• Title/Summary/Keyword: Curve measurement

Search Result 991, Processing Time 0.04 seconds

THE EFFECT OF ABUTMENT HEIGHT ON SCREW LOOSENING IN SINGLE IMPLANT-SUPPORTED PROSTHESES AFTER DYNAMIC CYCLIC LOADING

  • Kim Nam-Gun;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.664-670
    • /
    • 2004
  • Statement of problem. One of the common problems of dental implant prosthesis is the loosening of the screw that connects each component, and this problem is more common in single implant-supported prostheses with external connection. Purpose. The purpose of this study was to examine the changes of detorque values of abutment screws with external connection in different abutment heights. Materials and methods. After cyclic loading on three different abutment heights, detorque values were measured. Abutments were retained with titanium abutment screws tightened to 30 Ncm (30.5 kgmm) with digital torque gauge as recommended by the manufacturer. Replacing abutments, implants and titanium abutment screws with new ones at every measurement, initial detorque values were measured six times. In measuring de torque values after cyclic loading, Avana Cemented Abutments of 4.0 mm collar, 7.0 mm height (Osstem Co., Ltd., Seoul, Korea) were used with three different lengths of 5.0, 8.0, 11.0 mm. Shorter abutments were made by milling of 11.0 mm abutment to have the same force-exercised area of 4.5 mm diameter. Sine curve force (20N-320N, 14Hz) was applied, and detorque values were measured after cyclic loading of 2 million times by loading machine. Detorque values of initial and after-loading were measured by digital torque gauge. One-way ANOVA was employed to see if there was any influence from different abutment heights. Results. The results were as follows: 1. The initial detorque value was 27.8$\pm$0.93 kgmm, and the ratio of the initial detorque value to the tightening torque was 0.91(27.8/30.5). 2. Measured detorque values after cyclic loading were declined as the height of the abutment increased, that was, 5.0 mm; 22.3$\pm$0.82 kgmm, 8.0 mm; 21.8$\pm$0.93 kgmm, and 11.0 mm; 21.3$\pm$0.94 kgmm. 3. One-way ANOVA showed no statistically significant differences among these (p>0.05). 4. Noticeable mobility at the implant-abutment interface was not observed in any case after cyclic loading at all.

Hybrid Analysis of Displacement Behavior and Numerical Simulation on Tunnel Design (터널 변위 거동 및 수치 모의실험의 결합 해석)

  • Jeong, Yun-Young;Han, Heui-Soo;Lee, Jae-Ho
    • The Journal of Engineering Geology
    • /
    • v.20 no.1
    • /
    • pp.47-60
    • /
    • 2010
  • This study is focused on the analysis of tunnel behavior to estimate the stability on tunnel design. An estimation method was proposed as a hybrid consideration, which contains the displacement analysis by 3D numerical simulation, the maximum displacement obtained after field measurement, and an assessment of tunnel stability using a deformation analysis proposed by Sakurai(1988, 1997). The points of case study by Sakurai(1988, 1997) were replotted considering his analysis. From the new analysis of the tunnel case study, the trend line for analyzed points is analogized, which curve is divided into stable, unstable and failure zone. To evaluate the estimation method, a special shape of railway tunnel was selected, which are the Inchon international airport rail way connected to subway line 9 in Gimpo, Korea. The point s of upper and below track on the Inchon international airport rail way were satisfied to the stability of tunnel after reinforcing. Also the points shows the higher apparent Young's modulus, which resulted from improvement on shear strength by the micro silica grouting and the supporting of umbrella method. Therefore, if new analysis used, proper tunnel reinforcing method could be selected according to tunnel strain and geological property.

