• Title/Summary/Keyword: Current Fed Inverter

Search Result 210, Processing Time 0.032 seconds

Enhanced Voltage Gain Single-Phase Current-Fed qZ-Source Inverter (전압 이득이 향상된 단상 전류형 qZ-소스 인버터)

  • Shin, Hyun-Hak;Cha, Hon-Nyong;Kim, Heung-Geun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.305-311
    • /
    • 2013
  • This paper proposes a performance improvement of existing single-phase current-fed qZ-Source inverter. Voltage gain of the traditional voltage-fed full-bridge inverter and single-phase current-fed qZ-source inverter is only equal to or smaller than input voltage. The proposed inverter can obtain twice higher voltage gain than the single-phase current-fed qZ-Source inverter by adding an extra switch and a capacitor in the circuit. In addition, the proposed inverter shares the common ground between dc input and ac output voltage. Therefore, the proposed inverter can eliminate the possible ground leakage current problem when it is used for grid-tied photovoltaic inverter system. A 120 W prototype inverter is built and tested to verify performances of the proposed inverter.

SINGLE-PHASE CURRENT SOURCE INVERTER WITH PULSE AREA MODULATION SCHEME FOR SOLAR POWER CONDITIONER

  • Hirachi, K.;Matsumoto, K.;Ishitobi, M.;Ishibashi, M.;Nakaoka, M.
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.724-729
    • /
    • 1998
  • In general, a single-phase current-fed PWM inverter using IGBTs has some unique advantages for small scale distributed utility-interactive power supply system as compared with voltage-fed PWM inverter. In particular, this is more suitable and acceptable for a non-isolated type utility-interactive power conditioner, which is going to be widely used for residential solar photovoltaic (PV) power generation system in Japan. However, this current-fed PWM inverter has a significant disadvantage. The output current of this inverter includes large harmonic contents when the inductance of smoothing reactor in its DC side is not large enough to eliminate its current ripple components of this inverter. In order to overcome this problem, a new conceptual pulse area modulation scheme for this inverter is introduced in difference with conventional PWM strategy. This paper presents a new effective control implementation of this PV power conditioner which is able to reduce the harmonic component in the output current produced by the single-phase current-fed PWM inverter even when the ripple current in the smoothing DC reactor is relatively large. The operating principle of the proposed control strategy introdued for this inverter system is described, and its simulation results are evaluated and discussed herein.

  • PDF

HE Link Current-Fed Inverter for Fuel Cell Applications (연료전지 응용을 위한 HF Link 전류원 인버터)

  • Chung Se-Kyo;Shin Hwi-Beom;Lee Hyun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.17-20
    • /
    • 2003
  • This paper presents a high frequency (HF) link current-fed inverter fur fuel cell applications. The circuit topology, operation and control method of the proposed HF link current-fed inverter are presented. The active cancellation technique of the 120Hz input harmonic current is also considered. The simulation results are provided to show the feasibility of the proposed inverter scheme.

  • PDF

A Study on Characteristic Analysis of AC to AC Current-Fed Type High Frequency Resonant Inverter with High Power Factor (고역율 AC/AC 전류형 고주파 공진 인버터의 특성해석에 관한 연구)

  • Kim, Jong-Hae;Won, Jae-Sun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.1
    • /
    • pp.16-28
    • /
    • 2014
  • This paper presents a novel high-power-factor circuit topology of AC to AC current-fed type high frequency resonant inverter which includes the function of power factor correction(PFC) in the proposed inverter to operate the AC input block with high power factor. The proposed circuit topology of AC to AC current fed type high resonant inverter removes DC link electrolytic capacitor and has also the one of power factor correction(PFC) in the inverter circuit without an additional PFC circuit since the input current by constituting it in parallel as an unit inverter, which assumes the class-E high frequency resonant inverter of conventional current-fed type, flows in the form of the resultant current flowing through each constant current reactor($L_{d1}$, $L_{d2}$). The circuit analysis of proposed inverter is generally described by adopting the normalized parameters and the evaluation of its operating characteristics are conducted by using the parameters such as the ratio of switching and resonant frequency(${\mu}$), coupling coefficient(k) and so on. An example of procedure for circuit design based on the characteristic values obtained from the theoretical analysis is presented. To confirm the validity of the theoretical analysis, the experimental results are also presented. In the future, the proposed inverter shows it can be practically used as power supply system for induction heating application, DC-DC converter etc.

New Current-fed GTO Inverter and Its Basic Characteristics (전류형 GTO Inverter와 그 기본특성)

  • ;Kouki MATSUE
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.1
    • /
    • pp.3-8
    • /
    • 1987
  • The conventional autosequentially commutated current-fed inverter (ASCI) is widely employed with the induction motor drives for speed control. Howener, this inverter has a limit of high power and high frequency indution motor drives. One of the limitations is to be found in the commutation capacitors in the main circuit of this inverter. A new current-fed gate turn-off thyristor (GTO) inverter is developed. This inverter is composed of the main GTO bridge configuration and the improved energy rebound circuit (ERC)without the commutation capacitor. This inverter works stable at high frequency from light load to heavy one. The improved ERC is used not only to rebound the load reactive power to the dc link, but also to return the power in the load to the ac source. The new GTO inverter circuit and the characteristics of the inverter induction motor drives are explained and analyzed.

