• Title/Summary/Keyword: Curing solution

Search Result 287, Processing Time 0.021 seconds

Curing Method Designation System in Mat Foundation Construction (매트기초 건설을 위한 양생방법 선정시스템)

  • Lee, Tae-Gyu
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.8
    • /
    • pp.366-372
    • /
    • 2012
  • In most of construction work, especially mat foundation construction, it is very important that accidents be prevented at early aged construction stage. To reduce the risk of accidents, it is necessary to choose the curing method to provide instructions for safety forming work by proper curing of concrete after placing. Therefore, this paper has proposed a designation algorithm of curing method for representing curing type and period by analyzing the transient hydration heat solution, focusing on mat foundation construction. This has been implemented, moreover, using an object oriented programming language to develop structural analysis system taking account crack index. In addition, we present in this paper a safety curing management system developed to assess risk during forming work.

Study on the Crack Control Effect of Moist Curing Equipment in Side Wall of Building (습윤양생 장치를 이용한 아파트 측벽 균열제어에 관한 연구)

  • Kim, Dae-Geon;Lee, Dong-Woon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.2
    • /
    • pp.127-134
    • /
    • 2017
  • In this study, moist curing equipment was used in the exist gang-form system. By achieving sufficient spray curing, the quality of the concrete was improved and the cracking occurred in building's side wall was decreased. The following results could be made as the conclusion. For the compressive strength, all zones showed the similar results. Comparing with the zone without using moist curing equipment, the zone used moist curing equipment showed higher rebound hardness results. For the cracking, the zone utilized moist curing equipment showed the cracking averaged as 6.6 m and the zone without using moist curing equipment showed the cracking averaged as 10.3m. The effectof reducing cracking by utilizing moist curing equipment is about 36 %. Using moist curing equipment is considered as a good solution to reduce the cracking in the structure. Considering all the factors analysed, using moist curing equipment improved the quality of the concrete and decreased the cracking. When this equipment was used in the construction site, it is expected that the construction periodcan be shrunk and the ratio of defect caused by drying shrinkage can be decreased. In this research conditions, The 0.3mm sized moist curing equipment provided the most desirable results on concrete quality and preventing cracking.

Effect of Curing Solution and Pre-Rust Process on Rebar Corrosion in the Cement Composite (시멘트 복합체 내부 철근 부식에 양생 용액과 철근 사전 부식이 미치는 영향)

  • Du, Rujun;Jang, Indong;Lee, Hyerin;Yi, Chongku
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.2
    • /
    • pp.1-8
    • /
    • 2022
  • The corrosion of reinforcement is the main reason for the performance degradation of concrete structures. The pre-rusted parts of rebar in concrete structures are vulnerable to the corrosion, especially if the structure is exposed to wet or chlorinated environments. In this study, effects of different curing solution on corrosion behavior of the pre-rusted rebars in the cement composites were investigated. HCl(3%) and CaCl2(10%) solution were utilized to accelerate the pre-rust of the rebar, and each pre-rust condition rebar including reference (RE) were placed in mortar cylinder. Three kinds of samples then were cured in CaCl2 (3%) solution and tap water respectively for 120 days. Electrochemical polarization and half-cell potential measurement were used to monitor the influence of curing water on the corrosion behavior of pre-rusted steel bar in cement composite. The surface morphology and composition of corroded steel bar were analyzed by scanning electron microscope and energy dispersive X-ray diffraction. The results show that the corrosion rates of pre-rusted samples in both curing water are higher than that of non-pre-rusted samples. The corrosion rates of RE, CaCl2 and HCl pre-rusted samples in salt water were 8.14, 4.48, 13.81 times higher than those in tap water respectively, on the 120th day.

A STUDY OF MONOMER RELEASE FROM PIT AND FISSURE SEALANTS ACCORDING TO VARIOUS LIGHT SOURCES (광원에 따른 수종의 치면열구전색제로부터 용리되는 모노머에 관한 연구)

