• Title/Summary/Keyword: Current Transfer

Search Result 2,152, Processing Time 0.032 seconds

Analysis of Safety Distance and Maximum Permissible Power of Resonant Wireless Power Transfer Systems with Regard to Magnetic Field Exposure

  • Park, Young-Min;Byun, Jin-Kyu
    • Journal of Magnetics
    • /
    • v.20 no.4
    • /
    • pp.450-459
    • /
    • 2015
  • In this paper, the safety distances and maximum permissible power (MPP) of resonant wireless power transfer systems are defined and derived with regard to human exposure to electromagnetic field (EMF). The definition is based on the calculated induced current density and electric field in the standard human model located between the transmitting and receiving coil. In order to avoid the adverse health effects such as stimulation of nerve tissues, the induced current and electric field must not exceed the basic restriction values specified in EMF safety guidelines. The different combinations of diameters of the coils and the distance between the two coils are investigated and their effects are analyzed. Two versions of EMF safety guidelines (ICNIRP 1998 and ICNIRP 2010) are used as bases for safety distance calculation and the difference between the two guidelines are discussed.

Calculation of the Eddy Current Effect Transfer Function Using the Finite Element Method (유한요소법을 이용한 와전류 영향 전달함수의 계산)

  • Lee, S.Y.;Khang, H.S.;Yi, J.H.;Mun, C.W.;Lee, K.S.;Cho, M.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.92-93
    • /
    • 1998
  • In this study, we have established the technique to estimate the gradient waveforms distorted by the eddy current in MRI. After obtaining the eddy current effect transfer function using the finite element method, we have used the transfer function to estimate the output gradient waveforms at any points inside the imaging region. We also present experimental results to be compared with estimated ones.

  • PDF

Analysis of Metal Transfer using Dynamic Force Balance Model in GMAW (동적 힘 평형 모델을 이용한 GMA 용접의 용적이행 해석)

  • 최재형;이지혜;유중돈
    • Journal of Welding and Joining
    • /
    • v.19 no.4
    • /
    • pp.399-405
    • /
    • 2001
  • A dynamic force balance model is proposed in this work as an extension of the previous static force balance model to predict metal transfer in arc welding. Dynamics of a pendant drop is modeled as the second order system, which consists of the mass, spring and damper. The spring constant of a spherical drop at equilibrium is derived in the closed-form equation, and the inertia force caused by drop vibration is included in the drop detaching condition. While the inertia force is small in the low current range, it becomes larger than the gravitational force with current increase. The inertia force reaches half of the electromagnetic force at transition current, and has considerable effects on drop detachment. The proposed dynamic force balance model predicts the detaching drop size more accurately than the static force balance model.

  • PDF

Zero-Phase Angle Frequency Tracking Control of Wireless Power Transfer System for Electric Vehicles using Characteristics of LCCL-S Topology (LCCL-S 토폴로지 특성을 이용한 전기자동차용 무선충전시스템의 ZPA 주파수 추종 제어)

  • Byun, Jongeun;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.5
    • /
    • pp.404-411
    • /
    • 2020
  • Inductive power transfer (IPT) systems for electric vehicles generally require zero phase angle (ZPA) frequency tracking control to achieve high efficiency. Current sensors are used for ZPA frequency tracking control. However, the use of current sensors causes several problems, such as switching noise, degrading control performance, and control complexity. To solve these problems, this study proposes ZPA frequency tracking control without current sensors. Such control enables ZPA frequency tracking without real-time control and achieves stable zero voltage switching operation closed to ZPA frequency within all coupling coefficient and load ranges. The validity of the proposed control algorithm is verified on LCCL-S topology with a 3.3 kW rating IPT experimental test bed. Simulation verification is also performed.

The Metal Detection using Primary Current in Contact-less Power Supply (무접점 전원공급 시 1차측 전류를 이용한 금속 물질 검출에 관한 연구)

  • Kim, Yu-Seok;Yu, Joo-Hee;Kim, Choon-Sam;Sung, Won-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.445-452
    • /
    • 2012
  • The impurity detection method applied to existing discriminated the normality(R, L, C) and impurity(Metal) load using mutual RFID/ID method in the contactless power supply in which the primary side and the secondary side are completely separation by using the contactless transformer. However, this kind of system is caused the high cost of the system and complexity of control. Therefore, in this paper was proposed the contact-less power transfer using the primary current that determine normality or impurity load by compare the primary current Amplitude to reference quantity value and design the 3[W] contact-less power transfer and conduct an experiment for demonstrate the validity.

