• Title/Summary/Keyword: Current waveform

Search Result 724, Processing Time 0.038 seconds

Leakage Current Waveforms and Spectrum Analysis on Polymer Insulator of EPDM under Salt fog (SALT FOG시 EPDM고분자애자의 누설전류파형과 스펙트럼분석)

  • 박재준;양태규
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.500-504
    • /
    • 2004
  • This research is about the result of leakage current waveform about the situation of surface leakage current and environmental changes(Salt fog, clean fog and rain) by EPDM polymer insulators' amount of salt. The researcher presents the result of changing about fundamental harmonic, 3rd harmonic and 5th harmonic from starting point of supplying power to flashover. In this study, researched environmental affects (clean fog, salt fog and .am) about surface aging of polymer insulators and used frequency spectrum of leakage current waveform to develop the diagnostic technique of surface aging. When amount of salt contents changed, surface aging stage and the degree of aging (distortion factor) about 3rd and 5th harmonir waveform on low frequency harmonic wave. The distortion factor which is harmonic percentage about basic harmonic is important pointer to evaluate the surface condition of polymer insulators.

  • PDF

A Method for Estimating an Instantaneous Phasor Based on a Modified Notch Filter

  • Nam Soon-Ryul;Sohn Jin-Man;Kang Sang-Hee;Park Jong-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.279-286
    • /
    • 2006
  • A method for estimating the instantaneous phasor of a fault current signal is proposed for high-speed distance protection that is immune to a DC-offset. The method uses a modified notch filter in order to eliminate the power frequency component from the fault current signal. Since the output of the modified notch filter is the delayed DC-offset, delay compensation results in the same waveform as the original DC-offset. Subtracting the obtained DC-offset from the fault current signal yields a sinusoidal waveform, which becomes the real part of the instantaneous phasor. The imaginary part of the instantaneous phasor is based on the first difference of the fault current signal. Since a DC-offset also appears in the first difference, the DC-offset is removed trom the first difference using the results of the delay compensation. The performance of the proposed method was evaluated for a-phase to ground faults on a 345kV 100km overhead transmission line. The Electromagnetic Transient Program was utilized to generate fault current signals for different fault locations and fault inception angles. The performance evaluation showed that the proposed method can estimate the instantaneous phasor of a fault current signal with high speed and high accuracy.

Characteristic Analysis of Power Compensation Condenser Considering Voltage Harmonics (전압 고조파를 고려한 역률보상용 콘덴서의 특성 분석)

  • Kim, Jong-Gyeum;Lee, Dong-Ju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.141-145
    • /
    • 2010
  • Most of the industrial loads includes the non-linear load as well as the linear load because there are many kinds of power conversion equipments at the input stage of the load in distribution network. The non-linear load causes the distortion of voltage waveform at PCC because the non-linear load generates the harmonic current. As a result, various voltage harmonics are existed at PCC depending on the current harmonics from the non-linear load. And, a series reactor is generally connected to the power capacitor in series to attenuate the distortion of voltage waveform and to reduce an inrush current of power capacitor. Also, harmonic current of power capacitor is highly dependent on the series reactor because it is operated with the power capacitor as a passive filter against nonlinear loads. Then, these capacitors might be damaged by the excessive voltage and current harmonic components. In this paper, we presented how to select the capacitor and series reactor to meet the requirement of the voltage distortion at PCC and analyzed the voltage, current and capacity rating of the power capacitor by the computer simulation to ensure the safe operation of power capacitor when the voltage harmonics at PCC are existed. Also, the analysis data were compared with the experimental measurements for the verification.

Surge Characteristics Analysis of Three-phase Virtual Chopping at Vacuum Circuit Breaker (진공차단기 3상 동시 차단시의 서지 특성 분석)

  • Kim, Jong-Gyeum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.9
    • /
    • pp.1159-1164
    • /
    • 2018
  • Vacuum circuit breakers(VCB) are widely used for current interruption of high-voltage inductive loads such as induction motors. This VCB can be chopped off before the current zero due to its high arc-extinguishing capability. One of the outstanding features of VCB is that it can cut off high frequency re-ignition current more than other circuit breakers. If the transient recovery voltage generated in the arc extinguishing is higher than the dielectric strength of the circuit breaker, a re-ignition phenomenon occurs. The surge voltage of the re-ignition is very high in magnitude and the steepness of the waveform is so severe that it can act as a high electrical stress on the winding. If the high frequency current of one phase affects the other two phases when the re-ignition occurs, it may cause a high surge voltage due to the virtual current chopping. If the magnitude of the voltage allowed in the motor winding is high or the waveform level is too severe, it may lead to insulation breakdown. Therefore, it is necessary to reduce the voltage to within a certain range. In this study, we briefly explain the various phenomena at the time of interruption, analyzed the magnitude of the dielectric strength and the transient recovery voltage at the simultaneous three-phase interruption that can give the greatest influence to the inductive load, proposed a method to reduce the impact.

Ramp Waveform Generating Circuit for Improving the Contrast Ratio in AC Plasma Display Panel (AC PDP의 Ramp 파형 개선에 따른 Contrast ratio 향상에 관한 연구)

  • Lee, Sung-Hyun;Kim, Dong-Hyun;Kim, Young-Kee;Heo, Jeong-Eun;Shin, Joong-Hong;Lee, Ho-Jun;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1588-1590
    • /
    • 2001
  • The voltage controlled ramp waveform(VCR) has recently been used in the reset period prior to addressing for plasma display. However, in this paper, the current controlled ramp waveform(CCR) which may prevent the oscillation of gap voltage cause current growth and decrease the background luminance has been suggested. As a result, in case of CCR method, the contrast ratio was about 14% increased compared with VCR method, whereas the addressing and sustainin discharge characteristics of CCR method were same with those of VCR method.

