• Title/Summary/Keyword: Curved probe

Search Result 16, Processing Time 0.029 seconds

A Study on the Reflectivity according to the Material of Biopsy Gun Needle Used in Ultrasound Biopsy (초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구)

  • Hoon Kim;Cheong-Hwan Lim
    • Journal of radiological science and technology
    • /
    • v.47 no.2
    • /
    • pp.97-105
    • /
    • 2024
  • The examination needle used in ultrasound biopsy is a medical device used to determine whether there is an abnormality in the tissue. Typically, stainless steel is the standard material used for such needles; however, this study wanted to identify a material that could better enhance sound compared to traditional stainless steel. In this study, six types of needle materials available with the biopsy gun were inserted into pork and ultrasound images according to the curved probe and linear probe were evaluated using ultrasound equipment. The findings revealed significant improvements in ultrasound acoustic enhancement with alternative materials compared to stainless steel (p<0.05). The results regarding the depth of each ultrasound image using the curved probe showed that tungsten and brass had high sound enhancement(p<0.05), while with the linear probe, sound enhancement was high in brass, pla, aluminum, and copper(p<0.05). Due to these results, the previously used stainless needle showed lower ultrasound acoustic enhancement than the five types of materials being compared. Consequently, the outcomes of this study provide valuable insights for the development of new needle technologies aimed at minimizing patient risks and improving diagnostic accuracy.

Strategies for Noncontained Lumbar Disc Herniation by an Endoscopic Approach : Transforaminal Suprapedicular Approach, Semi-Rigid Flexible Curved Probe, and 3-Dimensional Reconstruction CT with Discogram

  • Chae, Ki-Hwan;Ju, Chang-Il;Lee, Seung-Myung;Kim, Byoung-Wook;Kim, Saeng-Youp;Kim, Hyeun-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.4
    • /
    • pp.312-316
    • /
    • 2009
  • Objective : The purpose of this study was to evaluate the efficacy of a transforaminal suprapedicular approach, semi-rigid flexible curved probe, and 3-dimensional reconstruction computed tomography (3D-CT) with discogram in the endoscopic treatment of non-contained lumbar disc herniations. Methods : The subjects were 153 patients with difficult, non-contained lumbar disc herniations undergoing endoscopic treatment. The types of herniation were as follows : extraforaminal, 17 patients; foraminal, 21 patients; high grade migration, 59 patients; and high canal compromise, 56 patients. To overcome the difficulties in endoscopic treatment, the anatomic structures were analyzed by 3D reconstruction CT and the high grade disc was extracted using a semi-rigid flexible curved probe and a transforaminal suprapedicular approach. Results : The mean follow-up was 18.3 months. The mean visual analogue scale (VAS) of the patients prior to surgery was 9.48, and the mean postoperative VAS was 1.63. According to Macnab's criteria, 145 patients had excellent and good results, and thus satisfactory results were obtained in 94.77% cases. Conclusion : In a posterolateral endoscopic lumbar discectomy, the difficult, non-contained disc is considered to be the most important factor impeding the success of surgery. By applying a semi-rigid flexible curved probe and using a transforaminal suprapedicular approach, good surgical results can be obtained, even in high grade, non-contained disc herniations.

Experimental Study on the Mean Flow Characteristics of Forward-Curved Centrifugal Fans

  • Kwon, Eui-Yong;Cho, Nam-Hyo
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.12
    • /
    • pp.1728-1738
    • /
    • 2001
  • Measurements have been made in an automotive HVAC b1ower for two different centrifugal fans. This work is directed at improving the performance of a conventional forward-curved centrifugal fan for a given small blower casing. Mean velocities and pressure have been measured using a miniature five-hole probe and a pressure scanning unit connected to an online data acquisition system. First, we obtained the fan performance versus flow rates showing a significant attenuation of unstable nature achieved with the new fan rotor in the surging operation range. Second, aerodynamic characterizations were carried out by investigating the velocity and pressure fields in the casing flow passage for different fan operating conditions. The measurements stowed that performance coefficients are strongly influenced by flow characteristics at the throat region. The main flow features ware common in both fans, but improved performance is achieved with tole new fan rotor, particularly in lower flow rate legions. Based on the measured results, design improvements were carried out in an acceptable operation range, which gave considerable insight into what features of flow behavior ware most important.

