• Title/Summary/Keyword: Curved Canal

Search Result 81, Processing Time 0.028 seconds

Comparison of the centering ability of Wave.One and Reciproc nickel-titanium instruments in simulated curved canals

  • Lim, Young-Jun;Park, Su-Jung;Kim, Hyeon-Cheol;Min, Kyung-San
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.1
    • /
    • pp.21-25
    • /
    • 2013
  • Objectives: The aim of this study was to evaluate the shaping ability of newly marketed single-file instruments, Wave One (Dentsply-Maillefer) and Reciproc (VDW GmbH), in terms of maintaining the original root canal configuration and curvature, with or without a glide-path. Materials and Methods: According to the instruments used, the blocks were divided into 4 groups (n = 10): Group 1, no glide-path / Wave One; Group 2, no glide-path / Reciproc; Group 3, #15 K-file / Wave One; Group 4, #15 K-file / Reciproc. Pre- and post-instrumented images were scanned and the canal deviation was assessed. The cyclic fatigue stress was loaded to examine the cross-sectional shape of the fractured surface. The broken fragments were evaluated under the scanning electron microscope (SEM) for topographic features of the cross-section. Statistically analysis of the data was performed using one-way analysis of variance followed by Tukey's test (${\alpha}$ = 0.05). Results: The ability of instruments to remain centered in prepared canals at 1 and 2 mm levels was significantly lower in Group 1 (p < 0.05). The centering ratio at 3, 5, and 7 mm level were not significantly different. Conclusions: The Wave One file should be used following establishment of a glide-path larger than #15.

A STUDY ON THE SHAPE OF A CANAL PREPARED WITH 'THREE-FILE' TECHNIQUE IN A CURVED CANAL ('Three-File' 방식에 의한 만곡 근관 형성시 근관의 형태에 관한 연구)

  • Park, Han-Soo;Lee, Min-Koo;Kim, Jong-Jin;Lim, Young-Jun;Jang, Moon-Sung;Lee, Jong-Yeop
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.4
    • /
    • pp.494-498
    • /
    • 2000
  • 이 연구의 목적은 'Three-File' 방식에 의한 근관형성시 근관의 형태변화 및 전이정도를 분석하고 이를 기존의 근관형성방법과 비교하고자 하는 것이다. 만곡된 근관을 가진 투명한 레진블럭 상에서 'Three-File' 방식, crown-down방식 및 스테인레스강 화일에 의한 수동방식으로 근관형성을 시행하고 이를 똑같은 위치가 재현가능한 고정틀에 위치시킨 후 사진의 이중노출 기법을 이용하여 근관형성 전후의 근관의 형태변화 및 전이정도를 분석한 결과 다음과 같은 결과를 얻었다. 1. 스테인레스강 화일의 경우 근관확대가 가장 컸고 근관의 전이정도도 심하였으며, 형성된 근관이 taper하지 못하고 불규칙한 형태를 보였다. 2. Profile로 crown-down방식에 의해 형성한 경우 taper한 근관형태를 보였고, 근관의 전이 정도도 스테인레스강 화일의 경우보다 작았다(p<0.01). 3. Profile로 'Three-File'방식에 의해 형성한 경우 taper한 근관형태를 보였고 근관의 전이정도도 스테인레스강 화일의 경우보다 유의하게 작았으나(p<0.01), crown-down방식에 의해 형성한 경우와 유의할 만한 차이는 없었다(p>0.01).

  • PDF

Endodontic treatment of mandibular molar with root dilaceration using Reciproc single-file system

