• Title/Summary/Keyword: Current Relation

Search Result 1,540, Processing Time 0.024 seconds

A Study on the Temporal Variation of Hydraulic Characteristics by the Stage-Discharge Relation Curve - at Jeokpogyo, Jindong of the Nakdong River - (수위-유량 관계곡선을 이용한 경년별 수리특성량 변동에 관한 연구 - 낙동강 적포교(赤浦橋) 및 진동(津洞) 지점을 중심으로 -)

  • Lee, Jae-Joon;Seol, Ji-Su;Kwak, Chang-Jae
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.10
    • /
    • pp.867-876
    • /
    • 2009
  • In this study, the stage-discharge relation curve made in 2006 is selected with standard curves to seize the hydraulic and geometric characteristics for the temporal variation of the river bed. The relationships among the standard stage-discharge relation curve and the existing stage-discharge relation curves, water level, cross sectional area, and flow velocity are analyzed. Jeokpogyo and Jindong which are the key station of Nakdong river are chosen for the study, with respect to the current river bed to convert the existing stage-discharge curves. The relationships for conversion of previous data, between water level and flow velocity are got. Also the relation equation between water level and cross sectional area and water level, flow velocity are derived. These conversion relationships shows good agreement between observed values and estimated values. It will be very useful to convert past hydraulic quantitations to current one.

Electromechanical Relationn of metallic heat wires and Its Application to the Estimation of In_situ Stress of Structural Tendons (금속계열선의 전기기계적 상관작용과 긴장력 계측이 가능한 긴장재)

  • Zi Goang-Seup;Jun Ki-Woo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.445-450
    • /
    • 2006
  • It is proposed that the electromechanical relation of the conductive materials with high electrical resistance may be used to estimate the current stress of prestressing tendons. To choose the best conductive material to this end, we studied the electromechanical relations of carbon fibers and metalic heat wires experimentally. It is found that the relation of carbon fibers can be modelled by a parabolic(or hyperbolic) function in the early stage of deformation. However because the relation is not consistent when it is unloaded and reload, carbon fibers are not suitable for this purpose. Metallic heat wires show a consistent linear relation during loading and unloading in the elastic deformation and are suitable for this purpose. To estimate the electromechanics relation of metallic wires, we developed a simple formula based on the rigid plasticity. We propose a new kind of prestressing tendons whose stress can be monitored.

  • PDF

Spatial Variation of the Polar Front in relation to the Tsushima Warm Current in the East Sea (동해에서 쓰시마난류의 변동과 관련한 극전선의 공간적 변화)

  • 이충일;조규대;최용규
    • Journal of Environmental Science International
    • /
    • v.12 no.9
    • /
    • pp.943-948
    • /
    • 2003
  • Variation of the polar front in the East Sea is studied using temperature and dissolved oxygen data obtained from Japan Meteorological Agency from 1972 to 1999. Variation of the polar front in the East Sea has a close relation to the variation of the Tsushima Warm Current (TWC). When the TWC spreads widely in the East Sea, polar front moves northward. The spatial variation of the polar front is greater in the southwestern area of the East Sea and the northern area of Tsugaru Strait where the variation of the TWC's distribution area is greater than those in others of the East Sea. Hence, in the southeastern area of the East Sea, that is, between near Noto peninsula and Tsugaru Strait, the spatial variation of the polar front is not so wide as in the southwestern area because the flow of TWC is stable.

Performance Improvement of Current-mode Device for Digital Audio Processor (디지털 오디오 프로세서용 전류모드 소자의 성능 개선에 관한 연구)

  • Kim, Seong-Kweon;Cho, Ju-Phil;Cha, Jae-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.5
    • /
    • pp.35-41
    • /
    • 2008
  • This paper presents the design method of current-mode signal processing for high speed and low power digital audio signal processing. The digital audio processor requires a digital signal processing such as fast Fourier transform (FFT), which has a problem of large power consumption according to the settled point number and high speed operation. Therefore, a current-mode signal processing with a switched Current (SI) circuit was employed to the digital audio signal processing because a limited battery life should be considered for a low power operation. However, current memory that construct a SI circuit has a problem called clock-feedthrough. In this paper, we examine the connection of dummy MOS that is the common solution of clock-feedthrough and are willing to calculate the relation of width between dummy MOS for a proposal of the design methodology for improvement of current memory. As a result of simulation, in case of that the width of memory MOS is 20um, ratio of input current and bias current is 0.3, the relation of width between switch MOS and dummy MOS is $W_{M4}=1.95W_{M3}+1.2$ for the width of switch MOS is 2~5um, it is $W_{M4}=0.92W_{M3}+6.3$ for the width of switch MOS is 5~10um. Then the defined relation of MOS transistors can be a useful design guidance for a high speed low power digital audio processor.

