• 제목/요약/키워드: Curved probe

검색결과 16건 처리시간 0.009초

초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구 (A Study on the Reflectivity according to the Material of Biopsy Gun Needle Used in Ultrasound Biopsy)

  • 김훈;임청환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권2호
    • /
    • pp.97-105
    • /
    • 2024
  • The examination needle used in ultrasound biopsy is a medical device used to determine whether there is an abnormality in the tissue. Typically, stainless steel is the standard material used for such needles; however, this study wanted to identify a material that could better enhance sound compared to traditional stainless steel. In this study, six types of needle materials available with the biopsy gun were inserted into pork and ultrasound images according to the curved probe and linear probe were evaluated using ultrasound equipment. The findings revealed significant improvements in ultrasound acoustic enhancement with alternative materials compared to stainless steel (p<0.05). The results regarding the depth of each ultrasound image using the curved probe showed that tungsten and brass had high sound enhancement(p<0.05), while with the linear probe, sound enhancement was high in brass, pla, aluminum, and copper(p<0.05). Due to these results, the previously used stainless needle showed lower ultrasound acoustic enhancement than the five types of materials being compared. Consequently, the outcomes of this study provide valuable insights for the development of new needle technologies aimed at minimizing patient risks and improving diagnostic accuracy.

Strategies for Noncontained Lumbar Disc Herniation by an Endoscopic Approach : Transforaminal Suprapedicular Approach, Semi-Rigid Flexible Curved Probe, and 3-Dimensional Reconstruction CT with Discogram

  • Chae, Ki-Hwan;Ju, Chang-Il;Lee, Seung-Myung;Kim, Byoung-Wook;Kim, Saeng-Youp;Kim, Hyeun-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권4호
    • /
    • pp.312-316
    • /
    • 2009
  • Objective : The purpose of this study was to evaluate the efficacy of a transforaminal suprapedicular approach, semi-rigid flexible curved probe, and 3-dimensional reconstruction computed tomography (3D-CT) with discogram in the endoscopic treatment of non-contained lumbar disc herniations. Methods : The subjects were 153 patients with difficult, non-contained lumbar disc herniations undergoing endoscopic treatment. The types of herniation were as follows : extraforaminal, 17 patients; foraminal, 21 patients; high grade migration, 59 patients; and high canal compromise, 56 patients. To overcome the difficulties in endoscopic treatment, the anatomic structures were analyzed by 3D reconstruction CT and the high grade disc was extracted using a semi-rigid flexible curved probe and a transforaminal suprapedicular approach. Results : The mean follow-up was 18.3 months. The mean visual analogue scale (VAS) of the patients prior to surgery was 9.48, and the mean postoperative VAS was 1.63. According to Macnab's criteria, 145 patients had excellent and good results, and thus satisfactory results were obtained in 94.77% cases. Conclusion : In a posterolateral endoscopic lumbar discectomy, the difficult, non-contained disc is considered to be the most important factor impeding the success of surgery. By applying a semi-rigid flexible curved probe and using a transforaminal suprapedicular approach, good surgical results can be obtained, even in high grade, non-contained disc herniations.

Experimental Study on the Mean Flow Characteristics of Forward-Curved Centrifugal Fans

  • Kwon, Eui-Yong;Cho, Nam-Hyo
    • Journal of Mechanical Science and Technology
    • /
    • 제15권12호
    • /
    • pp.1728-1738
    • /
    • 2001
  • Measurements have been made in an automotive HVAC b1ower for two different centrifugal fans. This work is directed at improving the performance of a conventional forward-curved centrifugal fan for a given small blower casing. Mean velocities and pressure have been measured using a miniature five-hole probe and a pressure scanning unit connected to an online data acquisition system. First, we obtained the fan performance versus flow rates showing a significant attenuation of unstable nature achieved with the new fan rotor in the surging operation range. Second, aerodynamic characterizations were carried out by investigating the velocity and pressure fields in the casing flow passage for different fan operating conditions. The measurements stowed that performance coefficients are strongly influenced by flow characteristics at the throat region. The main flow features ware common in both fans, but improved performance is achieved with tole new fan rotor, particularly in lower flow rate legions. Based on the measured results, design improvements were carried out in an acceptable operation range, which gave considerable insight into what features of flow behavior ware most important.