  • Meireles, Daniely Amorin;Bastos, Mariana Mena Barreto;Marques, Andre Augusto Franco;Garcia, Lucas Da Fonseca Roberti;Sponchiado, Emilio Carlos Junior
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.3
    • /
    • pp.167-171
    • /
    • 2013
  • Biomechanical preparation of root canals with accentuated curvature is challenging. New rotatory systems, such as Reciproc, require a shorter period of time to prepare curved canals, and became a viable alternative for endodontic treatment of teeth with root dilaceration. Thus, this study aimed to report a clinical case of endodontic therapy of root with accentuated dilaceration using Reciproc single-file system. Mandibular right second molar was diagnosed as asymptomatic irreversible pulpitis. Pulp chamber access was performed, and glide path was created with #10 K-file (Dentsply Maillefer) and PathFile #13, #16 and #19 (Dentsply Maillefer) up to the temporary working length. The working length measured corresponded to 20 mm in the mesio-buccal and mesio-lingual canals, and 22 mm in the distal canal. The R25 file (VDW GmbH) was used in all the canals for instrumentation and final preparation, followed by filling with Reciproc gutta-percha cones (VDW GmbH) and AH Plus sealer (Dentsply Maillefer), using thermal compaction technique. The case has been receiving follow-up for 6 mon and no painful symptomatology or periapical lesions have been found. Despite the difficulties, the treatment could be performed in a shorter period of time than the conventional methods.

Comparison of screw-in effect of three NiTi file systems used by undergraduates (학생들이 사용한 세 종류 NiTi file systems의 screw-in effect 비교)

  • Oh, Seung-Hei;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.6
    • /
    • pp.477-484
    • /
    • 2006
  • The purposes of this study were to compare the apical terminus width of simulated curved root canal prepared with three NiTi file systems used by undergraduates for evaluation the effects of flute angle and pitch or radial land on reducing screw-in effect and to determine more safe NiTi file system for inexperienced operators. Fifty inexperienced undergraduate students prepared 150 simulated curved root canals in resin blocks with three NiTi file systems ; ProFile$^{(R)}$, Hero Shaper$^{(R)}$, K3$^{TM}$. The electric motor set at a speed of 300 rpm and torque of 30 in a 16 : 1 reduction handpiece was used. The simulated root canal was prepared to ISO #25 sizes with each file system. The scanned images of pre- and post-instrumented canal of resin block were superimposed. To evaluate the screw-in effect of three NiTi file systems, apical terminus width of root canal was measured from superimposed images and statistical analysis was performed. There were significant differences in three NiTi flle systems. ProFile$^{(R)}$ had significantly smaller width than Hero Shaper$^{(R)}$ and K3$^{TM}$"" (P < 0.05), but no significant difference was observed between K3$^{TM}$ and Hero Shaper$^{(R)}$. Under the condition of this study, active file system (Hero SHaper$^{(R)}$, K3$^{TM}$) with variable pitch and helical angle had more screw-in effect than passive file system (ProFile$^{(R)}$) with constant pitch and helical angle. It seems that the radial lands play more important role in reducing screw-in effect.

Cyclic fatigue resistance of M-Pro and RaCe Ni-Ti rotary endodontic instruments in artificial curved canals: a comparative in vitro study

  • Feky, Hadeer Mostafa El;Ezzat, Khalid Mohammed;Bedier, Marwa Mahmoud Ali
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.4
    • /
    • pp.44.1-44.11
    • /
    • 2019
  • Objectives: To compare the flexural cyclic fatigue resistance and the length of the fractured segments (FLs) of recently introduced M-Pro rotary files with that of RaCe rotary files in curved canals and to evaluate the fracture surface by scanning electron microscopy (SEM). Materials and Methods: Thirty-six endodontic files with the same tip size and taper (size 25, 0.06 taper) were used. The samples were classified into 2 groups (n = 18): the M-Pro group (M-Pro IMD) and the RaCe group (FKG). A custom-made simulated canal model was fabricated to evaluate the total number of cycles to failure and the FL. SEM was used to examine the fracture surfaces of the fragmented segments. The data were statistically analyzed and comparisons between the 2 groups for normally distributed numerical variables were carried out using the independent Student's t-test. A p value less than 0.05 was considered to indicate statistical significance. Results: The M-Pro group showed significantly higher resistance to flexural cyclic fatigue than the RaCe group (p < 0.05), but there was no significant difference in the FLs between the 2 groups (p ≥ 0.05). Conclusions: Thermal treatment of nickel-titanium instruments can improve the flexural cyclic fatigue resistance of rotary endodontic files, and the M-Pro rotary system seems to be a promising rotary endodontic file.

