Field Measurement and Analysis of Voltage Unbalance Factor (전압불평형율의 현장측정 및 분석)

  • Jeong, Jong-Ho;Park, Young-Jeen;Lee, Eun-Woong;Kim, Jong-Gyeum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.1
    • /
    • pp.41-46
    • /
    • 2005
  • Most of LV customer have applied the 3-phase four wire system distribution system because it has advantage of supplying both of 1-phase & 3-phase loads simultaneously. Due to its structural simplicity, it is more convenient for use rather than the conventional separated scheme. But voltage unbalance more commonly emerges in individual customer loads due to phase load unbalance, especially where, single-phase power loads are used. Voltage unbalance factor(VUF) represents the loss of symmetry in the supply(magnitude and angle). It leads some problems such as de-rating or power losses. In this paper, voltage and current waveform in the actual fields have been measured and analyzed in relation with internationally allowable voltage unbalance limits.

A Study on Improving of Fault Recognition Method in Distribution Line (배전선로 고장인지 방식에 관한 연구)

  • Lee, Jin;Park, Chan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.1
    • /
    • pp.65-69
    • /
    • 2020
  • The aim of this study is to improve the fault decision ability of FRTU (Feeder remote terminal unit) in DAS (Distribution automation system). FRTU uses the FI (Fault indicator) algorithm based on fault current pickup and operation of the protection device. Even if the inrush current flows or the protection device is sensitive to the transient current, FRTU may indicate incorrect fault information. To address these problems, we propose an improved fault recognition algorithm that can be applied to FRTU. We will detect a specific wave that is indicative of a fault, and use this information to identify a fault wave. The specific wave-detection algorithm is based on the duration and periodicity of the voltage, current, and harmonic variations. In addition, we propose fault recognition algorithms using voltage factor variation analysis and DWT (Discrete wavelet transform). All the wave data used in this study were actual data stored in FRTU.

A Study on the Compensation Control of Distribution Static Compensator Considering Induction Motor Load Using PSCAD/EMTDC (PACAD/EMTDC을 이용한 유도기 부하를 고려한 DSTATCOM의 보상제어에 관한 연구)

  • Lee, Myung-Un;Cho, Myung-Hyun
    • 전자공학회논문지 IE
    • /
    • v.43 no.1
    • /
    • pp.32-38
    • /
    • 2006
  • When induction motor moves, power quality decline of line is risen seriously because provoking voltage drop the moment to system power supply by excessive moving current as well as power-factor drop in case drive by light-load because current reaches in 6 times $\sim$ 8 times of rated current. In this paper, a modeling did an distribution system 13 bus type model and induction machine load presents in IEEE using a PSCAD/EMTDE package, and it displayed an accident conspiracy and a compensating factor of DSTATCOM through simulation show.

Research on the Effect of Interconnected Distributed Wind Power Generation(225[kV], AC Link Method) on Power Quality in System (연계형 풍력발전설비(225[kV], AC 링크방식)가 전력계통의 전원 품질에 미치는 영향에 관한 연구 분석)

  • Na, Chae-Dong;Park, Jung-Shin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.147-153
    • /
    • 2010
  • When small scale wind and solar power generation systems are connected to conventional power distribution system. It is worried that it can affect the quality of electricity such as voltage variation, power factor, frequency, harmonics and flicker. Therefore, in this research, in order to investigate the effects of wind power generation equipments(AC link method) on electrical power quality, when they are connected to distribution system. Power quality analyzer was installed respectively at the front side of power conversion system of conventional wind generation system and secondary side of consumer's power supply at distribution line. Measurements on power quality were performed and the effects of the wind generation system on distribution system were analyzed when it was and was not operated. The results show that 0.34[%] increase on voltage variation, 0.145 increase on current crest factor and 0.6[$^{\circ}$] deviation on phase difference when the power generation system was operated.

A Study on the Standardization of Smart Distribution Board for Electrical Safety (전기안전을 위한 스마트분전반 표준화 연구)

  • Moon, Hyun-Wook;Lim, Young-Bea;Kim, Dong-Woo;Lee, Sang-Ick;Choi, Myeong-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.227-231
    • /
    • 2016
  • Electrical disasters have not been greatly reduced despite continuous prevention efforts until now. However, the smart distribution board which can be measured information about general electrical condition such as current, voltage, power, power factor etc. and electrical safety condition such as over-current, leakage current, arc etc. and communicated analysis information about electrical condition with server will be helpful for the prevention of electrical disasters through real-time surveillance and data analysis under smart grids based on the two-way communication. In this paper, the proposal standard of smart distribution board for electrical safety is suggested about the structure, functional requirements of compositions, communication, security and so on.

