• Title/Summary/Keyword: Current conditioning

검색결과 360건 처리시간 0.03초

A Seamless Transfer Algorithm Based on Frequency Detection with Feedforward Control Method in Distributed Generation System

  • Kim, Kiryong;Shin, Dongsul;Lee, Jaecheol;Lee, Jong-Pil;Yoo, Dong-Wook;Kim, Hee-Je
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.1066-1073
    • /
    • 2015
  • This paper proposes a control strategy based on the frequency detection method, comprising a current control and a feed-forward voltage control loop, is proposed for grid-interactive power conditioning systems (PCS). For continuous provision of power to critical loads, PCS should be able to check grid outages instantaneously. Hence, proposed in the present paper are a frequency detection method for detecting abnormal grid conditions and a controller, which consists of a current controller and a feedforward voltage controller, for different operation modes. The frequency detection method can detect abnormal grid conditions accurately and quickly. The controller which has current and voltage control loops rapidly helps in load voltage regulation when grid fault occurs by changing reference and control modes. The proposed seamless transfer control strategy is confirmed by experimental results.

냉동냉장설비의 수요예측에 관한 연구 (Study on Demand Prediction of Cold Storage Facilities)

  • 손창효;오후규
    • 설비공학논문집
    • /
    • 제23권9호
    • /
    • pp.587-594
    • /
    • 2011
  • This paper describes the investigation on current state of cold storage facilities, and analysis on the demand prediction in the near future. And based on the analysis results, we prospect the scale of cold storage facilities in the near future. The main analysis results are summarized by the followings ; The present circumstances of cold storage facility are determined by investigating actual loading capacity, average stock amounts, and return number of cold storage facility. From the results, the present situation for cold storage facility is about 3% over. It is found that the average stock amounts increase gradually, and accordingly that the demand of cold storage facility is predicted to be increased, resulting that the capacity of cold storage facilities in 2013 expects to reach up to 5,250,000 ton. It is considered that the results of demand prediction has significant implications on the management of cold storage facility in the near future.

분리막 제습공조시스템의 잠열부하 저감효과 예측 (Prediction of Latent Heat Load Reduction Effect of the Dehumidifying Air-Conditioning System with Membrane)

  • 정용호;박성룡
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.15-20
    • /
    • 2017
  • The summer climate is very hot and humid in Korea. The humidity is an important factor in determining thermal comfort. Recently, the research for dehumidification device development has been attempted to save energy that is required for the operation of the current dehumidifiers on the market. Existing dehumidification systems have disadvantages such as wasting energy to drive a compressor. Meanwhile, dehumidification systems with membranes can dehumidify humid air without increasing the dry bulb temperature so it doesn't have to consume cooling energy. In this paper, the cooling energy savings was studied when a dehumidification system was applied in a model building instead of a chiller. The sensible heat load was almost the same result, but the latent heat load was decreased by 38.9% and the total heat load was decreased by 8.5%. As a result, electric energy used to drive the compressor in a chiller was saved by applying a membrane air-conditioning system instead.

고속도로 요금소 주변의 대기오염 현황에 관한 연구 (A study on the condition of air pollution near tollbooths on highway)

  • 김신도;박성규;봉춘근;김종호;강혜진;이의상
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.359-368
    • /
    • 1999
  • The outdoor and indoor air quality surrounding highway have been measured, and the study on the design of the booth shape and the air-conditioning system also has been carried out. For the first step of the work, the air quality at the Seoul tollgate on the Kyeong-bu highway was monitored over a year. The measured indoor air quality shows seasonal average concentration 85.6-92.1ppb of >;$NO_2$and the $SO_2$and CO lower than the EAQS(Environmental Air Quality Standards). The measured TSP concentration was much higher than the EAQS. In conclusion, there is necessity to improve the working environment of the tollbooths on highways, and the current air-conditions need to be modify for the purpose. In the process of modifying the air-conditioning system, particulate pollutants needs to be considered processing and the priority needs to be put on the booths for big vehicles.