Photoelectric Properties of PbTe/CuPc Bilayer Thin Films (PbTe/CuPc 이층박막의 광전 특성)

  • Lee, Hea-Yeon;Kang, Young-Soo;Park, Jong-Man;Lee, Jong-Kyu;Jeong, Jung-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.67-72
    • /
    • 1998
  • The crystallized CuPc and PbTe films are formed by thermal evaporation and pulsed ArF excimer laser ablation. Structural and electrical properties of thin film is observed by XRD and current-voltage(I-V) curves. From XRD analysis, both PbTe and CuPc thin films show a-axis oriented structure. For the measurement of photovoltaic effect, the transverse current-voltage curve of CuPc/Si, PbTe/Si and PbTe/CuPc/Si junctions have been analyzed in the dark and under illumination. The PbTe/CuPc/Si junction exthibits a strong photovoltaic characteristics with short circuit current($J_{sc}$) of $25.46\;mA/cm^{2}$ and open-circuit voltage($V_{oc}$) of 170 mV. Quantum efficiency and power conversion efficiency are calculated to be 15.4% and $3.46{\times}10^{-2}$, respectively. Based on the results of QE and ${\eta}$, the photocurrent process of PbTe/CuPc/Si junction can be explained as following three effective steps; photocarrier generation in the CuPc layer, carrier separation at PbTe/CuPc interface, and finally a transportation of electrons through the PbTe layer.

  • PDF

Respiratory Sinus Arrhythmia: Methods of Measurement and Interpretations of Tonic and Dynamic Vagal Cardiac Drive Index in Psychophysiology of Emotions

  • Estate M.Sokhadze;Lee, Jong-Mi;Park, Mi-Kyung;Sohn, Jin-Hun
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.11a
    • /
    • pp.81-87
    • /
    • 2000
  • Beat-to-beat changes in heart period (heart period variability, HPV) are mediated by fluctuations in autonomic activity. Spectral analysis is used to quantify such fluctuations in the range of 0.15-0.40 Hz (high frequency, HF), which are influenced primarily by parasympathetic factors. These fluctuations are often referred to as RSA (respiratory sinus arrhythmia), the physiological phenomenon extracted by spectral analysis and other methods including histograms of heart rate ( HR), deviations of HR etc. Respiratory sinus arrhythmia indexing with peak-to-valley method suggested by Grossman et at., (1981) yields a simple range statistic and is quantified on breath-by-breath basis, thus being quite sensitive and less dependent on recording time as compared to spectral analysis. It is strongly recommended to use at least 1 min epoch to asses HF component of HPV and at least 2 min fer low frequency (LF) of HPV and even 5 min far valid clinical assessment. Peak-to-valley statistic is limited to RSA index only, but has its pragmatic advantages. Most important is possibility of its application far relatively small epoch analysis. We used short periods (20,30, 40 sec only) and off-line analysis of RSA using ECG and respiration curve this method of assessment and proved that this method is more practically effective. The RSA index was not so far dependent on respiration pattern differences and reflected actual vagal control of HR and were accompanied by low HR under some high stress conditions and in an aversive affective visual stimulation experiments. Another factor that might modulate cardiac chronotropic response is the interaction of sympathetic and parasympathetic inputs on sino-atrial (SA) node level, because responses to vagal influences are known to be proportional to ongoing sympathetic activity, that is so called accentuated antagonism. Since sympathetic outflow (increment of influences on SA) under negative emotions or stress was high in almost all physiological responses, vagal effects on HR could be therefore potentiated, leading to masking of output cardiac response seen in HPV, In the case of moderate sympathetic activation, on the other hand, autonomic interactions in cardiac control appear to be minimal. Thus RSA index appears to be an effective alternative method to assess and measure spectral HPV.

  • PDF

Dry Magnetic Particle Inspection of Ingot Cast Billets (강편 빌레트의 건식 자분 탐상)

