• Title/Summary/Keyword: Current power generation

Search Result 1,270, Processing Time 0.27 seconds

A Wind Turbine Simulator for Doubly-Fed Induction-type Generator with Automatic Operation Mode Change during Wind Speed Variation (가변 풍속시 운전모드 절환을 고려한 이중여자 유도형 풍력발전기의 시뮬레이터)

  • Song, Seung-Ho;Sim, Dong-Joon;Jeong, Byoung-Chang
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.349-360
    • /
    • 2006
  • Controller for doubly-fed induction-type wind generation system should be designed with mechanical power on blade. The controller in this paper consists of upper level controller and lower level controller. The upper level controller determines operating modes according to mechanical input power and calculates proper reference values. There are 4 operating modes - minimum speed control, variable torque control, torque limit control and idle mode. The lower level controller performs current regulated PWM control of rotor-side converter and grid-side inverter. A wind turbine simulator is implemented using doubly-fed induction-type generator and DSP based back-to-back converter to verify the performance of designed controller experimentally.

A Simulation for Anti-islanding Method in PV-AF System and Existing Anti-islanding Method (PV-AF시스템에서 단독운전 방지기법 및 기존 단독운전 방지기법의 시뮬레이션 해석 및 비교)

  • Kim, Gyeong-Hun;Seo, Hyo-Ryong;Lee, Soek-Ju;Park, Min-Won;Yu, In-Keun;Jeon, Jin-Hong;Kim, Seul-Gi;An, Jong-Bo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.206-207
    • /
    • 2007
  • Islanding is the electrical phenomenon in a part of a power network disconnected from the utility, where the loads are entirely supplied by PV systems, and where the voltage and frequency are maintained around nominal values. But islanding may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards[4]. Therefore, islanding must be detected and stopped. The existing anti-islanding methods have NDZ(None-detection Zone) or power quality degradation. But PV-AF power generation system has the function of not only shunt active filter but also anti-islanding method without NDZ. In this paper, It is proved that PV-AF system has originally the function of anti-islanding without not only NDZ and but current distortion

  • PDF

Performance Analysis of a Stand-alone Brushless Doubly-fed Induction Generator Using a New T-type Steady-state Model

  • Liu, Yi;Xu, Wei;Zhi, Gang;Zhang, Junlin
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.1027-1036
    • /
    • 2017
  • The brushless doubly-fed induction generator (BDFIG) is a new type of dual stator winding induction generator. In such a generator, both the power winding (PW) and the control winding (CW) are housed in the stator. This paper presents the performance characteristics of a stand-alone BDFIG operation system. A new T-type steady-state model of a BDFIG is proposed. This model is more suitable for the performance analysis of stand-alone BDFIGs than the conventional Π-type steady-state model and the simplified inner core steady-state model. The characteristics of the power flow and CW current are analyzed by detailed mathematical derivations on the basis of the proposed T-type steady-state model. The analysis results are verified by experiments, which are carried out on a prototype BDFIG. The results of the performance analysis contribute to simplifying the control circuit, improving the control performance, and selecting an appropriate BDFIG for actual industrial applications.

A Study On High Power Factor Sine Pulse Type Power Supply For Atmospheric Pressure Plasma Cleaning System with 3-Phase PFC Boost Converter (3상 PFC 부스트 컨버터를 채용한 상압플라즈마 세정기용 고역률 정형파 펄스 출력형 전원장치에 관한 연구)

  • Han, Hee-Min;Kim, Min-Young;Seo, Kwang-Duk;Kim, Joohn-Sheok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.72-81
    • /
    • 2009
  • This paper presents quasi-resonant type high power factor ac power supply for atmospheric pressure plasma cleaning system adopting three phase PFC boost converter and it's control method. The presented ac power supply consists of single phase H-bridge inverter, step-up transformer for generating high voltage and three phase PFC boost converter for high power factor on source utility. Unlikely to the traditional LC resonant converter, the propose one has an inductor inside only. A single resonant takes place through the inside inductor and the capacitor from the plasma load modeled into two series capacitor and one resistance. The quasi-resonant can be achieved by cutting the switching signal when the load current decrease to zero. To obtain power control ability, the propose converter controlled by two control schemes. One is the changing output pulse period scheme in the manner of PFM(Pulse Frequency Modulation) control. On the other, to provide more higher power to load, the DC rail voltage is directly controlled by the 3-phase PFC boost converter. The significant merits of the proposed converter are the uniform power providing capability for high quality plasma generation and low reactive power in AC and DC side. The proposed work is verified through digital simulation and experimental implementation.