The EFFECTS OF VARIOUS INSTRUMENTATION TECHNIQUES IN CURVED CANALS OF RESIN BLOCKS (만곡근관에서 수동식 기구와 엔진 구동형 기구의 근관성형 효과에 대한 비교 연구)

  • Jung, Il-Young;Yoon, Tai-Cheol;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.648-658
    • /
    • 1997
  • The purpose of this study was to compare the effects of various techniques on the quality and quantity of instrumentation in curved canals. Instrumentation time was evaluated too. Forty eight canals of resin blocks($35^{\circ}$) were divided into three groups and filed. In group A, 16 blocks were instrumented using a step-back technique with stainless steel(SS) K-file(Mani, Matsutani Seisakusho Co.,Japan). In group B, canals were prepared with SS K-files using the Endo-Angle (Nakanishi Dental MFG.CO.,LTD.,Japan). Group C was prepared using N i-Ti engine-driven instruments (Quantec Series $2000^{TM}$ system). Group A and B were filed from # 5 to # 25 at the apex followed by a 1 mm stepback technique, and the coronal half of the canals were flared with Gates Glidden burs(#2,3,4). Group C was instrumented from # 1 to # 8. After the instrumentation time was measured, canals were filled with India ink, and photographed, which to magnify the canal images 8 times. Using these photographs the apical portions were evaluated And scored from 1 to 4 according to the severity of ledging and zipping. On the same photographs, the area of the coronal two thirds of the canals were measured using a personal computer with the computer program Brain and Digitizer (SummaSketch III). The following results were obtained. 1. Instrumentation time was significantly shorter for group C, as opposed to group A and B(ANOVA, P<0.05). 2. The qualitative evaluation of the apical portions of the canals showed no significant difference between the groups(Kruscal-Wallis, p>0.05). 3. The area removed by group C was significantly smaller than group A and B(ANOVA, P<0.05).

  • PDF

Assessment of Root and Root Canal Morphology of Human Primary Molars using CBCT (CBCT를 이용한 유구치의 치근 및 근관의 형태학적 평가)

  • Choi, Yoomin;Kim, Seonmi;Choi, Namki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.1
    • /
    • pp.25-35
    • /
    • 2020
  • The purpose of this study is to evaluate the morphological characteristics of the roots and roots canals of primary molar teeth using Cone-Beam Computed Tomography (CBCT). A total of 68 CBCT images of children aged 4 - 5 years was used for this study. A total of 160 molar teeth were analyzed. Various parameters such as the number of roots and canals, length of root and root canal, and the angulation and shape of the roots were analyzed. All maxillary primary molars had 3 roots. The presence of 2 root canals in 1 root was only observed in the mesiobuccal root of maxillary primary second molars. Most mandibular primary molars had 2 roots, and most mesial roots had 2 root canals. Concerning the length of the roots, the palatal root of the maxillary primary molar was found to be longest whereas the distobuccal root was shortest. In mandibular primary molars, the mesial root was longer than the distal root. In maxillary primary molars, the palatal root had the greatest angulation whereas the distal root has the greatest in mandibular molars. The root and root canals of maxillary primary molars were more curved in shape whereas mandibular primary molars were straight.

A Design Principles and Characteristics of the Garden of Salt Merchant in Yangzhou, China's Ming and Qing Dynasties (중국 명·청 양주 염상원림의 설계원리 및 조영특성)

  • Shin, Hyun-Sil
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.37 no.3
    • /
    • pp.83-92
    • /
    • 2019
  • This study aims to examine at the garden characteristics of salt merchant in Yangzhou, China during the Ming and Qing Dynasties, I looked at the background of garden formation through the literature. In addition, analyzed the garden design method and components of salt merchants. The results were as follows; First, the Yangzhou area in the past has achieved cultural and economic development with the establishment of the ancient Grand Canal. Salt merchants accumulated wealth through trade, and created many gardens under the background of securing materials for create garden through trade, forming political forces through the cultivation of students, and inflow of foreign cultures. Second, salt merchants in Yangzhou asked garden experts to design and create the garden as a place for exchange and relaxation. Also, through the production of landscape changes using Gasan(假山) and a long corridor(長廊), clear classification of spaces using architectural elements, and the placement of buildings in scenic areas adjacent to the water, the gardens with practical and aesthetic functions were owned. Third, the gardens of Yangzhou Salt Merchants have a building-oriented commercial space on the front, and a garden-centered design characteristic on the back. The garden of the commercial zone was built in a simple form using pots, oddly shaped stone, bamboo and fence patterns in the remained space, focusing on the front of the building. The garden at the back formed a curved waterway connected to the canal is refracted across the garden. The garden also features piled stones(疊石), stone bridges and ship-shaped stone building(石舫). In addition, the design reflected the introduction of trees that take into account the climate and color contrast of Yangzhou province, pavement of various materials and patterns.