  • PDF

Acoustic Power Measurement System of Array Probes for Ultrasonic Diagnostic Equipment Using Radiation Force Balance Methods (방사힘 측정법을 이용한 초음파 진단장치용 배열 탐침자의 음향파워 측정시스템)

  • Yun, Yong-Hyeon;Jho, Moon-Jae;Kim, Yong-Tae;Lee, Myoung-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.6
    • /
    • pp.355-364
    • /
    • 2010
  • Considering biological safety, it is very important to measure acoustic power from ultrasonic array probe for diagnostic ultrasound imaging applications. In this paper, to measure acoustic power from each element on array probe for ultrasonic diagnostic equipment, we reconstruct and automate the acoustic power measurement system. The acoustic power from linear, phased and curved array were measured and analyzed. As a result of measurement, the effects caused by directivity of sound beam from curved array were founded. To remove these effects, we developed and applied the correction model. The proposed system is useful to evaluate characteristics of the acoustical output power of array probe.

Process Development of Forming of One Body Fine Pitched S-Type Cantilever Probe in Recessed Trench for MEMS Probe Card (멤스 프로브 카드를 위한 깊은 트렌치 안에서 S 모양의 일체형 미세피치 외팔보 프로브 형성공정 개발)

  • Kim, Bong-Hwan
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • We have developed the process of forming one body S-type cantilever probe in the recessed trench for fine-pitched MEMS probe card. The probe (cantilever beam and pyramid tip) was formed using Deep RIE etching and wet etching. The pyramid tip was formed by the wet etching using KOH and TMAH. The process of forming the curved probe was also developed by the wet etching. Therefore, the fabricated probe is applicable for the probe card for DRAM, Flash memory and RF devices tests and probe tip for IC test socket.

Experimental Study on the Performance of a Forward-Curved Centrifugal Fan for an Automotive Air-Conditioner (자동차 에어컨용 전곡형 원심 송풍기의 공력성능 분석)

  • Kwon, Eui-Yong;Cho, Nam-Hyo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.122-128
    • /
    • 2000
  • Aerodynamic optimization of an automotive air-conditioning blower is a hard task because of the highly complex flow phenomena related to three-dimensional flow separations and the unsteady nature caused by the interaction between primary and secondary air flows throughout the fan. In this paper, an aerodynamic study on a forward-curved centrifugal fan has been carried out Firstly we obtained the fan performance curves versus flow rates showing its unstable nature in the surging operation range. Secondly aerodynamic characterizations were carried out by investigating the velocity and pressure fields in the casing flow passage using a 5-hole pilot probe, at different operating conditions. Surface flow pattern near the cut-off area exhibits similar flow behavior above the best efficiency operating point, although the pressure level increases substantially with the Increase of flow rate. Vorticity in the casing passage flow occurs in all (low rates, downstream from the r-Z plane $\theta$=120 deg., where the position of its core changes with the circumferential location. Although complex, the general flow behavior were common, giving insight in its main aerodynamic features.

  • PDF

Endoscopic Transforaminal Suprapedicular Approach in High Grade Inferior Migrated Lumbar Disc Herniation