  • PDF

Changes of membrane resistance and membrane potentials by hyperpolarizing current stimulation in mouse unfertilized eggs (과분극 자극에 대한 mouse 미수정란의 세포막저항과 세포막전압의 변화)

  • Hong, Seong-geun;Kim, Ik-hyen;Cho, Young-deok
    • Korean Journal of Veterinary Research
    • /
    • v.31 no.1
    • /
    • pp.33-40
    • /
    • 1991
  • For the observations of both the membrane properties and the excitability on the unfertilized eggs of female mice, changes of the membrane resistance and the membrane potential by hyerpolarizing current stimulation were recorded. As current-voltage relation was linear over the entire range (-180mV~+60mV), membrane resistance($R_m$) was calculated from the amplitude of electrotonic potential to a given stimulus current. Also the presence of anode-break excitation was confirmed. The results were as follows; 1. There was a linear relation between the membrane resistance and resting membrane potential, the expected input resistance was 61. 4M$\Omega$(resting membrane potential was $-18.9{\pm}8.7mV$, mean${\pm}$SD, n=30). 2. Transient depolarization with overshoot was generated just after hyperpolarizing current stimulus and showed the dependency of stimulus duration. 3. Transient depolarization lasted over 30ms, amplitude of these depolarization was increased by high $Ca^{{+}{+}}$(20mM) and inhibited by $Ca^{{+}{+}}$-antagonist, $Mn^{{+}{+}}$. 4. From the above results, it was suggested that the unfertilized mouse egg showed the characteristics of the excitable cell.

  • PDF

Deuterium ion irradiation impact on the current-carrying capacity of DI-BSCCO superconducting tape

  • Rajput, M.;Swami, H.L.;Kumar, R.;Bano, A.;Vala, S.;Abhangi, M.;Prasad, Upendra;Kumar, Rajesh;Srinivasan, R.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2586-2591
    • /
    • 2022
  • In the present work, we have irradiated the DI-BSCCO superconducting tapes with the 100 keV deuterium ions to investigate the effect of ion irradiation on their critical current (Ic). The damage simulations are carried out using the binary collision approximation method to get the spatial distribution and depth profile of the damage events in the high temperature superconducting (HTS) tape. The point defects are formed near the surface of the HTS tape. These point defects change the vortex profile in the superconducting tape. Due to the long-range interaction of vortices with each other, the Ic of the tape degrades at the 77 K and self magnetic field. The radiation dose of 2.90 MGy degrades the 44% critical current of the tape. The results of the displacement per atom (dpa) and dose deposited by the deuterium ions are used to fit an empirical relation for predicting the degradation of the Ic of the tape. We include the dpa, dose and columnar defect terms produced by the incident particles in the empirical relation. The fitted empirical relation predicts that light ion irradiation degrades the Ic in the DI-BSCCO tape at the self field. This empirical relation can also be used in neutron irradiation to predict the lifetime of the DI-BSCCO tape. The change in the Ic of the DI-BSCCO tape due to deuterium irradiation is compared with the other second-generation HTS tape irradiated with energetic radiation.

The change of critical current with crack formation in a Bi-2223/Ag tape (크랙에 의한 Bi-2223/Ag 테이프의 임계전류 변화)

  • 박을주;설승윤
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.249-252
    • /
    • 2002
  • The change of critical current with a crack formation in a Bi-2223/Ag tape was studied by experimental and numerical analyses. Critical current of Bi-2223/Ag tape was measured with a continuous DC-power supply. The current-voltage relation of a Bi-2223/Ag tape is measured by the four point method. Numerical method is used to solve two dimensional heat conduction equation. By comparing the experimental and numerical results, the validity of numerical method is verified.

  • PDF

Development of the Program for levitation Force Analysis in a Superconducting Bulk (초전도 벌크의 부상력 해석 프로그램 개발)

  • 한승용;김우석;차귀수;한송엽
    • Progress in Superconductivity and Cryogenics
    • /
    • v.1 no.2
    • /
    • pp.20-24
    • /
    • 1999
  • The study of HTS(High Temperature Superconducting) bulk in magnetic levitation system requires the calculation of currents distribution in HTS bulk is very important to determine this forces. We have made computer program to find this current distribution and levitation force. J-E relation in HTS bulk is extremely nonlinear, so iteration method must be used to determine the current distribution. We developed the method to determine the current distribution in the unifrom-field model and, using this method, calculated the levitation force in permanent-magnet-levitation model.

  • PDF