• Title/Summary/Keyword: Current Crest Factor

Search Result 16, Processing Time 0.029 seconds

Novel Crest Factor Improvement of Electronic Ballast-Fed Fluorescent Lamp Current Using Pulse Frequency Modulation

  • Song Joong-Ho;Choy Ick;Choi Ju-Yeop
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.98-103
    • /
    • 2001
  • In case that electronic ballast employing a valley-fill passive power factor correction (PFC) circuit is used for feeding fluorescent lamps, a new method to reduce crest factor of the lamp current is studied in this paper. In order to reduce crest factor to lower value, a pulse frequency modulation technique based on the waveform of the dc-link voltage which is predetermined by the passive PFC circuit, is taken into the switching control action of the electronic ballast. An equation-based analysis between the crest factor of lamp current and the effect of varying the inverter switching frequency is comprehensively performed.

  • PDF

Analysis of the Leakage Impulse Current in Faulty Insulators for Detection of Incipient Failures (절연물의 초기사고 감지를 위한 누설 임펄스 전류의 해석)

  • Kim, Chang-Jong;Lee, Heung-Jae;Sin, Jeong-Hun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.8
    • /
    • pp.390-398
    • /
    • 2000
  • Leakage impulse current of the contaminated insulators by using experiment data were studied. The impulse current in phase-time relationship was analyzed on line post insulators. Also, frequency components and crest factor of the leakage current were investigated to provide a scheme for an early detection of insulator incipient failure. The study shows that the phase-time characteristic is non-stationary and random and, non-harmonic component and crest factor can be promising parameters for detecting insulator leakage currents.

  • PDF

Analysis of Volatage and Current Waveform Distortion Characteristics at Office Buildings (사무용 빌딩에서의 전압 및 전류파형 왜곡특성 분석)

  • Yoo, Jae-Geun;Lee, Sang-lck;Jeon, Jeong-Chay;Jeong, Jong-Wook;Lim, Young-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.155-161
    • /
    • 2005
  • Nonlinear electronic loads used at office buildings distort the voltage and current waveform that cause the overheating of transformer losses, ELB(Electrical Leakage Breaker) tripping, and so on. This paper analyzed waveform distortion characteristics at several once buildings by comparing with magnitude of voltage and current harmonics, crest factor of voltage and current, phase voltage and current unbalance. As a consequence, severe current waveform distortion in phase and neutral line by harmonics and high current unbalance rates by unbalanced using of single loads among the three phases are investigated. The results of the study can be used in making decisions regarding reasonable and economical operating of loads at office buildings.

A New Control Method for The High Frequency Electronic Ballast (고주파 전자식 안정기의 새로운 제어방법)

  • Oh, Duk-Jin;Kim, Hee-Jun;Cho, Kyu-Min
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.746-749
    • /
    • 2002
  • This paper presents a new control method for the high frequency electronic ballast which is operated with raw rectified dc link using diode bridge. For the commercial electronic ballast, proper ac input power factor and crest factor of the lamp current are required. The most ballast, therefore, has a active or passive power factor collection (PFC) circuit. With the proposed method, it can be achieved simultaneously that grater than 0.9 of input power factor and less than 1.85 of lamp current crest factor without any PFC circuit. In this paper, the proposed ballast control scheme and the experimental results for the application to the fluorescent lamp are described.

  • PDF

A new control scheme of Class-E electronic Ballast with low crest factor (저 파고율 특성을 갖는 Class-E 전자식 안정기의 새로운 제어 기법)

  • Chon, Hyun-Son;Lee, Dong-Yun;Hyun, Dong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.234-236
    • /
    • 2003
  • In this paper, a new control scheme of Class-E inverter for reducing the crest factor of electronic ballasts for fluorescent lamps using Pulse-Frequency-Modulation (PFM) is introduced The lifetime of the lamps is guaranteed by decreasing the lamp crest factor and voltage stress of the switch is significantly decreased by a new scheme although conventional Class-E inverter is used in this paper The proposed PFM control scheme doesn't used any auxiliary circuit. The proposed control strategy is executed by feeding back the input current. and the Zero-Voltage-Switching (ZVS) is ensured by operating beyond resonant frequency. Therefore, the control principles of proposed method are explained in detail and its validity is verified through several simulated results.

