• Title/Summary/Keyword: Current Reference Signal

Search Result 206, Processing Time 0.027 seconds

A Study on the Parallel Operation Control Technique of On-line UPS System (무정전전원장치의 병렬운전 제어기법에 관한 연구)

  • 곽철훈;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.585-592
    • /
    • 2003
  • The parallel operation system of UPS is used to increase reliability of power source at critical load. But parallel UPS system has a few defects, impedance is different from each other and circulating current occurs between UPSs, due to line impedance and parameter variation, though controlled by the same synchronization signal. According to such characteristic of parallel UPS, balanced load-sharing control is the most important technique in parallel UPS operation. In this paper, a novel power deviation compensation algorithm is proposed. it is composed of voltage controller to compensate power deviation that be calculated by using active and reactive current deviation between Inverters on synchronous d-q reference frame.

A Study on the Design of a Beta Ray Sensor for True Random Number Generators (진성난수 생성기를 위한 베타선 센서 설계에 관한 연구)

  • Kim, Young-Hee;Jin, HongZhou;Park, Kyunghwan;Kim, Jongbum;Ha, Pan-Bong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.6
    • /
    • pp.619-628
    • /
    • 2019
  • In this paper, we designed a beta ray sensor for a true random number generator. Instead of biasing the gate of the PMOS feedback transistor to a DC voltage, the current flowing through the PMOS feedback transistor is mirrored through a current bias circuit designed to be insensitive to PVT fluctuations, thereby minimizing fluctuations in the signal voltage of the CSA. In addition, by using the constant current supplied by the BGR (Bandgap Reference) circuit, the signal voltage is charged to the VCOM voltage level, thereby reducing the change in charge time to enable high-speed sensing. The beta ray sensor designed with 0.18㎛ CMOS process shows that the minimum signal voltage and maximum signal voltage of the CSA circuit which are resulted from corner simulation are 205mV and 303mV, respectively. and the minimum and maximum widths of the pulses generated by comparing the output signal through the pulse shaper with the threshold voltage (VTHR) voltage of the comparator, were 0.592㎲ and 1.247㎲, respectively. resulting in high-speed detection of 100kHz. Thus, it is designed to count up to 100 kilo pulses per second.

Current-Fed Reactive Power Compensator Using Delta Modulation Technique (델터 변조 방식을 이용한 전류형 무효전력 보상장치)

  • 백형래;김한성
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.3
    • /
    • pp.244-252
    • /
    • 1992
  • This paper describes a reactive power compensator using current-source delta modulation converter, which compensates the reactive power in the ac sides of 3-phase rectifier. In the conventional current control methods for the current-type reactive power compensators, it is usual to compare the reactive reference current signal with the triangular wave and hence to generate the ON-OFF signals for the reactive power compensator. To improve the response as well as the control capability, the delta modulated current control technique is used in this paper. As a result, the input power factor is improved close to unity and both simulation and experimental results show good compensating performances.

  • PDF

Modulated Carrier Control for Single-Phase Active Power Filter

  • Son, Gibong;Kim, Hyejin;Cho, Bo-Hyung
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.218-219
    • /
    • 2013
  • In this paper, an improved modulated carrier control for a single-phase shunt active power filter(SAPF), which eliminates harmonic currents at the ac main drawn by nonlinear loads, is introduced. In contrast to conventional methods, since this control method does not need to generate a current reference for SAPF, only the ac main current is sensed instead of the load current and SAPF current. With the proposed control method, the ac main current is directly controlled to be sinusoidal and in phase with the supplied ac voltage by simply comparing the modulated carrier signal with the ac main current. The operation of the proposed SAPF is analyzed and simulation results verify its performance.

  • PDF

Reference Model Updating of Considering Disturbance Characteristics for Fault Diagnosis of Large-scale DC Bus Capacitors (대용량 직류버스 커패시터의 고장진단을 위한 외란특성 반영의 레퍼런스 모델 개선)

  • Lee, Tae-Bong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.213-218
    • /
    • 2017
  • The DC electrolytic capacitor for DC-link of power converter is widely used in various power electronic circuits and system application. Its functions include, DC Bus voltage stabilization, conduction of ripple current due to switching events, voltage smoothing, etc. Unfortunately, DC electrolytic capacitors are some of the weakest components in power electronics converters. Many papers have proposed different algorithms or diagnosis method to determinate the ESR and tan ${\delta}$ capacitance C for fault alarm system of the electrolytic capacitor. However, both ESR vary with frequency and temperature. Accurate knowledge of both parameters at the capacitors operating conditions is essential to achieve the best reference data of fault alarm. According to parameter analysis, the capacitance increases with temperature and the initial ESR decreases. Higher frequencies make the reference ESR with the initial ESRo value to decrease. Analysis results show that the proposed DC Bus electrolytic capacitor reference ESR model setting technique can be applied to advanced reference signal of capacitor diagnosis systems successfully.

