• Title/Summary/Keyword: Current-Program

Search Result 4,093, Processing Time 0.036 seconds

For the Improvement of Nosocomial Infection Control in Korea (우리나라 병원감염관리 활성화를 위한 모형 개발)

  • Lee, Sung-Eun
    • Research in Community and Public Health Nursing
    • /
    • v.8 no.2
    • /
    • pp.314-326
    • /
    • 1997
  • In Korea, the nosocomial infection control program is not well developed. This situation is created by a lack of interest from medical personnel and the medical payment system. This study identifies current problems and develops a model for nosocomial infection control. The studies of Lee & Kim(1995), Lee (1993) and SENIC project model were used to construct this model. 1. The problems of nosocomial infection control were identified as the following: dis approval by hospital authorities, lack of sources for program direction, lack of overall structure and function in the program, inadequate direct action, lack of education and training, and so on. 2. The problems are reorganized according to the 5 elements of system theory. 3. As a result, the new nosocomial infection control model was developed. The inputs of the model were the elements, resources and boundaries of nosocomial infection. With the new model, each hospital can evaluate their current programs and plan a new program for the better control of nosocomial infection.

  • PDF

Development of Computer Program for Calculation of Induced Lightning Voltages on Overhead Multiconductor Systems (다상 가공선로의 유도뢰 전압 해석을 위한 프로그램 개발)

  • Lee, Yong-Han;Park, Dong-Wook;Lim, Yong Hyeok
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.418-421
    • /
    • 1989
  • A program for numerical analysis of induced lightning surge is developed. The program first converts simultaneous differential equations into simultaneous difference equations for line sections without transition points, and calculates the line voltage and current by solving a determinant. It, then, calculates the line voltage and current at transition points by applying kirhhoffs law. This program is potentially useful in a wide range of applications for investigating the effect on distribution lines of lightning protection equipment such as lightning arresters and overhead ground wires.

  • PDF

Tuberculosis Management of Private Health Care Institution : Current Situation and Task (민간 의료기관 결핵관리의 오늘과 내일)

  • Park, Ki-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.6
    • /
    • pp.579-589
    • /
    • 2002
  • Since the inception of the National Tuberculosis Control Program in 1962, the incidence of tuberculosis and its associated mortality has declined dramatically due to effective anti-tuberculosis drugs and a systematic control program. The prevalence of radiographically active tuberculosis has fallen from 5.1% in 1965 to 1.0% in 1995. However, tuberculosis is still a major problem, as the mortality rate is still higher compared to other developed countries. Furthermore, tuberculosis is currently re-emerging in HIV/AIDS epidemic countries. In order to lower the tuberculosis death rate to the levels of developed countries, the tuberculosis control efforts in private healthcare institutions and the national tuberculosis control program in the public sector, need to work together more effectively and efficiently. In this paper, the quthor reviewed the current situation regarding tuberculosis management in private healthcare institutions of Korea based on the literature and the National Health Insurance Claim data, and the future tasks of tuberculosis management are suggested.

Analysis of Induction Heating System using FEM (유한요소법을 이용한 유도가열 시스템의 해석)

  • 임광섭;김우균;오수익
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.03a
    • /
    • pp.125-129
    • /
    • 1997
  • Induction is a method of heating electrically conductive materials such as metals. It is commonly used in process heating prior to metalworking and in heating, welding, and melting. The number of industrial and consumer items which undergo induction heating during some stage of their production is very large and rapidly expanding. So a program to analyze the induction heating system was developed through the research. This thesis contains the procedure for developing the program. Both eddy current and temperature distribution are obtained through the analysis of the induction heating system. The program was developed to calculate 2-dimensional axisymmetric problem. The validity of the program is scrutinized through the comparison between the analytic solution and the numerical solution.

  • PDF

Development of Lightning Parameter Analysis Program and Analysis Result of LPATS Lightning Waveforms (낙뢰분석 프로그램 개발과 이를 이용한 뇌격위치표정시스템의 낙뢰파형 분석결과)

  • Woo, Jung-Wook;Shim, Eung-Bo
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1571-1573
    • /
    • 1998
  • To study the basic research of the lightning parameter for power system operation. LPATS(Lightning Position and Tracking System) has been introduced since 1995 in KEPCO. We have developed the lightning parameter analysis program. We obtained the various statistical distribution of lightning current parameters from 1995 by this program. In this paper, we describe LPATS system configuration. the algorithm of the program and the statistical distribution of lightning current parameters from 1996 to 1997.

  • PDF

A Model of University Reform in a Developing Country: The Brain Korea 21 Program

  • Seol, Sung-Soo
    • Asian Journal of Innovation and Policy
    • /
    • v.1 no.1
    • /
    • pp.31-49
    • /
    • 2012
  • This paper is a review of a 13-year-old policy for university reform in Korea, the Brain Korea 21 Program, based on current theoretical frameworks. Current theoretical frameworks are classified into three groups: micro and macro perspectives on universities and discussion on world-class universities. The overall purpose of BK21 is to bring up high-level scholarship through manpower and achieve several targets of university reform. The program can be evaluated as a success in terms of following a research university model but not the entrepreneurial university model. However, the fact that a 13-year old policy developed under a research university model had features of the entrepreneurial university shows the direction of change that the research university is currently undergoing.

