• 제목/요약/키워드: Current Comparator

검색결과 133건 처리시간 0.032초

전류변성기 비교기의 비오차 평가 기술 (Evaluation Technique for Ratio Error of Current Transformer Comparator)

  • 김윤형;한상길;정재갑;한상옥
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.291-295
    • /
    • 2008
  • We have developed an evaluation technique for ratio errors of current transformer (CT) comparator by using the precise standard capacitors. By applying this technique for equivalent circuit of CT comparator evaluation system, we can obtain the calculated and measured ratio errors in the CT comparator. Thus we can evaluate ratio errors of CT comparator by comparing the calculated and measured ratio errors. Because this method requires only the standard capacitors, it is simple and easy method to reliability and accuracy maintenance of CT comparator. The method was applied to CT comparator under test with the ratio error ranges of $0{\sim}{\pm}10%$. The ratio error of the CT comparator under test theoretically obtained in this method are consistent with that measured for same CT comparator under test by using wide ratio error CT within an estimated expanded uncertainty (k = 2) in the overall ratio error ranges.

전류변성기 비교기의 비오차 및 위상오차 평가기술 (Evaluation Technique for Ratio Error and Phase Displacement of Current Transformer Comparator)

  • 김윤형;한상길;정재갑;한상옥
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.437-443
    • /
    • 2008
  • We have developed an evaluation technique for both ratio error and phase displacement of current transformer (CT) comparator by using the precise standard capacitors and resistors. By applying this technique to equivalent circuit of CT comparator evaluation system, we can obtain the calculated and measured ratio errors (or phase displacements) in the CT comparator. Thus we can evaluate ratio errors and phase displacement of CT comparator by comparing the calculated and measured ratio errors (or phase displacements). The method was applied to CT comparator under test with the ratio errors and phase displacement ranges of $0{\sim}{\pm}10%$ and $0{\sim}{\pm}7.5$ crad, respectively. Finally we have compared the ratio error and phase displacement of the CT comparator obtained in this method with specifications of two companies.

Evaluation of Low Power and High Speed CMOS Current Comparators

  • Rahman, Labonnah Farzana;Reaz, Mamun Bin Ibne;Marufuzzaman, Mohammad;Mashur, Mujahidun Bin;Badal, Md. Torikul Islam
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권6호
    • /
    • pp.317-328
    • /
    • 2016
  • Over the past few decades, CMOS current comparators have been used in a wide range of applications, including analogue circuits, MVL (multiple-valued logic) circuits, and various electronic products. A current comparator is generally used in an ADC (analog-to-digital) converter of sensors and similar devices, and several techniques and approaches have been implemented to design the current comparator to improve performance. To this end, this paper presents a bibliographical survey of recently-published research on different current comparator topologies for low-power and high-speed applications. Moreover, several aspects of the CMOS current comparator are discussed regarding the design implementation, parameters, and performance comparison in terms of the power dissipation and operational speed. This review will serve as a comparative study and reference for researchers working on CMOS current comparators in low-power and high-speed applications.

전류변성기 비교기의 위상오차 평가 기술 (Evaluation technique for phase displacement of current transformer comparator)

  • 김윤형;한상길;정재갑;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2032-2033
    • /
    • 2008
  • We have developed an evaluation technique for phase displacement of current transformer (CT) comparator by using the precise standard capacitors and resistors. By applying this technique for equivalent circuit of CT comparator evaluation system, we can obtain the calculated and measured phase displacement in the CT comparator. Thus we can evaluate phase displacement of CT comparator by comparing the calculated and measured phase displacement. The method was applied to CT comparator under test with the phase displacement ranges of $0{\sim}{\pm}7.5$ crad. Finally we have compared the phase displacement of the CT comparator under test theoretically obtained in this method with the specification.

