• 제목/요약/키워드: Current distribution imaging

검색결과 59건 처리시간 0.026초

PATIAL DISTRIBUTION OF STAR FORMATION ACTIVITY ON NGC 253 BY FIR AND RADIO EMISSION LINES

  • Takahashi, H.;Matsuo, H.;Nakanishi, K.
    • 천문학논총
    • /
    • 제27권4호
    • /
    • pp.261-262
    • /
    • 2012
  • The aim of this research is to reveal the spatial distribution of the star formation activity of nearby galaxies by comparing CO molecular emission lines with the large area observation in far-infrared (FIR) lines. We report the imaging observations of NGC 253 by FIR forbidden lines via FIS-FTS and CO molecular lines from low to high excitation levels with ASTE, which are good tracers of star forming regions or photo-dissociation regions, especially spiral galaxies, in order to derive the information of the physical conditions of the ambient interstellar radiation fields. The combination of spatially resolved FIR and sub-mm data leads to the star formation efficiency within galaxy. The ratio between the FIR luminosity and molecular gas mass, $L_{FIR}/M_{H_2}$, is expected to be proportional to the number of stars formed in the galaxy per unit molecular gas mass and time. Moreover the FIR line ux shows current star formation activity directly. Furthermore these can be systematic and statistical data for star formation history and evolution of spiral galaxies.

전기 임피던스 단층촬영법에서 TSVD 기반의 역문제 해법의 개발 (Development of Inverse Solver based on TSVD in Electrical Impedance Tomography)

  • 김봉석;김창일;김경연
    • 전자공학회논문지
    • /
    • 제54권4호
    • /
    • pp.91-98
    • /
    • 2017
  • 전기 임피던스 단층촬영 기법은 도메인의 표면에 부착된 전극들을 통해 주입된 전류와 측정된 전압 데이터를 기반으로, 미지의 도전율 분포를 복원하는 비파괴 기술이다. 이 논문에서는 전기 임피던스 단층촬영법에서 일반적 Tikhonov 조정을 갖는 역문제를 풀고 도전율 분포를 복원하기 위해 절단된 특이값 분해 기반의 역문제 해법을 제안하였다. 역문제 계산시간을 줄이기 위해 일반 조정행렬을 역행렬 항목에서 분리시키고 절단된 특이값 분해 방법을 적용하였다. 제안한 방법의 성능을 검증하기 위해 모의실험과 팬텀실험을 수행하고 복원결과를 비교하였다.

Fast Noise Reduction Approach in Multifocal Multiphoton Microscopy Based on Monte-Carlo Simulation

  • Kim, Dongmok;Shin, Younghoon;Kwon, Hyuk-Sang
    • Current Optics and Photonics
    • /
    • 제5권4호
    • /
    • pp.421-430
    • /
    • 2021
  • The multifocal multiphoton microscopy (MMM) enables high-speed imaging by the concurrent scanning and detection of multiple foci generated by lenslet array or diffractive optical element. The MMM system mainly suffers from crosstalk generated by scattered emission photons that form ghost images among adjacent channels. The ghost image which is a duplicate of the image acquired in sub-images significantly degrades overall image quality. To eliminate the ghost image, the photon reassignment method was established using maximum likelihood estimation. However, this post-processing method generally takes a longer time than image acquisition. In this regard, we propose a novel strategy for rapid noise reduction in the MMM system based upon Monte-Carlo (MC) simulation. Ballistic signal, scattering signal, and scattering noise of each channel are quantified in terms of photon distribution launched in tissue model based on MC simulation. From the analysis of photon distribution, we successfully eliminated the ghost images in the MMM sub-images. If the priori MC simulation under a certain optical condition is established at once, our simple, but robust post-processing technique will continuously provide the noise-reduced images, while significantly reducing the computational cost.

작동중인 모스 전계 효과 트랜지스터 단면에서의 상대온도 및 전위 분포 측정 (Cross Sectional Thermal and Electric Potential Imaging of an Operating MOSFET)

  • 권오명
    • 대한기계학회논문집B
    • /
    • 제27권7호
    • /
    • pp.829-836
    • /
    • 2003
  • Understanding of heat generation in semiconductor devices is important in the thermal management of integrated circuits and in the analysis of the device physics. Scanning thermal microscope was used to measure the temperature and the electric potential distribution on the cross-section of an operating metal-oxide-semiconductor field-effect transistor (MOSFET). The temperature distributions were measured both in DC and AC modes in order to take account of the leakage current. The measurement results showed that as the drain bias was increased the hot spot moved to the drain. The density of the iso-potential lines near the drain increased with the increase in the drain bias.

