• 제목/요약/키워드: Current Phasor

검색결과 61건 처리시간 0.023초

고장 왜란 기록기를 위한 주파수 추정 기법의 비교 연구 (Comparative Studies of Frequency Estimation Method for Fault Disturbance Recorder)

  • 박철원
    • 전기학회논문지P
    • /
    • 제61권2호
    • /
    • pp.87-92
    • /
    • 2012
  • Voltage and current phasor estimation has been executed by GPS-based synchronized PMU, which has become an important way of wide-area blackout protection for the prevention of expending faults in a power system. The PMU technique can not easily get the field data and it is impossible to share information, so that there has been used a FNET(Frequency Monitoring Network) method for the wide-area intelligent protection in USA. It consists of FDR(Fault Disturbance Recorder) and IMS(Information Management System). Therefore, FDR must provide an optimal frequency estimation method that is robust to noise and failure. In this paper, we present comparative studies for the frequency estimation method using IRDWT(Improved Recursive Discrete Wavelet Transform), FRDWT(Fast Recursive Discrete Wavelet Transform), and DFT(Discrete Fourier Transform). The Republic of Korea345[kV] power system modeling data by EMTP-RV are used to evaluate the performance of the proposed two kinds of RDWT(Recursive Discrete Wavelet Transform) and DFT. The simulation results show that the proposed frequency estimation technique using FRDWT could be the optimal frequency measurement method, and thus be applied to FDR.

에너지보존법칙을 이용한 전력계통 안정도 직접 해석법에서의 응용 (Direct Energy Method of Power System Stability Analysis and its Application by using Energy Conservation Law)

  • 이용훈;조병훈;류헌수;문영현
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권10호
    • /
    • pp.1207-1214
    • /
    • 1999
  • Many papers have recently been presented to develop energy functions for power systems. However, earlier studies adopted case-by-case approaches, which failed to give a general approach to deal with various kinds of generator models. In this paper, two useful theorems are developed regarding the integral relationships of the generator power versus its phasor current and voltage. By using the proposed theorems, an exact energy conservation law can be derived from the complex integral. The proposed energy conservation law, which is free of the generator model, can be utilized to develop energy functions for various kinds of generator models including the speed governors and exciters. An illustrative example is given for a multimachine system with the Eq' model of generator. This thesis also shows a possibility of more accurate and fast stability analysis by using the proposed Energy Conservation Law.

  • PDF

토오크 맥동량에 의한 전압원 PAWM 인버터의 평가 (An Evaluation of Voltage Source PAWM Inverter by Torque Ripple Content)

  • 이치환;구본호;권우현
    • 대한전자공학회논문지
    • /
    • 제26권5호
    • /
    • pp.60-70
    • /
    • 1989
  • 본 연구는 인버터로 구동되는 유도전동기에서 발생되는 토오크 맥동을 표현하는, 고조파 토오크 함수 HTF(harmonic torque function)를 제안하고, 컴퓨터 시뮬레이션과 실험을 통하여 HTF의 타당성을 입증하였다. 제안된 HTF는 고조파 전류의 크기 뿐만 아니라 위상까지 고려하므로서 부하변동에 무관한 고조파 토오크 함수가 되었으며, 이를 six-step. SPWM 및 TPWM의 펄스 폭 제어 인버터에 적용하여 비교하였다. 그 결과 PAWM 인버터에서의 우수한 제어방법이 선택되었다. 한 주기당 펄스수가 9이하에서는 six-step이, 출력전압 크기와 토오크 맥동의 측면에서, SPWM 및 TPWM보다 우수함을 알 수 있었다.

