• 제목/요약/키워드: Current imbalance

Search Result 212, Processing Time 0.036 seconds

Modeling and Control of Integrated STATCOM-SMES System to Improve Power System Oscillations Damping

  • Molina, Marcelo G.;Mercado, Pedro E.
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.4
    • /
    • pp.528-537
    • /
    • 2008
  • Primary frequency control(PFC) has the ability to regulate short period random variations of frequency during normal operation conditions and also to respond rapidly to emergencies. However, during the past decade, numerous significant sized blackouts occurred worldwide that resulted in serious economic losses. Therefore, the conclusion has been reached that the ability of the current PFC to meet an emergency is poor, and security of power systems should be improved. An alternative to enhance the PFC and thus security is to store excessive amounts of energy during off-peak load periods in efficient energy storage systems for substituting the primary control reserve. In this sense, superconducting magnetic energy storage(SMES) in combination with a static synchronous compensator(STATCOM) is capable of supplying power systems with both active and reactive powers simultaneously and very rapidly, and thus is able to enhance the security dramatically. In this paper, a new concept of PFC based on incorporating a STATCOM-SMES is presented. A complete detailed model is proposed and a new control scheme is designed, comprising an enhanced frequency control scheme, and a fully decoupled current control strategy in d-q coordinates with a novel controller to prevent dc bus capacitors voltage drift/imbalance. The performance of the proposed control schemes is validated through digital simulation carried out using MATLAB/Simulink.

Proposal of the Grid-connected Single Phase PCS including the Function of Active Filter (엑티브 필터 기능을 갖는 계통연계형 단상 태양광 발전시스템의 제안)

  • Jang, Seong-Jae;Seo, Hyo-Ryong;Kim, Gyeong-Hun;Park, Sang-Soo;Park, Minwon;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1077-1078
    • /
    • 2008
  • The growing number of nonlinear loads such as static power converters has posed a problem on the quality of electric power supply. The active filters (AF) have been rapidly expanding with the advancement of power electronics technology. The purpose of the active filters is to compensate current harmonics and/or current imbalance. The authors have studied and introduced the PV-AF system; the PV power system, which is used widely as a dispersed source, including the function of active filter to compensate the harmonics caused by nonlinear loads. The PV-AF system has merits not only to compensate harmonics caused by nonlinear loads but also to increase the utilization of PCS. This paper describes the grid-connected single phase PV-AF system and the PSCAD/EMTDC simulation results.

  • PDF

Theoretical Analysis and Control of DC Neutral-point Voltage Balance of Three-level Inverters in Active Power Filters

  • He, Yingjie;Liu, Jinjun;Tang, Jian;Wang, Zhaoan;Zou, Yunping
    • Journal of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.344-356
    • /
    • 2012
  • In recent years, multilevel technology has become an effective and practical solution in the field of moderate and high voltage applications. This paper discusses an APF with a three-level NPC inverter. Obviously, the application of such converter to APFs is hindered by the problem of the voltage unbalance of DC capacitors, which leads to system instability. This paper comprehensively analyzes the theoretical limitations of the neutral-point voltage balancing problem for tracking different harmonic currents utilizing current switching functions from the space vector PWM (SVPWM) point of view. The fluctuation of the neutral point caused by the load currents of certain order harmonic frequency is reported and quantified. Furthermore, this paper presents a close-loop digital control algorithm of the DC voltage for this APF. A PI controller regulates the DC voltage in the outer-loop controller. In the current-loop controller, this paper proposes a simple neutral-point voltage control method. The neutral-point voltage imbalance is restrained by selecting small vectors that will move the neutral-point voltage in the direction opposite the direction of the unbalance. The experiment results illustrate that the performance of the proposed approach is satisfactory.

Deep Learning based Rapid Diagnosis System for Identifying Tomato Nutrition Disorders

  • Zhang, Li;Jia, Jingdun;Li, Yue;Gao, Wanlin;Wang, Minjuan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.4
    • /
    • pp.2012-2027
    • /
    • 2019
  • Nutritional disorders are one of the most common diseases of crops and they often result in significant loss of agricultural output. Moreover, the imbalance of nutrition element not only affects plant phenotype but also threaten to the health of consumers when the concentrations above the certain threshold. A number of disease identification systems have been proposed in recent years. Either the time consuming or accuracy is difficult to meet current production management requirements. Moreover, most of the systems are hard to be extended, only detect a few kinds of common diseases with great difference. In view of the limitation of current approaches, this paper studies the effects of different trace elements on crops and establishes identification system. Specifically, we analysis and acquire eleven types of tomato nutritional disorders images. After that, we explore training and prediction effects and significances of super resolution of identification model. Then, we use pre-trained enhanced deep super-resolution network (EDSR) model to pre-processing dataset. Finally, we design and implement of diagnosis system based on deep learning. And the final results show that the average accuracy is 81.11% and the predicted time less than 0.01 second. Compared to existing methods, our solution achieves a high accuracy with much less consuming time. At the same time, the diagnosis system has good performance in expansibility and portability.

