• 제목/요약/키워드: Current source localization

검색결과 25건 처리시간 0.023초

전치 신호처리를 통한 평판에서의 다중 충격의 위치 추적에 관한 연구 (Source Location of Multiple Impacts on the Plate Based on Pre-signal Processing)

  • 문유성;박홍석;이상권;신기홍;이영섭
    • 한국소음진동공학회논문집
    • /
    • 제21권3호
    • /
    • pp.220-226
    • /
    • 2011
  • This paper presents the novel work for source localization of serial multiple impacts in a plate sructure. It is difficult to identify the source of serial multiple impacts with the current source localization techenology(SLT) because of the overlapping of dispersive wave induced by multiple impacts and the reflaction from the edge of the plate. In this paper, the new method is suggested for source localization. The method is developed based on the SLT with pre-signal processing such as some limitation for the selection of three sensors, the frequency range for TFA and impact time interval. Results from numerical simulation and experiment in isotropic plate structure are presented, which show the capability of the proposed method.

MRI와 동시에 측정한 뇌전도 신호로 전류원 국지화를 할 때 경사자계 유발 잡음의 영향 분석 (Effects of Gradient Switching Noise on ECD Source Localization with the EEG Data Simultaneously Recorded with MRI)

  • 이항로;한재용;조민형;임창환;정현교;이수열
    • Investigative Magnetic Resonance Imaging
    • /
    • 제7권2호
    • /
    • pp.108-115
    • /
    • 2003
  • 목적 : MRI를 촬영하면서 동시에 측정한 뇌전도 신호에 가장 크게 영향을 미치는 것은 경사자계 유발 잡음이다. MRI와 동시에 측정한 뇌전도 신호에서 전류원 국지화를 수행할 때, 경사자계 유발 잡음이 미치는 영향을 분석하고자 한다. 대상 및 방법 : 사람의 머리와 유사하게 만든 뇌전도 팬텀과 MR compatible 뇌전도 측정시스템, 그리고 3.0 Tesla MRI 시스템을 실험에 사용하였다. 3.0 Tesla MRI 시스템 안에 전류원이 설치되어 있는 뇌전도 팬텀을 놓고, EPI 촬영을 하는 동안 뇌전도 신호를 측정하였다. 경사자계의 세기와 전류원의 위치를 조절하면서 뇌전도 신호 측정을 하였고, 측정된 뇌전도 신호에 대하여 전류원 국지화를 수행할 때 나타나는 국지화 오차를 평가하였다. 결과 : 경사자계 유발잡음에 의한 국지화 오차는 경사자계의 세기와 전류원의 위치에 따라 변화하는 것을 관찰하였다. 또한 경사자계 유발잡음이 Gaussian 잡음보다 전류원 국지화에 미치는 영향이 큰 것을 관찰하였으며, 경사자계 유발 잡음의 전력이 뇌전도 신호 전력의 $10\%$ 이하일 때는 전류원 국지화에 미치는 영향이 미미함을 관찰하였다. 결론 : 경사자계 유발 잡음 전력을 뇌전도 신호 전력의 $10\%$ 이하로 줄인다면 MRI를 하면서 동시에 측정한 뇌전도 신호로도 전류원 국지화를 할 수 있음을 알 수 있었다.

  • PDF

40 채널 SQUID 시스템을 이용한 뇌자도 측정 (MEG Measurement Using a 40-channel SQUID System)

  • 권혁찬;이용호;김진목;김기웅;박용기
    • Progress in Superconductivity
    • /
    • 제4권1호
    • /
    • pp.19-26
    • /
    • 2002
  • We have earlier developed a 40-channel SQUID system. An important figure of merit of a MEG system is the localization error, within which the underlying current source can be localized. With this system, we investigated the localization error in terms of the standard deviation of the coordinates of the ECDs and the systematic error due to inadequate modeling. To do this, we made localization of single current dipoles from tangential components of auditory evoked fields. Equivalent current dipoles (ECD) at N1m peak were estimated based on a locally fitted spherical conductor model. In addition, we made skull phantom and simulation measurements to investigate the contribution of various errors to the localization error. It was found that the background noise was the main source of the errors that could explain the observed standard deviation. Further, the amount of systematic error, when modeling the head with a spherical conductor, was much less than the standard deviation due to the background noise. We also demonstrated the performance of the system by measuring the evoked fields to grammatical violation in sentence comprehension.