  • Seo, Hyun-Woo;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.2
    • /
    • pp.284-292
    • /
    • 2005
  • The aim of this study was to identify and quantify the major or detectable monomers released from any of five commercially-available, light-cured pit and fissure sealants with three different light sources : conventional halogen light curing unit, plasma arc light curing unit and LED curing unit. After curing, specimens were immediately immersed in distilled water for different time intervals. The time related release of monomers were analyzed by high performance liquid chromatography(HPLC). Identification and quantitative analysis of monomers were performed by the comparison of the elution time and the absorption peak height of the eluates with those of the authentic sample. The result of this study can be summarized as follows. 1. Standard solution peaks with retention times of 2.3, 3.2, 5.6, 6.5, 10.4 minutes were identified as BPA, TEGDMA, UDMA, Bis-GMA, Bis-DMA, respectively. 2. None of the chromatograms of the tested sealants displayed peaks with the same retention time as that of the standard solution, except for TEGDMA. 3. The highest release rate of TEGDMA was observed during the 12hr period for all samples and declined thereafter. 4. The elution of TEGDMA from curing with Halogen curing unit for 20 second and LED for 10 second was less than that resulting from curing with Plasma arc for 3 second. 5. TEGDMA was detected at much lower levels in eluates from the Pit & Fissure $Sealant^{TM}$ than other sealants. The elution of TEGDMA from the $Helioseal^{(R)}$ F cured with Halogen light curing unit, the $Concise^{TM}$ cured with Plasma arc curing unit and the $Teethmate^{(R)}$ F-1 cured with LED curing unit were higher than other sealants.

  • PDF

Investigating the long-term behavior of creep and drying shrinkage of ambient-cured geopolymer concrete

  • Asad Ullah Qazi;Ali Murtaza Rasool;Iftikhar Ahmad;Muhammad Ali;Fawad S. Niazi
    • Structural Engineering and Mechanics
    • /
    • v.89 no.4
    • /
    • pp.335-347
    • /
    • 2024
  • This study pioneers the exploration of creep and shrinkage behavior in ambient-cured geopolymer concrete (GPC), a vital yet under-researched area in concrete technology. Focusing on the influence of sodium hydroxide (NaOH) solution concentration, the research utilizes low calcium fly ash (Class-F) and alkaline solutions to prepare two sets of GPC. The results show distinct patterns in compressive strength development and dry shrinkage reduction, with a 14 M NaOH solution demonstrating a 26.5% lower dry shrinkage than the 16 M solution. The creep behavior indicated a high initial strain within the first 7 days, significantly influenced by curing conditions and NaOH concentration. This study contributes to the existing knowledge by providing a deeper understanding of the time-dependent properties of GPC, which is crucial for optimizing its performance in structural applications.

Technology to reduce water ingress for TBM cutterhead intervention

  • Ham, Soo-Kwon;kim, Beom-Ju;Lee, Seok-Won
    • Geomechanics and Engineering
    • /
    • v.29 no.3
    • /
    • pp.321-329
    • /
    • 2022
  • Tunnel site where high water pressure is applied, such as subsea tunnel, generally selects the shield TBM (Tunnel Boring Machine) to maintain the tunnel excavation face. The shield TBM has cutters installed, and the cutters wear out during the process of excavation, so it should be checked and replaced regularly. This is called CHI (Cutterhead Intervention). The conventional CHI under high water pressure is very disadvantageous in terms of safety and economics because humans perform work in response to high water pressure and huge water inflow in the chamber. To overcome this disadvantage, this study proposes a new method to dramatically reduce water pressure and water ingress by injecting an appropriate grout solution into the front of the tunnel face through the shield TBM chamber, called New Face Grouting Method (NFGM). The tunnel model tests were performed to determine the characteristics, injection volume, and curing time of grout solution to be applied to the NFGM. Model test apparatus was composed of a pressure soil tank, a model shield TBM, a grout tank, and an air compressor to measure the amount of water inflow into the chamber. The model tests were conducted by changing the injection amount of the grout solution, the curing time after the grout injection, and the water/cement ratio of grout solution. From an economic point of view, the results showed that the injection volume of 1.0 L, curing time of 6 hours, and water/cement ratio of the grout solution between 1.5 and 2.0 are the most economical. It can be concluded that this study has presented a method to economically perform the CHI under the high water pressure.

Mechanical Properties of Radiation-Curing Vinyl Ester Resin (방사선 경화 비닐에스터 수지의 기계적 특성 연구)

  • Shin, Bum-Sik;Jeun, Joon-Pyo;Kim, Hyun Bin;Kang, Phil-Hyun
    • Journal of Radiation Industry
    • /
    • v.4 no.1
    • /
    • pp.19-23
    • /
    • 2010
  • Vinyl ester (VE) resins, introduced in the late 1960s, have made large strides in reinforced plastics applications as adhesive and matrix materials on their appropriate mechanical performance characteristics in the glassy state. Generally, VE resins are a group of dimethacrylate resins based on bisphenol A type epoxy resin. They exhibit easy handling properties as well as good resistance to most chemical agents due to their mechanical and thermal properties. In this study, the effects of curing methods of vinyl ester resins on gel contents, flexural strength and dynamic mechanical properties were investigated. Thermal curing (room temperature, $80^{\circ}C$) and electron beam curing were used to crosslink a VE resin/styrene complex (65/35 wt%) with methyl ethyl ketone peroxide (MEKPO) as a catalyst and an 8 wt% cobalt naphthenate in styrene solution as a accelerator. For the samples, gel contents as well as flexural strength and dynamic mechanical properties were characterized and compared by soxhlet apparatus, universal testing machine (UTM) and dynamic mechanical analysis (DMA). As a result, the electron-cured VE resin was confirmed as a better condition than those for gel contents, flexural strength and dynamic mechanical properties, respectively.