Dental PACS development in Korea

  • Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • 제38권4호
    • /
    • pp.189-194
    • /
    • 2008
  • Picture archiving and communication system (PACS) is an image information technology system for the transmission and storage of medical images. In Korea the first full PACS was installed at Samsung Medical Center in 1994, but, the rate of distribution was very slow. The government's approval for the medical insurance reimbursement for full PACS examinations in November 1999 became the turning point. Thereafter the number of hospitals with full PACS has steeply increased. In September of this year, PACS was installed at 906 medical institutes, including most of university hospitals and general hospitals. The first full dental PACS was installed at Wonkwang University Dental Hospital in 2002. Now ten out of eleven university dental hospitals implemented full dental PACS. The current status and technological factors of dental PACS in Korean university dental hospitals and the future perspectives of dental PACS are described. (Korean J Oral Maxillofac Radiol 2008; 38: 189-94)

  • PDF

Tracing the first galaxies with the James Webb Space Telescope

  • Tacchella, Sandro
    • 천문학회보
    • /
    • 제46권2호
    • /
    • pp.41.2-41.2
    • /
    • 2021
  • I will start with presenting new results on the stellar populations of galaxies at a redshift of z=9-11, when the universe was only a few hundred million years old. By combining Hubble Space Telescope observations with Spitzer imaging data, I will show how challenging it is currently to measure basic physical properties of these objects such as star-formation rates, stellar masses and stellar ages. In particular, the current measurements greatly depend on the assumptions (priors) for the spectral energy distribution modeling. Finally, I will discuss how the James Webb Space Telescope (JWST) will revolutionize this field next year and allow us to probe and characterize the first generation of galaxies in much greater detail. Specifically, I will present an overview of the JWST Advanced Deep Extragalactic Survey (JADES), a joint program of the JWST/NIRCam and NIRSpec Guaranteed Time Observations (GTO) teams involving 950 hours of observation.

  • PDF

운전조건에 따른 공기보조 분사기의 Sauter 평균입경에 대한 고찰 (Investigation on the Sauter Mean Diameter of an Air-Assisted Fuel Injector -Operating Parameter Consideration)

  • 장창수;최상민
    • 한국자동차공학회논문집
    • /
    • 제8권4호
    • /
    • pp.42-50
    • /
    • 2000
  • Drop size distribution of an air-assisted fuel injector(AAFI) was investigated. Influence of parameters such as ambient air density supply pressure and air-liquid mass ratio(ALR) was examined through both measurement and analysis. The Sauter mean diameter$D_{32}$ varied from 9 to 25$\mu$m throughout all experimental conditions. An empirical correlation for droplet size was obtained. Analytical correlations for predicting $D_{32}$ with respect to operating conditions were also derived through energy consideration and introduction of a simplified model of the from the empirical fitting was adapted to the original equation the proposed correlation in this study matched more closely with measured results. The current correlation exhibited a favorable study matched more closely with measured results. The current correlation exhibited a favorable prediction for $D_{32}$ compared to that by the empirical correlation at selected experimental conditions so that it may be used to predict atomization performance of the AAFI at operating conditions which was not covered in the measurements. After validation the analytical equation was applied to survey the feasible operating conditions for gasoline direct injection application.

  • PDF

Application of Terahertz Spectroscopy and Imaging in the Diagnosis of Prostate Cancer

  • Zhang, Ping;Zhong, Shuncong;Zhang, Junxi;Ding, Jian;Liu, Zhenxiang;Huang, Yi;Zhou, Ning;Nsengiyumva, Walter;Zhang, Tianfu
    • Current Optics and Photonics
    • /
    • 제4권1호
    • /
    • pp.31-43
    • /
    • 2020
  • The feasibility of the application of terahertz electromagnetic waves in the diagnosis of prostate cancer was examined. Four samples of incomplete cancerous prostatic paraffin-embedded tissues were examined using terahertz spectral imaging (TPI) system and the results obtained by comparing the absorption coefficient and refractive index of prostate tumor, normal prostate tissue and smooth muscle from one of the paraffin tissue masses examined were reported. Three hundred and sixty cases of absorption coefficients from one of the paraffin tissues examined were used as raw data to classify these three tissues using the Principal Component Analysis (PCA) and Least Squares Support Vector Machine (LS-SVM). An excellent classification with an accuracy of 92.22% in the prediction set was achieved. Using the distribution information of THz reflection signal intensity from sample surface and absorption coefficient of the sample, an attempt was made to use the TPI system to identify the boundaries of the different tissues involved (prostate tumors, normal and smooth muscles). The location of three identified regions in the terahertz images (frequency domain slice absorption coefficient imaging, 1.2 THz) were compared with those obtained from the histopathologic examination. The tissue tumor region had a distinctively visible color and could well be distinguished from other tissue regions in terahertz images. Results indicate that a THz spectroscopy imaging system can be efficiently used in conjunction with the proposed advanced computer-based mathematical analysis method to identify tumor regions in the paraffin tissue mass of prostate cancer.

