• Title/Summary/Keyword: Current imbalance

Search Result 209, Processing Time 0.035 seconds

Delay Time Modeling for ED MOS Logic LSI and Multiple Delay Logic Simulator (ED MOS 논리 LSI 의 지연시간 모델링과 디자인 논리 시뮬레이터)

  • 김경호;전영준;이창우;박송배
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.4
    • /
    • pp.701-707
    • /
    • 1987
  • This paper is concerned with an accurate delay time modling of the ED MOS logic gates and its application to the multiple delay logic simulator. The proposed delay model of the ED MOS logic gate takes account of the effects of not only the loading conditions but also the slope of the input waveform. Defining delay as the time spent by the current imbalance of the active inverter to charge and discharge the output load, with respect to physical reference levels, rise and fall model delay times are obtained in an explicit formulation, using optimally weighted imbalance currents at the end points of the voltage transition. A logic simulator which uses multiple rise/fall delays based on the model as decribed in the above has been developed. The new delay model and timing verification method are evaluated with repect to delay accuracy and execution time.

  • PDF

Analysis of Neutral Point Current in Grid Tied 3-level NPC Converter under Various Grid Imbalance Conditions (다양한 계통 불평형 상황에서 계통연계형 3-level NPC 컨버터의 중성점 전류에 대한 해석)

  • Choi, Jaehoon;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.186-188
    • /
    • 2019
  • 현재 신재생에너지 발전원은 계속 증가되고 있으며, 발전기의 용량 또한 점점 증가하고 있다. 늘어나는 신재생에너지 발전원에 의해 계통 연계의 중요성이 증대되고 있고 아울러 계통에서 발생할 수 있는 여러 가지 사고로 인한 발전기의 PCS의 고장에 대한 문제 또한 중요해지고 있다. 본 논문에서는 신재생발전원의 용량이 증가함에 따라서 각 스위치의 전기적 스트레스를 줄일 수 있는 3-level NPC 타입의 컨버터회로를 기반으로 이중 전류 제어기를 이용하였고, 계통 사고시에도 강인한 위상 추종 특성을 가지는 DDSRF(Decoupled Double Synchronous Reference Frame 이하 DDSRF)방식의 PPL을 채택하여 시뮬레이션을 진행하였다. 현재 계통의 사고에 의한 사고전압은 ABC 분류에 의해서 크게 A~G 타입으로 나타내고 있다. 본 논문에서는 각 타입별 사고전압의 불평형 지수(Imbalance Factor, 이하 IF)에 따른 중성점 전류의 고조파 성분을 분석하여 도식화 하고자 한다. 이는 계통사고 발생 시 계통연계형 컨버터의 제어 및 계통탈락 여부에 활용 할 수 있을 것으로 예상된다.

  • PDF

Ramp-rate limitation of CIC(Cable-In-Conduit) superconducting magnet (관내권선(Cable-In-Conduit, CIC) 초전도 자석(Superconducting magnet)에서의 한계 자속 변화(ramp-rate limitation) 현상)

  • Jeong, Sang-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.37-40
    • /
    • 1996
  • Cable-In-Conduit Conductor(CICC) is widely accepted as an advanced superconductor configuration for large scale applications such as tokamak fusion reactors, MAGLEV (MAGnetic LEVitation), and SMES (Superconducting Magnetic Energy Storage). The stability of CICC cooled with supercritical helium can be very high if it is operated below a certain limiting current. This limiting current can be determined by Stekly type heat balance equation. The stability characteristic of CICC for AC operation is more complicated than that of DC because there are additional instability sources which are associated with local flux change. Ramp-rate limitation is a phenomenon discovered during US-DPC (United States-Demonstration Poloidal Coil) program, which showed apparent quench current degradation associated with high dB/dt. This paper describes recent experimental investigation results on the ramp-rate limitation and discusses current imbalance, induced current, current redistribution due to local quench of the strand in the cable.

  • PDF

Properties of a Hybrid Type Superconducting Fault Current Limiter using YBa2Cu3O7 Films (YBa2Cu3O7 박막을 이용한 하이브리드형 초전도 사고전류제한기의 특성)

  • Choi, Hyo-Sang;Cho, Yong-Sun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.4
    • /
    • pp.391-397
    • /
    • 2006
  • We present investigations of a hybrid type superconducting fault current limiter (SFCL), which consists of transformers and resistive superconducting elements. The secondary windings of the transformer were separated into several electrically isolated circuits and linked inductively with each other by mutual flux, each of which has a superconducting current limiting element of $YBa_2Cu_3O_7$ (YBCO) stripes as a current limiting element. Simple connection in series of the SFCL elements tends to produce ill-timed quenching because of power dissipation unbalance between SFCL elements. Both electrical isolation and mutual flux linkage of the elements provides a solution to power dissipation unbalance, inducing simultaneous quench and current redistribution of the YBCO films. This design enables to increase the voltage rating of SFCL with given YBCO stripes.