Obturation efficiency of non-standardized gutta-percha cone in curved root canals prepared with 0.06 taper nickel-titanium instruments (0.06-경사도의 니켈-티타늄 기구로 형성된 레진 만곡근관에서 비표준화 GUTTA-PERCHA CONE의 근관충전 효율)

  • Lee, Eun-Ah;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.2
    • /
    • pp.79-85
    • /
    • 2005
  • The purpose of this study was to evaluate the obturation efficiency of a non-standardized gutta-percha cone in curved root canals prepared with 0.06 taper nickel-titanium instruments. Sixty simulated curved root canals in clear resin blocks were prepared with crown-down technique using 0.06 taper rotary $ProTaper^{TM}$and ProFile (Dentsply-Maillefer) until apical canal was size 30. Root canals were randomly divided into 4 groups of 15 blocks and obturated with cold-laterally compacted gutta-percha technique by using either a non-standardized size medium gutta-percha cone or an ISO-standardized size 30 one as a master cone. Gutta-percha area ratio were calculated at apical levels of 1, 3 and 5 mm using AutoCAD 2000 after cross-sectioning, and the data were analyzed with one-way and two-way ANOVAs and Duncan's multiple range test. Non-standardized size medium cone groups showed significantly higher gutta-percha area ratio than standardized cone groups at all apical levels (p < 0.01). Non-standardized cone groups used significantly less accessory cones than standardized cone groups (p < 0.01).

COMPARISON OF SCREW-IN EFFECT FOR SEVERAL NICKEL-TITANIUM ROTARY INSTRUMENTS IN SIMULATED RESIN ROOT CANAL (모형 레진 근관에서 수종의 전동 니켈-티타늄 파일에 대한 screw-in effect 비교)

  • Ha, Jung-Hong;Jin, Myoung-Uk;Kim, Young-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.4
    • /
    • pp.267-272
    • /
    • 2010
  • Screw-in effect is one of the unintended phenomena that occurs during the root canal preparation with nickel-titanium rotary files. The aim of this study was to compare the screw-in effect among various nickel-titanium rotary file systems. Six different nickel-titanium rotary instruments (ISO 20/.06 taper) were used: $K3^{TM}$ (SybronEndo, Glendora, CA, USA), $M_{two}$ (VDW GmbH, Munchen, Germany), NRT with safe-tip and with active tip (Mani Inc., Shioya-gun, Japan), ProFile$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland) and ProTaper$^{(R)}$ (Dentsply-Maillefer, Ballaigues, Switzerland). For ProTaper$^{(R)}$, S2 was selected because it has size 20. Root canal instrumentations were done in sixty simulated single-curved resin root canals with a rotational speed of 300 rpm and single pecking motion. A special device was designed to measure the force of screw-in effect. A dynamometer of the device recorded the screw-in force during simulated canal preparation and the recorded data was stored in a computer with designed software (LCV-USE-VS, Lorenz Messtechnik GmbH, Alfdorf, Germany). The data were subjected to one-way ANOVA and Tukey's multiple range test for post-hoc test. P value of less than 0.05 was regarded significant. ProTaper$^{(R)}$ produced significantly more screw-in effects than any other instruments in the study (p < 0.001). $K3^{TM}$ produced significantly more screw-in effects than $M_{two}$, and ProFile$^{(R)}$ (p < 0.001). There was no significant difference among $M_{two}$, NRT, and ProFile$^{(R)}$ (p > 0.05), and between NRT with active tip and NRT with safe one neither (p > 0.05). From the result of the present study, it was concluded, therefore, that there seems significant differences of screw-in effect among the tested nickel-titanium rotary instruments. The radial lands and rake angle of nickel-titanium rotary instrument might be the cause of the difference.