• 제목/요약/키워드: Current State Analysis

검색결과 1,851건 처리시간 0.046초

고온ㆍ고압 아크 플라즈마 하에서의 정상상태 노즐용삭 해석 기술 (Steady State Analysis of Nozzle Ablation Under High Temperature and High Pressure Arc Plasma)

  • 이병윤;송기동;정진교;박경엽
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권9호
    • /
    • pp.395-399
    • /
    • 2003
  • In this paper, physical phenomena which are related to the high temperature and high pressure arc plasma generated during the fault current interruption by SF6 gas circuit breakers are reviewed. In particular, in order to analyze nozzle ablation induced by the heats transferred to the surface of the poly-tetrafluoroethylene(PTFE) nozzle through arc radiation, a governing equation for the calculation of PTFE concentration is added to the governing equations for SF6 arc Plasma analysis. The proposed method is applied to the steady state analysis of $SF_6$ arc plasma generated by direct current taking account of the nozzle ablation and the results are presented.

An Analysis of Menswear Brands in the Current Domestic Fashion Market

  • Jang, Eunyoung
    • 패션비즈니스
    • /
    • 제19권6호
    • /
    • pp.101-111
    • /
    • 2015
  • This study aims to analyze the current state of menswear in the domestic fashion market and the trend of new menswear brands. In addition to this, a comparative analysis of domestic and foreign menswear brands will be done to provide baseline data for the domestic brands in regards to strategic direction in the coming years. The study used reports published by Samsungdesign.net, which provided trends of 110 new brands from 2005 to 2014, in order to analyze the trends of new menswear brands launched during that period. Menswear brand information in the Korean Fashion Brand Annual, of which there were 168, were utilized to research the current state of the brands in the domestic market. As a results, menswear is expected to become more sensitive to trends and designs thanks to steady launchings of menswear brands within character casual zoning for the past 10 years and active brand launchings within contemporary zoning in the last 5 years. Also, as more brands are targeting men in their 20's as their main customers, it suggests that menswear brands are striving for a younger mindset. In terms of pricing, prestige and budget line launchings they seem to be dwindling, while bridge brands are increasing. This shows that customers are demanding luxury items at a reasonable price. Since there are higher ratio of foreign brands in dress shirts and contemporary zoning, domestic brands need to develop and produce more high quality clothes within these zonings.

3단 스피드 선풍기 모터의 정상 및 고정 운전에 대한 전압, 전류 및 온도 신호 분석 (Analysis on the Voltage, Current and Temperature Signals for Free and Locked Operation of Three Speed Electric Fan)

  • 김윤복;김두현
    • 한국화재소방학회논문지
    • /
    • 제28권3호
    • /
    • pp.87-91
    • /
    • 2014
  • 본 논문은 선풍기 모터의 회전을 정상 및 고정상태로 구분하여 주권선에서의 전압 및 전류, 모터 전체의 온도특성을 분석하여 전기화재 위험성을 제시하는 것을 목표로 하고 있다. 전압과 전류 신호에 대하여, 전압의 경우 정상상태와 고정상태에 대하여 큰 차이점은 없었으며, 전류의 경우는 비정상상태(최대 203 mA)보다 정상상태(최대 309 mA)가 상당히 높았다. 온도신호의 경우, 모터 전반에 있어서 온도 분포도가 다르게 나타났으며, 정상상태의 경우는 $4^{\circ}C$, 고정상태는 $18^{\circ}C$ 차를 보였다. 특히 대부분의 선풍기의 전기배선이 모터의 고정자철심에 부착되어 있었으며 해당전선의 허용온도가 $60^{\circ}C$를 감안했을 때에 절연열화가 가속될 수 있다. 또한 본 데이터는 선풍기 안전장치개발의 기초자료나 전기화재에 대한 조사 자료로 활용할 수 있다.

VCTF와 IV전선의 반단선에 의한 화재위험성 평가를 위한 열적특성 해석 (Analysis of Thermal Characteristics for the Fire Risk Assessment According to Partial Disconnection on the VCTF and IV Electric Wire)

  • 김두현;김성철;이종호;박종영;박영호;이형준
    • 한국안전학회지
    • /
    • 제23권4호
    • /
    • pp.47-52
    • /
    • 2008
  • Many researches on fire risk for normal electric wiring have been pursued in advanced countries such as the USA and Japan, but comparative studies of the partial disconnection and normal state of electric wires have not been conducted. Detection system for the cause of partial disconnection is not developed and prevention countermeasure for electrical fire by the cause is not effective. Therefore, in this paper, partial disconnection characteristics on electric wires were derived and analyzed by experiment and electrical-thermal finite element method(Flux 3D) on the model wires which consist of VCTF(PVC insulated PVC sheathed Cap Tyre Flexible Cord, KS C 3304) and IV(lndoorwire PVC, KS C 3302). VCTF is used in wiring portable electric appliances and the IV is used indoors. Interrelationships between partial disconnection premonitory symptom and current were derived and analyzed by the characteristics based on experiments and thermal analysis for electric wire according to current under normal state and 200% overload state of rated current.