Development of advanced Power Factor Computation Algorithm in Harmonics distorted Distribution System (고조파 왜곡 환경에서 향상된 역률 계측 알고리즘 개발)

  • Lee, Hyun-woo;Park, Young-kyun;Lee, Jinhan;Joung, Sanghyun;Park, Chul-woo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.7
    • /
    • pp.121-127
    • /
    • 2016
  • We propose a algorithm to calculate power factor of fundamental waveform in an environment where the voltage and current have been distorted by harmonics. In the proposed power factor computation algorithm, voltage and current are converted to rotating DQ reference frame, and power factor is calculated from active power and reactive power. We compare the proposed method with the conventional power factor measurement method as mathematically. In a condition that voltage and current are distorted by harmonics, the proposed method accurately measure the power factor of fundamental wave, and it is confirmed by simulation using MATLAB. If the proposed power factor measurement method is applied to an automatic power factor control system, a power factor compensation performance can be maximized in harmonic distortion environment. As a result, it is possible to reduce electricity prices, reduce line loss, increase load capacity, ensure the transmission margin capacity, and reduce the amount of power generation.

Characteristics Analysis of 3-phase Induction Generator at the Unbalanced Load Operation (불평형 부하 운전시 3상 유도발전기 특성 해석)

  • Kim, Jong-Gyeum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.3
    • /
    • pp.123-128
    • /
    • 2007
  • Hydro power supplies no pollution energy, mainly induction generator has been applied at the small capacity power station. The generating power of small hydro-electric power station connects on the 22.9kV distribution system or low voltage system in the case of three-phase four-wire supply system. There are side effects of various kinds in the 3-three phase 4-wire distribution system mixing 1-phase load and 3-phase load. This system generates the voltage unbalance by unbalanced load operating condition. They have various serious effects on generator and connection system. In this paper, we analyzed what kind of operation characteristic are happened in the induction generator by customer load variation at the 3-three phase 4-wire distribution system.

The Comparison of the Current Unblance Factor According to the Cable Array Method using PSCAD/EMTDC and FEA (PSCAD/EMTDC와 FEA를 이용한 케이블 배열 방법에 따른 전류 불균형률의 비교)

  • Shin, Ho-Jeon;Kim, Ji-Ho;Kang, Gab-Suk;Kim, Jae-Chul;Lee, Hyang-Beom
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.2
    • /
    • pp.72-78
    • /
    • 2013
  • In this study, samples from the site where there occurred unbalanced current when cable routing were analyzed, and the simulation program for electric power system analysis, PSCAD/EMTDC, was used to calculate the current unbalance on cable routing. Based on electromagnetic finite element analysis(FEA), electromagnetic parameters enabled the interlocking with COMSOL for the calculation of allowable current ampacity and magnetic filed distribution. This then led to modeling unbalanced current between common modes using the unbalanced current analysis program, thereby comparing and discussing the results from both. The analyzed model is a common mode 2 parallel circuit, which is a basic model for cable routing, and by arranging cables in various ways, the arrangement with the least current unbalance was suggested, which would, in the future, prevent earth faults and extend life for the whole cable.

On the Lightning Induced Voltage Along Overhead Power Distribution Line

  • Izadi, Mahdi;Ab Kadir, Mohd Zainal Abidin;Hajikhani, Maryam
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1694-1703
    • /
    • 2014
  • Lightning induced voltage is a major factor that causes interruptions on distribution lines. In this paper, analytical expressions are proposed to evaluate a lightning induced voltage on power lines directly in the time domain without the need to apply any extra conversions. The proposed expressions can consider the widely used current functions and models in contrast to the earlier analytical expressions which had a number of limitations related to the simplification of the channel base current and the current along the lightning channel. The results show that the simulated values based on the proposed method are in good agreement with the previous studies and the proposed expressions can be used for optimizing the insulation and protection level of existing and new lines being designed.

Consumer Preferences for Wood-Framed Housing

  • Kwon, Oh-Jung
    • Architectural research
    • /
    • v.2 no.1
    • /
    • pp.17-25
    • /
    • 2000
  • The purpose of this study was; 1) to describe consumer preferences for wood~framed housing; 2) to determine factors which affect the preferences for housing environments in wood-framed housing by demographic, current housing, and wood-framed housing-related characteristics; and 3) to identify differences in preferred wood-framed housing related characteristics by demographic and current housing characteristics. From the visitors to a model wood-framed house in Seoul, Korea, 296 persons willing to live in a wood-framed house were selected as the sample for the study. Data were collected using a self-administered survey and analyzed by frequency distribution, factor analysis, chi-square test, t-test, and one-way analysis of variance procedures. The results of the study Indicated that among seven factors based on 32 housing characteristics, Factor 2 - "floor plan and Interior environment" was the major variable which showed significant difference by selected demographic characteristics. Regarding the differences in wood-framed housing related characteristics by demographic characteristics, age, gender, education, and family life cycle showed group differences. Also, housing type was the major current housing characteristic to provide significant group difference in preferred wood-framed housing characteristics.