• Title/Summary/Keyword: Curvature Measurement

Search Result 219, Processing Time 0.023 seconds

Prediction of Curvature Effects on the Electromagnetic Flowmeter Characteristics with Numerical Simulation (Laminar flow) (곡관의 곡률에 따른 전자기유량계 설치효과의 수치모사에 의한 특성 예측(충류))

  • Lim, Ki Won;Choi, Sang Kyu;Chung, Myung Kyoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.11
    • /
    • pp.1453-1463
    • /
    • 1999
  • An electromagnetic flowmeter, based on a magnetic induction principle; provides an obstructionless flowmeter that essentially averages the velocity distribution over the pipe cross-sectional area. To predict the installation effects, the flowmeter installed near $90^{\circ}$ elbow is simulated by using a commercial code FLUENT(ver. 4.48) for the laminar flow field and a code developed through this study for magnetic field. The installation effects of the flowmeter are estimated by varying a number of the dependent parameters such as the radius of the elbow(Rc=1D, 1.5D, 2D, 3D), the location, Reynolds number and the direction of electrodes plane(${\varphi}$). It was found that all these factors affect the performance of the electromagnetic flowmeter significantly. The longer installation distance from the elbow is not always optimal to minimize the error, and also there exists an optimal location to install the EMF for a minimum error. Especially the flow signal with the electrodes plane direction of ${\varphi}=45^{\circ}$ is shown to yield smallest measurement error regardless of the Reynolds number and the curvature of elbow.

Structural damage localization using spatial wavelet packet signature

  • Chang, C.C.;Sun, Z.
    • Smart Structures and Systems
    • /
    • v.1 no.1
    • /
    • pp.29-46
    • /
    • 2005
  • In this study, a wavelet packet based method is proposed for identifying damage occurrence and damage location for beam-like structures. This method assumes that the displacement or the acceleration response time histories at various locations along a beam-like structure both before and after damage are available for damage assessment. These responses are processed through a proper level of wavelet packet decomposition. The wavelet packet signature (WPS) that consists of wavelet packet component signal energies is calculated. The change of the WPS curvature between the baseline state and the current state is then used to identify the locations of possible damage in the structure. Two numerical studies, one on a 15-storey shear-beam building frame and another on a simply-supported steel beam, and an experimental study on a simply-supported reinforced concrete beam are performed to validate the proposed method. Results show the WPS curvature change can be used to locate both single and sparsely-distributed multiple damages that exist in the structure. Also the accuracy of assessment does not seem to be affected by the presence of 20-15dB measurement noise. One advantage of the proposed method is that it does not require any mathematical model for the structure being monitored and hence can potentially be used for practical application.

Comparison of linear and non-linear equation for the calibration of roxithromycin analysis using liquid chromatography/mass spectrometry

  • Lim, Jong-Hwan;Yun, Hyo-In
    • Korean Journal of Veterinary Research
    • /
    • v.50 no.1
    • /
    • pp.11-17
    • /
    • 2010
  • Linear and non-linear regressions were used to derive the calibration function for the measurement of roxithromycin plasma concentration. Their results were compared with weighted least squares regression by usual weight factors. In this paper the performance of a non-linear calibration equation with the capacity to account empirically for the curvature, y = ax$^{b}$ + c (b $\neq$ 1) is compared with the commonly used linear equation, y = ax + b, as well as the quadratic equation, y = ax$^{2}$+ bx + c. In the calibration curve (range of 0.01 to 10 ${\mu}g/mL$) of roxithromycin, both heteroscedasticity and nonlinearity were present therefore linear least squares regression methods could result in large errors in the determination of roxithromycin concentration. By the non-linear and weighted least squares regression, the accuracy of the analytical method was improved at the lower end of the calibration curve. This study suggests that the non-linear calibration equation should be considered when a curve is required to be fitted to low dose calibration data which exhibit slight curvature.

