• 제목/요약/키워드: Current measurements

검색결과 1,737건 처리시간 0.033초

Real-Time Monitoring and Analysis of Power Systems with Synchronized Phasor Measurements

  • Kim, Hong-Rae
    • 조명전기설비학회논문지
    • /
    • 제21권9호
    • /
    • pp.101-108
    • /
    • 2007
  • State estimators are used to monitor the operating states of power systems in modern EMS. It iteratively calculates the voltage profile of the currently operating power system with voltage, current, and power measurements gathered from the entire system. All the measurements are usually assumed to be obtained simultaneously. It is practically impossible, however, to maintain the synchronism of the measurement data. Recently, phasor measurements synchronized via satellite are used for the operation of these power systems. This paper describes the modified state estimator used to support the processing of synchronized phasor measurements. Synchronized phasor measurements are found to provide synchronism of measurement data and improve the accuracy/redundancy of the measurement data for state estimation. The details of the developed state estimation program and some numerical results of operation are presented.

시각동기 위상측정데이터를 이용한 전력계통 상태추정 (Electric Power System State Estimation with Time Synchronized Phasor Measurement Data)

  • 권형석;장한성;김홍래
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권9호
    • /
    • pp.359-364
    • /
    • 2006
  • In modern EMS, state estimation is used as a tool for monitoring how the power system operates. A state estimator iteratively calculates the voltage profile of the currently operating power system with voltage, current, and power measurements gathered from the entire system. It is usually assumed that all the measurements are obtained simultaneously. It, however, is not practically possible to maintain the synchronism of the measurements data. Recently, phasor measurements synchronized by satellites are used for the operation of the power systems. This paper describes the state estimator modified to support the processing of synchronized phasor measurements. Synchronized phasor measurements are found to provide synchronism of measurement data and improve the nccuracy/redundancy of the results of running it are presented.

임베디드 마이크로프로세서에서 산술 및 논리 명령어에 대한 전력 예측 모델 (A Power Estimation Model for Arithmetic and Logic Instructions of Embedded Microprocessors)

  • 신동하;강경희
    • 한국정보통신학회논문지
    • /
    • 제10권8호
    • /
    • pp.1422-1427
    • /
    • 2006
  • 임베디드 마이크로프로세서가 소프트웨어를 수행하면서 소비하는 전력을 예측하기 위해서는 마이크로프로세서의 각 명령어가 수행하면서 소비하는 전류를 측정하여 활용한다. 본 논문에서는 임베디드 마이크로프로세서 adc16s310의 산술 및 논리 명령어에 대한 소비 전류를 측정 및 분석하고, 이를 바탕으로 적은 수의 측정 소비 전류 값을 사용하여 비교적 정확하게 모든 명령어 수행의 소비 전류 값을 예측할 수 있는 전력 예측 모델을 제안한다. 본 예측 모델은 마이크로프로세서 adc16s310의 산술 및 논리 명령어에 대하여 총 측정 공간 중 약5.84%의 공간에 대한 측정 전류 값만을 사용하여 평균 오차 0.34%에서 소비 전류 값을 예측할 수 있다.

Electrical Properties of Metal - Insulator- Metal Diode for AM-LCD Driving

  • Kim, Jang-Kwon;Lee, Myung-Jae;Kim, Dong-Sik;Chung, Kwan-Soo
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -2
    • /
    • pp.1125-1128
    • /
    • 2002
  • Tantalum pentoxide (Ta$_2$O$\sub$5/) is a candidate for use in metal-insulator-metal diode in switching devices for active-matrix liquid-crystal displays. The MIM diode with very low threshold voltage and perfect symmetry was fabricated. High quality Ta$_2$O$\sub$5/ thin films were obtained by using an anodizing method. Rutherford backscattering spectroscopy, transmission electron microscope observations, auger electron spectroscopy, ellipsometry measurements, and electrical measurements, such as current - voltage(I-V) measurements were performed to investigate Ta$_2$O$\sub$5/ films and their reliability and indicated that the obtained TaOx thin films were reliable Ta$_2$O$\sub$5/ films for the applications. Furthermore, in this paper, we discuss the effects of top-electrode metals and annealing conditions. The conduction mechanism of the leakage current and the symmetry characteristics related to the Schottky emission and Poole-Frankel effect are also discussed using the results of electrical measurements and conduction barrier theory.