  • Kim, Hyeun-Sung;Ju, Chang-Il;Kim, Seok-Won;Kim, Jong-Gue
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.2
    • /
    • pp.67-73
    • /
    • 2009
  • Objective : Although endoscopic procedures for lumbar disc diseases have improved greatly, the postoperative outcomes for high grade inferior migrated discs are not satisfactory. Because of anatomic limitations, a rigid endoscope cannot reach all lesions effectively. The purpose of this study was to determine the feasibility of endoscopic transforaminal suprapedicular approach to high grade inferior-migrated lumbar disc herniations. Methods : Between May 2006 and March 2008, a suprapedicular approach was performed in 53 patients with high grade inferior-migrated lumbar disc herniations using a rigid endoscope and a semi-rigid flexible curved probe. One-to-four hours after surgery, the presence of remnant discs was checked with MRI. The outcomes were evaluated with the visual analogue scale (VAS) score and the Oswestry Disability Index (ODI) one week after surgery. Results : The L2-3 level was involved in 2 patients and the L3-4 level was involved in 14 patients, while the L4-5 level was involved in 39 patients. There were single piece-type in 34 cases and a multiple piece-type in 19 cases. Satisfactory results were obtained in all cases. The mean preoperative VAS for leg pain was $9.32{\pm}0.43$ points (range, 7-10 points), whereas the mean ODI was $79.82{\pm}4.53$ points (range, 68-92 points). At the last follow-up examination, the mean postoperative VAS for leg pain was $1.78{\pm}0.71$ points and the mean postoperative ODI improved to $15.27{\pm}3.82$ points. Conclusion : A high grade inferior migrated lumbar disc is difficult to remove sufficiently by posterolateral endoscopic lumbar dscectomy using a rigid endoscope. However, a satisfactory result can be obtained by applying a transforaminal suprapedicular approach with a flexible semi-rigid curved probe.

Measurement of Outward Turbulent Flows Subject to Plane Rate of Strain in a Rotating 90 Deg. Curved Duct of Variable Cross-Section (단순변형률 조건 하의 회전하는 가변단면 $90^{\circ}$ 곡덕트내 외향 난류유동 측정)

  • Oh, Chang-Min;Choi, Young-Don
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.5
    • /
    • pp.623-631
    • /
    • 2000
  • Hot-wire measurements were carried out on the developing turbulent flows subject to plane rate of strain in a rotating curved duct. The cross-section of the curved duct varies from 100mm${\times}$50mm rectangular shape at the bend inlet gradually to the 50mm${\times}$100mm rectangular shape at the bend outlet. Experimental setup consists of the test section of $90^{\circ}$ curved duct, rotating disc of 1.95m diameter, Ag-Ni precision slip ring, automatic traversing mechanism, variable speed motor, centrifugal blower, orifice flowmeter and hot-wire anemometer. Data signals from the rotating curved duct are transmitted through the slip ring to the computer which is located at the outside of the rotating disc. 3-dimensional velocity and 6 Reynold stresses components were obtained from the fluctuating and mean voltage measured by the slant type hot-wire probe rotating into 6 orientations. We investigate the effects of Coriolis and centrifugal forces on the turbulence structure.

Experimental Study of the Characteristics of 2-Dimensional Coanda Nozzle Jet (2차원 Coanda 노즐 제트 의 특성 에 관한 실험적 연구)

  • 이동호;정명균;김응태
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.6 no.3
    • /
    • pp.222-231
    • /
    • 1982
  • A single free jet formed by the interaction of two curved wall jets on a Cylinder surface is defined as "the Coanda nozzle jet" in this study. In order to investigate the characteristics of Coanda nozzle jet, an experimental analysis was carried out; measurements of the static pressure distribution on the cylinder surface, the mean velocity profile, the turbulence intensity, and the Reynolds shear stress by using x-type hot-wire probe.ire probe.

A Study on the Performance of Atomic Force Probe for Coordinate Measuring Machines (3차원 측정기를 위한 원자간력 프로브 성능 연구)

  • Jung, P.G.;Bae, G.H.;Hong, S.W.
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.4
    • /
    • pp.75-80
    • /
    • 2008
  • This paper presents an atomic force probe for triggering coordinate measuring machines(CMMs). A rigorous comparison is made between touch trigger probe and atomic force probe for CMMs. Typical CMMs(touch trigger probe based CMMs) often lead to some errors associated with object curvature and difference in triggering sensitivity. Their applicability is limited only to hard objects. The aim of this work is to develop a trigger sensor for CMMs using atomic force. In order to show the applicability of atomic force as a trigger sensor, a cylindrical shape is measured with a CMM and an atomic force microscope. Three different touch probe heads with different ball sizes are tested. The experiments show that smaller ball provides better results for curved objects. The experimental results also show that the performance of atomic force as a trigger sensor is about that of the smallest ball probe. In addition, experiments are also performed to measure soft objects. Finally, this paper suggests and verifies a trigger sensor using atomic force for CMMs.