Measures of Real Estate Taxation in the Classify Income (현행 법률상 분류소득인 부동산양도소득세의 정책방안)

  • Yoon, Deok-Byeong
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.2
    • /
    • pp.137-142
    • /
    • 2017
  • The purpose of this study tried theoretical review on the current Transfer Income Tax system, and review on current Korean Transfer Income Tax system, to derive the inherent problems in Korean Transfer Income Tax system. This study presents the improving measures thereto.The transfer income earned by any individual person is taxed as the Transfer Income Tax pursuant to the Income Tax Act, and the transfer income earned by any legal person is taxed as the transfer income on transfer gain on land etc, pursuant to the Corporate Tax Act. In case of the Transfer Income Taxes earned by individual persons, land and buildings comprise most of the taxable items of the Transfer Income Tax. This study limits the scope of study to the Transfer Income Tax on land and building as the major taxable item, rather than all the Transfer Income Tax taxed to individual taxpayers. The outcomes of this are expected to rationly improvement the real estate taxation in accordance with the principle of tax law.

Non-Equilibrium Green Function Method in Spin Transfer Torque

  • You, Chun-Yeol
    • Journal of Magnetics
    • /
    • v.12 no.2
    • /
    • pp.72-76
    • /
    • 2007
  • We investigate the spin transfer torque in metallic multilayer system by employing Keldysh non-equilibrium Green function method. We study the dependences of the spin transfer torque on the detailed energy configuration of ferromagnetic, spacer, and lead layers. With Keldysh non-equilibrium Green function method applied to a single band model, we explore spin transfer torque effect in various layer structures and for various material parameters.

Treatment of Heavy Metal Wastewater Bed Electrode Reactor by a Fluidized 1. Distribution of Local Mass Transfer Coefficients on the Current Feeder (유동층 전극반응기를 이용한 중금속폐수의 처리에 관한 연구 1. 전류공급원에서의 국부물질전달계수의 분포)

  • 황영기;정은혁
    • Journal of Environmental Science International
    • /
    • v.6 no.1
    • /
    • pp.1-8
    • /
    • 1997
  • Varing the flow velocity of solution and particle diameter, the mass transfer coefficient of the local electrode on current feeder has been measured in an empty flow reactor, an inert fluidized bed electrode reactor, and an active fluidized bed electrode reactor. It had its maximium value when the bed porosity was 0.6 to 0.65 and decreased with in- creasing the height of local electrode. The mass transfer coefficient was found to be high especially when higher particle was fluidized. Electrochemical deposition of copper dissolved in the synthesized wastewater has been performed in the active fluidized bed electrode reactor. The deduction rate was higher than 90% and the residual concentration of copper decreased to less than 5ppm.

  • PDF

Enhanced Boiling Heat Transfer of Water Using Multi-Stage Electroplating Technique (전기 다단 도금법을 이용한 물의 핵비등열전달 촉진 실험)

  • Cho, Dae-Gwan;You, Seung-Mun;Lee, Joon-Sik
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1590-1596
    • /
    • 2003
  • The experiments of boiling heat transfer were performed to investigate the boiling enhancement in saturated water by using multi-stage electroplated surface. In order to optimize the boiling performance, current flux and duration in multi-stage electroplating were varied. Current flux, 2 $A/12cm^2$ and 0.33 $A/cm^2$, and duration ranging from 15 second to 50 second are considered. The results showed that multi-stage electro plated surfaces generate enhancement of boiling parameters such as boiling incipient superheat, boiling heat transfer coefficient, and critical heat flux compared to plain surface. The SEM images of the coated surfaces were captured to examine the structure of porous surface, which provides the enhancement of boiling heat transfer.

  • PDF

Dynamic Analysis of Metal Transfer using VOF Method in GMAW (II) - Short Circuit Transfer Mode - (VOF 방법을 이용한 GMA 용접의 금속 이행에 관한 동적 해석 (II) - 단락 이행 모드의 해석 -)

  • 최상균;고성훈;유중돈;김희진
    • Journal of Welding and Joining
    • /
    • v.15 no.3
    • /
    • pp.47-55
    • /
    • 1997
  • Dynamic characteristics of the short circuit mode are investigated using the Volume of Fluid (VOF) method. When the initial molten drop volume, contact area and wire feed rate are given, rate change of the molten bridge profiles, pressure and velocity distributions are predicted. The electromagnetic force with proper boundary conditions are included in the formulation to consider the effects of welding current. It is found that the molten metal is transferred to the weld pool mainly due to the pressure difference caused by the curvatures in the initial stage, and electromagnetic force becomes dominant factor in the final stage of short circuit transfer. Necking occurs at the contact position between the molten drop and weld pool, and the initial molten drop volume and welding current have significant effects on break-up time.

  • PDF