• Title/Summary/Keyword: Current transformer

Search Result 1,366, Processing Time 0.029 seconds

D-UPFC Application as the Series Power Device in the Massive Roof-top PVs and Domestic Loads

  • Lee, Kyungsoo
    • Current Photovoltaic Research
    • /
    • v.4 no.4
    • /
    • pp.131-139
    • /
    • 2016
  • This paper shows the series power device in the massive roof-top PVs and domestic loads. D-UPFC as the series power device controls the distribution voltage during voltage rise (or fall) condition. D-UPFC consists of the bi-directional ac-ac converter and the transformer. In order to verify the D-UPFC voltage control, the distribution model is used in the case study. D-UPFC enables the voltage control in the distribution voltage range. Dynamic voltage control from voltage rise and voltage fall conditions is performed. Scaled-down experimental test of the D-UPFC is verified the voltage control and it is well performed without high voltage spikes in the inductive load.

A study on modified algorithm to operating train simulation of AT feeding systems (전기철도 AT급전계통의 열차 운형 모의 해석 알고리즘 연구)

  • Choo, Dong-Woog;Kim, Jae-Chul;Jung, Yong-Chul;Jun, Yong-Ju;Lim, Seong-Jeong
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.449-451
    • /
    • 2001
  • This study presents a study on modified algorithm to operating train simulation of AT feeding systems. In this study equivalent impedance is constructed by $Z_c,\;Z_r,\;Z_f,\;Z_{cr},\;Z_{rf},\;Z_{fc}$. The train current flows through the all auto-transformer corresponding to track impedance. To calculate train voltage from analyzing the railway systems, the algorithm is based on the K. C. L, K. V. L, superposition and circuit separation method. Multi-train's voltages are determined by calculating the catenary voltage at each train's position and adding up these train's voltage drop. Case studies use a field operational data, show that the proposed method is easily applied.

  • PDF

Design of a Bidirectional AC-DC Converter using Charge Pump Power Factor Correction Circuit (전하펌프 역률개선 회로를 적용한 양방향성 AC-DC Converter 설계)

  • Ko, Seok-Cheol;Lim, Sung-Hun;Han, Byoung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.227-230
    • /
    • 2001
  • This paper deals with a bidirectional ac-dc converter used in ups system application. We propose a Voltage-Source-Charge-Pump-Power-Factor-Correction(VS-CPPFC) ac-dc converters. First of all, we propose a charge pump power-factor-correction converter. Secondly, we derive and analyse a unity power factor condition. The proposed topology is based on a half-bridge for the primary and a current-fed push pull for the secondary side of a high frequency isolation transformer. The advantage of bidirectional flow of power achieved by using the same power components is that the circuit is simple and efficient. And the galvanically isolated topology is specially attractive in battery charge/discharge circuits in ups system. We design equivalent model for the steady-state circuit and analyse operation waveforms for each mode. We show that the proposed model can be applied to ups system by simulation processes.

  • PDF

Development of Continuous Monitoring System for Generator Stator Insulations (발전기 고정자 권선 절연상태의 상시 감시 시스템 개발)

  • Shin, Byoung-Chol;Hwang, Don-Ha;Kim, Yong-Joo;Kim, Jeong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2212-2214
    • /
    • 1999
  • In this paper, a novel Generator On-line Diagnosis System (GODS) is proposed. This system monitors the insulation condition of the stator winding by on-line measurements of partial discharge (PD). Sensor, such as SSC (Stator Slot Coupler) and RFCT (Radio Frequency Current Transformer) are used for PD measurement. PD signals are continuously measured and digitized with a high speed A/D converter to build the database of the generator's insulation condition. Also this system can communicate with the central monitoring system via RS-485. This helps more efficient operation and maintenance of the generator.

  • PDF

Analysis of Voltage Sag on Power Distribution System (배전시스템센서의 순간전압강하 분석)

  • Oh, Jung-Hwan;Rim, Seong-Jeong;Yun, Sang-Yun;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.954-957
    • /
    • 1997
  • In this paper, we analyze the voltage sag caused by reclosing on electric power distribution system. When a fault is on the electric system, a reclosing operation brings a voltage sag on the feeders which is supplied with a common substation transformer. By analyzing the fault wave-form measured in the field, it is showed that a voltage sag is in proportion to a fault current. Also, we propose an adaptive reclosing scheme. This scheme changes the number of reclosing as a function of the magnitude of a fault voltage and the fault type. As the proposed scheme is compared with conventional scheme in the side of voltage sag and permanent fault, it is verified that the proposed scheme is more effective than conventional scheme.

