are effective in preventing NIHS. But workers in noisy environment often resist to wearing them. Because they are ready - made products, so workers feel uncomfortable to wear. Also, they didn't maintain the conversation frequency range, so workers are hard to communicate in wearing them. To prevent hearing loss effectively, it is important that workers keep wearing HPD. Therefore, a HPD is needed to be comfortable to wear and be effective not only in hearing protection but also in preserving communication ability. So we proposed a custom - made hearing protection device in which a small acoustic filter is inserted. We designed several kinds of small acoustic filters and carried out some acoustic experiments for measuring characteristics of filters. We confirmed that acoustic transmission characteristic can be adjusted from experimental results using designed small acoustic filters. And we researched for the actual efficiency of a new developed custom - made hearing protection device using a small size acoustic filter. Also, we found out that workers are more satisfied with the new development than a former protection device from a workers' response.
The mouth guard is a device with elasticity to be installed in the oral cavity. It has a function to reduce the trauma in the oral cavity and to protect the teeth and surrounding tissues from trauma. The purpose of mouth guard is to prevent trauma and concussion. It is mandatory to wear a mouthguard in sports where there is a lot of contact and the possibility of trauma or concussion in the mouth area is high. The mouse guard is divided into a stock type, a mouth formed type, and a custom made type according to the manufacturing method. The custom made type is made on the individual dentition model and has excellent retention because of its excellent fit. Also, the effect of trauma prevention is excellent. It is possible to design and adjust by the dentist and reduce the complaint the athlete has about the mouthguard. In this article, the process of making a dentist-customized mouthguard was described.
Yang Oh Nam;Lee Woo Seok;Hong Tack Kyun;Jo Young Pil;Yun Hwa Ryong;Kim Jung Man
The Journal of Korean Society for Radiation Therapy
/
v.15
no.1
/
pp.61-65
/
2003
I. Purpose Patient immobilization is essential factor for successful radiation therapy and major problem is reproducibility to maintain patient position during total radiation therapy period. Purpose of this study is evaluation for usefulness of the custom made immobilization device for the anteroperitoneal resection patients with rectal cancer II. Materials and Methods The object of this study were patients who underwent anteroperitoneal resection and undergo radiation therapy at present with rectal cancer. We made immobilization device for patient individually and analyzed its set up reproducibility, patient position deviation and errors. III. Results There was $5mm{\sim}10mm$ deviation in patient position without individual immobilization device, but we improved the deviation within few mm limitation with individual immobilization device. IV. Conclusion Custom made immobilization device was very helpful for anteroperitoneal resection patient with rectal cancer. We improved the patient position deviation within few mm limitation, shorten the set up time and we could give the comfort to patients.
Park, Kang-Nam;Lee, Chang Youn;Park, In Young;Kim, Jwa Young;Yang, Byoungeun
Maxillofacial Plastic and Reconstructive Surgery
/
v.37
/
pp.11.1-11.5
/
2015
Rapid palatal expansion(RPE) with the tooth-born appliance is not sufficient to apply to the patients with periodontal problem or insufficient tooth anchorage, and it leads to tipping of the anchorage teeth and increasing teeth mobility and root resorption. To avoid these disadvantages, we present the case using palatal screws and custommade palatal expander. A 23-year-old patient underwent surgically assisted rapid maxillary expansion with the Hyrax expansion using 4 tent screws. The study models were used to measure the pre-/-post surgical width of the anterior and posterior dental arches with a digital sliding caliper. In the result, the custom-made palatal expander with 4 tent screws is suitable for delivering a force to the mid-palatal suture expansion. And it is low cost, small sized and simply applied. The results indicated that maxillary expansion with the custom-made palatal anchorage device is predictable and stable technique without significant complications in patients.
Lee, Seong-Joo;Lim, Ji Young;Lee, Chang-Hyung;Park, Dae-Sung
Physical Therapy Rehabilitation Science
/
v.8
no.4
/
pp.218-224
/
2019
Objective: This reliability study examined the effects of applying varying induced inward pressures using a transducer placed at 0° neutral ankle position (NEU) and 15° ankle dorsiflexion (DF) on tibialis anterior (TA) muscle thickness using a custom-made device with a force indicator during rehabilitative ultrasound imaging. Design: Cross-sectional study. Methods: Twenty-four healthy subjects were recruited in this study. Two examiners measured the muscle thickness of the TA at 0° NEU and 15° DF in 3 conditions of inward pressures (1.0 N, 2.0 N, and 4.0 N) using a custom-made holder. The muscle thickness was measured three times for each of the conditions arranged in random order. For intra- and inter-rater reliability, the intraclass correlation coefficients (ICCs) with 95% confidence intervals, standard error of measurement, minimal detectable change, and coefficient of variation were analyzed. One-way repeated measures analysis of variance was conducted for investigating changes of TA muscle thickness according to the inward pressures of the transducers. Results: The intra-rater reliability of TA muscle thickness measurement was excellent (ICC3,1: 0.92-0.96) for all conditions (at both ankle joint angles per varying inward pressure). Likewise, the inter-rater reliability of TA muscle thickness measurement was excellent (ICC2,1: 0.89-0.97) under same conditions. The mean of TA thickness showed the trend of decreasing significantly with increased inward pressures at all ankle joint angles (p<0.05). Conclusions: Use of this custom-made device with a force indicator is useful to accomplish the high intra- and inter-rater reliability of TA muscle thickness measurement at both ankle joint angles in reducing the measurement error.