Theoretical Investigation on Collinear Phase Matching Stimulated Polariton Scattering Generating THz Waves with a KTP Crystal

  • Tan, Lian;Yuan, Bin;Li, Yongjun;Wang, Silei;Zhang, Hongtao;Bing, Pibin;Yao, Jianquan;Li, Zhongyang
    • Current Optics and Photonics
    • /
    • v.3 no.4
    • /
    • pp.342-349
    • /
    • 2019
  • We present a theoretical research concerning terahertz (THz) wave generation with $KTiOPO_4$ (KTP) by collinear phase matching (CPM) stimulated polariton scattering (SPS). Both CPM and corresponding nonzero nonlinear coefficients can be simultaneously realized with $s{\rightarrow}f+f$ in yz plane, $s{\rightarrow}f+s$ with ${\theta}$ < ${\Omega}$ in xz plane and $s{\rightarrow}f+f$ with ${\theta}$ < ${\Omega}$ in xz plane. The effective nonlinear coefficients including electronic nonlinearities and ionic nonlinearities are calculated. Based on the parameter values of refractive indices, absorption coefficients and effective nonlinear coefficients, we simulate THz wave intensities generated with CPM SPS by solving coupled wave equations and give the relationship among the maximum THz wave intensity, optimal crystal length and the angle ${\theta}$. The calculation results demonstrate that CPM SPS with KTP can generate THz waves with high intensities and quantum conversion efficiencies.

Fabrication and Performance of $Bi_{0.5}Sb_{1.5}Te_{3}/Bi_{2}Te_{2.4}Se_{0.6}$ Thin Film Thermoelectric Generators ($Bi_{0.5}Sb_{1.5}Te_{3}/Bi_{2}Te_{2.4}Se_{0.6}$계 박막형 열전발전 소자의 제작과 작동 특성)

  • Kim Il-Ho;Jang Kyung-Wook
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.2
    • /
    • pp.180-185
    • /
    • 2006
  • Microwatt power level at relatively high voltage(order of volt) was produced by $Bi_{0.5}Sb_{1.5}Te_{3}/Bi_{2}Te_{2.4}Se_{0.6}$ thin film thermoelectric generators, and maximum output power varied with temperature difference in the square-law relation. Output voltage and current were possible to control by changing the way of electrical connection as well as the number of stacking plate-modules. Variation of open circuit voltage and short circuit current with temperature difference showed a linear relationship. There were, however, some differences in variations; open circuit voltage were dependent on the number of plate-module when connected in series, but it was not for parallel connection. On the other hand, short circuit current showed the opposite behavior to the case of open circuit current.

Development of DC-DC Converter for Arc Welding Machines using A Novel Half Bridge Soft Switching PWM Inverter (새로운 하프 브리지 소프트 스위칭 PWM 인버터를 이용한 용접기용 DC-DC 컨버터의 개발)

  • Kwon, Soon-Kurl;Mun, Sang-Pil
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.4
    • /
    • pp.60-67
    • /
    • 2008
  • This paper presents a new full-bridge soft switching PWM DC-DC converter circuit topology that adding two switcher, two lossless snubber quasi-resonance capacity, two diode to power source for general welding machine. This half bridge soft switching Is low voltage hight current output that first coil current is smaller than second coil current in high frequency transformer can be obtained with decreasing path loss in conventional DC bus line switcher. As it operate ZCS/ZVS in full range, high frequency, high efficiency and high output are implemented at low voltage and high DC current switching power supplies. All of this items are got from simulation and the result of experiment. If make up for the weak points of this proposed circuit, it will be used more easily for next generation TIG, MIG and MAG type of arc-welding machine.