  • PDF

A Study on Characteristic Analysis of Current Fed High Frequency Resonant Inverter for Wax-Sealing (Wax-Sealing용 전류형 고주파 공진 인버터의 특성해석에 관한 연구)

  • Kim, Dong-Hui;Won, Jae-Seon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.11
    • /
    • pp.568-574
    • /
    • 2001
  • This paper describes a current fed high frequency resonant inverter can be used as the power supply for wax-sealing. This circuit configuration is composed of conventional two unit inverter of single ended current find type in parallel. The proposed inverter can realize ZVS operation by using resonant capacitor to ZVS capacitor and has merits not only reduction of switch current distribution but also extension of load range in comparison with the conventional single-ended current fed high frequency resonant inverter. This analysis of proposed circuit uses normalized parameter and characteristic estimation which is needed in each step before design is generally described according to normalized frequency($\mu$), normalized resistance(λ) and parameters. On the basis of characteristic values, a method of the circuit design is presented. Also, the theoretical analysis is proved through experiment and this proposed circuit shows that it can be practically used as the power supply system for wax-sealing and DC-DC converter.

  • PDF

A Study on Performance of Curent Regulations for IGBT Inverter-Fed Induction Motor Drive Systems (IGBT 인버터-유도전동기 구동시스템을 위한 전류제어기의 특성 연구)

  • 이동춘;김영렬;설승기
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.2
    • /
    • pp.215-225
    • /
    • 1994
  • In this paper, a performance evaluation of different current regulators for induction motor drive systems fed by IGBT inverter is presented. The twoparts of current regulation are considered : current error compensation part, voltage modulation part. The characteristics of hysteresis, synchronous PI, decoupled PI, predictive, deadbeat and stage feedback controllers are analyzed and the steady-state performances and transient responses of current regulation are well compared through the simulation and experimental results.

  • PDF

Automatic frequency Control Current-Source Inverter for Forging Application

  • Chudjuarjeen, Saichol;Koompai, Chayant;Monyakul, Veerapol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.238-242
    • /
    • 2004
  • The paper describes an automatic frequency control current-fed inverter for forging applications. The IGBT in series with diodes as its switching devices in the inverter circuit which is of full-bridge type. The operating frequency is automatically tracked to maintain a small constant leading phase angle when load parameters change. The load voltage is controlled to protect the switches. The output power can be adjusted by varying the input current from phase controlled rectifiers which is a part of current source. The system has been operated at 15-17 kHz. The output power transferred to the load is 1,595 watts. It can heat the steel work pieces with 15 mm diameter and 120 mm long from room temperature to approximately 1100 $^{\circ}C$ within 20 seconds with 0.97 leading power factor on the input side.

  • PDF

Simple On-line Elimination Strategy of Dead Time and Nonlinearity in Inverter-fed IPMSM Drive Using Current Slope Information (IPMSM 드라이브에서 전류 기울기 정보를 이용한 데드타임 및 인버터 비선형성 효과의 간단한 제거 기법)

  • Park, Dong-Min;Kim, Myung-Bok;Kim, Kyeong-Hwa
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.401-408
    • /
    • 2012
  • A simple on-line elimination strategy of the dead time and inverter nonlinearity using the current slope information is presented for a PWM inverter-fed IPMSM (Interior Permanent Magnet Synchronous Motor) drive. In a PWM inverter-fed IPMSM drive, a dead time is inserted to prevent a breakdown of switching device. This distorts the inverter output voltage, resulting in a current distortion and torque ripple. In addition to the dead time, inverter nonlinearity exists in switching devices of the PWM inverter, which is generally dependent on operating conditions such as the temperature, DC link voltage, and current. The proposed scheme is based on the fact that the d-axis current ripple is mainly caused by the dead time and inverter nonlinearity. To eliminate such an influence, the current slope information is determined. The obtained current slope information is processed by the PI controller to estimate the disturbance caused by the dead time and inverter nonlinearity. The overall system is implemented using DSP TMS320F28335 and the validity of the proposed algorithm is verified through the simulation and experiments. Without requiring any additional hardware, the proposed scheme can effectively eliminate the dead time and inverter nonlinearity even in the presence of the parameter uncertainty.

Novel Electromagnetic Induction Eddy Current DPH based Continuous Pipeline Fluid Heating using Soft Switching PWM High Frequency Inverter

  • Nam, Jing-Rak
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.3
    • /
    • pp.305-309
    • /
    • 2008
  • This paper presents an innovative prototype of a new conceptual electromagnetic induction eddy current based fluid heating appliance using voltage-fed quasi resonant zero voltage soft switching PWM high-frequency inverter using IGBTs, which can operate at a constant frequency variable power regulation scheme. The promising simple high efficient low noise inverter type electromagnetic induction eddy current based pipeline fluid heating appliance is proposed for saturated steam generator, superheated steam generator, hot water and hot air producer, metal catalyst heating for exhaust gas cleaning in engine. Under these technological backgrounds, a novel electromagnetic induction eddy current Dual Packs Heater(DPH) based pipeline fluid heating incorporates thin metal layer type package for continuous fluid heating appliances applying two types of voltage-fed quasi load resonant ZVS-PWM high frequency inverter. The unique features of a novel electromagnetic induction eddy current DPH based continuous pipeline fluid heating appliance is illustrated on the basis of simulation and discussed for the steady state operating characteristics and experimental results.