• 제목/요약/키워드: Current-Drive Mode

검색결과 171건 처리시간 0.023초

스피커의 특성을 고려한 음향 전력 증폭기 구동 방식의 비교: 전압 구동 방식과 전류 구동 방식 (Comparison of the Driving Modes of an Audio Power Amplifier Considering the Characteristics of the Loudspeaker: Voltage Drive vs. Current Drive)

  • 은창수;이유칠
    • 한국멀티미디어학회논문지
    • /
    • 제20권9호
    • /
    • pp.1551-1558
    • /
    • 2017
  • Audio power amplifiers have been designed based on the premise that the impedance of loudspeakers is fixed at nominal 4 ohms or 8 ohms. However, it is known that the impedance varies with frequency and takes on the nominal value at some limited frequencies. The principle of the loudspeaker operation reveals that the sound pressure produced by the loudspeaker is proportional to the current flowing in the voice coil, not the voltage between the two terminals. We take the characteristics of the loudspeaker into account and compare the frequency responses of the loudspeaker in voltage-drive mode and current-drive mode via computer simulations, to conclude that the audio amplifier drive mode should be re-considered in an effort to improve the sound quality.

DC Motor Drive with Circuit Balancing Technique to Reduce Common Mode Conducted Noise

  • Jintanamaneerat, Jintanai;Srisawang, Arnon;Prempraneerach, Yothin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1881-1884
    • /
    • 2003
  • In some requirements of dc motor drive circuit applications are high quality output with generation of low internal conducted EMI. However the conventional dc motor drive circuits have been usually using unbalanced circuit which generates the high conducted EMI to the frame ground. This paper presents a balanced dc motor drive circuit which is effective way to reduce the common-mode noise. The circuit balancing is to make the noise pick up or occurring in both conductor lines, signal path and return path is equal in amplitude and opposite phase so that it will cancel out in the frame ground. The common-mode conducted noise reduction of this proposed dc motor drive is confirmed by experimental results.

  • PDF

입력 신호의 전치 보상을 이용한 D 급 음향 전력 증폭기의 스피커 전류 구동 방법 (Method for Current-Driving of the Loudspeakers with Class D Audio Power Amplifiers Using Input Signal Pre-Compensation)

  • 은창수;이유칠
    • 한국멀티미디어학회논문지
    • /
    • 제21권9호
    • /
    • pp.1068-1075
    • /
    • 2018
  • We propose a method for driving loudspeakers from class D audio power amplifiers in current mode, instead of in conventional voltage mode, which was impossible with the feedback circuitry. Unlike analog audio amplifiers, Class D audio power amplifiers have signal delay between the input and output signals, which makes it difficult to apply the feedback circuitry for current-mode driving. The idea of the pre-distortion scheme used for the compensation of the non-linearity of RF power amplifiers is adapted to remedy the impedance variation effect of the loudspeakers for current driving. The method uses the speaker model for the pre-distorter to compensate for the speaker impedance variation with frequency. The simulation and test results confirms the validity of the proposed method.

Three-Phase Common-Mode Active EMI Filters for Induction Motor Drive Applications

  • Tarateeraseth, Vuttipon
    • Journal of Power Electronics
    • /
    • 제18권3호
    • /
    • pp.871-878
    • /
    • 2018
  • In this paper, the conducted EMI reduction performances of active feed-forward current-sensing current-actuation (CSCA) and voltage-sensing current-actuation (VSCA) filters for a three-phase induction motor drive system are evaluated by experiments. For comparison purposes, the conducted EMI (CM emission, DM emission and total emission) of a three-phase induction motor drive with a conventional CM choke, a conventional CM choke in series with an active VSCA filter, and an active CSCA filter (where the CM choke was modified and used as a sensing current transformer) were compared to the case of a system without any filter inserted. Experimental results show that the active CSCA and VSCA filters can improve the CM reduction performance of the conventional CM choke by about 5 dB especially at low-frequencies. However, for DM comparisons, it shows that there is no different between cases with and without filters inserted.

Design of Sliding Mode Observer for Switched Reluctance Motor

  • Hwang, Young-Seong;Kim, Jin-Young;Choi, Jae-Dong;Kim, Kab-Dong;Seong, Se-Jin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.434-437
    • /
    • 2001
  • Generally, a switched reluctance motor (SRM) drive requires a rotor position sensor for commutation and current control. However, this position sensor causes an increase for cost and size of motor drive. In this paper, a sliding mode observer is proposed for indirect position sensing in SRM drive. This estimated rotor position is used for the electric commutation of the machine phases. The paper includes a design approach and operating performance based on the proposed sliding mode observer.