  • PDF

다채널 스퀴드 미분계에서 센서 잡음이 위치추정 오차에 미치는 영향 (Influence of Sensor Noise on the Localization Error in Multichannel SQUID Gradiometer System)

  • 김기웅;이용호;권혁찬;김진목;정용석;강찬석;김인선;박용기;이순걸
    • Progress in Superconductivity
    • /
    • 제5권2호
    • /
    • pp.98-104
    • /
    • 2004
  • We analyzed a noise-sensitivity profile of a specific SQUID sensor system for the localization of brain activity. The location of a neuromagnetic current source is estimated from the recording of spatially distributed SQUID sensors. According to the specific arrangement of the sensors, each site in the source space has different sensitivity, that is, the difference in the lead field vectors. Conversely, channel noises on each sensor will give a different amount of the estimation error to each of the source sites. e.g., a distant source site from the sensor system has a small lead-field vector in magnitude and low sensitivity. However, when we solve the inverse problem from the recorded sensor data, we use the inverse of the lead-field vector that is rather large, which results in an overestimated noise power on the site. Especially, the spatial sensitivity profile of a gradiometer system measuring tangential fields is much more complex than a radial magnetometer system. This is one of the causes to make the solutions of inverse problems unstable on intervening of the sensor noise. In this study, in order to improve the localization accuracy, we calculated the noise-sensitivity profile of our 40-channel planar SQUID gradiometer system, and applied it as a normalization weight factor to the source localization using synthetic aperture magnetometry.

  • PDF

조정 응답 파워 방법과 결합된 generalized cross correlation with phase transform 음원 위치 추정 (Generalized cross correlation with phase transform sound source localization combined with steered response power method)

  • 김영준;오민재;이인성
    • 한국음향학회지
    • /
    • 제36권5호
    • /
    • pp.345-352
    • /
    • 2017
  • 본 논문에서는 잔향과 잡음이 존재하는 실제 환경을 모델링하여 두 개의 마이크로폰을 이용한 음원 위치추정의 정확성을 향상시키는 방법을 제안하였다. 입력신호에 VAD(Voice Activity Detection)를 적용하여 묵음 구간을 제외한 음성 구간만을 사용하였고, 샘플링 주파수의 제한으로 인한 측정 범위를 벗어나는 프레임은 업샘플링(up-sampling)을 통해 지연시간을 다시 추정하였다. 여기서 계산된 도착 지연 시간은 Time-table을 참조해 주변 후보위치의 지연 값들과의 비교로 최대 파워 값을 갖는 지연 시간을 선택하여 음원 위치의 정확도를 높였다. 또한 프레임간의 상관성을 이용하여 연속된 음성 프레임의 경우 큰 추정 차가 발생하는 곳을 찾아 주변 프레임의 평균값으로 대체함으로써 음원의 위치 추정 성능을 향상시켰다.

간질환자 두피뇌파의 발작사이간질모양방전과 배경파 델타영역: 전류원분포의 해부학적 연관성 (Interictal Epileptiform Discharges and Background Delta Frequency Bands in Scalp EEGs of Epileptic Patients: Anatomical Correlation between the Current Source Distributions)

  • 정승욱;권오영;강종수;하은옥;정석원;강규식;강희영;박기종;최낙천;임병훈
    • Annals of Clinical Neurophysiology
    • /
    • 제11권1호
    • /
    • pp.16-23
    • /
    • 2009
  • Background: The intermittent delta activity in electroencephalographies (EEGs) of patients with focal brain lesions has been reported to be a marker of an epileptogenic focus. This study investigated the concordance between the current source distribution (CSD) of the interictal epileptiform discharges (IEDs) and that of the background delta frequency bands (DFBs) of the scalp EEG. Methods: We collected scalp EEGs of 13 patients with focal epilepsy that contained uniregional IEDs and unilateral delta to theta slow waves. We applied a distributed source model using LORETA$^{(R)}$ to determine the CSD of the peak points of the IEDs and the DFBs of the background activity. Results: The CSDs of the DFBs were ipsilateral to the CSDs of the peak point of the averaged IEDs in ten patients, and bilateral with ipsilateral predominance in three patients. In the cases with an ipsilateral CSD of the DFB, 8 of 10 patients had concordance of the CSD localization between the averaged IED and the DFB. In the cases with bilateral CSD of the DFB, 2 of 3 patients had concordance of the CSD localization between the averaged IED and the DFB. Conclusions: The CSD localization and lateralization appear to be concordant between the IEDs and the DFB of background activity in epileptic patients. Therefore, the CSD of the DFB in EEGs with visually observable slow activities may predict those of IEDs.