  • PDF

고효율 벡터제어 유도전동식 구동 시트템에 관한 연구 (A Study on High Efficiency Vector Controlled Induction Motor Drive System)

  • Kim, Heung-Geun
    • 대한전기학회논문지
    • /
    • 제39권11호
    • /
    • pp.1174-1182
    • /
    • 1990
  • A hgih efficiency and good dynamic performance drive system of an induction motor is presented in this paper using vector control technique. If the induction motor is driven under light loads with rated flux, the iron loss is excessively large compared with the copper loss, resulting in poor motor efficiency. High efficiency drive of an induction motor can be achieved by adjusting the flux level which leads the total motor loss to be a minimum value. Generally reducing the flux degrades the dynamic performance, but the dynamic performance of the proposed system is also maintained high. If the d-axis is coincident with rotor flux phasor in synchronous rotating reference frame, the stator current can be decoupled as flux component and torque component. At steady state, the developed motor torque is proportional to the product of the flux and torque component. The combination of the two components minimizing the motor loss could be found with numerical method. As the procedure to obtain the optimal combination is too hard, it is found experimentally. The system block diagram is suggested for maximum efficiency control. The proposed system is studied through digital simulation and verified with experiment. The experimental results show the possiblity of a high efficiency drive with good dynamic performance of maximum efficiency control.

  • PDF

전력계통의 고장해석을 위한 대화식 교육용 소프트웨어 개발 (Development of an Interactive Educational Software for Fault Analysis in Power Systems)

  • 조기선;양광민;박우진;조영훈;박종배;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.293-295
    • /
    • 2001
  • This paper describes an interactive educational software developed at Konkuk University. This software provides an educational opportunity for electrical engineering students at the junior level to expand their knowledge about fault analysis in power systems. The developed educational software has three main modules: 1) Z-building, 2) setting the type and location of the fault, 3) displaying the calculated fault currents, according to the given simulation options. The main features of this tool are the diversification of acquisition network data, the function of learning about the z-building procedures, and the dynamic display function of state vectors-all voltage/current phasor. To verity the effectiveness of the developed educational software, some case studies are performed.

  • PDF

공진형 인버터를 위한 범용 퍼지 논리 제어기 설계 (General Digital Fuzzy Logic Controller Design For Resonant Inverter)

  • 김태언;김남수;임영도
    • 융합신호처리학회논문지
    • /
    • 제5권1호
    • /
    • pp.60-65
    • /
    • 2004
  • 고주파 유도 가열 시스템에서 철과 같은 물체를 가열하게 되면, 가열된 금속이 큐리점 부근에서 전기적인 임피던스가 급격하게 변화하는 특징을 가지는 시변 시스템이 된다. 또한 부하 임피던스가 변화함에 따라 시스템의 부하 공진 주파수가 달라지므로 해서 시스템의 효율이 감소하는 문제점이 있었다. 그리고, 피가열 물체의 용융이나 삽입 상태에 따른 시스템의 단락 현상으로 인해 시스템이 파괴되는 문제점이 있었다. 본 논문에서는 이런 문제점을 해결하기 위한 방법으로 PLL에 의한 부하 공진 주파수를 추종하면서 스위칭 손실을 줄이고, 시변 부하에 대한 유도 가열시 큐리점 부근의 급격한 부하 임피던스 변화에도 안정된 정전력 제어가 가능할 뿐 아니라 대전력용에 적합하고, 단락현상으로부터 시스템을 보호하는 병렬 공진형 인버터 시스템에 적용되는 퍼지논리 제어기를 설계하였다.

  • PDF

에너지 보존법칙과 전력계통 안정도 직접 해석법에서의 응용 (Energy Conservation Law and its application for Direct Energy method of Power System Stability)

  • 문영훈;이용훈;조병훈;류헌수;최병곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.263-268
    • /
    • 1998
  • Many papers have recently been presented to develop energy functions for power systems. However, earlier studies adopted case-by-case approaches, which failed to give a general approach to deal with various kinds of generator models. In this paper, two useful theorems are developed regarding the integral relationships of the generator power versus its phasor current and voltage. By using the proposed theorems, an exact energy conservation law can be derived from the complex integral. The proposed energy conservation law, which is free of the generator model, can be utilized to develop energy functions for various kinds of generator models including the speed governors, and exciters. An illustrative example is given for a multimachine system with the Eq' model of generator. This thesis also shows a possibility of more accurate and fast stability analysis by using the proposed Energy Conservation Law.