X-ray CT monitoring of macro void development in mortars exposed to sulfate attack

  • Tekin, Ilker;Birgul, Recep;Aruntas, Huseyin Y.
    • Computers and Concrete
    • /
    • v.21 no.4
    • /
    • pp.367-376
    • /
    • 2018
  • This study reports the results of nondestructive monitoring of macro void developments in mortars manufactured with both ordinary Portland cement and sulfate resistant cement. Two types of curing were utilized; tap water curing and another curing environment that contains 5% $Na_2(SO_4)$ solution. Being the primary objective of this study, macro void developments of the mortar specimens were monitored by X-ray Medical Computerized Tomography. Compressive strength tests and water absorption tests were conducted on specimens that were kept in both curing environments for a duration of 560 days. Data analyses yielded consistent results among the three tests used in this experimental study. Macro void ratios of mortars decreased at the beginning of experiments for a certain period; afterwards, macro void ratios increased. The objective of this study was accomplished as anticipated since X-CT image analysis was able to nondestructively monitor macro void development process in cement mortars.

Fundamental Research on Compressive Strength Recovery of Excessive High-volume Fly Ash Mortar (Fly Ash가 다량치환된 모르타르의 압축강도 회복에 관한 기초적 연구)

  • Choi, Yoon-Ho;Sin, Se-Jun;Han, Jun-Hui;Hyun, Seung-Yong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.199-200
    • /
    • 2019
  • The purpose of the research is assessing the possibility of strength recovery for mortar added with accidently high amount of fly ash. For compressive strength at 28 day, the sample painted with sodium hydroxide showed higher compressive strength than the sample painted with calcium hydroxide. Regarding the curing conditions, the curing temperature 65℃ provided better conditions than the curing temperature 20℃ in aspect of solution penetration depth and reactivity of fly ash. In the case of drying after saturation, the case painted with sodium hydroxid 65℃ showed the clearest engrossing mark.

  • PDF

CYTOTOXICITY OF RETROGRADE FILLING MATERIALS TESTED BY 51Cr RELEASE, MIT AND LD ACTIVITY (51Cr방출과 MTT 및 LD활성도를 이용한 역충전재의 세포독성에 관한 연구)

  • Choi, La-Young;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.409-428
    • /
    • 1994
  • Endodontic surgery is performed when conventional endodontic therapy fails or is contraindicated. In such cases, retrograde filling materials including amalgam, composite resin, and various cements have been used. Biocompatibilty and margin sealing ability of retrograde filling materials are important for the long term success of endodontic surgery. In vitro cell culture is frequently used as the method of measuring the biocompatibilty of dental materials. The purpose of this study was to evaluate the cytotoxicity of six kinds of retrograde filling materials including newly developed light curing glass ionomer cements. Each material was mixed according to. the manufacture's instruction and evaluated as : freshly mixed, 24-hour after mixing, and 168-hour after mixing respectively. The elution solution was extracted after 24-hour contact with materials using media. Cytotoxicity was evaluated by direct contact, or elution contact. Test results of radiochromium($^{51}Cr$) release, cell viability using tetrazolium dye (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl dimethyltetrazolium bromide(MTT) test and lactate dehydrogenase(LD) of damaged L929 cells were analyzed. In the $^{51}Cr$ release of direct contact, all experimental retrograde filling materials except amalgam and glass ionomer cement showed increased cytotoxicity compared to control. In the $^{51}Cr$ release of elution solution, the released $^{51}Cr$ was so minimal that it was impossible. to evlauate the cytotoxicity exactly. The elution solutions of glass ionomer cement and IRM showed marked cytotoxicity in MTT test. LD enzyme activity was highest in tests of direct contact with composite, light curing composite, and light curing glass ionomer cement and IRM. Amalgam revealed least cytotoxicity while IRM showed cytotoxicity using all three methods. Composite, light curing composite and light curing glass iomomer cement were cytotoxic in the tests of $^{51}Cr$ release and LD activity. Glass ionomer cement showed cytotoxic effect only in the MTT method. From these results it is suggested that the standardization and optimization of cytotoxicity testing, especially using elution solutions, should be strongly advised.

  • PDF