  • Kim, Goo-Hwa;Lim, Zhong-Soo;Lee, Eui-Wan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.3
    • /
    • pp.162-173
    • /
    • 1996
  • Dry magnetic particle inspection(MPI) was performed to detect the surface defects of steel ingot cast billets. Magnetic properties of several materials were characterized by the measurement of the B-H hysteresis curve. The inspection results were evaluated in terms of the magnetizing current, temperature, and the amount of magnetic particles applied to billets. Magnetic flux leakage near the defect site of interest was measured and compared with the results of calculation by the finite element method in the case of direct magnetizing current. Direct and alternating magnetizing currents for materials were deduced by the comparison of the inspections. Results of the magnetic particle inspection by direct magnetizing current were compared with those of finite element method calculations, which were verified by measuring magnetic leakage flux above the surface and the surface defects of the material. For square rods, due to the geometrical effect, the magnetic flux density at the edges along the length of the rods was about 30% of that at the center of rod face for a sufficiently large direct magnetizing current, while it was about 70% for an alternating magnetizing current. Thus, an alternating magnetizing current generates rather uniform magnetic flux density over the rods, except for the region on the face across about 10 mm from the edge. The attraction of the magnetic particle by the magnetic leakage field was nearly independent of the surface temperature of the billets up to $150^{\circ}C$. However, the temperature should have been limited below $60^{\circ}C$ for an effective fixing of gathered magnetic particles to the billet surface using methylene chloride. We also found that the amount of applied magnetic particles tremendously affected the detection capability.

  • PDF

Migration Measurement of Volatile Organic Compounds (VOCs) from Polystyrene-made Food Containers into Distilled Water (폴리스티렌 식품용기로부터 증류수로 용출되는 휘발성유기화합물의 분석)

  • Kim, Nam-Hoon;Kim, Ae-Kyeong;Cho, Tae-Hee;Park, Kyung-Ai;Kwak, Jae-Eun;Kim, Ji-Young;Kim, Il-Young;Chae, Young-Joo;Kim, Min-Young
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.3
    • /
    • pp.203-208
    • /
    • 2010
  • In this study, the level of migration of 5 kinds of volatile organic compounds (VOCs) (toluene, styrene, ethylbenzene, isopropylbenzene and n-propylbenzene) into distilled water from polystyrene-made food containers was measured using Purge&Trap combined with GC/FID. The contents of the VOCs which have regulatory limits in Korea food code only for material specification were determined under three exposure conditions which were 30 min at $60^{\circ}C$, 30 min at $95^{\circ}C$ and actual situation of instant noodle intake. The calibration curve of 5 compounds showed good linearity ($^r2$ = 0.9976~0.9995) within the concentration range of 1~50 ng/mL. The limit of detection (LOD) and limit of quantification (LOQ) were validated at range of 0.041~0.092 and 0.135~0.304 ng/mL, respectively. The average migration contents of 5 compounds were below 5 ng/mL except for styrene. The average contents of styrene were highly detected at $95^{\circ}C$ for 30 min exposure (52.71 ng/mL). Under actual condition at instant noodle intake, the average contents of styrene was 17.23 ng/mL. The results demonstrated that the migration rate of VOCs was related to storage temperature and time.

Measurement of Biogenic Amines with a Chitopearl Enzyme Reactor (Chitopearl 효소 Reactor를 이용한 Biogenic Amines 측정)

  • Park, In-Seon;Kim, Dong-Kyung;Shon, Dong-Hwa;Cho, Yong-Jin;Kim, Nam-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.593-599
    • /
    • 1999
  • Substrate specificity of a flow-injection-analysis (FIA)-type biogenic amine sensor with enzyme reactor was determined. The enzyme reactor was prepared with a diamine oxidase immobilized on preactivated chitosan porous beads (Chitopearl) by intramolecular cross-linking via glutaraldehyde. The sensor showed a rapid response to putrescine and a quasi-linear calibration curve was obtained up to 15.0 mM. The optimal pH and temperature of the enzyme reactor system were 7.5 and $35^{\circ}C$. Interferences due to ATP-related compounds and trimethylamine, and the effects of NaCl and amino acids were measured. Inhibitory effects owing to these components could be mitigated by sample extraction with perchloric acid. Polyamines except putrescine were determined by a putrescine calibration range within 26.7%. This system was confirmed as rapid and convenient for biogenic amine determination.