Analysis of Curve Squeal Noise for Busan Metro Line 3 (부산 도시철도 3호선 차량 곡선부 스퀼소음 특성)

  • Hong, Do-Kwan;Ahn, Chan-Woo;Han, Geun-Jo;Gang, Hyeon-Uk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.4
    • /
    • pp.427-435
    • /
    • 2011
  • This paper deals with the measurement and analysis of the squeal noise according to the curvature of rail. The squeal noise is generated by the friction between the railway with curve and the wheel. The squeal noise is a big problem in Busan Metro Line 3. If the developing panel type ANC(Active Noise Control) system which is attached to the floor can reduce 5 dB in below 500 Hz, the sound pressure level of the whole band pass can be reduced about 4-4.8 dB in squeal noise above the curvature of R400. Curve squeal noise is the intense high frequency tonal that can occur when a railway vehicle transverses a curve. The frequency range is from around 500 to almost 20,000 Hz, with noise levels up to about 15 dB in curve.

Scoliosis Progression according to the Growth of Middle School Students (성장에 따른 중학생 척추측만증 이행양상)

  • Kim, Juk-Hyang;Kim, Eun-Ju
    • Research in Community and Public Health Nursing
    • /
    • v.14 no.3
    • /
    • pp.479-487
    • /
    • 2003
  • Purpose: This study was conducted to investigate the progression of Cobb's angle of middle school students according to the Risser grade changes during a one-year follow up period, and to identify the prevalence rate and related factors regarding scoliosis. Method: A total of 2,124 middle school students were preliminarily screened by the Adam's forward bending test. Among them, 21 adolescents diagnosed with scoliosis (above 5Cobb's angle) by X-Raying were the subjects and followed up for checking Cobb's angle and the Risser grade for one year. Results: The overall prevalence of scoliosis in middle school students was 2.13% and the prevalence in girls was higher than in boys. The Cobb's angle was significantly high in seniors and girls. The cases in low angle and low Risser grade demonstrated significant changes in progressive Cobb's angle compared to the cases in high angle and high Risser grade after one-year. But gender and pattern of curvature were not significantly different from the changes scoliosis angle after one-year. Conclusion: Based on these study results, juniors in low Risser grade were inclined to aggravate scoliosis despite the low degree of curvature at the first measurement.

  • PDF

The Container Pose Measurement Using Computer Vision (컴퓨터 비젼을 이용한 컨테이너 자세 측정)

  • 주기세
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.3
    • /
    • pp.702-707
    • /
    • 2004
  • This article is concerned with container pose estimation using CCD a camera and a range sensor. In particular, the issues of characteristic point extraction and image noise reduction are described. The Euler-Lagrange equation for gaussian and random noise reduction is introduced. The alternating direction implicit(ADI) method for solving Euler-Lagrange equation based on partial differential equation(PDE) is applied. The vertex points as characteristic points of a container and a spreader are founded using k order curvature calculation algorithm since the golden and the bisection section algorithm can't solve the local minimum and maximum problems. The proposed algorithm in image preprocess is effective in image denoise. Furthermore, this proposed system using a camera and a range sensor is very low price since the previous system can be used without reconstruction.

The Effect of Deposition Rate on In-Situ Intrinsic Stress Behavior in Cu and Ag Thin Films (증착 속도 변화에 따른 구리와 은 박막의 실시간 고유응력 거동)

  • Ryu, Sang;Lee, Kyungchun;Ki, Youngman
    • Korean Journal of Metals and Materials
    • /
    • v.46 no.5
    • /
    • pp.283-288
    • /
    • 2008
  • We observed the in-situ stress behavior of Cu and Ag thin films during deposition using a thermal evaporation method. Multi-beam curvature measurement system was used to monitor the evolution of in-situ stress in Cu and Ag thin films on 100 Si(100) substrates. The measured curvature was converted to film stress using Stoney formula. To investigate the effects of the deposition rates on the stress evolution in Cu and Ag thin films, Cu and Ag films were deposited at rates ranging from 0.1 to $3.0{\AA}/s$ for Cu and from 0.5 to $4.0{\AA}/s$ for Ag. Both Cu and Ag films showed a unique three stress stages, such as 'initial compressive', 'a tensile maximum' and followed by 'incremental compressive' stress. For both Cu and Ag films, there is no remarkable effect of deposition rate on the thickness and average stress at the tensile maximum. There is, however, a definite decrease in the incremental compressive stress with increasing deposition rate.