Dynamic Response Improvement of Stand Alone Engine-Generator System using Double Voltage Detection Method (전압 이중 검출법에 의한 독립형 엔진-발전기 시스템 응답특성 개선)

  • Lee, Dong-Hee;Ahn, Jin-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1195-1199
    • /
    • 2008
  • In this paper, peak detector of generator's output voltage and variable gain controller are introduced for a fast dynamic response. The conventional r,m.s, signal detected has inherent time delay, and the dynamic response of generator using conventional PID controller has some problem in sudden load change. In this paper, the peak detector and signal selector with variable gain controller is used to overcome this problem. The main controller can check the voltage state from the peak detector. When a sudden load change, the over-voltage and under-voltage signal from peak detector change the controller's gain and exciter's current reference. The proposed scheme can improve the dynamic response, which is verified from experimental test of 200kW diesel engine-generator.

Low-Noise MEMS Microphone Readout Integrated Circuit Using Positive Feedback Signal Amplification

  • Kim, Yi-Gyeong;Cho, Min-Hyung;Lee, Jaewoo;Jeon, Young-Deuk;Roh, Tae Moon;Lyuh, Chun-Gi;Yang, Woo Seok;Kwon, Jong-Kee
    • ETRI Journal
    • /
    • v.38 no.2
    • /
    • pp.235-243
    • /
    • 2016
  • A low-noise readout integrated circuit (ROIC) for a microelectromechanical systems (MEMS) microphone is presented in this paper. A positive feedback signal amplification technique is applied at the front-end of the ROIC to minimize the effect of the output buffer noise. A feedback scheme in the source follower prevents degradation of the noise performance caused by both the noise of the input reference current and the noise of the power supply. A voltage booster adopts noise filters to cut out the noise of the sensor bias voltage. The prototype ROIC achieves an input referred noise (A-weighted) of -114.2 dBV over an audio bandwidth of 20 Hz to 20 kHz with a $136{\mu}A$ current consumption. The chip is occupied with an active area of $0.35mm^2$ and a chip area of $0.54mm^2$.

Design of a 10 bit Low-power current-mode CMOS A/D converter with Current predictors (전류예측기를 이용한 10비트 저전력 전류구동 CMOS A/D 변환기 설계)

  • 심성훈;권용복;윤광섭
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.10
    • /
    • pp.22-29
    • /
    • 1998
  • In this paper, an 10 bit current-mode CMOS A/D converter with a current predictor is designed with a CMOS process to be integrated into a portable image signal processing system. A current predictor let the number of comparator reduce to 70 percent compared with the two step flash architecture. The current magnitude of current reference is reduced to 68 percent with a modular current reference. The designed 10 bit Low-power current-mode CMOS A/D converter with a current predictor is simulated with HSPICE using 0.6$\mu\textrm{m}$ N-well single-poly triple-metal CMOS process parameters. It results in a conversion rate of 10MSamples/s. A power consumption is measured to be 94.4mW at single +5V supply voltage. The 10 bit A/D converter fabricated using the same process occupies the chip area of 1.8mm x 2.4mm.

  • PDF

Modelling and Performance Analysis of UPQC with Digital Kalman Control Algorithm under Unbalanced Distorted Source Voltage conditions

  • Kumar, Venkateshv;Ramachandran, Rajeswari
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1830-1843
    • /
    • 2018
  • In this paper, the generation of a reference current and voltage signal based on a Kalman filter is offered for a 3-phase 4wire UPQC (Unified Power Quality Conditioner). The performance of the UPQC is improved with source voltages that are distorted due to harmonic components. Despite harmonic and frequency variations, the Kalman filter is capable enough to determine the amplitude and the phase angle of load currents and source voltages. The calculation of the first state is sufficient to identify the fundamental components of the current, voltage and angle. Therefore, the Kalman state estimator is fast and simple. A Kalman based control strategy is proposed and implemented for a UPQC in a distribution system. The performance of the proposed control strategy is assessed for all possible source conditions with varying nonlinear and linear loads. The functioning of the proposed control algorithm with a UPQC is scrutinized and validated through simulations employing MATLAB/Simulink software. Using a FPGA SPATRAN 3A DSP board, the proposed algorithm is developed and implemented. A small-scale laboratory prototype is built to verify the simulation results. The stated control scheme for the UPQC reduces the following issues, voltage sags, voltage swells, harmonic distortions (voltage and current), unbalanced supply voltage and unbalanced power factor under dynamic and steady-state operating conditions.

Monitoring of Machining State in Turning by Means of Information and Feed Motor Current (NC 정보와 이송축 모터 전류를 이용한 선삭 가공 상태 감시)

  • 안중환;김화영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.156-161
    • /
    • 1992
  • In this research a monitoring system for turning using NC information and the current of feed motor as a monitoring signal was developed. The overall system consists of modules such as learning process, NC data transmission, generation of forecast information, signal acquisition, monitoring and post process. In the learning process, the reference data and the cutting force equation necessary for monitoring are obtained from the accumulated monitoring results. In the generation of forecast information, the information of forecasted cutting forces is acquired from the cutting force equation and NC program and appended to each NC block as a monitor code. Reliability of monitoring is improved by using the monitor code in the real-time monitoring. Monitoring module is divided into two parts : the off-line monitoring where errors of NC program are checked and the on-line monitoring where the level of motor current is monitored during cutting operations. If the actual current level exceeds the limit value provided by the monitor code in the level monitoring, it is recognized as abnormal. In the event of abnormal status, the post processor sends the emergency stop signal to NC controller to stop the operation. Actual experiments have shown that the developed monitoring system works well.