• 제목/요약/키워드: Current sharing control

검색결과 189건 처리시간 0.024초

Input Series-Output Parallel Connected Converter Configuration for High Voltage Power Conversion Applications

  • Kim, Jung-Won;You, J.S.;Cho, B.H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.201-205
    • /
    • 1998
  • In this paper, the charge control with the input voltage feed forward is proposed for the input series-output parallel connected converter configuration for high voltage power conversion applications. This control scheme accomplishes the output current sharing for the output-parallel connected modules as well as the input voltage sharing for the input-series connected modules for all operating conditions including the transients. It also offers the robustness for the component value mismatches among the modules.

  • PDF

이중 결합 Full-Bridge 방식 직렬 공진형 인버터 (A Double Coupling Full-Bridge Configuration Series Resonant Inverter)

  • 배영호
    • 전력전자학회논문지
    • /
    • 제9권4호
    • /
    • pp.326-333
    • /
    • 2004
  • 본 논문에서는 Power-MOSFET를 통해 L및 C로 링크된 2조의 공진형 Full-bridge 인버터 회로를 다중 결합하여 대용량 전력변환장치의 소자에 인가되는 전압이나 부하전류를 분산 제어하는 기법을 제안하고 있다. 이 방식은 두 조의 인버터가 시분할로 구동되기 때문에 각 인버터의 독립된 출력이 부하단에서 합성되어 전력이 공급된다. 출력제어 기법은 시분할 합성법을 사용하고 이에 따른 인버터의 회로동작 모드를 분석하고 해석하였으며, 시뮬레이션을 통한 이론적 해석결과를 검정하고 이를 실험을 통해 비교 고찰하였다.

무정전전원장치의 병렬운전 제어기법에 관한 연구 (A Study on the Parallel Operation Control Technique of On-line UPS System)

  • 곽철훈;최규하
    • 전력전자학회논문지
    • /
    • 제8권6호
    • /
    • pp.585-592
    • /
    • 2003
  • The parallel operation system of UPS is used to increase reliability of power source at critical load. But parallel UPS system has a few defects, impedance is different from each other and circulating current occurs between UPSs, due to line impedance and parameter variation, though controlled by the same synchronization signal. According to such characteristic of parallel UPS, balanced load-sharing control is the most important technique in parallel UPS operation. In this paper, a novel power deviation compensation algorithm is proposed. it is composed of voltage controller to compensate power deviation that be calculated by using active and reactive current deviation between Inverters on synchronous d-q reference frame.

A Current Sharing Circuit for the Parallel Inverter

  • Lee, Chang-Seok;Kim, Si-Kyung
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.176-181
    • /
    • 1998
  • The parallel inverter is popularly used because of its fault-tolerance capability, high-current outputs at constant voltages and system modularity. The conventional parallel inverter usually employs active and reactive power control of frequency and voltage droop control. However, these approaches have the disadvantages that the response time of parallel inverter control is slow against load and system parameter variation to calculate active, reactive power, frequency and voltage. This paper describes a novel control scheme for power equalization in parallel-connected inverter. The proposed scheme has a fast power balance control response, a simplicity of implementation, and inherent peak current limiting capability since it employees an instantaneous current/voltage control with output voltage and current balance and output voltage regulation. A design procedure for the proposed parallel inverter controller is presented. Furthermore, the proposed control scheme is verified through the experiment in various cases such as the system parameter variation, the control parameter variation and the nonlinear load condition.

  • PDF

커뮤테이션 구간의 토크리플 저감을 위한 SRM의 토크 분배 함수 기법 (Torque Sharing Function of SRM for Torque Ripple Reduction in Commutation Region)

  • 김태형;;이동희;안진우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.148-150
    • /
    • 2007
  • A novel torque sharing function (TSF) is presented. To improve efficiency and to reduce torque ripple in commutation region, only a phase torque under commutation is regulated to produce a uniform torque. And the torque developed by the other phase remains with the previous state under a current limit of the motor and drive. If the minimum change of a phase torque reference can not satisfy the total reference torque, two-phase changing mode is used. Since a phase torque is constant and the other phase torque is changed at each rotor position, total torque error can be reduced within a phase torque error limit. And the total torque error is dependent on the change of phase torque. To consider non-linear torque characteristics and to suppress a tail current at the end of commutation region, the incoming phase current is changed to torque increasing direction, but the outgoing phase current is changed to torque decreasing direction. So, the torque sharing of the outgoing phase and incoming phase can be smoothly changed with a minimum current cross over. The proposed control scheme is verified by some computer simulations and experimental results.

