• Title/Summary/Keyword: Current power generation

Search Result 1,270, Processing Time 0.032 seconds

Relationship with breakdown electric current of connection transformer connection method and distribution system of wind power generation system (풍력발전시스템의 연계변압기 결선방법과 배전계통의 고장전류와의 관계)

  • An, Hae-Joon;Ro, Kyoung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1193-1194
    • /
    • 2006
  • 전력계통에 적용하기 위한 풍력발전시스템의 연계변압기 결선방법과 배전계통의 고장전류와의 관계를 알아보고 계통에서의 단상 고장전류 발생 시 변압기 결선 방식의 변화에 따른 simulation을 수행하고자 한다.

  • PDF

Report of 2050 Energy Technology Perspectives 2015 and Activities on IEA/ECERC Delegation of Korea (2050 에너지기술전망 (2015판) 및 국제에너지기구 활동 보고)

  • Bae, Choongsik
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.279-282
    • /
    • 2015
  • Energy Technology Perspectives (ETP) has provided the current status of energy system, technology developments and external events that have changed ETP scenario since 2006. The three scenarios are presented in four different fields (power generation, transport, industry, building). Energy efficiency improvement of energy system and the new system that can solve the increasing energy demand and the emissions are introduced. The activities on IEA/ECERC delegation of Korea will be also reported in this presentation.

  • PDF

A Study on the Four Quadrant Operation of SRM Drive (SRM의 4상한 구동을 위한 제어방식)

  • Kang Yu-Jung;Park Sung-Jun;Ahn Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.45-48
    • /
    • 2002
  • Switched Reluctance Generator attracts much attention because of high efficiency, simple controllability with traction drive. But the theories that have been adopted as SRG control methods are complicated up to the present. This paper proposes reference current limitation strategy for stable generation and switching angle control in motoring mode. The proposed method is verified by simulation and experiments.

  • PDF

Performance Analysis of A Variable-Spacing Cesium Thermionic Energy Converter (열전변환 장치의 특성 분석에 대한 연구)

  • Lee, Deuk-Yong
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.9
    • /
    • pp.1085-1094
    • /
    • 1992
  • A variable-spacing cesium thermionic energy conversion test station is designed and fabricated for the study of power generation. The diode is in the form of a guard-ringed plane-parallel geometry in which a polycrystalline rhenium emitter of 2 cmS02T area faces a radiation-cooled polycrystalline rhenium collector of 1.9 cmS02T area. The emission of plasma from heated refractory electrode metal is the driving reaction in the direct conversion of heat to electricity by thermionic energy conversion. The plasma is produced from electrons and positive ions formed simultaneously by thermionic emission and surface ionization of cesium atoms incident on the hot emitter from the cesium vapor in the diode. And high plasma density causes plasma multiplication within the gap due to volume ionization that results in high power output. The variation of the saturation current of a Knudsen converter is investigated at an emitter-collector gap of 0.1 mm and an emitter temperatures. A maximum power output of 13.47 watta/cmS02T is observed at a collector temperature of 963 K and a cesium reservoir temperature of 603 K.

Test Results of Pulsed Power Supply for Nonthermal Plasma Process (저온 플라즈마 공정용 펄스발생 전원장치의 성능시험)

  • Jang, S.D.;Byun, Y.C.;Cho, M.H.;Shin, D.N.
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1574-1575
    • /
    • 2011
  • The application of a pulsed power system is being extended to an environmental and industrial field. The non-destructive gaseous pollutants from industrial plants such as power generation plants and incinerators can be processed by applying high voltage pulses with a fast rising time (a few nanoseconds) and short duration (nano to microseconds) in a pulsed corona discharge reactor. The pulsed plasma generator with a triggered switch has been developed. Its corona current in load can be adjusted by applied voltage and repetition rate. We investigated the performance of the pulsed plasma generator by analyzing the concentration of ozone in small reactor. This paper describes the electrical characteristics of the pulse generator with a voltage of 30 kV at repetition rate of 50 PPS. In addition, we briefly discuss a configuration of the system and initial test results.