  • PDF

방사힘 측정법을 이용한 초음파 진단장치용 배열 탐침자의 음향파워 측정시스템 (Acoustic Power Measurement System of Array Probes for Ultrasonic Diagnostic Equipment Using Radiation Force Balance Methods)

  • 윤용현;조문재;김용태;이명호
    • 한국음향학회지
    • /
    • 제29권6호
    • /
    • pp.355-364
    • /
    • 2010
  • 초음파 진단장치의 음향출력 특성은 전기음향 변환 장치인 배열 탐침자의 성능에 크게 영향을 받으며, 생물학적안전 측면에서 매우 중요하다. 본 논문에서는 초음파 진단장치용 배열 탐침자로부터 방사되는 음향파워를 소자별로 측정할 수 있는 자동화 시스템을 구성하였으며, 곡선형 탐침자의 경우 각 소자의 지향성이 측정에 미치는 영향을 확인하고 이를 보정하는 기법을 개발하였다. 선형, 위상형, 곡선형 배열 탐침자를 대상으로 음향파워 측정결과, 본 논문에서 제시하는 측정기법은 배열 탐침자의 음향파워 특성을 평가하는데 적합함을 확인하였다.

멤스 프로브 카드를 위한 깊은 트렌치 안에서 S 모양의 일체형 미세피치 외팔보 프로브 형성공정 개발 (Process Development of Forming of One Body Fine Pitched S-Type Cantilever Probe in Recessed Trench for MEMS Probe Card)

  • 김봉환
    • 대한전자공학회논문지SD
    • /
    • 제48권1호
    • /
    • pp.1-6
    • /
    • 2011
  • 본 논문에서는 미세피치 프로브 카드 제작을 위한 S 모양의 일체형 외팔보 프로브 형성방법에 대하여 기술하였다. 마세 피치 프로브를 위하여 Deep RIE etching을 이용하여 실리콘 트렌치 안에 일체형 프로브 빔과 탑을 형성하는 방법을 사용하였고, 피라미드 팁의 형성을 위하여 KOH 및 TMAH 습식식각을 이용하였으며, 습식식각시 방향성을 가지는 실리콘 웨이퍼에서도 휘어진 형태의 프로브 빔을 형성할 수 있는 건식 식각 및 습식식각 방법을 제시하였다. 따라서 제작된 외팔보 형태의 프로브는 디렘(DRAM), 플레시 메모리 (Flash memory) 용 프로브 카드 제작에 사용될 뿐만 아니라 RF 소자용 프로브 카드, 아이씨 테스트 소켓 (IC test socket)용 프로브 탐침에도 사용 될 것이다.

자동차 에어컨용 전곡형 원심 송풍기의 공력성능 분석 (Experimental Study on the Performance of a Forward-Curved Centrifugal Fan for an Automotive Air-Conditioner)

  • 권의용;조남효
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.122-128
    • /
    • 2000
  • Aerodynamic optimization of an automotive air-conditioning blower is a hard task because of the highly complex flow phenomena related to three-dimensional flow separations and the unsteady nature caused by the interaction between primary and secondary air flows throughout the fan. In this paper, an aerodynamic study on a forward-curved centrifugal fan has been carried out Firstly we obtained the fan performance curves versus flow rates showing its unstable nature in the surging operation range. Secondly aerodynamic characterizations were carried out by investigating the velocity and pressure fields in the casing flow passage using a 5-hole pilot probe, at different operating conditions. Surface flow pattern near the cut-off area exhibits similar flow behavior above the best efficiency operating point, although the pressure level increases substantially with the Increase of flow rate. Vorticity in the casing passage flow occurs in all (low rates, downstream from the r-Z plane $\theta$=120 deg., where the position of its core changes with the circumferential location. Although complex, the general flow behavior were common, giving insight in its main aerodynamic features.

  • PDF

Endoscopic Transforaminal Suprapedicular Approach in High Grade Inferior Migrated Lumbar Disc Herniation