Requirements for Cerebrovascular Surgery in Comprehensive Stroke Centers in South Korea

  • Kim, Tackeun;Oh, Chang Wan;Park, Hyeon Seon;Lee, Kunsei;Lee, Won Kyung;Lee, Heeyoung
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.4
    • /
    • pp.478-484
    • /
    • 2018
  • Objective : Cerebrovascular disease (CVD) was the third most common cause of death in South Korea in 2014. Evidence from abroad suggests that comprehensive stroke centers play an important role in improving the mortality rate of stroke. However, surgical treatment for CVD is currently slightly neglected by national policy, and there is still regional imbalance in this regard. For this reason, we conducted a survey on the necessity of, and the requirements for, establishing regional comprehensive cerebrovascular surgery centers (CCVSCs). Methods : This investigation was performed using the questionnaire survey method. The questionnaire was consisted with two sections. The first concerned the respondent's opinion regarding the current status of demand and the regional imbalance of cerebrovascular surgery in South Korea. The second section asked about the requirements for establishing regional CCVSCs. We sent the questionnaire to 100 board members of the Korean Society of Cerebrovascular Surgeons. Results : Most experts agreed that cerebrovascular surgery patients were concentrated in large hospitals in the capital area, and 83.6% of respondents agreed that it was necessary to alleviate the regional imbalance of cerebrovascular surgery. With regards to personnel, over 90% of respondents answered that at least two neuro-vascular surgeons and two neuro-interventionists are necessary to establish a CCVSC. Regarding facilities, almost all respondents stated that each CCVSC would require a neuro-intensive care unit and hybrid operating room. The survey asked the respondents about 13 specific neurovascular surgical procedures and whether they were necessary for a regional CCVSC. In the questions about the necessity of cerebrovascular surgical equipment, all seven pieces of equipment were considered essential by all respondents. A further five pieces of equipment were considered necessary on site: computed tomographic angiography, magnetic resonance angiography, conventional angiography, surgical microscope, and surgical navigation. Our results may provide a basis for future policy regarding treatment of cerebrovascular disease, including surgery. Conclusion : Raising the comprehensiveness of treatment at a regional level would lower the national disease burden. Policies should be drafted regarding comprehensive treatment including surgery for cerebrovascular disease, and related support plans should be implemented.

Study of Dietary Fatty acids, Blood Fatty Acid Composition, and Immune Parameters in Atopic Dermatitis Patients (아토피 피부염 환자의 지방산 섭취와 혈중 지방산 조성 및 면역 지표에 관한 연구)

  • Chung Yun Mi;Kim Sujung;Kim Nack-In;Lee Eun-Young;Choue Ryowon
    • Journal of Nutrition and Health
    • /
    • v.38 no.7
    • /
    • pp.521-532
    • /
    • 2005
  • The prevalence of atopic dermatitis (AD) continues to rise in industrialized countries related to Western lifestyle, including dietary habits, especially imbalance of intake of dietary fatty acids. The purpose of this study was to evaluate the dietary fatty acids and the assess the blood fatty acid composition and immune parameters in AD patients. AD (n = 50) patients and gender ${\cdot}$ age matched healthy controls (HC) were studied in case-control clinical trail. Current fatty acids intake status was determined by 3-day food record method. Blood sample were collected from 30 subjects in each group and blood fatty acid composition and immune parameters were analysed. AD patients consumed less PUFA and their n-6/n-3 PUFA ratio was higher than that of HC. Both the ratios of PUFA and MUFA were positively correlated with SCORAD in AD patients (p < 0.05). In the AD patients, there were abnormalities in the fatty acid composition of the RBC and WBC, SFA being significantly high and most n-3 PUFA being significantly low. Moreover, both the ratios of EPA and DHA in WBC were negatively correlated with dietary n-6/n-3 PUFA ratio in AD patients (p < 0.05). Serum total IgE and IL-4 levels of AD patients increased significantly compared with the levels of HC (p < 0.01). Ratios of monocyte and eosinophil in WBC of AD patients increased significantly compared with the levels of HC including total WBC count (p < 0.01), and ratios of Iymphocyte and basophil in WBC of AD patients decreased significantly compared with the levels of HC (p < 0.05). Moreover, the ratios of eosinophil in WBC were positively correlated with dietary P/M ratio (p < 0.05), and the ratios of monocyte in WBC were positively correlated with n-6/n-3 PUFA ratio (p < 0.05) in AD patients. This results indicated that AD patients had significantly high intake of dietary n-6/n-3 PUFA compared with HC. Imbalance of intake of dietary fatty acids affected fatty acid compositions in the RBC and WBC, and these lead to immune imbalance and grow worse of AD.