  • PDF

Absorbed Dose Measurement by the MIRD System in the $^{131}I$ Treated Thyroid Cancer Patients (갑상선 암 환자에서 $^{131}I$ 치료시 MIRD Schema에 의한 흡수선량의 평가)

  • Lim, Sang-Moo;Woo, Kwang-Sun;Chung, Wee-Sup;Hong, Sang-Woon;Kim, Jang-Hee;Kim, Ki-Sup
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.54-60
    • /
    • 1995
  • Medical Internal Radiation Dose(MIRD) schema was developed for calculating the absorbed dose from the administered radiopharmaceuticals. With the biological distribution data and the physical properties of the radionuclide we can estimate the absorbed dose by the MIRD schema. For the thyroid cancer patients received $^{131}I$ therapy, the absorbed dose to the bone marrow is the limiting factor to the administered dose, and the duration of admission is deter-mined by the retained activity in the whole body. To monitor the whole body radioactivity, we used Eberline Smart 200 system using ionization chamber as a detector. With the time activity curve of the whole body, total body residence time was obtained. From the ICRP publication 53, the residence times of the source organs, such as kidney, urinary bladder content and stomach, were used to calculate the absorbed doses of the target organs, such as stomach, red marrow, bladder wall and remaineder total body. In 8 thyroid cancer patients with 175 mci of $^{131}I$ administered orally, the mean absorbed dose in the bladder wall was 375.1, in the stomach 285.1, red marrow 25.4 and total body 22.4 rad respectively. For the monitoring of the large administered activity, this method seemed to be quite useful.

  • PDF

Determination of Calibration Curve for Total Nitrogen Contents Analysis in Fresh Rice Leaves Using Visible and Near Infrared Spectroscopy (벼 생체엽신 질소함량 측정을 위한 근적외선분광분석의 검량식 작성)

  • Kwon Young-Rip;Baek Mi-Hwa;Choi Dong-Chil;Choi Joung-Sik;Choi Yeong-Geun
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.50 no.6
    • /
    • pp.394-399
    • /
    • 2005
  • Near Infrared Spectroscopy (NIRS) has been used as a tool for the rapid, accurate and nondestructive assay of the fresh rice leaf in nitrogen content. NIRS used in this study was visible and near infrared spectroscopy type instrument, Foss model 6500. To obtain a useful calibration equation, standard regression between the data was analyzed by chemical analysis and by NIRS method. Accuracy of calibration equation for nitrogen content on fresh leaf of rice were 0.879, 0.858 and 0.819, respectively. Accuracy of calibration equation after outlier treatment increased as 0.017, 0.02 and 0.061 improved each with 0.896, 0.878 and 0.880, respectively. Calibration equation combined using merge function after accuracy of calibration equation more increased by 0.911. Difference analysis value between calibration equation and lab value by kjeldahl showed $0.001\%$. With this as same result is the possibility of closing the deterioration of the sample in order to omit a construction and pulverization process it is judged with the fact that the nitrogen content measurement of the fresh rice leaf which the possibility of reducing an hour and an expense is by a near infrared spectroscopy technique will be possible.

Signal-Averaged P Wave Analysis in Patients with Paroxysmal Atrial Fibrillation (발작성 심방세동 환자의 신호평균 P파 분석)

  • 김인영;이종연;이병채;이용희;이종민;김선일;김준수
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • Atrial fibrillation(AF). chronic or paroxysmal is the most frequent arrhythmia in human subjects Duration of P wave in signal-averaged electrocardiography(SAECG) reflects intra-atrial conduction time and therefore. could be used as an electrophysiological marker for atrial conduction chance at the earthy stave. So we apply the analysis method using SAECG to diagnose Paroxysmal atrial fibrillation(PAF) . Subjects Participated for the study consisted of two groups: a control group(n=34) of normal healthy volunteers and a group of AF Patients(n=38) with a documented history of PAF but no other history of cardiac disease. We evaluated the effect of several filtering and determination methods to find the starting and ending feints of the P wavy on its duration. To increase the measurement reliability of P wave duration. the automatic detection method was proposed. Also. to increase the detection rate for PAF risk, the decision threshold value was optimized using receiver operation characteristics(ROC) curve. Results showed that the highest statistical difference (p〈0.001) of the P wane duration between controls and subjects was obtained at the Processing condition, using absolute threshold vague(8.75 $\mu N$) , a least mean square(LMS) high pass filter and 30 Hz cutoff frequency. The most outstanding difference(sensitivity 88 % specificity 64.4 %) between controls and subjects was obtained at the decision threshold value of 112 ms.