An Efficient Program Slicing Algorithm using Dynamic Control Information (동적 제어 정보를 이용한 효율적인 프로그램 슬라이싱 알고리즘)

  • 박순형;정은이;박만곤
    • Journal of Korea Multimedia Society
    • /
    • v.3 no.1
    • /
    • pp.92-100
    • /
    • 2000
  • For the operation of the practical software systems, the development of new software, extension and modification phases of current software are successively needed through the new requirements added and their errors debugging detected. We need to understand current program exactly during a working serial jobs. When we'd like to extract the statements which influence the variable of specific statement of program, we generally analyze the program behavior through execution trace of program for the input values. It is important to compute dynamic program slice related to all statements that actually affect the value of a variable occurrence for a given program input and to develop techniques of its implementation. But traditional dynamic slicing techniques are inconvenient to make program execution history at the beginning implementation. In this paper, we propose a new improved algorithm which can produce program slice by use of dynamic control information and program slicing techniques except execution history file. Also we can find that the proposed program slicing approach is more efficient than the traditional program slicing algorithm on the practical testing environment.

  • PDF

The Comparison of the Current Unblance Factor According to the Cable Array Method using PSCAD/EMTDC and FEA (PSCAD/EMTDC와 FEA를 이용한 케이블 배열 방법에 따른 전류 불균형률의 비교)

  • Shin, Ho-Jeon;Kim, Ji-Ho;Kang, Gab-Suk;Kim, Jae-Chul;Lee, Hyang-Beom
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.2
    • /
    • pp.72-78
    • /
    • 2013
  • In this study, samples from the site where there occurred unbalanced current when cable routing were analyzed, and the simulation program for electric power system analysis, PSCAD/EMTDC, was used to calculate the current unbalance on cable routing. Based on electromagnetic finite element analysis(FEA), electromagnetic parameters enabled the interlocking with COMSOL for the calculation of allowable current ampacity and magnetic filed distribution. This then led to modeling unbalanced current between common modes using the unbalanced current analysis program, thereby comparing and discussing the results from both. The analyzed model is a common mode 2 parallel circuit, which is a basic model for cable routing, and by arranging cables in various ways, the arrangement with the least current unbalance was suggested, which would, in the future, prevent earth faults and extend life for the whole cable.

The Influence of Frequency on Wayside Transmitter of ATP System upon Reinforcing Bars in Concrete Slab Track (콘크리트 슬래브궤도에서 ATP시스템 지상자의 주파수가 철근에 미치는 영향)

  • Kim, Min-Seok;Lee, Jong-Woo;Ko, Jun-Seog
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.691-706
    • /
    • 2008
  • ATP(Automatic Train Protection) system in railway signaling system is the important one grasping the position and velocity of a train. The wayside transmitter of ATP system is installed between rails. In concrete slab track, the signal current using wayside transmitter of ATP system is influenced by reinforcing bars. The magnetic coupling between reinforcing bars and wayside transmitter of ATP system as a filter makes an input current distorted. So, it makes an alternating current signal with a desirable size not transmit to on-board system of a train. Way to decrease the distortion of an input current signal frequency is to avoid maximum induction current frequency. And the induction phenomenon between reinforcing bars insulated and wayside transmitter of ATP system does not occur. In this paper, we represent the model about wayside transmitter of ATP system and reinforcing bars on the concrete slab tracks, and calculated the parameters demanded for the model. Also, we demonstrated it through the Maxwell program. Furthermore, we calculated impedance on wayside transmitter used in KVB system and ERTMS/ETCS system which are a kind of ATP system, frequency response of induction current, using the Matlab, and demonstrated the validity of it, using the PSpice program.

  • PDF

A Study on the Calculation of Transmission Current-Carrying Capacity by Horizontal Arrangement Type in the Installation Methods of 154kV XLPE 600㎟ Power Cable Buried Ducts in Ground (154kV XLPE 600㎟ 지중관로 수평배열 형태별 허용전류용량 산정에 관한 연구)

  • Kim, Se-Dong;Yoo, Sang-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.53-58
    • /
    • 2016
  • The underground transmission lines which have been built to expand the suppling facilities will be continuously accompanying with high growth of the increase of power demand in the metropolitan area in recent years. So, it is necessary to maximize the ability and reliability of power supply with the current-carrying capability of the underground transmission lines. Design criteria of KEPCO is to be presented and used frequently. But it has to be studied about the installation methods of power cable buried in ground. In this study, we used the program for calculating the current-carrying capability of underground transmission power cables. We estimated the maximum permissible current values by the horizontal arrangement in the installation methods of power cable(154kV XLPE $600mm^2$) buried ducts in ground. To see the general tendency of the analysis, we researched a statistical analysis with such parameters as the maximum permissible current values. Through the regression analysis, we analyze the most highly values of the maximum permissible current on the Ra type duct arrangement.