  • PDF

Current Mode Integrated Control Technique for Z-Source Inverter Fed Induction Motor Drives

  • Thangaprakash, Sengodan;Krishnan, Ammasai
    • Journal of Power Electronics
    • /
    • 제10권3호
    • /
    • pp.285-292
    • /
    • 2010
  • This paper presents a current mode integrated control technique (CM-ICT) using a modified voltage space vector modulation (MSVM) for Z-source inverter (ZSI) fed induction motor drives. MSVM provides a better DC voltage boost in the dc-link, a wide range of AC output voltage controllability and a better line harmonic profile. In a voltage mode ICT (VM-ICT), the outer voltage feedback loop alone is designed and it enforces the desired line voltage to the motor drive. An integrated control technique (ICT), with an inner current feedback loop is proposed in this paper for the purpose of line current limiting and soft operation of the drive. The current command generated by the PI controller and limiter in the outer voltage feedback loop, is compared with the actual line current, and the error is processed through the PI controller and a limiter. This limiter ensures that, the voltage control signal to the Z-source inverter is constrained to a safe level. The rise and fall of the control signal voltage are made to be gradual, so as to protect the induction motor drive and the Z-source inverter from transients. The single stage controller arrangement of the proposed CM-ICT offers easier compensation. Analysis, Matlab/Simulink simulations, and experimental results have been presented to validate the proposed technique.

Common-Mode Current Cancellation Scheme of Half-Bridge Switch-Mode Converter for DC Motor Drive

  • Srisawang, Arnon;Panaudomsup, Sumit;Prempraneerach, Yothin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1876-1879
    • /
    • 2003
  • Due to the conventional half-bridge switch-mode converters for dc motor drive have been usually using unbalanced circuit topologies which generate common-mode currents through parasitic capacitors distributed between the ground and the dc motor frame such as the heat-sink of switching devices or the frame of the dc motor. This paper describes methods that cancel common-mode current generated in half-bridge switch-mode converters by using circuit balancing technique. The circuit balancing is to make the noise pickup or occurring in both conductor lines, signal and return pathes, is equal in amplitude and opposite in phase so that it will be canceled out in the ground plane. The common-mode current cancellation in the proposed converter is confirmed by experimental results.

  • PDF

A Fuzzy Predictive Sliding Mode Control for High Performance Induction Motor Position Drives

  • Bayoumi E.H.E.;Nashed M.N.F.
    • Journal of Power Electronics
    • /
    • 제5권1호
    • /
    • pp.20-28
    • /
    • 2005
  • This paper presents a fuzzy predictive sliding mode control for high performance induction motor position drives. A new simplified inner-loop sliding-mode current control scheme based on a nonlinear mathematical model of an induction motor is introduced. Novel predictive fuzzy logic PI and PID controllers are used in speed and position loops, respectively. Sliding-mode current controllers and fuzzy predictive logic controllers are designed based on indirect vector control. The overall system performance is examined under different dynamic operating conditions. The performance of the drive system is robust and stable, and insensitive to parameters and operating condition variations even though non-exact system parameters are used in the implementation of the proposed controllers.

파워 LED 구동을 위한 정전류 제어기 설계 (A Constant Current Controller Design for Power LED Drive)

  • 김응석;김철진
    • 전기학회논문지
    • /
    • 제59권3호
    • /
    • pp.555-561
    • /
    • 2010
  • In this paper, the constant current controller is designed to regulate the driving current of a power LED. The controller design model of the power LED including its driving circuit is proposed to design the constant current controller. A buck converter is also introduced to drive the power LED. The PI-based digital controller is implemented to validate the proposed strategy for the power LED driving.

SRM의 4상한 구동을 위한 전류제한 방식 (Current Limit Control for a Four-quadrant Operation of SRM Drive)

  • 안진우;강유정
    • 전력전자학회논문지
    • /
    • 제8권3호
    • /
    • pp.285-291
    • /
    • 2003
  • 스위치드 릴럭턴스 전동기는 고출력, 고효율 및 직권전동기 구동특성 등으로 견인구동용으로 주목받고 있다. 그러나 전동기를 4상한 구동하기 위한 발전영역에서 제어는 쉽지 않다. 본 논문은 전류제한법에 의해 안정된 발전제동이 가능한 제어방식을 제안하였다. 전동기 구동시는 기준전류제한방식과 위상각 제어방식으로 속도제어를 행하고, 발전제동모드에서는 상전류가 발산하지 않는 조건을 산정하여서 이 값을 기준전류로 한 전류제한방식을 채택하였다. 시뮬레이션과 실험에 의해 제안한 방식의 타당성을 확인하였다.