• Title/Summary/Keyword: Curtain flow

Search Result 96, Processing Time 0.021 seconds

A Study on the Greenhouse Water Curtain System: Heat Transfer Characteristics

  • 손원명;한길영
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.32 no.E
    • /
    • pp.80-87
    • /
    • 1990
  • Energy balance equations Were developed to describe the heat transfer mechanisms in a double layer plastic greenhouse with a water curtain system. Heat transfer variables were determined by using various temperature data measured in a conventional prototype semicircular cross-section greenhouse over a range of water temperatures and water flow rates. The heat transfer coefficient between flowing water and greenhouse air was independent of water flow rates. But the heat transfer coefficient between water surface and the stagnant air space within the double plastic layer was dependent on water flow rates. Substituting the heat transfer coefficients, determined from the energy balance equations in the heat transfer equations, demonstrated various relationships among ambient air temperature, greenhouse air temperature, water temperature, and water flow rates. The heating benefits were linearly related to not only the inside and outside air temperatures but also to the water temperature. The energy conservation effects of the water curtain system were found even initial water temperatures were considerably lower than the greenhouse setting temperatures. Sensitivity analysis for heat transfer coefficients demonstrated that the heat transfer coefficient between greenhouse air and the stagnant air within the plastic layers was the most significant coefficient in the estimation of heating effects.

  • PDF

Establishment of Numerical Model for Groundwater Flow (Water Curtain) Analysis around Underground Caverns (지하공동 주변의 지하수 흐름(수막)해석을 위한 수치모형의 확립)

  • Jeong, Il-Mun;Jo, Won-Cheol;Bae, Deok-Hyo
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.1
    • /
    • pp.63-73
    • /
    • 1997
  • Finite element model is established for the simulation of groundwater flow due to water curtain around underground oil storage Choleski decomposition method. The symmetric global conductance matrix is solved by vector storage Choleski decomposition method. The model is verified through comparison with the results of electric analogy. For the application of this model to real site, the finite element meshes are constructed according to representative vertical cross and longitudinal sections. In cross-sectional analysis, potential and flow distributions are compared based on the cavern pressure and horizontal water curtain. For longitudinal section, effects between nearly located caverns with or without vertical water curtain are analyzed. These results prove that the established model can be used as a tool for flow analysis around underground caverns.

  • PDF

Isolation Performance of the Single-Sided air Curtain in Air-Conditioned Space (공조공간에서 수평토출형 에어커튼의 차단 성능)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.11
    • /
    • pp.806-812
    • /
    • 2012
  • Air curtains are widely used in commercial and public buildings to replace solid doors where traffic of people is predicted. At doorways where the solid door is open continuously or intermittently, an air curtain may be installed in order to reduce the flow of heat and moisture from the enclosed space to the outside. The purpose of this paper is to predict isolation performance of the single-sided air curtain when the wind is blowing. For the study, a numerical simulation is used to find the influence of various jet velocities on the efficiency of the single-sided air curtain device which is mounted at the side of the doorway. The isolation performance of the single-sided air curtain is evaluated by sealing efficiency which provides the assessment of the infiltration air ratio. According to the result of this study, the single-sided air curtain has lower sealing efficiency than downward-blowing air curtain. Therefore, for energy conservation in heating space, the single-sided air curtain is not recommended because of its low effectiveness.

A curtain traveling pluviator to reconstitute large scale sand specimens

  • Kazemi, Majid;Bolouri, Jafar B.
    • Geomechanics and Engineering
    • /
    • v.14 no.2
    • /
    • pp.131-139
    • /
    • 2018
  • The preparation of repeatable and uniformly reconstituted soil specimens up to the specified conditions is an essential requirement for the laboratory tests. In this study for large samples replication, the simultaneous usage of the traveling pluviation and curtain raining technique is used to develop a new method, called the curtain travelling pluviator (CTP). This simple and cost effective system is based on the air pluviation approach, whilst reducing the sample production time, can reproduce uniform samples with relative densities ranging from 25% to 96%. In order to investigate the resulting suitability and uniformity from the proposed method, a series of tests is performed. The effect of curtain traveling velocity, curtain width, drop height, and flow rate on the parameters of the sample is thoroughly investigated. Increase in the curtain velocity and drop height leads to the increase in relative density for the sand specimen. Increase in curtain width typically resulted in the reduction of relative density. Test results reveal that the terminal drop height for the sand specimen in this study is more than 500 mm. Relative density contour lines are presented that can be utilized in optimizing the drop height and curtain width parameters. Sample uniformity in the vertical and horizontal orientation is investigated through the sampling containers. Increasing relative density tends to result in the higher sample repeatability and uniformity.

The Study on the Bi-directional Ejection Air Curtain System for Blocking Smoke Diffusion in case of Tunnel Fire (터널 화재시 연기확산 차단을 위한 양방향 토출 에어커튼 시스템에 대한 연구)

  • Yang, Sang-Ho;Choi, Young-Seok;Kim, Jung-Yup;Kim, Nam-Goo;Kim, Kyung-Yup
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.5
    • /
    • pp.43-53
    • /
    • 2014
  • This paper presents a the study on air curtain system of top and bottom bi-directional jet air discharge for blocking the spread of smoke in case of tunnel fire. The five kinds different air curtains of A, B, C, D, and E of models for various performance tested after manufactured. A results of the various performance test obtained the best efficiency from E model air curtain. And optimize the injection angle of the air curtain nozzle through the three-dimensional computational fluid dynamics (CFD) analysis and analyzed the effects of external pressure of tunnel. and also single factor design have been applied. At present, our attention is focused on the velocity distribution(flow width and flow position) of 1.5m on the ground in tunnel. Also, analyzed the influence of draft in the tunnel. Detailed effects of discharge angle of air curtain and velocity at nozzle exit are discussed.