  • PDF

Dynamic Characteristics Analysis of Multi-bridge PWM Inverter SSSC (다중브리지 PWM 인버터로 구성된 SSSC의 동특성 분석)

  • 한병문;박덕희;김성남
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.6
    • /
    • pp.296-302
    • /
    • 2001
  • This paper proposes a SSSC based on multi-bridge inverters. The dynamic characteristic of the proposed SSSC was analyzed by EMTP simulation and a scaled hardware model, assuming that the SSSC is inserted in the transmission line of the one-machine-infinite-bus power system. The proposed SSSC has 6 multi-bridge inverters per phase, which generates 13 pulses for each half period of power frequency. The proposed SSSC generates a quasi-sinusoidal output voltage by 90 degree phase shift to the line current. The proposed SSSC does not require the coupling transformer for voltage injection, and has a flexibility in operation voltage by increasing the number of series connection.

  • PDF

Construction of the Measuring System for Magnetic Field Waveform Associated with Lightning Return Strokes. (낙뢰에 의하여 발생되는 자계파형측정 시스템의 구성)

  • Lee, B.H.;Ha, B.C.;Kil, G.S.;Paek, Y.H.;Lee, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1658-1660
    • /
    • 1994
  • This paper describes the measurement system of the magnetic field waveforms generated by lightning return strokes. The frequency bandwidth of magnetic field measurement system is from 270[Hz] to about 2.3 [MHz]. As the application experiment, the magnetic field generated by simple impulse and oscillating impulse currents, which are measured by a current transformer (Tek. AM503), is observed by the trial magnetic field measurement system. The obtained results are agreement with each other. A typical magnetic field waveform associated with lightning return strokes was recorded and presented.

  • PDF

A Lecture Note on PU Method thru Calculation of a Simple DC Circuit and Voltage/Fault Analysis of Industrial Power Systems using Actual Data (PU법에 의한 DC 회로계산 및 실계통 데이터를 이용한 전압강하/고장계산 방법)

  • Lee, Sang-Joong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.45-54
    • /
    • 2014
  • This paper presents a lecture note of pu method for power system analysis. The author tries to help students in class better understand the fundamental of pu calculation using a very simple DC circuit. And a voltage drop calculation by pu method for a distribution system is given to help understand the importance of the vector reference in AC circuit analysis. A short current calculation by pu method for a power system with a generator, transformer and transmission line is also presented to show how pu calculation can be applied to real power systems, in which all the data are the ones currently being used by KEPCO and other industrial sites.

Study of measuring electrical signal for diagnosis of tilting train (TTX) during operation (틸팅열차 운행중 열차 전단을 위한 전기신호 계측 연구)

  • Lim, Jae-Chan;Kim, Jae-Chul;Han, Soung-Ho;Lee, Su-Gil
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.49-52
    • /
    • 2008
  • It's essential to measure electrical signals of Korea tilting train "Hanvit 200" during operation, Because we need to study operation characteristics of new electric "Hanvit 200" and we want to develop diagnosis system of main circuit of Korea tilting train "Hanvit 200". So, we measure electrical signals for developing diagnosis system of "Hanvit 200" during operation. We measure voltage and current of the primary winding of main transformer and analyze then. In result, we know that each operation mode has specific waveform and frequency. In addition, we also measure arc currents and arc voltage and we know that are of each situations has specific waveform of pattern.

  • PDF

Discharge Phenomena of Glass Tube Vacuum under AC Applied Voltage (AC 전압하에서 유리진공관의 방전현상)

  • Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.371-372
    • /
    • 2008
  • In this paper, we experimentally investigated discharge phenomena inside vacuum interrupter at 1 to 20 Torr to simulate the vacuum leakage. We used glass type of vacuum interrupter where the internal pressure and the type of gasses can be varied according to requirement. The experiment is conducted under ac applied voltage and the experimental circuit is constructed to simulate the actual circuit used in cubical type insulated switchgear. We used two types of gases such as air and $SF_6$. The use of glass type vacuum interrupter allowed us to measure discharges occurring in vacuum interrupter optically. We measured and discussed the discharge occurring in both gases with a current transformer and ICCD camera. We also revealed that electromagnetic wave spectra emitted by the discharge have same frequency range for both gasses.

  • PDF