6.6kV-200A급 초전도 한류기 DC Reactor용 전류도입선의 비정상상태 해석 (Unsteady-state analysis of current lead for DC Reactor of 6.6kV-200A superconductor current limiter)

  • 김형진;권기범;정은수;장호명
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.182-185
    • /
    • 2003
  • Temperature distribution and cooling load in binary current lead are analized, occurring fault current at DC Reactor type superconductor fault current limiter. It is assumed that Normal operating current is 300 A and fault current is 3000 A. Unsteady-state temperature distribution and cooling load of brass current lead optimized for 300 A and 1000 A are calculated by numerical method with TDMA. In the result of calculation, temperature increase in the brass current lead optimized for 300 A is higher than that in the brass current lead optimized for 1000 A, but the temperature increase in the brass current lead optimized for 300 A is not serious. Moreover, increase of cooling load in the brass current lead optimized for 300 A is higher than that in the brass current lead optimized for 1000 A, but normal cooling load in the brass current lead optimized for 300 A is lower than that in the brass current lead optimized for 1000 A. Therefore, designing current lead in superconductor fault current limiter had better to optimize for normal operating current.

  • PDF

N상 Interleaved Boost 컨버터의 정상상태 특성 해석 (Steady-State Analysis of N-phase Interleaved Boost Converter)

  • 박종규;장성동;신휘범;김흥근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권3호
    • /
    • pp.196-205
    • /
    • 2004
  • Although many papers about the interleaved boost converter(IBC) have been published, there are, unfortunately, no analytical and rigorous expressions for steady-state operation of the N-phase IBC. To understand the operating characteristics of the N-phase IBC, the averaged state equation and the general steady-state solutions are derived in this paper. The general expressions of the current unbalance due to the parameter mismatch, the inductor and input current ripples, and the output voltage ripple are also presented. Through the analytical expressions presented, the steady-state characteristics of the N-phase IBC are analyzed theoretically and verified experimentally.

초전도 배전 케이블 계통에서의 과도상태 해석 (Analysis of Transient State in the Superconducting distribution Cable Systems)

  • 김남열;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.555-557
    • /
    • 2003
  • As electric power transmission systems grow to supply the increasing electric power demand, transmission capacity is larger. but that's really difficult to secure the location for power transmission and distribution to user. The high temperature superconducting(HTS) cable is a method to solve this problem. But for applying to real systems, it needs to investigate the effect of HTS cable. The most important things is the investigation of fault condition. the fault on HTS cable include the quench state. When a fault occur in a circuit, three critical parameters(temperature, current density, magnetic field) exist. when one of these parameters exceeds the critical value, the superconducting becomes normal-conducting. f the cooling power is insufficient to recover the superconducting state, the normal-conducting zone expands. In order to solve these problem, this paper present simulate the quench state considering the over-current and over-voltage in the informal circuit and analyze the quench state.

  • PDF

삼상 변압기와 전력용 스위치를 이용한 초전도 한류기의 과도특성 해석 (Analysis of Transient Characteristics of SFCL using the Three-Phase Transformer and Power Switch)

  • 정병익;최효상;박정일;조금배
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1743-1747
    • /
    • 2012
  • The research of superconducting fault current limiter (SFCL) for reduction of the fault current is actively underway in the worldwide. In this paper, we analyzed the characteristics of a SFCL using the transformer and superconducting elements combined mutually in accordance with the fault types. The structure of this SFCL was composed of the secondary and third windings of a transformer connected to the load and the superconducting element, respectively. The provided electric power flew into the load connected to the secondary winding of the transformer in normal state. On the other hand, when the fault occurred in power system, the fault current was limited by closing the line of third winding of the transformer. At this time, the effect of the fault was minimized by opening the fault line in secondary winding of a transformer in power system. The sensing of the fault state was performed by the current transformer(CT) and then turn-on and turn-off switching behavior of the secondary line in the transformer was performed by the silicon-controlled rectifier(SCR). As a result, the proposed SFCL limited the fault current within one-cycle efficiently. Also, the degradation of the superconducting element in the normal state was avoided.

도전성 분말에 의한 아크전류의 파형 및 실효값 특성 (Characteristics on Arc Waveform and RMS of Current by Conductive Powder)

  • 김두현;강양현
    • 한국안전학회지
    • /
    • 제28권3호
    • /
    • pp.63-68
    • /
    • 2013
  • This paper is aimed to make an analysis on characteristics of the parallel arc waveform and RMS of current at the electrical tracking state by conductive powder. In order to achieve the goal in this paper, field state investigation at metal processing companies in Chung-Nam province area was conducted. With the field state investigation, conductive powder were collected from metal processing companies. By experiment on electrical connector(breaker, connector) over which the conductive powder were scattered, arc waveform and RMS of current were measured. The measured waveform and RMS(root-mean-square) of current were analyzed to describe characteristics and patterns of electrical arc by the conductive powder. It was proved that conductive powder on electrical connector can flow electrical current enough to make electrical fire with high thermal energy. Also the change of sine waveform and RMS of current can be used to find out relationship between electrical fire and fault signal by conductive powder. The results obtained in this paper will be very helpful for the prevention of electrical fires occurred at the metal processing companies.

Digital State Feedback Current Control using the Pole Placement Technique

  • Bae, Hyun-Su;Yang, Jeong-Hwan;Lee, Jae-Ho;Cho, Bo-Hyung
    • Journal of Power Electronics
    • /
    • 제7권3호
    • /
    • pp.213-221
    • /
    • 2007
  • A digital state feedback control method for the current mode control of DC-DC converters is proposed in this paper. This approach can precisely achieve interleaved current sharing among the converter modules. As the controller design and system analysis are performed in the time domain, the proposed method can easily satisfy the required converter specification by using the pole placement technique. The digital state feedback controller in the continuous and discrete time domain is derived for the robust tracking control. For the verification of the proposed control scheme, a parallel module bi-directional converter in a prototype 42V/14V hybrid automotive power system, which is a design example in the continuous time domain, and a parallel module buck converter, which is a design example in the discrete time domain, are implemented using a TMS320F2812 digital signal processor (DSP).