Exhaust Performance of a Kitchen Hood System with a Supply Air Slot on a Kitchen Table (조리대에 급기구를 가진 주방 레인지후드의 배기 성능)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.12
    • /
    • pp.489-494
    • /
    • 2016
  • There have been many cases when an air curtain installed in the apartment could not remove the gases well, such as carbon dioxide and particles like as smoke, oils, and vapors generated during cooking to disperse pollutants into the room. This study used a numerical analysis to show how the pollutant-removing performance of the range hood is changed when the air curtain is installed front of the kitchen table. The result of this study was that when the air amount supplied by an air curtain through the slot was about 50% of the exhaust amount, the capturing efficiency of the range hood for pollutants increased 90% more than without an air curtain. Even when the amount of supplied air was small, the capturing efficiency improved markedly with the use of an upward air curtain. In case that the air flow rate of the slot was greater than 60%, the capturing efficiency decreased.

Experimental Study on Extinction Behavior in Buoyancy-minimized Counterflow Diffusion Flame (부력 효과의 최소화를 통한 대향류 확산화염 소화거동에 관한 실험적 연구)

  • Chung, Yong Ho;Park, Jeong;Kwon, Oh Boong;Yun, Jin-Han;Kee, Sang-In;Kim, Young Ju
    • Journal of the Korean Society of Combustion
    • /
    • v.17 no.4
    • /
    • pp.38-43
    • /
    • 2012
  • Experimental study was conducted to elucidate flame extinction phenomena in counterflow flame. Using a curtain helium flow significantly reduced buoyancy such that the flame can be positioned at the center between the upper and lower nozzles even at the velocity ratio of 1.0. The curves of critical diluent mole fraction versus global strain rate have C-shapes. The flame oscillation was observed prior to low strain rate flame extinction at both flame conditions with and without minimizing buoyancy force. The results show that, at low strain rate flame, the self-excitation frequency with the order of 1.0 Hz in the case of utilizing pure helium gradually decreases in increase of $N_2$ mole fraction in the curtain flow, meaning that buoyancy suppresses the self-excitation of the outer edge flame.

Behavior of the Edge Flame on Flame Extinction in Buoyancy minimized Methane-Air Non-premixed Counter Triple Co-flow Flames (부력을 최소화한 대향류 삼축 메탄-공기 비예혼합 화염 소화에서 에지화염의 거동)

  • Park, Jin Wook;Park, Jeong;Yun, Jin-Han;Keel, Sang-In
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.81-84
    • /
    • 2014
  • A Experimental study on flame extinction behavior was investigated using He curtain flow with counter triple co-flow burner. Buoyancy force was suppressed up to a microgravity level of $10^{-2}-10^{-3}g$ by using He curtain flow. The stability maps were provided with a functional dependency of diluent mole fraction and global strain rate to clarify the differences in flame extinction behavior. The flame extinction curves had C-shapes at various global strain rates. The oscillation and extinction modes were different each other in terms of the global strain rate, and the flames extinction modes could be classified into five modes such as (I) and (II): an extinction through the shrinkage of the outmost edge flame forward the flame center after self-excitation and without self-excitation, respectively, (III): an extinction through rapid advancement of a flame hole while the outmost edge flame is stationary, (IV): self-excitation occurs in the outermost edge flame and the center edge flame and then a donut shaped flame is formed and/or the flame is entirely extinguished, (V): shrinkage of the outermost edge flame without self-excitation followed by shrinkage or survival of the center flame. These oscillation and extinction modes could be identified well to the behavior of edge flame. The result also showed that the edge flame was influenced significantly by the conductive heat losses to the flame center or ambient He curtain flow.

  • PDF

Exhaust Characteristics of Kitchen Hood System with Inclined Air Curtain (에어커튼형 주방 레인지후드의 배기 특성)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.594-599
    • /
    • 2014
  • There have been many cases that the air curtain installed in the apartment can not well remove the gases such as carbon dioxide and particles such as smokes, oils and vapors generated during the cooking to disperse the pollutants into the room. This study uses the numerical analysis to show how the pollutant-removing performance of the range hood is changed when the air curtain is installed on the range hood of kitchen. As a result of the study, it turned out that, when the air amount supplied by air curtain through the slot was about 60% of exhaust amount, the capturing efficiency of range hood for pollutants increased by 70~80% more than the case without the air curtain. Even when the exhaust amount was small, the capturing efficiency was improved a lot with the use of air curtain. In case that the air flow velocity of slot was greater than 2 m/s, the capturing efficiency turned out to decrease.

A Study on Transition of Shrinking Flame Disk to Flame Hole at Low Strain Rate Counterflow Diffusion Flames (저신장율 대향류확산화염에서 소화하는 화염디스크로부터 화염구멍으로 천이에 관한 연구)

  • Park, Dea-Geun;Park, Jeong;Yun, Jin-Han;Keel, Sang-In
    • Journal of the Korean Society of Combustion
    • /
    • v.13 no.4
    • /
    • pp.16-25
    • /
    • 2008
  • Experiments have been conducted to clarify impacts of curtain flow and velocity ratio on low strain rate flame extinction, and to further display transition of shrinking flame disk to flame-hole. Critical mole fractions at flame extinction are examined in terms of velocity ratio, global strain rate, and nitrogen curtain flow rate. It is shown that multi-dimensional effects at low strain rate flames through global strain rate, velocity ratio, and curtain flowrate dominantly contribute to flame extinction and transition of shrinking flame disk to flame hole. Our concerns are particularly focused on the dynamic behavior of an edge flame in shrinking flame disk.

  • PDF