Kim, Young-Tak;Park, Ju-Won;Tack, Han-Ho;Lee, Sang-Bae
Journal of the Korean Institute of Intelligent Systems
/
v.14
no.7
/
pp.871-877
/
2004
In this paper, for manufacturing a custom-made shoes, shape of foot acquired three-dimensional measurement device which makes shoe-last data for needing a custom-made shoes is founded on artificial intelligence technique and it shows method restoring to the original shape in optimized state. the developed system for this study is based on PC which uses existing three dimensional measurement method. And it gains shoe-last and data of foot shape going through 8 CCD(Charge Coupled Device) Which equipped top and bottom, right and left sides and 4 lasers which also equipped both sides and upper and lower sides. The acquired data are processed image processing algorithm using artificial intelligence technique. And result of data management is better quality of removing noise than other system not using artificial intelligence technique and it can simplify post-processing. So, this paper is constituted hardware and software system and it used neural network for determining threshold value, when input image on pre-processing step is being stage of image binarization and present that results.
Merve Nur Uygun;Yeong-geol Bae;Yejin Choi;Dae-Sung Park
Physical Therapy Rehabilitation Science
/
v.12
no.3
/
pp.251-258
/
2023
Objective: The practice of breathing exercises involves altering the depth and frequency of respiration. Strengthening respiratory muscles plays a crucial role in maintaining overall health and well-being. The efficiency of the respiratory system affects not only physical activity but also various physiological processes including cardiovascular health, lung function, and cognitive abilities. The study evaluated the reliability of the developed device for inspiratory/expiratory training using pressure sensors and Bluetooth connectivity with a smartphone application. Design: Design & development research Methods: The research methodology involved connecting a custom-made respiratory sensor to an IMT-PEP BIC Breath device. Various pressure conditions were measured, and statistical analyses were performed to assess reliability and consistency. Results showed high Intraclass Coefficient Correlation (ICC) values for both inspiratory and expiratory pressures, indicating strong test-retest reliability. The device was designed for ease of use and wireless monitoring through a smartphone app. Results: This study conducted at expiratory pressure confirmed the proper operation of the IMT/PEP breathing trainer at the specified pressure setting in the product. The pressure sensor demonstrated high test-retest reliability with an ICC value of 0.999 for both expiratory and inspiratory pressure measurements. Conclusions: The developed respiratory training device measured and monitored inspiratory and expiratory pressures, demonstrating its reliability for respiratory training. The system could be utilized to record training frequency and intensity, providing potential benefits for patients requiring respiratory interventions. Further research is needed to assess the full potential of the device in diverse populations and applications.
3D printing technology supporting the specific patient medical services is actively being implemented in dentistry. The purpose of this study is to introduce the legal and institutional considerations to the medical practitioners in dentistry who must observe when they manufacture medical devices using 3D printers, and to provide a ways to activate and enhance their utilization in the domestic approval point of view for medical devices. Through the public data of government agencies and related organizations, the statutory system and compliance matters related to the manufacture of 3D printing medical devices have been examined and reviewed for the government's improvement efforts. Through the study, the government has been actively improving the system and making policy, but the active interest and participation of medical professionals and related workers are continually required to solve the problems which are scattered. 3D printing technology is expected to be more frequently utilized in the field of dentistry in near future. Therefore, it is essential to establish measures to improve the regulation through continuous cooperation with the related ministries with the long-term point of view enhancing smooth entry to the market for the medical devices by taking data from the continued research.
Studying the effects of gamma radiation on the instrumentation and control (I&C) system of a nuclear power plant is critical to the successful and reliable operation of the plant. In the accidental scenario, the adverse environment of ionizing radiation affects the performance of the I&C system and it leads to inaccurate and incomprehensible results. This paper reports the effects of gamma radiation on the AT89C51RD2, a commercial-off-the-shelf 8-bit high-performance flash microcontroller. The microcontroller, selected for the device under test for this study is used in the remote terminal unit for a nuclear power plant. The custom circuits were made to test the microcontroller under different gamma doses using a 60Co gamma source in both ex-situ and in-situ modes. The device was exposed to a maximum dose of 1.5 kGy. Under this hostile environment, the performance of the microcontroller was studied in terms of device current and voltage changes. It was observed that the microcontroller device can operate up to a total absorbed dose of approximately 0.6 kGy without any failure or degradation in its performance.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.