  • Kim, Hyeun-Sung;Ju, Chang-Il;Kim, Seok-Won;Kim, Jong-Gue
    • Journal of Korean Neurosurgical Society
    • /
    • 제45권2호
    • /
    • pp.67-73
    • /
    • 2009
  • Objective : Although endoscopic procedures for lumbar disc diseases have improved greatly, the postoperative outcomes for high grade inferior migrated discs are not satisfactory. Because of anatomic limitations, a rigid endoscope cannot reach all lesions effectively. The purpose of this study was to determine the feasibility of endoscopic transforaminal suprapedicular approach to high grade inferior-migrated lumbar disc herniations. Methods : Between May 2006 and March 2008, a suprapedicular approach was performed in 53 patients with high grade inferior-migrated lumbar disc herniations using a rigid endoscope and a semi-rigid flexible curved probe. One-to-four hours after surgery, the presence of remnant discs was checked with MRI. The outcomes were evaluated with the visual analogue scale (VAS) score and the Oswestry Disability Index (ODI) one week after surgery. Results : The L2-3 level was involved in 2 patients and the L3-4 level was involved in 14 patients, while the L4-5 level was involved in 39 patients. There were single piece-type in 34 cases and a multiple piece-type in 19 cases. Satisfactory results were obtained in all cases. The mean preoperative VAS for leg pain was $9.32{\pm}0.43$ points (range, 7-10 points), whereas the mean ODI was $79.82{\pm}4.53$ points (range, 68-92 points). At the last follow-up examination, the mean postoperative VAS for leg pain was $1.78{\pm}0.71$ points and the mean postoperative ODI improved to $15.27{\pm}3.82$ points. Conclusion : A high grade inferior migrated lumbar disc is difficult to remove sufficiently by posterolateral endoscopic lumbar dscectomy using a rigid endoscope. However, a satisfactory result can be obtained by applying a transforaminal suprapedicular approach with a flexible semi-rigid curved probe.

단순변형률 조건 하의 회전하는 가변단면 $90^{\circ}$ 곡덕트내 외향 난류유동 측정 (Measurement of Outward Turbulent Flows Subject to Plane Rate of Strain in a Rotating 90 Deg. Curved Duct of Variable Cross-Section)

  • 오창민;최영돈
    • 대한기계학회논문집B
    • /
    • 제24권5호
    • /
    • pp.623-631
    • /
    • 2000
  • Hot-wire measurements were carried out on the developing turbulent flows subject to plane rate of strain in a rotating curved duct. The cross-section of the curved duct varies from 100mm${\times}$50mm rectangular shape at the bend inlet gradually to the 50mm${\times}$100mm rectangular shape at the bend outlet. Experimental setup consists of the test section of $90^{\circ}$ curved duct, rotating disc of 1.95m diameter, Ag-Ni precision slip ring, automatic traversing mechanism, variable speed motor, centrifugal blower, orifice flowmeter and hot-wire anemometer. Data signals from the rotating curved duct are transmitted through the slip ring to the computer which is located at the outside of the rotating disc. 3-dimensional velocity and 6 Reynold stresses components were obtained from the fluctuating and mean voltage measured by the slant type hot-wire probe rotating into 6 orientations. We investigate the effects of Coriolis and centrifugal forces on the turbulence structure.

2차원 Coanda 노즐 제트 의 특성 에 관한 실험적 연구 (Experimental Study of the Characteristics of 2-Dimensional Coanda Nozzle Jet)

  • 이동호;정명균;김응태
    • 대한기계학회논문집
    • /
    • 제6권3호
    • /
    • pp.222-231
    • /
    • 1982
  • A single free jet formed by the interaction of two curved wall jets on a Cylinder surface is defined as "the Coanda nozzle jet" in this study. In order to investigate the characteristics of Coanda nozzle jet, an experimental analysis was carried out; measurements of the static pressure distribution on the cylinder surface, the mean velocity profile, the turbulence intensity, and the Reynolds shear stress by using x-type hot-wire probe.ire probe.

3차원 측정기를 위한 원자간력 프로브 성능 연구 (A Study on the Performance of Atomic Force Probe for Coordinate Measuring Machines)

  • 정판곤;배규현;홍성욱
    • 한국공작기계학회논문집
    • /
    • 제17권4호
    • /
    • pp.75-80
    • /
    • 2008
  • This paper presents an atomic force probe for triggering coordinate measuring machines(CMMs). A rigorous comparison is made between touch trigger probe and atomic force probe for CMMs. Typical CMMs(touch trigger probe based CMMs) often lead to some errors associated with object curvature and difference in triggering sensitivity. Their applicability is limited only to hard objects. The aim of this work is to develop a trigger sensor for CMMs using atomic force. In order to show the applicability of atomic force as a trigger sensor, a cylindrical shape is measured with a CMM and an atomic force microscope. Three different touch probe heads with different ball sizes are tested. The experiments show that smaller ball provides better results for curved objects. The experimental results also show that the performance of atomic force as a trigger sensor is about that of the smallest ball probe. In addition, experiments are also performed to measure soft objects. Finally, this paper suggests and verifies a trigger sensor using atomic force for CMMs.