  • PDF

Analysis on the Characteristic of Current Waveform and Welding for SM45C Using FCAW According to Gas Mixture Ratio (FCAW를 이용한 SM45C의 혼합가스비율에 따른 전류파형 및 용접특성 연구)

  • Lee, JongHun;Lim, ByungChul;Park, SangHeup
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.6
    • /
    • pp.618-623
    • /
    • 2014
  • This study, analyzed the waveform and mechanical properties of flux cored arc Welding on SM45C. $CO_2$ 10% + Ar 90% shows the lowest standard deviation and shunt ratio at which the arc was most stable. $CO_2$ 10% + Ar 90% is equal to $CO_2$ 20% + Ar 80%. therefore, $CO_2$ 20% + Ar 80% is the best of mixture gases. The hardness test result for the gas mixture ratio of $CO_2$ 10% + Ar 90% was HV 249.7 which is the highest measured value. According to tensile test results, the tensile strength increased with increasing Ar in the mixture gas. This was because of the inertness of the argon, which does not combine with other elements, causing $CO_2$ to combine with pearlite and ferrite and decreasing the maximum tensile strength. Microstructural examination results show that with increasing Ar, ferrite generation decreases while the mild microstructure increases which influences the hardness.

The Current and Power Waveform Improvement of a $3{\Phi}$ Induction Motor with LC Filter Driven by a Digital Bridge Inverter (디지탈 브리지형 인버터로 구동되는 3상유도전동기의 LC 필터에 의한 전류 및 전력 파형 개선)

  • Chung, J.Y.;Park, J.G.;Kang, C.N.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.553-555
    • /
    • 1996
  • This paper concerns with a method to improve the current and power waveforms of the variable speed $3{\Phi}$ AC motor system driven by the single-pulse PWM, and the current waveforms and $3{\Phi}$ power waveforms are analyzed by FFT under various running conditions. By the performance analysis through the experiments, the following results have been obtained. AC source of pseudo sine waveform can be obtained from the modulated alternating square voltage by means of the well designed LC filter. It is confirmed that current waveforms and $3{\Phi}$ power waveforms can be improved by utilizing the high order low pass LC filter than that of lower order. Especially, current waveforms and $3{\Phi}$ power waveforms tan be much improved at low frequency domain. $3{\Phi}$ power waveforms have a smatter ripple and bigger power by utilizing the high order low pass LC filter than that of lower order. Also, the running condition of $3{\Phi}$ AC motor is good at low frequency domain.

  • PDF

Real-time estimation of arc stability in GMAW process (GMAW 공정에서 아크 안정성의 실시간 측정)

  • 원윤재;부광석;조형석
    • Journal of Welding and Joining
    • /
    • v.8 no.1
    • /
    • pp.31-42
    • /
    • 1990
  • Arc must be stable during welding first of all other factors for obtaining sound weldment, especially in the automation of welding process. Arc stability is somewhat sophisticated phenomenon which is not clearly defined yet. In consumable electrode welding, the voltage and current variation due to metal transfer enables to assess arc stability. Recently, statistical analyses of the voltage and current waveform factors are performed to assess the degress of arc stability which is assessed and controlled by operator's own experience by now. But, considering the increasing need and the trend of automation of welding process, it is necessary to monitor arc stability in real-time. In this sutdy, the modified stability index composed of two voltage and current wvaeform factors (arc time and short circuit time) reduced from four factors (arc time, short circuit time, average arc current and average short circuit current) in Mita's index by the welding electrical circuit modeling is proposed and verified by experiments to be well estimating arc stability in the static sense. Also, the recursive calculation form estimating present arc stability in the dynamic sense is developed for real-time estimation. The results of applying the recursive index during welding show good estimation of arc stability in real-time. Therefore, the results of this study offers the mean for real-time control arc stability.

  • PDF

A Study on Modeling of Short-Circuliting Phenomena and Selection of Current Waveform for Reduction of Spatter in GMAW (가스 메탈 아크 용접에서 단락현상 모델링 및 스패터 감소를 위한 전류파형 선정에 관한 연구)

  • 황주호;문형순;나석주;한광수
    • Journal of Welding and Joining
    • /
    • v.14 no.1
    • /
    • pp.57-67
    • /
    • 1996
  • With an expansion in automation of welding processes, emphasis has been shifted from other welding processes to the GMA welding. However, there is a problem with this process that the spatter occurs very frequently. In GMA welding, there are several types in the way of metal transfer from the electrode wire to the weld pool, which have a close relatonship with the spatter genetration. This study was concerned with the spatter occurring in the short-circuiting transfer. In welding with short-circuiting, the electromagnetic force formed by the welding current facilitatics the rupture of the metal bridge between the wire and workpiece and ensures the normal process of the welding process. However, the spatter can be genetrated from the droplet because of the upward magnetic force, when the droplet contacts with the weld pool. The passage of current through the bridge results in the accumulation of the thermal energy, which causes the bridge to explode in the final stage of short-circuiting, thus forming the spatter. Based on the above phenomena in conjunction with other experimental results published, the physical phenomenon related with the occurrence of spatter was modeled and the current waveform was investigated to reduce the spatter. Finally, the fuzzy rule based method was proposed to predict the time of short-circuiting and arcing in the metal transfer.

  • PDF