  • PDF

Analysis of Electrical Characteristics of CCFL Exit Light (CCFL유도등의 전기적 특성 분석)

  • Jung, Jong-Jin
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.184-193
    • /
    • 2021
  • Purpose: In this study, since the operation principle of the CCFL Exit light is the same as that of general lighting equipment, the characteristics of the CCFL Exit light were analyzed by deriving test items that can affect the characteristics of the light source from the KS standard, which is the standard for lamp ballast performance certification of general lighting equipment. Method: The samples used in the experiment were performed on products of two manufacturers for each size, such as large, medium, and small, and the test items were power factor, crest factor, and current harmonic distortion. Result: As a result of the experiment, the power factor showed a value between 0.4 and 0.6 in all samples, which was smaller than the 0.9 value set by KS. The crest factor ranged from 3.6 to 3.7 for large, 4.4 to 4.7 for medium, and 3.5 to 3.7 for small. It showed a value more than two times higher than the KS standard of 1.7. Current total harmonic distortion ranged from 81% to 110%, and considering that the KS standard was less than 20%, it could be confirmed that all samples had a value significantly exceeding the KS standard. Conclusion: The crest factor and current total harmonic distortion may affect the temperature rise of the light source and the burnout of the device. When developing an exit light, if this item is developed within the scope of the KS standard, the quality improvement and maintenance of the exit light will be greatly improved.

A Study of Stability Analysis for Exit Light (유도등의 안정성 해석에 관한 연구)

  • Jung, Jong-Jin;SaKong, Seong-Ho
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.81-85
    • /
    • 2008
  • In this study, Standards of Lighting Appliance and Standard of Model Approval and Inspection Technology for EXIT LIGHT are compared so as to analyze stability of a exit light which is fire product. Test items, which are not included in Standard of Model approval and Inspection Technology for EXIT LIGHT, are deduced from aforementioned comparison and analysis. Also the derived test items are experimented with a exit light. For a power factor correction, a power factor correction circuit is designed and power factor, crest factor, asymmetry ratio, luminance variation are analyzed. In order to show the validity of designed circuit, current waveform and voltage waveform are measured.

Pspice Model of a ZnO Varistor for Impulse Current (임펄스 전류에 대한 ZnO 바리스터의 Pspice 모델)

  • Lee, B.H.;Kong, Y.H.;Lee, D.M.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2161-2163
    • /
    • 1999
  • Generally, ZnO varistors have dynamic characteristics that the cut-off voltage increases as the time to crest of the varistor current decreases. Dynamic characteristics of ZnO varistor are the most important factor in region of the steep front discharge current particularly. Also, V-I characteristics of ZnO varistor have hysterisis loop in time domain and frequency dependency. This paper deals with ZnO varistor numerical equation and modeling method which takes the behavior of varying clamping voltage into consideration during the time to crest, in range of $1{\mu}m{\sim}50{\mu}m$, of impulse current applied to a ZnO varistor. The simulated results by the proposed model are compared with experimental results for each of the impulse current.

  • PDF

Slope Stability Analysis of Filldams by Modified Seismic Intensity Method (수정진도법에 의한 댐사면 안정해석)

  • 신동훈;이종욱
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.223-228
    • /
    • 2000
  • The current slope stability analysis of a filldam is based on the limit equilibrium method, and in calculation of safety factor during earthquake, adopts the seismic intensity method in which it considers a uniform seismic force from dam foundation to crest. However the observed behaviour of filldam during earthquake shows some different behaviour in that at the crest the measured acceleration is usually several times the ground acceleration. In this study, slope stability calculations of a filldam are provided based on the modified seismic intensity method, which can take into account the amplification phenomena of acceleration in the upper part of dam. And also the results of calculations are compared with that of current seismic intensity method.

  • PDF

A Study on T5 28W Fluorescent Lamp Ballast Using a Piezoelectric Transformer and One-chip Microcontroller (One Chip Microcontroller와 압전변압기를 이용한 T5 28W 형광등용 전자식 안정기에 관한 연구)

  • 황락훈;류주현;장은성;조문택;안익수;홍재일
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.70-79
    • /
    • 2003
  • In this paper, T5 28-watt fluorescent lamp ballast using a piezoelectric transformer is fabricated and its characteristic is investigated. Developed electronic ballast is composed of basic circuits and blocks, such as rectifier part, active power factor corrector part, frequency oscillation part using microcontroller and feedback control, piezoelectric transformer and resonant half bridge inverters. The fabricated ballast uses to variable frequency methode in external so exciting that the frequency of piezoelectric transformer could be generated by voltage control oscillator using microcontroller(AT90S4433). The current of fluorescent lamp is detected by feedback control circuit. The signal of inverter output is received using Piezoelectric transformer, and then its output transmitted to fluorescent lamp. Traditional electromagnetic ballasts operated at 50-60Hz have been suffered from noticeable flicker, high loss, large crest factor and heavy weight. A new electronic ballast is operated at high frequency about 75kHz, and then Input power factor, distortion of total harmonic and lamp current crest factor are measured about 0.9!35, 12H and 1.5, respectively Accordingly, the traditional ballast is by fabricated electronic ballast using piezoelectric transformer and voltage control oscillator because of its lighter weight, high efficiency, economic merit and saving energy.