  • PDF

Ohmic Contact for Hole Injection Probed by Dark Injection Space-Charge-Limited Current Measurements

  • Song, Ok-Keun;Koo, Young-Mo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1061-1064
    • /
    • 2009
  • Through dark injection space-charge-limited current (DI-SCLC) and trap-free SCLC measurements, it has been demonstrated that an indium tin oxide (ITO)/buckminsterfullerene ($C_{60}$) electrode can form a quasi-Ohmic contact with N, N'-bis (naphthalen-1-yl)-N, N'-bis(phenyl) benzidine (NPB). The DI-SCLC results show a clear peak current along with a shift of the peak position as the field intensity varies, implying an Ohmic (or quasi-Ohmic) contact. A theoretical simulation of the SCLC also shows that ITO/$C_{60}$ forms an Ohmic contact with NPB. The Ohmic contact makes it possible to estimate the NPB hole mobility through the use of both DI-SCLC and trap-free SCLC analysis. This also contributes to a reduction in power consumption.

  • PDF

Observations of the Cheju Current

  • Suk, Moon-Sik;Pang, Ig-Chan;Teague, William J.;Chang, Kyung-Il
    • Journal of the korean society of oceanography
    • /
    • 제35권3호
    • /
    • pp.129-152
    • /
    • 2000
  • The Cheju Current (CC), defined here as a mean eastward flow in the Cheju Strait, mostly carries water of high temperature and salinity originating from the Kuroshio in winter and spring, the Cheju Warm Current Water (CWCW). The strong core of the eastward component of the CC is found close to Cheju Island (Cheju-Do, hereafter) in winter and spring with a peak speed of about 17.0 cm/s. The eastward flow weakens towards the northern Cheju Strait, and a weak westward flow occurs occasionally close to the southern coast of Korea. The volume transport ranges from 0.37 to 0.45 Sv(1 Sv=10$^6$ m$^3$/s) in winter and spring. Seasonal thermocline and harocline are formed in summer and eroded in November. The occurrence of the CWCW is confined in the southern Cheju Strait close to Cheju-Do below the seasonal thermocline in summer and fall, and cold water occupies the lower layer north of the CWCW which is thought to be brought into the area from the area west of Cheju-Do along with the CWCW. Stratification acts to increase both the speed of the CC with a peak speed of greater than 30 cm/s and the vertical shear of the along-strait currents. The strong core of the CC detached from the coast of Cheju-Do and shifted to the north during the stratified seasons. The volume transport in summer and fall ranges 0.510.66 Sv, which is about 1.5 times larger than that in winter and spring. An annual cycle of the cross-strait sea level difference shows its maximum in summer and fall and minimum in winter and spring, whose tendency is consistent with the annual variability of the CC and its transport estimated from the ADCP measurements. Moored current measurements west of Cheju-Do indicate the clockwise turning of the CC, and the moored current measurements in the Cheju Strait for 1530 days show the low-frequency variability of the along-strait flow with a period of about 37 days.

  • PDF

Wave Generation And Wind-Induced Shear Current In Water

  • Choi, Injune
    • 한국해양학회지
    • /
    • 제15권1호
    • /
    • pp.1-7
    • /
    • 1980
  • The results of measurements of shear current induced in water by wind in wind wave tunnel are presented briefly. The shear current distributions are found to fit reasonably well an exponentiall form. This form was used to estimate surface velocity and boundary layer thickness used in stability analysis. An analysis of hydrodynamic stability of the shear current was carried out, using a broken line as an approximate profile, to see the stability as a possible mechanism of wind wave generation. Comparison between experimental results and theoretical ones shows that there exists a large discrepancy particularly in phase velocity and hydrodynamic instability of the shear current seems not to be the basic mechanism of wind wave generation.