  • PDF

다병렬 직류배전 시스템의 DC전류 드룹 제어를 이용한 서로 다른 3상 AC/DC컨버터의 병렬운전기법 (The Parallel Operation of Each other three phase AC/DC Converter using DC Current Droop Control for Multi-parallel DC Distribution System)

  • 이희준;홍석진;현승욱;강진욱;김한수;원충연
    • 조명전기설비학회논문지
    • /
    • 제29권6호
    • /
    • pp.42-48
    • /
    • 2015
  • DC distribution system is difficult to compose the single-system because of the capacity restriction of power semiconductors. Therefore, DC Distribution system needs parallel operation of AC/DC converters for increase to system capacity. However, this system generates the circulating current. This paper is reducing the circulating current and safely sharing the load using the proposed DC current droop control method when each other 3-phase AC/DC converter connected. This system confirms through the simulation and experiment. Also, when each other converter of parallel operate. it is compared the response characteristics

Static UPS 병렬운전 제어 (The Control of Parallel Operation for Static UPSs)

  • 김동욱;김연풍;신현주;백병산;류승표;민병권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2048-2050
    • /
    • 1998
  • An uninterruptible power supply(UPS) with parallel operation is used to increase the power capacity of the system or to secure higher reliability at critical loads. In the parallel operating system composed of the multiple UPSs, load-sharing, i.e. current balance control between them is key technique. Because of its low impedance and quick response characteristics, inverter output current changes very rapidly and thereby easily researches an overload condition. The difference between total load current divided by number of operating inverters and its own current is detected as unbalanced current. Then frequency and voltage are controlled to minimize the active component and the reactive component. A good performance of the proposed load-sharing technique is verified by experiments in the parallel operating system with two 40kVA UPSs.

  • PDF

저가격 고 신뢰성의 병렬 운전 제어 기법 (A Low Cost High Reliability Control Scheme in Parallel Inverters)

  • 정석언
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.274-276
    • /
    • 2007
  • In this paper, a low cost and high reliability control scheme is proposed for 400Hz UPS system operated in parallel. The proposed control scheme is consisted of two parts which are synchronization and load sharing control. The synchronization control is achieved by discrete logic ICs and analog circuit. The load sharing control is realized by current transformers (CTs) without any controller. Therefore, This proposed control scheme is rather simple and the cost may be decreased, compared with control scheme using expensive controller such as DSP and CAN. The practical feasibility of the proposed control scheme is proved by analysis and simulation.

  • PDF

정상상태 판별을 이용한 고전압 직류전원장천의 Wireless 병렬 운전 (Wireless parallel operation of high voltage DC power supply using steady-state estimation)

  • 손호섭;백주원;유동욱;김장목;김흥근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.208-211
    • /
    • 2003
  • This paper presents an improved droop method of the high voltage DC power supply which minimizes the voltage droop of a parallel-connected power supply. Conventionally, the droop method has been used to achieve a simple structure and no-interconnections among the power sources. However, it has a trade-off between output voltage regulation and load sharing accuracy. In this paper, the droop is minimized with a current and droop gain control using steady-stage estimation. The proposed method can achieve both high performance voltage regulation and load sharing. Two 10kV, 100mA parallel power modules were made and tested to verify the proposed current-sharing method.

  • PDF

정상상태 판별을 이용한 고전압전원장치의 Wireless 병렬운전 (Wireless Parallel Operation of High Voltage DC Pourer Supply using Steady-state Estimation)

  • 백주원;유동욱;손호섭;김장목
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권4호
    • /
    • pp.255-261
    • /
    • 2004
  • This paper presents an improved droop method which minimizes the voltage droop of a parallel-connected power supply Conventionally, the droop method has been used to achieve a simple structure and no-interconnections among power sources. However, it has a trade-off between output voltage regulation and load sharing accuracy In this paper, the droop is minimized with a current and droop gain control using steady-stage estimation. The proposed method can achieve both good voltage regulation and good load sharing. A design example of two 10㎸, 100㎃ parallel modules is made and tested to verify the proposed current-sharing method.