Rotordynamic Performance Measurements and Predictions of a FCEV Air Compressor Supported on Gas Foil Bearings (가스 포일 베어링으로 지지되는 연료전지 전기자동차용 공기압축기의 회전체동역학적 성능 측정 및 예측)

  • Hwang, Sung Ho;Moon, Chang Gook;Kim, Tae Ho;Lee, Jongsung;Cho, Kyung Seok;Ha, Kyoung-Ku;Lee, Chang Ha
    • Tribology and Lubricants
    • /
    • v.35 no.1
    • /
    • pp.44-51
    • /
    • 2019
  • The paper presents the rotordynamic performance measurements and model predictions of a fuel cell electric vehicle (FCEV) air compressor supported on gas foil bearings (GFBs). The rotor has an impeller on one end and a thrust runner on the other end. The front (impeller side) and rear (thrust side) gas foil journal bearings (GFJBs) are located between the impeller and thrust runner to support the radial loads, and a pair of gas foil thrust bearings are located on both sides of the thrust runner to support the axial loads. The test GFJBs have a partial arc shim foil installed between the top foil and bump strip layers to enhance hydrodynamic pressure generation. During the rotordynamic performance tests, two sets of orthogonally installed eddy-current displacement sensors measure the rotor radial motions at the rotor impeller and thrust ends. A series of speed-up and coast-down tests to 100k rpm demonstrates the dominant synchronous (1X) rotor responses to imbalance masses without noticeable subsynchronous motions, which indicates a rotordynamically stable rotor-GFB system. Finite element analysis of the rotor determines the rotor free-free (bending) natural modes and frequencies well beyond the maximum rotating frequency. The predicted damped natural frequencies and damping ratios of the rotor-GFB system reveal rotordynamic stability over the speeds of interest. The imbalance response predictions show that the predicted critical speeds and rotor amplitudes strongly agree with the test measurements, thus validating the developed rotordynamic model.

방사선 치료 장치 및 인력에 관한 연구

  • Kim, Yu-Hyeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.5 no.1
    • /
    • pp.47-56
    • /
    • 1992
  • This report presents the date obtained in a 1990 survery al radiation oncology identified by KSTRO. This study was done to find out the status of current use of the radation thrapy equipments, personnels, utilization of equipments and orther problems in the field of radiation oncology department in korea. Our discussion addresses the areas of regional imbalance in the distribution of megavolage units, buying and selecting the units, improving of quality in radiation treatments. There is increasing use of linear accelerators, simulators, treatment planning computers. The use of Cp-60 units has been prohressively decreasing. And slowly improving, numbers of physicians, physicists, and technologists when compared with the 1988. A total of 51 megavoltage units were identified, giving a ratio of 1.88 technologists/ megavoltage units. We treat average 23.0 patients by megavoltage units.

  • PDF

3-Phase Hybrid Series Active Power Filter with Instantaneous Voltage Fluctuations Compensation (순간전압변동 보상 기능을 갖는 3상 하이브리드형 직렬 능동전력필터)

  • 이승요
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.739-743
    • /
    • 2000
  • With significant development of power electronics technology the proliferation of nonlinear loads such as such as static power converters has deteriorated power quality in power transmission distribution systems. Notably voltage harmonics resulting from current harmonies produced by the nonlinear loads have become a serious problem in many systems Moreover momentary interruptions and voltage sags are responsible for many of the power quality problems found in typical industrial plants. Int his paper proposed 3 phase hybrid series active power filter is not only for harmonic compensation but also for harmonic isolation between supply and load and for voltage regulation and imbalance compensation Through computer simulations we have verified the effectiveness of the proposed system.

  • PDF

Detection of Mechanical Imbalances of Induction Motors with Instantaneous Power Signature Analysis

  • Kucuker, Ahmet;Bayrak, Mehmet
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1116-1121
    • /
    • 2013
  • Mechanical imbalances are common mechanical faults in induction motors. Vibration monitoring techniques have been widely used for the diagnosis of mechanical faults in induction motors, but electrical detection methods have been preferred in recent years. For many years, researchers have concentrated on the Motor Current Signature Analysis (MCSA). This paper examines the effect of mechanical imbalances to induction machine electrical parameters. Instantaneous Power Signature Analysis (IPSA) technique used to detect these faults. In the paper, a full analysis of the proposed technique is presented, and experimental results for healthy and faulty motors have been shown and discussed.