  • PDF

PEM 연료전지 평행류 채널에서 Baffle의 영향 (Effects of baffles through the parallel flow channel in a PEM fuel cell)

  • 오창묵;이규정
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.9-14
    • /
    • 2008
  • The effects of baffles in PEM fuel cell with parallel flow channel has been simulated by using conmmercial program. The simulation has been conducted through the channel and there are four different heights of baffles, No Baffle($H_b$=0), Partially Blocked Baffle(0.25, 0.5, 0.75), Fully Blocked Baffle(1) conditions. The result shows that current density changes while placing a baffle at the various positions along the channel. Current density with a single baffle is higher than that without baffle and current density using Fully Blocked Baffle(FBB) is much higher than current density using Partially Blocked Baffle(PBB). When the baffle is closer to outlet of the channel, current density increases. It is found that pressure is related to current density. If the pressure is higher, the better performance will be expected.

  • PDF

3레벨 태양광 PCS에서의 누설전류 저감기법 개발 (Development of Leakage Current Reduction Method in 3-Level Photovoltaic PCS)

  • 한성은;조종민;안현성;차한주
    • 전력전자학회논문지
    • /
    • 제24권1호
    • /
    • pp.56-61
    • /
    • 2019
  • In this study, a reduction method of leakage current in a three-level photovoltaic power-conditioning system (PCS) is proposed and verified by simulation and experiment. Leakage current generation is analyzed through an equivalent model of the common mode voltage considering a significant parasitic capacitance existing between the photovoltaic array and ground. A leakage current reduction method using pulse-width modulation (PWM) method is also proposed, and a 10-kW three-level photovoltaic PCS simulation and experiment is performed with a $1{\mu}F$ parasitic capacitor based on 100 nF/kW. The proposed method using the PWM method is verified to reduce the leakage current by 73% compared with the conventional PWM method.

The Effect of Transformer Leakage Inductance on the Steady State Performance of Push-pull based Converter with Continuous Current

  • Chen, Qian;Zheng, Trillion Q.;Li, Yan;Shao, Tiancong
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.349-361
    • /
    • 2013
  • As a result of the advantages such as high efficiency, continuous current and high stability margin, push-pull converter with continuous current (PPCWCC) is competitive for battery discharge regulator (BDR) which plays an important role in power conditioning unit (PCU). Leakage inductance yields current spike in low-ripple current of PPCWCCs. The operating modes are added due to leakage inductance. Therefore the steady state performance is affected, which is embodied in the spike of low-ripple current. PPCWCCs which are suitable for BDR can be separated into three types by current spike characteristics. Three representative topologies IIs1, IIcb2 and Is3 are analyzed in order to investigate the factors on the magnitude and duration of spike. Equivalent current sampling method (ECSM) which eliminates the sampling time delay and achieves excellent dynamic performance is adopted to prevent the spike disturbance on current sampling. However, ECSM reduces the sampling accuracy and telemetry accuracy due to neglecting the spike. In this paper, ECSM used in PPCWCCs is summarized. The current sampling error is analyzed in quality and quantity, which provides the foundation for offsetting and enhancing the telemetry accuracy. Finally, current sampling error rate of three topologies is compared by experiment results, which verify the theoretical analysis.

전류정보 기반의 파워 윈도우용 안티핀치 시스템의 전류 임계값 자동 설정 및 성능 분석 (Performance Analysis and Automatic Configuration of Threshold on Anti-Pinch System Based on Current Information for Power Windows)

  • 박승섭;정석권
    • 동력기계공학회지
    • /
    • 제21권5호
    • /
    • pp.63-70
    • /
    • 2017
  • This paper deals with anti-pinch system based on current information which prevents some risks for trapping, squeezing or injury to people in smart window on vehicles. Automatic configuration of current threshold is suggested to recognize pinch states in the current based anti-pinch system. Also, some factors affecting to the squeezing force were analyzed by some experimental results and simulations. The validity of the suggested system was verified to satisfy the strengthened American safety regulation, FMVSS 118-S5, through some experimental results.

PV-AC 모듈형 플라이백 인버터의 전류 센서리스 MPPT제어기법 (Current sensorless MPPT for PV-AC module flyback inverter)

  • 최봉연;김영호;지용혁;이태원;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.49-50
    • /
    • 2012
  • Maximum power point tracking(MPPT) algorithm is needed in PV AC module power conditioning system because of the nonlinear current-voltage characteristics. Conventional MPPT algorithm is required to know PV-module output current and voltage. Thus, PV-AC module must have voltage and current sensor. In this paper, a current-sensorless MPPT algorithm, which uses only the voltage sensor, is presented for Flyback inverter.

  • PDF