Classification Algorithm-based Prediction Performance of Order Imbalance Information on Short-Term Stock Price (분류 알고리즘 기반 주문 불균형 정보의 단기 주가 예측 성과)

  • Kim, S.W.
    • Journal of Intelligence and Information Systems
    • /
    • v.28 no.4
    • /
    • pp.157-177
    • /
    • 2022
  • Investors are trading stocks by keeping a close watch on the order information submitted by domestic and foreign investors in real time through Limit Order Book information, so-called price current provided by securities firms. Will order information released in the Limit Order Book be useful in stock price prediction? This study analyzes whether it is significant as a predictor of future stock price up or down when order imbalances appear as investors' buying and selling orders are concentrated to one side during intra-day trading time. Using classification algorithms, this study improved the prediction accuracy of the order imbalance information on the short-term price up and down trend, that is the closing price up and down of the day. Day trading strategies are proposed using the predicted price trends of the classification algorithms and the trading performances are analyzed through empirical analysis. The 5-minute KOSPI200 Index Futures data were analyzed for 4,564 days from January 19, 2004 to June 30, 2022. The results of the empirical analysis are as follows. First, order imbalance information has a significant impact on the current stock prices. Second, the order imbalance information observed in the early morning has a significant forecasting power on the price trends from the early morning to the market closing time. Third, the Support Vector Machines algorithm showed the highest prediction accuracy on the day's closing price trends using the order imbalance information at 54.1%. Fourth, the order imbalance information measured at an early time of day had higher prediction accuracy than the order imbalance information measured at a later time of day. Fifth, the trading performances of the day trading strategies using the prediction results of the classification algorithms on the price up and down trends were higher than that of the benchmark trading strategy. Sixth, except for the K-Nearest Neighbor algorithm, all investment performances using the classification algorithms showed average higher total profits than that of the benchmark strategy. Seventh, the trading performances using the predictive results of the Logical Regression, Random Forest, Support Vector Machines, and XGBoost algorithms showed higher results than the benchmark strategy in the Sharpe Ratio, which evaluates both profitability and risk. This study has an academic difference from existing studies in that it documented the economic value of the total buy & sell order volume information among the Limit Order Book information. The empirical results of this study are also valuable to the market participants from a trading perspective. In future studies, it is necessary to improve the performance of the trading strategy using more accurate price prediction results by expanding to deep learning models which are actively being studied for predicting stock prices recently.

Increase of resistive type superconducting fault current limiter capacity (박막 저항형 초전도 한류기의 용량증대를 위한 방안)

  • Cha, Sang-Do;Kim, H.R.;Choi, H.S.;Hyun, O.B.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.790-792
    • /
    • 2002
  • The resistive type superconducting fault current limiter(SFCL) is a current limiter using the Quench mechanism of superconductors. When Quench occurs in superconductors, the resistance of superconductors increases abruptly. In order to increase SFCL capacity, current limiting elements were connected in series. If the Quench current of each element was different, voltage distribution was imbalanced. This imbalance could be removed by arrangement including series and parallel connection of elements. Based on this result, an SFCL of 1.8kV/50A was designed and experimented, expecially, in terms of increasing the voltage rating.

  • PDF

Characteristics of Sheath Circulating Current by Underground Transmission Systems Analysis (지중송전시스템 해석을 통한 시스순환전류 특성 분석)

  • Jung, Chae-Kyun;Lee, Jong-Beom;Kang, Ji-Won
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.449-451
    • /
    • 2002
  • Sheath circulating current rises from the change of sheath mutual impedance which is caused by imbalanced cable system, and different section length between joint boxes. However, mixed burying typo and imbalance section length take many parts of main reasons of sheath circulating current increment in domestic underground transmission power cables. Therefore, the increment reason and variation characteristics of sheath circulating current is analysed with simulation using EMTP/ATPDraw and measuring data of practical cable system which has a problem of exceeding sheath circulating current in this paper.

  • PDF

A Study on the Protection Methods of Sheath Circulating Current Reduction Device in Transient State (과도상태에서의 시스순환전류 저감장치 보호방안에 관한 연구)

  • Kang, Ji-Won;Jung, Chae-Kyun;Lee, Jong-Beom;Lee, Dong-Il;Jung, Gil-Jo
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.53-58
    • /
    • 2002
  • Sheath circulating current is increased as the change of sheath mutual impedance which is caused by imbalance of cable system, and different section length between joint box. If excessive current flows in sheath. sheath loss will be increased and then transmission capacity of underground transmission system is reduced. Accordingly, This paper proposed sheath current reduction device using resistor and reactor and proved the reduction effect of that device using EMTP/ATP. And also in this paper, when transients are occurred at the underground system with reduction device by ground fault and lightning surge. we analyzes transient effect of system variously. From this result. authors establish the protection methods of sheath circulating current reduction device.

  • PDF

The Development of 30KVA IGBT-type Customer STATCOM (수용가용 30kVA급 IGBT형 STATCOM 개발)

  • Lim, Su-Saeng;Lee, Eun-Woong;Kim, J.K.;Sohn, H.K.;Cho, H.K.;Jeong, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.657-659
    • /
    • 2002
  • Power quality refers to voltage quality and current quality. Voltage quality means supply reliance such as voltage sag, voltage swell. and short-time interruption. Current quality is related to power factor, harmonic distortion, negative-sequence and zero-sequence current. We fabricated Customer STATCOM to improve current quality such as reactive power, harmonic distortion, and load imbalance. In this paper. We summarize the spec, of STATCOM. its hardware configuration, and control system.

  • PDF

Analysis of Average Neutral Point Current in 3-level NPC Converter under Generalized Unbalanced AC Input Condition

  • Jung, Kyungsub;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.151-152
    • /
    • 2016
  • This paper presents a neutral point deviation compensating control algorithm applied to a 3-level NPC converter under generalized unbalanced ac input conditions. The neutral point deviation is analyzed with a focus on the current flowing out of or into the neutral point of the dc-link in 3-level NPC converter. The model of neutral point deviation and neutral current are also constructed. The positive and negative sequence components of the pole voltages and ac input currents are employed to accurately explain the behavior of 3-level NPC converter and its impact on neutral point deviation. This paper includes the harmonic characteristic of neutral point current under various imbalance AC operating conditions.

  • PDF