  • PDF

관심영역 스캐닝기법을 이용한 레이더 펄스 발생원 위치 추정기법 (Source Localization Technique for Radar Pulse Emission by Using Scanning Method of Interest Area)

  • 최경식;김종필;원현권;박재현;김인규
    • 한국항공우주학회지
    • /
    • 제39권9호
    • /
    • pp.889-895
    • /
    • 2011
  • 최신의 항공기는 상대 항공기의 레이더에 검출되지 않기 위해 다양한 방법을 적용하고 있다. 레이더를 통해 감지가 어려운 적기의 존재 유무를 파악하고 적기와의 상대적인 거리 차이와 방위를 추정하기 위해 레이더 경보 수신기(RWR, Radar Warning Receiver)가 이용될 수 있다. 기존의 레이더 경보 수신기는 도달 각(AOA, Angle Of Arrival)을 구하고, 도달 각의 방향성으로 레이더 펄스가 발산된 위치를 추정하였다. 따라서 보다 정확한 위치를 추정하기 위해서 보다 정확한 도달 각을 구하는데 초점을 두었다. 반면 도달 각을 정확하게 구하더라도 레이더 펄스를 발산한 상대 항공기가 빠른 속도로 이동하는 경우 정확한 위치 추정은 어렵다. 본 논문에서는 레이더 펄스가 발산된 정확한 위치를 추정하기 위하여, 초고주파의 레이더 펄스 신호에서 저주파수 신호의 위상지연차를 이용하여, 관심 영역에 대한 스캐닝 기법으로 레이더 펄스가 발산된 위치를 추정하였다.

랜덤 선로상의 광 국재현상에 관한 해석(2) : 시뮬레이션 (Theoretical analysis of the lightwave localization phenomenon on the random transmission line (part 2) : simulation)

  • 최영규
    • 한국광학회지
    • /
    • 제14권4호
    • /
    • pp.434-442
    • /
    • 2003
  • 전파정수가 불규칙하게 존재하는 선로를 설정하고, 선로 상의 파동함수의 해가 국재성을 나타내는 원인과 그 조건에 대하여 확률함수를 이용하여 해석하였다. 랜덤한 매질로는 특성 임피던스가 불규칙하게 변동하는 전송선로를 설정하고, 이 선로 상에서의 전압파나 전류파의 국재현상에 대하여 살펴보았다. 수치해석을 실시한 결과, 랜덤 선로 중에 국재하는 해가 존재하는 것이 확인되었으며, 전류원을 삽입하여 선로를 강제 여진시킨 경우에도 선로 상에 전압파가 국재하는 것을 알 수 있었다. 선로 전체에 손실을 설정한 경우에 대한 해석 결과에서는 국재가 존재하는 위치의 파가 가장 큰 영향을 받는다는 사실에서, 광의 국재는 파동이 반사를 반복하는 것에 의해 나타난다는 것을 알 수 있었다.

An autonomous radiation source detection policy based on deep reinforcement learning with generalized ability in unknown environments

  • Hao Hu;Jiayue Wang;Ai Chen;Yang Liu
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.285-294
    • /
    • 2023
  • Autonomous radiation source detection has long been studied for radiation emergencies. Compared to conventional data-driven or path planning methods, deep reinforcement learning shows a strong capacity in source detection while still lacking the generalized ability to the geometry in unknown environments. In this work, the detection task is decomposed into two subtasks: exploration and localization. A hierarchical control policy (HC) is proposed to perform the subtasks at different stages. The low-level controller learns how to execute the individual subtasks by deep reinforcement learning, and the high-level controller determines which subtasks should be executed at the current stage. In experimental tests under different geometrical conditions, HC achieves the best performance among the autonomous decision policies. The robustness and generalized ability of the hierarchy have been demonstrated.

강박장애에서 LORETA 영상을 이용한 P300 국소원의 통계적 분석 (The P300 Source Localization in the Patients with Obsessive-Compulsive Disorder using the LORETA Imaging and SPM)

  • 박성근;최정석;유소영;이보름;강승석;노규식;하태현;권준수
    • 생물정신의학
    • /
    • 제10권2호
    • /
    • pp.168-176
    • /
    • 2003
  • Objectives:We investigated the characteristics of P300 generators in obsessive-compulsive disorder(OCD) patients by using voxel-based statistical parametric mapping of current density images. Methods:P300 generators, produced by a rare target tone of 1500Hz under a frequent non-target tone of 1,000Hz, were measured in 15 right-handed OCD patients and 15 controls. Low Resolution Electromagnetic Tomography(LORETA), using a realistic head model of the boundary element method based on individual MRI, was applied to the 128-channel EEG. Statistical parametric mapping(SPM) was applied for the statistical analysis. Results:We found that both groups had the mean current density of P300 in the parietal, temporal and prefrontal lobe. There was a trend for decreased current density in the prefrontal area in OCD patients. The statistical comparison showed current density increase in the supraparietal area, a statistically significant longer P300 latency and a trend for reduced P300 amplitude in OCD patients. Conclusion:It suggests that P300 source of both groups exists in multiple brain regions at the same time. And both groups had no statistically significant differences in the current density of P300 except for increased current density in the supraparietal area in OCD patients. But, considering the statistically significant longer P300 latency, a trend for reduced P300 amplitude and relative mean current density reduction in the prefrontal area in OCD patients, this study suggests that the frontal lobe may have a reduced normal inhibitory process in OCD patients.

  • PDF