Comparison of Subjective and Objective Sleep Quality in Subjects with and without Hyper-kyphosis

  • Kim, Jun-hee;Hwang, Ui-jae;Choi, Sil-ah;Jung, Sung-hoon
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.5
    • /
    • pp.272-277
    • /
    • 2022
  • Purpose: This study compared the subjective and objective sleep quality between subjects with and without thoracic hyper-kyphosis. Methods: Forty participants were divided into a hyper-kyphosis (n=17) and normal group (n=17) by thoracic spinal angle measurement. The subjective sleep quality was measured using PSQI, a self-report, and objective sleep quality was measured using an actigraphy that measures time according to sleep patterns. Results: The PSQI scores of subjects with thoracic hyper-kyphosis were significantly higher than those with normal thoracic curvature (p=0.013). The total sleep time and real sleep time were less in subjects with hyper-kyphosis than in normal subjects (p=0.006; p=0.029). The light sleep time was less in subjects with excessive spondylolisthesis than in normal subjects (p=0.010). Light sleep time was less in those with hyper-kyphosis, but deep sleep time was similar to the subjects with a normal thoracic curvature (p=0.003; p=0.140). Conclusion: Subjects with thoracic hyper-kyphosis had a decrease in subjective sleep quality, such as sleep discomfort, and objective sleep quality, such as a decrease in sleep time compared to normal subjects.

Forces Prediction by Indirect Force Measurement and Pseudo-inverse Technique (간접 힘 측정 방법과 가상 역행렬을 이용한 힘 예측)

  • Ahn, Byoung-Ha;Shim, Jae-Sool
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.6
    • /
    • pp.43-50
    • /
    • 2002
  • In the design of structure, the forces acting on tai structure are key parameter fur noise and vibration control. However, in the complex structure, the forces at the injection point on the structure cannot be measured directly. So, it is necessary to find out Indirect force evaluation method. In this paper, forces have been measured with In-situ vibration responses and system information. And, three existing techniques of indirect force measurement, vita. direct inverse. principal component analysis and regularization have been compared. This paper shows that multi-vibration responses are essential for talc precise estimation of the forces. To check these conditions, rotary compressor is adopted as test sample, because it is very difficult to measure the injection forces from internal excitation to shell. It alas also been obtained that relatively higher force is transmitted through three welding paths to the compressor shell. It shows a good agreement between direct and indirect force evaluation with curvature shell and plate.

The Lens Design Technique of High Precision Laser Range Finder (고정밀 레이저 거리계용 렌즈 설계 기법)

  • Bae, Young-Chul;Cho, Eui-Joo;Lee, Hyen-Jae;Kim, Sung-Hyen;Kim, Hyeon-Woo
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.2
    • /
    • pp.187-193
    • /
    • 2009
  • A lens which is one of cores for the high precision laser range finder is utilized to compute the distance by measuring the phase displacement. In order to measure the phase displacement, we transmit the optical signal from the laser diode to a target and receive the reflected laser light from the target. In this paper, we propose new lens design technique to solve the problem due to the inconsistent curvature of the lens, which consistently collects optical signals and performs the transmission and reception of the optical data, and test the implementation of the laser range finder based on the proposed technique. Since the proposed laser range finder has low error rate comparing to the conventional techniques, it may be apply to the high precision distance measurement.

  • PDF