  • PDF

Diagnosis Method of Output Power Lowering of PV System by Using Kalman Filter Algorithm (Kalman Filter 알고리즘을 이용한 태양광 발전 시스템의 출력저하 진단법)

  • Kang, Byung-Kwan;Kim, Seung-Tak;Lee, Hyun-Gu;Bae, Sun-Ho;Park, Jung-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1537-1546
    • /
    • 2011
  • The photovoltaic(PV) generation system have recently become widely used to solve the environmental problems and running out of fossil fuels. However, the study on maintenance is inadequate for PV system. This paper proposes the novel diagnosis method of output power decline to maintain the normal output performance of PV array. The diagnosis method used the proportional relation of irradiation-output current(S-I) of PV array at maximum power point(MPP). And, first order polynomial using the relation is proposed to easily apply PV system. To estimate the relation in case of separation of PV array producer and diagnosis system producer. Kalman Filter algorithm is also proposed at 30.2kW grid-connected PV system. Then, the performance of diagnosis method is evaluated using the hardware tests as well as the simulation.

Performance of Passive Boost Switched Reluctance Converter for Single-phase Switched Reluctance Motor

  • Ahn, Jin-Woo;Lee, Dong-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.505-512
    • /
    • 2011
  • A novel passive boost power converter forsingle-phaseswitched reluctance motor is presented. A simple passive circuit is proposed comprisingthree diodes and one capacitor. The passive circuitis added in the front-end of a conventional asymmetric converter to obtain high negative bias. Based on this passive network, the terminal voltage of the converter side is a general DC-link voltage level in parallel mode up to a double DC-link voltage level in series mode. Thus,it can suppress the negative torque generation from the tail current and improve the output power. The results of the comparative simulation and experiments forthe conventional and proposed converter verify the performance of the proposed converter.

Simplified Wind Turbine Modeling and Calculation of PCC Voltage Variation according to Grid Connection Conditions (간략화된 풍력발전기 모델링과 계통연계 조건에 따른 PCC 전압 변동량 계산)

  • Im, Jl-Hoon;Song, Seung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2402-2409
    • /
    • 2009
  • This paper proposed a simple and helpful analysis model of voltage variation in order to predict the voltage variation at PCC (Point of Common Coupling), when a wind turbine is connected in an isolated grid. The PCC voltage flucuates when the wind turbine outputs active power to an isolated grid. This voltage variation is proportional to the product of the line impedance from the ideal generator to the PCC and the wind turbine output current. And It is different according as where wind turbine is connected. To solve the problem of voltage variation, this paper proposed the reactive power control. To verify the proposed analysis model, this paper utilized PSCAD/EMTDC Simulation and the field measurement data of the voltage variation during the wind power generation.

Sliding Mode Controller Applied to Coupled Inductor Dual Boost Inverters

  • Fang, Yu;Cao, Songyin;Wheeler, Pat
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1403-1412
    • /
    • 2019
  • A coupled inductor-dual boost-inverter (CIDBI) with a differential structure has been presented for application to a micro-inverter photovoltaic module system due to its turn ratio of a high-voltage level. However, it is difficult to design a CIDBI converter with a conventional PI regulator to be stable and achieve good dynamic performance, given the fact that it is a high order system. In view of this situation, a sliding mode control (SMC) strategy is introduced in this paper, and two different sliding mode controllers (SMCs) are proposed and adopted in the left and right side of two Boost sub-circuits to implement the corresponding regulation of the voltage and current. The schemes of the SMCs have been elaborated in this paper including the establishment of a system variable structure model, selection of the sliding surface, determination of the control law, and presentation of the reaching conditions and sliding domain. Finally, the mathematic analysis and the proposed SMC are verified by experimental results.

A Study on Battery Chargers for the next generation high speed train using the Phase-shift Full-bridge DC/DC Converter (위상전이 풀-브리지 DC/DC 컨버터를 이용한 차세대 고속 전철용 Battery Charger에 관한 연구)

  • Cho, Han-Jin;Lee, Won-Cheol;Lee, Sang-Seok;Kim, Tae-Hwan;Won, Chung-Yuen
    • Proceedings of the KSR Conference
    • /
    • 2009.05b
    • /
    • pp.623-628
    • /
    • 2009
  • There is an increasing demand for efficient high power/weight auxiliary power supplies for use on high speed traction application. Many new conversion techniques have been proposed to reduce the voltage and current stress of switching components, and the switching losses in the traditional pulse width modulation(PWM) converter. Especially, the phase shift full bridge zero voltage switching PWM techniques are thought most desirable for many applications because this topology permits all switching devices to operate under zero voltage switching(ZVS) by using circuit parasitic components such as leakage inductance of high frequency transformer and power device junction capacitance. The proposed topology is found to have higher efficiency than conventional soft-switching converter. Also it is easily applicable to phase shift full bridge converter by applying an energy recovery snubber consisted of fast recovery diodes and capacitors.

  • PDF