  • PDF

전류변성기 비교기를 이용한 인덕터의 절대 평가 (Absolute Evaluation of Inductor Using Current Transformer Comparator)

  • 김윤형;정재갑;한상길;김한준;한상옥
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.279-284
    • /
    • 2008
  • We have developed two absolute evaluation technology of inductor using current transformer (CT) comparator. One is the method that the reactance of inductor is obtained by analysing the equivalent circuit of CT with inductor connected to series at secondary terminal of CT. The other is the method that the reactance of inductor is obtained by comparing phase displacement of current flowing on inductor by using CT comparator. These technologies have the advantage to apply up to rated current and voltage of inductor. The method was applied to inductors under test in the range of $100 {\mu}H{\sim}1\;H$. The inductance of the inductor under test obtained in this study are consistent with those measured by LCR meter using the same inductor within an expanded uncertainty (k = 2) in the overall range of inductance.

전류변성기 비교측정 장치의 현장 평가기술 (On-Site Evaluation Technique of Current Transformer Comparator System)

  • 정재갑;이상화;권성원;강전홍;김명수
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.926-932
    • /
    • 2007
  • A recently developed methods for on-site calibration of the current transformer (CT) comparator system have been reviewed in the paper. The method utilizes several traveling standards, which consist of the CT, non-reactive standard resistors, wide ratio error CT, and shunt resistors. The traveling CT is used for absolute evaluation of a standard CT belonging to industry. The non-reactive standard resistors and a wide ratio error CT are used for the linearity check of errors in the current comparator. The shunt resistors are used for evaluation of CT burden of industry.

3레벨 비교기를 이용한 3상인버터의 개선된 히스테리시스 전류제어 기법 (An Improved Current Control Method for Three-Phase PWM Inverters Using Three-Level Comparator)

  • 문형수;한우용;이창구;신동용;김무연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1035-1037
    • /
    • 2001
  • This paper presents an improved hys- teresis current control method for three-phase PWM power inverters using 3-level comparator. Hysteresis current controller using 3-level comparator has an advantage of constant switching frequency compared with conventional hysteresis current controller. However, this method has disadvantage that the longer sampling period, the larger current error because the switching is performed without considering current error magnitude of each phase. The proposed method improves the control performance by selecting the optimum switching pattern in which the magnitudes of current errors are considered introducing space vector concept. Simulation results using Matlab/Simulink show that the proposed control method reduces current error keeping the merit of previous hysteresis current control method.

  • PDF

40,000 A 로고스키 코일 평가 시스템 구축 (Establishment of Evaluation System for 40,000 A Rogowski Coil)

  • 김윤형;한상길;정재갑;강전홍;이상화;한상옥
    • 전기학회논문지P
    • /
    • 제58권2호
    • /
    • pp.202-206
    • /
    • 2009
  • Evaluation system for calibrating Rogowski coiI(RC) up to primary current of 40,000 A have been established. The system consists of 40,000 A AC high current source, current transformer(CT) comparator, standard CT, RC under test, voltage to current convertor(VCC), buffer and CT burden. An AC high current is applied to the primary windings of both the standard CT and the RC under test, and then the CT comparator measures the ratio error and the phase displacement by comparing the secondary current of the standard CT with output current of VCC. For testing of RC, we have evaluated two RCs under test of primary current ranges of 0 A ${\sim}$ 2,000 A and 0 A ${\sim}$ 40,000 A with the accuracy class of 1 %. The extended uncertainty is 0.02 % ${\sim}$ 0.23 % for ratio error and 0.29 min ${\sim}$ 1.93 min for phase displacement in the primary current ranges of 10 ${\sim}$ 40,000 A.

광범위 비오차 표준 전류변성기의 개발 및 그 응용 (Development of The Standard Current Transformer with Wide Ratio Error and Its Application)

  • 권성원;정재갑;이상화;김문석;김명수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권6호
    • /
    • pp.302-307
    • /
    • 2006
  • Standard current transformer(CT) with the nominal ratio errors in the range of - 10 % to + 10 % has been developed. Linearity of the CT ratio error measuring system (CT comparator) has been tested by using wide ratio error standard current transformer(WRE CT). The developed WRE CT can be used to evaluate the linearity of the CT comparator by comparing both the theoretical values and experimental values of the WRE CT. The developed method has been successfully applied for calibration and correction in the CT comparator belonging to industry.