  • PDF

Design and Evaluation of PMU Performance Measurement and GPS Monitoring System for Power Grid Stabilization

  • Yang, Sung-Hoon;Lee, Chang Bok;Lee, Young Kyu;Lee, Jong Koo
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제4권2호
    • /
    • pp.67-72
    • /
    • 2015
  • Power grid techniques are distributed over general power systems ranging from power stations to power transmission, power distribution, and users. To monitor and control the elements and performance of a power system in real time in the extensive area of power generation, power transmission, wide-area monitoring (WAM) and control techniques are required (Sattinger et al. 2007). Also, to efficiently operate a power grid, integrated techniques of information and communication technology are required for the application of communication network and relevant equipment, computing, and system control software. WAM should make a precise power grid measurement of more than once per cycle by time synchronization using GPS. By collecting the measurement values of a power grid from substations located at faraway regions through remote communication, the current status of the entire power grid system can be examined. However, for GPS that is used in general national industries, unexpected dangerous situations have occurred due to its deterioration and jamming. Currently, the power grid is based on a synchronization system using GPS. Thus, interruption of the time synchronization system of the power system due to the failure or abnormal condition of GPS would have enormous effects on each field such as economy, security, and the lives of the public due to the destruction of the synchronization system of the national power grid. Developed countries have an emergency substitute system in preparation for this abnormal situation of GPS. Therefore, in Korea, a system that is used to prepare for the interruption of GPS reception should also be established on a long-term basis; but prior to this, it is required that an evaluation technique for the time synchronization performance of a GPS receiver using an atomic clock within the power grid. In this study, a monitoring system of time synchronization based on GPS at a power grid was implemented, and the results were presented.

FDR를 위한 RDWT에 의한 주파수 추정 기법 (Frequency Estimation Method using Recursive Discrete Wavelet Transform for Fault Disturbance Recorder)

  • 박철원;반우현
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1492-1501
    • /
    • 2011
  • A wide-area protection intelligent technique has been used to improve a reliability in power systems and to prevent a blackout. Nowadays, voltage and current phasor estimation has been executed by GPS-based synchronized PMU, which has become an important way of wide-area blackout protection for the prevention of expending faults in power systems. As this technique has the difficulties in collecting and sharing of information, there have been used a FNET method for the wide-area intelligent protection. This technique is very useful for the prediction of the inception fault and for the prevention of fault propagation with accurate monitoring frequency and frequency deviation. It consists of FDRs and IMS. It is well known that FNET can detect the dynamic behavior of system and obtain the real-time frequency information. Therefore, FDRs must adopt a optimal frequency estimation method that is robust to noise and fault. In this paper, we present comparative studies for the frequency estimation method using IRDWT(improved recursive discrete wavelet transform), for the frequency estimation method using FRDWT(fast recursive discrete wavelet transform). we used the Republic of Korea 345kV power system modeling data by EMTP-RV. The user-defined arbitrary waveforms were used in order to evaluate the performance of the proposed two kinds of RDWT. Also, the frequency variation data in various range, both large range and small range, were used for simulation. The simulation results showed that the proposed frequency estimation technique using FRDWT can be the optimal frequency measurement method applied to FDRs.

Improvement of transmission-line-based fault locating for typical traveling-wave accelerator with constant-gradient structures

  • T.N. Hu;Y.F. Zeng;K. Peng;H. Hu;H.M. Wang;K.F. Liu
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2011-2018
    • /
    • 2024
  • Since RF breakdown is one of the primary limitations to improving the performances of RF accelerators, extensive efforts have been dedicated to locating the breakdowns. However, most existing methods rely on specialized techniques, resulting in high financial burdens. Although the method based on transient response of transmission line (TL) is suitable for facilities with sporadic recoverable breakdowns, practical operations are susceptible to notable errors. This study revisits the fundamental theories of lossless TL and investigates the wave process to understand the characteristics of the reversed pulse induced by the breakdowns. By utilizing steadystate response of the TL and employing phasor method, we derive analytical formulas to determine the exact location of breakdowns within the faulty cell for constant-gradient TW accelerator. Furthermore, the derived formulas demonstrate their independence from RF phase, thereby distinguishing them from traditional phasebased methods. Additionally, experimental validations are conducted at the HUST injector, and the results confirm the consistency of the analysis. Thus, the proposed method represents a promising improvement over the TL-based approaches and serves as a valuable complement to current techniques. Importantly, this method demonstrates particular advantages for constructed TW accelerators seeking to achieve a balance among high performance, low costs, and compact layouts.