위성원격탐사에 의한 동중국해 재부상 부유사의 계절적 수평분포 특성 (Satellite Remote Sensing to Monitor Seasonal Horizontal Distribution of Resuspended Sediments in the East China Sea)

  • 이나경;서영상;김영섭
    • 한국지리정보학회지
    • /
    • 제6권3호
    • /
    • pp.151-161
    • /
    • 2003
  • 본 연구에서는 최근 해양, 대기, 육지환경을 동시에 관측할 수 있는 미국 첨단관측 위성 Terra/MODIS(moderate-resolution imaging spectroradiometer) 자료와 동중국해 북부해 역에의 현장 관측치를 이용하여 동중국해에서 탁한 해수의 수평 분포에 대한 동 하계 변동 규모를 정량화하고자 하였다. 국립수산과학원에서 2001년 6월부터 실시간 직접 수신한 MODIS 위성의 36개 채널 자료 중, 공간해상도가 250m인 채널 1(620~670nm) 및 공간해상도 500m인 채널 4(545~565nm)와 채널 3(459~479nm)을 합성한 RGB(red, green, blue) 디지털 영상자료를 이용하였다. 중국 연안측과 같이 수심이 얕은 동중국해역에서 발생되는 탁수의 수평 공간 분포 영역은 동계의 경우 강한 풍속과 수온약층의 소멸현상 등으로 수평면적이 평균 $232,000km^2$였다. 하계의 경우 비교적 약한 풍속과 강한 수온약층의 존재 등으로 수평면적이 평균 $71,000km^2$로 나타나, 동계 탁수의 수평적 분포 면적이 하계보다 약 3배 커지는 것으로 나타났다. 탁수의 수평면적 변동은 하계의 경우 10~20m 등수심선과, 동계의 경우 50m 등수심과 대략적으로 일치하는 분포를 보였다. 동계는 50m 이천까지의 수심에서 재부상한 부유물질이 표층에서 바람 또는 이류에 의해 50m 수심보다 깊은 해역의 표층으로 수평확산되어 탁수가 단지 표층에 국한되어 분포하는 것으로 추정되었다.

  • PDF

Analysis of the Shoulder and Elbow Section of the Korean Orthopedic In-training Examination

  • Kim, Joon Yub;Jung, Myung Gon;Kwon, Ki Bum;Chung, Seok Won
    • Clinics in Shoulder and Elbow
    • /
    • 제19권2호
    • /
    • pp.67-72
    • /
    • 2016
  • Background: The aim of this study was to analyze the questions in the shoulder and elbow section of the Korean Orthopaedic In-Training Examination (KOITE) and compare them with those of the US Orthopaedic In-Training Examination (US OITE). Methods: Twenty-nine questions in the shoulder and elbow section of the KOITE from 2010 to 2014 were analyzed and compared with those of the US OITE (80 questions) by literature review. A thorough analysis of the contents was performed after categorizing as topics, diagnostic tools, treatment modalities, taxonomic classification, and references. Results: The shoulder and elbow section of the KOITE was 5.8% weight which was similar to the US OITE (5.9%). The most commonly appearing topic was anterior labral injury (17.2%) on the KOITE compared to instability and arthritis (21.3%, each) on the US OITE. Magnetic resonance imaging was most frequently appeared imaging modality on the KOITE (41.0%) compared to the radiograph on the US OITE (43.0%). The Latarjet procedure was the most commonly asked treatment modality (22.2%) on the KOITE, whereas arthroplasty (33.3%) on the US OITE. The KOITE showed an even taxonomic classification distribution compared to the US OITE. Campbell's operative orthopaedics covered 96.6% questions as a reference on the KOITE compared to the Journal of Bone and Joint Surgery, American Volume on the US OITE, which covered 45.0%. Conclusions: This specific analysis shows us current trends of the shoulder and elbow section of the KOITE and it might be developed for use in the educational curricula for the trainee.