  • PDF

엄지발가락휨각도 측정을 위한 각도계의 신뢰도와 타당도 (Reliability and Validity of the Goniometer for Hallux Valgus Angle Measurement)

  • 정성대;강선영;김문환;원종혁
    • 한국전문물리치료학회지
    • /
    • 제20권2호
    • /
    • pp.46-51
    • /
    • 2013
  • The purpose of this study was to investigate the reliability and validity of goniometer measurements of the hallux valgus angle (HVA) compared to radiographic measurements, which are the current standard. Twenty subjects (10 female, 10 male) were recruited for this study (40 feet). The HVA of the subjects was measured using goniometer and radiographic measurement. In three trials, measurements were taken of each subject by two examiners using goniometer and radiographic measurements using radiography in a standing position. The reliability of the measurements was investigated using intraclass correlation coefficients (ICC(3,1)), and the validity was tested using the Pearson product-moment correlation coefficient and an independent t-test. The intra-rater reliability of left and right HVAs were poor (ICC=.409 and .341, respectively). The inter-rater reliability of left and right HVAs were poor and moderate (ICC=.303 and .501, respectively). Left and right HVAs measured using goniometer and radiographic measurements were also poor and moderate (Pearson r=.246 and .544, respectively). These results suggest that goniometer measurements of the HVA are inaccurate and have unacceptable validity compared to radiographic measurements.

SI GaAs : Cr과 Undoped GaAs의 깊은 준위 (Deep Levels in Semi-Insulating GaAs : Cr and Undoped GaAs)

  • 이진구
    • 대한전자공학회논문지
    • /
    • 제25권11호
    • /
    • pp.1294-1303
    • /
    • 1988
  • 광 유도 전류 천이 (photo-induced current transient)방법으로 측정한 SI GaAs의 전자와 정공 trap이 갖을 수 있는 activation energy({\Delta}E_r)의 범위는 0.16$\pm$ 0.01eV에서 0.98$\pm$ 0.01eV까지 분포되어 있다. SI Undoped GaAs가 SI GaAs : Cr 보다 깊은 준위의 수가 적음을 확인 하였다. Trap의 열적인 capture cross section과 농도를 평가 하였고, 약간의 trap은 SI GaAs 성장시에 발생될 수 있는 결함과 관련되어 있음을 확인하였다. 특히 SI GaAs에서 보상 level로 작용하는 Cr과 “0” level를 좀 더 정확하게 측정하기 위하여 서로 다른 측정방법을 사용하여 측정한 결과를 각기 비교 검토 하였다. 즉, PICT측정, 상온 이상의 온도에서 측정한 Hall data 및 광전류 spectra data 등을 비교 검토 하였으며, 보상 level은 격자 결합이 매우 약함을 확인할 수 있었다. Hall data를 computer로 분석한 결과 중성 불순물 scattering이 측정 온도 범위에서 매우 중요한 역할을 하고 있음을 알 수 있었다.

  • PDF

전자파와 수표면 영상을 이용한 산지하천 홍수유량 및 유속 계측 비교 연구 (Comparison of Flood Discharge and Velocity Measurements in a Mountain Stream Using Electromagnetic Wave and Surface Image)

  • 양성기;김동수;류권규;강명수;정우열;이준호;김용석;유호준
    • 한국환경과학회지
    • /
    • 제21권6호
    • /
    • pp.739-747
    • /
    • 2012
  • Due to the difficulties for measuring flood discharge in the dangerous field conditions, conventional instruments with relatively low accuracy such as float still have been widely utilized for the field survey. It is also limited to use simple stage-discharge relationship for assessment of the flood discharge, since the stage-discharge relationship during the flood becomes complicated loop shape. In recent years, various non-intrusive velocity measurement techniques such as electromagnetic wave or surface images have been developed, which is quite adequate for the flood discharge measurements. However, these new non-intrusive techniques have little tested in the flood condition, though they promised efficiency and accuracy. Throughout the field observations, we evaluated the validity of these techniques by comparing discharge and velocity measurements acquired concurrently during the flood in a mountain stream. As a result, the flood discharge measurements between electromagnetic wave and surface image processing techniques showed high positive relationship, but velocities did not matched very well particularly for the high current speed more 3 m/s. Therefore, it should be noted here that special cares are required when the velocity measurements by those two different techniques are used, for instance, for the validation of the numerical models. In addition, authors assured that, for the more accurate flood discharge measurements, velocity observation as well as stage height is strongly necessary owing that the unsteady flow occurs during the flood.