Investigation of the Coil Deforamtion of the Gas Turbine Generator Rotor Using Finite Element Analysis (유한요소해석을 이용한 가스터빈 발전기 로터의 계자권선 변형 해석)

  • Yun, W.N.;Park, H.K.;Kang, M.S.;Kim, J.S.
    • Journal of Power System Engineering
    • /
    • v.13 no.6
    • /
    • pp.95-101
    • /
    • 2009
  • The generator for gas turbine power generation consists of the rotor which generates magnetic field, the winding coil which is the path for the field current and the wedge and retaining ring which prevents the radial movement of the coil. Relatively severe deformation was observed at the coil end section during the inspection of the generator for peaking-load operation, and the thermal-electricity and the centrifugal force were evaluated by the simple modeling of the windings to find the cause. But the simulation stress was not sufficient to induce the coil plastic deformation. The analysis result seems to be applicable to the base-load generators which runs continuously without shut down up to a year, but there had been more deformation than simulated for the generator which is started up and shut down frequently. The cause of the coil deformation was the restriction of the expansion and shrinkage. The restriction occurs when the winding coil shrinks, and the stress overwhelms the yield stress and cause the plastic deformation. The deformation is accumulated during the start-ups and shut-downs and the thermal growth occurs. The factors which induce the coil restriction during the expansion and shrinkage should be reduced to prevent the unallowable deformation. The resolutions are cutting off the field current earlier during the generator shut-down, modifying the coil end section to remove the stress concentration and making the insulation plate inserted between the coil end section and the retaining ring have the constant thickness.

  • PDF

Treatment Stimulator's Pulse of Transcranial Magnetic Stimulation (경두개 자기자극장치의 치료자극 펄스)

  • Kim, Whi-Young
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.11
    • /
    • pp.289-296
    • /
    • 2009
  • In this study, I presented power control unit with potential use in the magnetic stimulation of biological systems. The effect of the magnetic stimulation depends on the geometry and orientation of the induced electric field as well as on the current pulse waveform delivered by the stimulator coil. TMS is achieved from the outside of the head using pulses of electromagnetic field that induce an electric field in the brain. There are numerous possibities in the applications TMS, such as diagnosis and therapy through the brain stimulation. These factors are very important to define the equipment requirements and characteristics in that the topology of the power supply and the size and geometry of the coil. The proposed solution is the generation of current pulses with variable amplitude and duration, according to a user defined input. Another solution is the topology that uses elements to store and transfer energy from the power source to the load. In addition to proposed topology, an adequate control strategy and right set of the power circuit parameters made possible to obtain unipolar waves and bipolar waves.

Korean Nuclear Reactor Strategy for the Early 21st Century -A Techno-Economic and Constraints Comparison- (21세기 차세대 한국형 원자로 전략 -기술경제 제약요인 비교-)

  • Lee, Byong-Whi;Shin, Young-Kyun
    • Nuclear Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.20-29
    • /
    • 1991
  • The system analysis for Korean nuclear power reactor option is made on the basis of reliability, cost minimization, finite uranium resource availability and nuclear engineering manpower supply constraints. The reference reactor scenarios are developed considering the future electricity demand, nuclear share, current nuclear power plant standardization program and manufacturing capacity. The levelized power generation cost, uranium requirement and nuclear engineering professionals demand are estimated for each reference reactor scenarios and nuclear fuel cycle options from the year 1990 up to the year 2030. Based on the outcomes of the analysis, uranium resource utilization, reliability and nuclear engineering manpower requirements are sensitive to the nuclear reactor strategy and associated fuel cycle whereas the system cost is not. APWR, CANDU longrightarrow FBR strategy is to be the best option for Korea. However, APWR, CANDU longrightarrow Passive Safe Reactor(PSR)longrightarrowFBR strategy should be also considered as a contingency for growing national concerns on nuclear safety and public acceptance deterioration in the future. FBR development and establishment of related fuel cycle should be started as soon as possible considering the uranium shortage anticipated between 2007 and 2032. It should be noted that the increasing use of nuclear energy to minimize the greenhouse effects in the early 21st century would accelerate the uranium resource depletion. The study also concludes that the current level of nuclear engineering professionals employment is not sufficient until 2010 for the establishment of nuclear infrastructure.

  • PDF